Search NASA⌕ Search

SEARCH · Search NASA

Results for “filtering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Methods and apparatuses using filter banks for multi-carrier spread spectrum signals

A transmitter includes a synthesis filter bank to spread a data symbol to a plurality of frequencies by encoding the data symbol on each frequency, apply a common pulse-shaping filter, and apply gains to the frequencies such that a power level of each frequency is less than a noise level of other communication signals within the spectrum. Each frequency is modulated onto a different evenly spaced subcarrier. A demodulator in a receiver converts a radio frequency input to a spread-spectrum signal in a baseband. A matched filter filters the spread-spectrum signal with a common filter having characteristics matched to the synthesis filter bank in the transmitter by filtering each frequency to generate a sequence of narrow pulses. A carrier recovery unit generates control signals responsive to the sequence of narrow pulses suitable for generating a phase-locked loop between the demodulator, the matched filter, and the carrier recovery unit.

42 ENGINEERING↗

Methods and apparatuses using filter banks for multi-carrier spread spectrum signals

A transmitter includes a synthesis filter bank to spread a data symbol to a plurality of frequencies by encoding the data symbol on each frequency, apply a common pulse-shaping filter, and apply gains to the frequencies such that a power level of each frequency is less than a noise level of other communication signals within the spectrum. Each frequency is modulated onto a different evenly spaced subcarrier. A demodulator in a receiver converts a radio frequency input to a spread-spectrum signal in a baseband. A matched filter filters the spread-spectrum signal with a common filter having characteristics matched to the synthesis filter bank in the transmitter by filtering each frequency to generate a sequence of narrow pulses. A carrier recovery unit generates control signals responsive to the sequence of narrow pulses suitable for generating a phase-locked loop between the demodulator, the matched filter, and the carrier recovery unit.

42 ENGINEERING↗

Filter replacement lifetime prediction

Systems for predicting a filter lifetime. A filter monitoring system includes a filter effectiveness history based on contaminant sensor information associated with a filter received from one or more contaminant sensors. A lifetime module is configured to determine a rate of filter consumption based on the filter effectiveness history and to determine a remaining filter lifetime based on the determined rate of filter consumption.

42 ENGINEERING↗

A Sub-Threshold Low-Power Integrated Bandpass Filter for Highly-Integrated Spectrum Analyzers

Low-power analog filter banks provide frequency analysis with minimal power and space requirements, making them viable solutions for integrated remote audio- and vibration-sensing applications. Compared with their digital counterparts, analog filter banks are better suited to achieve the lower power consumption necessary for IoT applications. In this work, the design and implementation of a sub-threshold complementary metal-oxide semiconductor (CMOS) integrated low-power tunable bandpass filter channel for signal spectrum analysis and signal discrimination is presented, including performance improvements to stability and precise matching between filter stages. The 8 th -order filter channel achieves an effective Q-factor of 4.5 and dynamic range of 60 dB, has an operational frequency range from 2 kHz to 100 kHz, and consumes 256 µW nominally at the highest center frequency. An integrated analog Gm-C filter topology is selected for this application. Functionally, the high-Q bandpass filter transfer function is implemented via four cascaded 2 nd -order filter cells and is fabricated in 130-nm 1.2-V CMOS technology, making it suitable for use in monolithic integrated spectral analysis (MISA) applications.

Long, Gavin↗

Fractional delay filter for a digital signal processing system

A processing element for implementation in a digital signal processing system is provided. The processing element is configured to receive a first data stream comprising a plurality of digital values where each value represents a sample of an analog signal. The processing element is further configured to receive a second data stream comprising a series of digital values where each value represents a sample of the analog signal. The processing element is configured to filter the first data stream via a first Farrow-structured fractional delay (FD) filter and output a filtered first data stream; filter the second data stream via a second Farrow-structured FD filter and output a filtered second data stream; and temporarily store values from the second data stream and output the stored values to the first Farrow-structured FD filter so that the stored values can be used to filter the first data stream.

Stanley, Dennis L.↗

Generalized Theory and Realization of Reconfigurable Bandpass Filtering Equalizers

Here, in this article, a generalized theory of bandpass filtering equalizers is proposed. A filtering equalizer is a device that combines the frequency-selective properties of a filter with the controllable slope of an equalizer into a single component. The equations used to design the function for a desired slope are provided, and the design methodology to determine the necessary filtering polynomials is also shown. The controllable slope of the dual-function component is realized using variable capacitors, which are used to tune both a transmission zero and a matching network to achieve the desired slope. A third-order bandpass filtering equalizer is designed, fabricated, and measured to verify the generalized theory. The component is designed to operate at 1 GHz with a slope that can be reconfigured from 1 to 3 dB along the passband. This proposed filtering equalizer demonstrates the feasibility of a tunable, low-cost, size, weight, and power (C-SWaP) solution to enable increased flatness in the overall system response and thereby decrease the error vector magnitude (EVM) of future radio frequency (RF) systems and a design process that allows for future development of filtering equalizers.

Filter↗

Project Report: Reducing Color Rivalry in Imagery for Conjugated Multiple Bandpass Filter Based Stereo Endoscopy

A pair of conjugated multiple bandpass filters (CMBF) can be used to create spatially separated pupils in a traditional lens and imaging sensor system allowing for the passive capture of stereo video. This method is especially useful for surgical endoscopy where smaller cameras are needed to provide ample room for manipulating tools while also granting improved visualizations of scene depth. The significant issue in this process is that, due to the complimentary nature of the filters, the colors seen through each filter do not match each other, and also differ from colors as seen under a white illumination source. A color correction model was implemented that included optimized filter selection, such that the degree of necessary post-processing correction was minimized, and a chromatic adaptation transformation that attempted to fix the imaged colors tristimulus indices based on the principle of color constancy. Due to fabrication constraints, only dual bandpass filters were feasible. The theoretical average color error after correction between these filters was still above the fusion limit meaning that rivalry conditions are possible during viewing. This error can be minimized further by designing the filters for a subset of colors corresponding to specific working environments.

conjugated multiple bandpass filters (CMBF)↗

First Magnetic Resonance Imaging-Guided Aortic Stenting and Cava Filter Placement Using a Polyetheretherketone-Based Magnetic Resonance Imaging-Compatible Guidewire in Swine: Proof of Concept

The purpose of this study was to demonstrate feasibility of percutaneous transluminal aortic stenting and cava filter placement under magnetic resonance imaging (MRI) guidance exclusively using a polyetheretherketone (PEEK)-based MRI-compatible guidewire. Percutaneous transluminal aortic stenting and cava filter placement were performed in 3 domestic swine. Procedures were performed under MRI-guidance in an open-bore 1.5-T scanner. The applied 0.035-inch guidewire has a PEEK core reinforced by fibres, floppy tip, hydrophilic coating, and paramagnetic markings for passive visualization. Through an 11F sheath, the guidewire was advanced into the abdominal (swine 1) or thoracic aorta (swine 2), and the stents were deployed. The guidewire was advanced into the inferior vena cava (swine 3), and the cava filter was deployed. Postmortem autopsy was performed. Procedural success, guidewire visibility, pushability, and stent support were qualitatively assessed by consensus. Procedure times were documented. Guidewire guidance into the abdominal and thoracic aortas and the inferior vena cava was successful. Stent deployments were successful in the abdominal (swine 1) and thoracic (swine 2) segments of the descending aorta. Cava filter positioning and deployment was successful. Autopsy documented good stent and filter positioning. Guidewire visibility through applied markers was rated acceptable for aortic stenting and good for venous filter placement. Steerability, pushability, and device support were good. The PEEK-based guidewire allows either percutaneous MRI-guided aortic stenting in the thoracic and abdominal segments of the descending aorta and filter placement in the inferior vena cava with acceptable to good device visibility and offers good steerability, pushability, and device support.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Difficult Removal of Retrievable IVC Filters: A Description of the 'Double-Wire Restraining' Technique

We describe our experience with the use of the 'double-wire restraining' technique to assist in the removal of two retrievable inferior vena cava filters: one had been misplaced in the right brachiocephalic vein with apex perforation of the vessel wall, and the second filter had migrated cephalad to straddle across both renal veins. The 'double-wire restraining' technique consists of two stiff-shaft Glidewires (Terumo, Somerset, NJ) placed through the same introducer sheath and positioned on opposite sides of the filter. Both wires restrain the filter at the tip of the sheath as the sheath is advanced, thus allowing the operator to reposition the filter. This report details how this technique was used to realign two malpositioned filters and reposition the filter apices from their extravascular location, thus exposing them for ensnarement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Boundary-consistent B-spline filtering schemes and application to high-fidelity simulations of turbulence

A filtering operation, based on B-spline discretizations, is introduced to target weakly growing mesh-scale oscillations that can arise in high-fidelity turbulence simulations. This is a spectral regularization that can be described using the singular values of a banded matrix operator, with the filtering strength set by a scalar- or vector-valued penalty parameter. The penalty parameter can be specified though it can also be advantageously selected to minimize the generalized cross validation (GCV) measure of distance between the pre- and post-filtered solutions. Efficient algorithms are developed to compute both the scalar and vector penalty parameters. The B-spline filter has a sharper localization to high-wavenumber than compact or explicit filters of the same stencil width and is demonstrated for solutions of the Burgers' equation, decaying Burgers' turbulence, and compressible Navier–Stokes turbulent channel flow. Furthermore, these simulations confirm the scheme's numerical stability and ability to narrowly target the high wavenumber components of numerical solutions. An advantage over finite-difference filters is that these B-spline filters are stable on bounded domains and even preserve formal order of accuracy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pattern recognition with composite correlation filters designed with multi-object combinatorial optimization

Composite correlation filters are used for solving a wide variety of pattern recognition problems. These filters are given by a combination of several training templates chosen by a designer in an ad hoc manner. In this work, we present a new approach for the design of composite filters based on multi-objective combinatorial optimization. Given a vast search space of training templates, an iterative algorithm is used to synthesize a filter with an optimized performance in terms of several competing criteria. Furthermore, by employing a suggested binary-search procedure a filter bank with a minimum number of filters can be constructed, for a prespecified trade-off of performance metrics. Computer simulation results obtained with the proposed method in recognizing geometrically distorted versions of a target in cluttered and noisy scenes are discussed and compared in terms of recognition performance and complexity with existing state-of-the-art filters.

42 ENGINEERING↗

Correlation of Spatially Filtered Dynamic Speckles in Distance Measurement Application

In this paper statistical properties of spatially filtered dynamic speckles are considered. This phenomenon was not sufficiently studied yet while spatial filtering is an important instrument for speckles velocity measurements. In case of spatial filtering speckle velocity information is derived from the modulation frequency of filtered light power which is measured by photodetector. Typical photodetector output is represented by a narrow-band random noise signal which includes non-informative intervals. Therefore more or less precious frequency measurement requires averaging. In its turn averaging implies uncorrelated samples. However, conducting research we found that correlation is typical property not only of dynamic speckle patterns but also of spatially filtered speckles. Using spatial filtering the correlation is observed as a response of measurements provided to the same part of the object surface or in case of simultaneously using several adjacent photodetectors. Found correlations can not be explained using just properties of unfiltered dynamic speckles. As we demonstrate the subject of this paper is important not only from pure theoretical point but also from the point of applied speckle metrology. E.g. using single spatial filter and an array of photodetector can greatly improve accuracy of speckle velocity measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Preliminary study of an angiographic and angio-tomographic technique based on K-edge filters

Digital Subtraction Angiography is commonly affected by artifacts due to the patient movements during the acquisition of the images without and with the contrast medium. This paper presents a preliminary study on an angiographic and angio-tomographic technique based on the quasi-simultaneous acquisition of two images, obtained using two different filters at the exit of an X-ray tube. One of the two filters (K-edge filter) contains the same chemical element used as a contrast agent (gadolinium in this study). This filter absorbs more radiation with energy just above the so called K-edge energy of gadolinium than the radiation with energy just below it. The other filter (an aluminium filter in this study) is simply used to suppress the low-energy contribution to the spectrum. Using proper calibration curves, the two images are combined to obtain an image of the contrast agent distribution. In the angio-tomographic application of the proposed technique two images, corresponding to the two filter types, are acquired for each viewing angle of the tomographic scan. From the two tomographic reconstructions, it is possible to obtain a three-dimensional map of the contrast agent distribution. The technique was tested on a sample consisting of a rat skull placed inside a container filled with water. Six small cylinders with 4.7 mm internal diameter containing the contrast medium at different concentrations were placed inside the skull. In the plain angiographic application of the technique, five out of six cylinders were visible, with gadolinium concentration down to 0.96%. In the angio-tomographic application, all six cylinders were visible, with gadolinium concentration down to 0.49%. This preliminary study shows that the proposed technique can provide images of the contrast medium at low concentration without most of the artifacts that are present in images produced by conventional techniques. The results encourage further investigation on the feasibility of a clinical implementation of the technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Problems Found Using a Radon Stripping Algorithm for Retrospective Assessment of Air Filter Samples

An evaluation of a large number of air sample filters was undertaken using a commercial alpha and beta spectroscopy system employing a passive implanted planar silicon (PIPS) detector. Samples were only measured after air flow through the filters had ceased. Use of a commercial radon stripping algorithm was implemented to discriminate anthropogenic alpha activity on the filters from the radon progeny. When uncontaminated air filters were evaluated, the results showed that there was a time-dependent bias in both average estimates and measurement dispersion of anthropogenic activity estimates with the relative bias being small compared to the dispersion, indicating that the system would not give false positive indications for an appropriately set decision level. By also measuring environmental air sample filters simultaneously with electroplated alpha filters, use of the radon stripping algorithm demonstrated a number of substantial unexpected deviations from calibrated values indicating that the system would give false negative indications. Use of the current algorithm is, therefore, not recommended for general assay applications. Use of the PIPS detector should only be utilized for gross counting without appropriate modifications to the curve-fitting algorithm. As a screening method, the radon stripping algorithm might be expected to see elevated alpha activities on air sample filters (not due to radon progeny) around the 200 disintegrations per minute level.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Multi-Model Adaptive Kalman Filtering Approach to Power System Dynamic State Estimation

Accurate information about dynamic states (such as rotor angle and speed of a synchronous machine) is important for monitoring and controlling power system rotor-angle stability. In this paper, a multi-model adaptive Kalman filtering (MMAKF) approach is proposed to accurately and robustly estimate power system dynamic states. This approach consists of three major steps: (i) multiple Kalman filtering approaches, i.e., the extended Kalman filter (EKF), unscented Kalman filter (UKF), ensemble Kalman filter (EnKF), and cubature Kalman filter (CKF), are run concurrently in parallel to estimate the dynamic states of a synchronous generator using phasor measurement unit data; (ii) probability indexes, which quantify the likelihood of each estimation model, are determined at each time step using hypothesis testing based on the measurement innovation; (iii) the a posteriori estimate of states is obtained using the best-fix approach. The two-area four-machine system is used to evaluate the effectiveness of the proposed MMAKF approach. It is shown through the Monte-Carlo method that the estimation accuracy and robustness of the proposed approach is better than those from any individual filtering algorithm.

multi-model adaptive Kalman Filtering, Power Syste↗

SU-E-I-37: Low-Dose Real-Time Region-Of-Interest X-Ray Fluoroscopic Imaging with a GPU-Accelerated Spatially Different Bilateral Filtering

Purpose: The purpose of our study is to reduce imaging radiation dose while maintaining image quality of region of interest (ROI) in X-ray fluoroscopy. A low-dose real-time ROI fluoroscopic imaging technique which includes graphics-processing-unit- (GPU-) accelerated image processing for brightness compensation and noise filtering was developed in this study. Methods: In our ROI fluoroscopic imaging, a copper filter is placed in front of the X-ray tube. The filter contains a round aperture to reduce radiation dose to outside of the aperture. To equalize the brightness difference between inner and outer ROI regions, brightness compensation was performed by use of a simple weighting method that applies selectively to the inner ROI, the outer ROI, and the boundary zone. A bilateral filtering was applied to the images to reduce relatively high noise in the outer ROI images. To speed up the calculation of our technique for real-time application, the GPU-acceleration was applied to the image processing algorithm. We performed a dosimetric measurement using an ion-chamber dosimeter to evaluate the amount of radiation dose reduction. The reduction of calculation time compared to a CPU-only computation was also measured, and the assessment of image quality in terms of image noise and spatial resolution was conducted. Results: More than 80% of dose was reduced by use of the ROI filter. The reduction rate depended on the thickness of the filter and the size of ROI aperture. The image noise outside the ROI was remarkably reduced by the bilateral filtering technique. The computation time for processing each frame image was reduced from 3.43 seconds with single CPU to 9.85 milliseconds with GPU-acceleration. Conclusion: The proposed technique for X-ray fluoroscopy can substantially reduce imaging radiation dose to the patient while maintaining image quality particularly in the ROI region in real-time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sci-Thur AM: YIS – 07: Optimizing dual-energy x-ray parameters using a single filter for both high and low-energy images to enhance soft-tissue imaging

Objective: To optimize dual-energy parameters of ExacTrac stereoscopic x-ray imaging system for lung SBRT patients Methods: Simulated spectra and a lung phantom were used to optimize filter material, thickness, kVps, and weighting factors to obtain bone subtracted dual-energy images. Spektr simulations were used to identify material in the atomic number (Z) range [3–83] based on a metric defined to separate spectrums of high and low energies. Both energies used the same filter due to time constraints of image acquisition in lung SBRT imaging. A lung phantom containing bone, soft tissue, and a tumor mimicking material was imaged with filter thicknesses range [0–1] mm and kVp range [60–140]. A cost function based on contrast-to-noise-ratio of bone, soft tissue, and tumor, as well as image noise content, was defined to optimize filter thickness and kVp. Using the optimized parameters, dual-energy images of anthropomorphic Rando phantom were acquired and evaluated for bone subtraction. Imaging dose was measured with dual-energy technique using tin filtering. Results: Tin was the material of choice providing the best energy separation, non-toxicity, and non-reactiveness. The best soft-tissue-only image in the lung phantom was obtained using 0.3 mm tin and [140, 80] kVp pair. Dual-energy images of the Rando phantom had noticeable bone elimination when compared to no filtration. Dose was lower with tin filtering compared to no filtration. Conclusions: Dual-energy soft-tissue imaging is feasible using ExacTrac stereoscopic imaging system utilizing a single tin filter for both high and low energies and optimized acquisition parameters.

60 APPLIED LIFE SCIENCES↗

Effect of filter media thickness on the performance of sand drying beds used for faecal sludge management

Here the effect of sand filter media thickness on the performance of faecal sludge (FS) drying beds was determined in terms of: dewatering time, contaminant load removal efficiency, solids generation rate, nutrient content and helminth eggs viability in the dried sludge. A mixture of ventilated improved pit latrine sludge and septage in the ratio 1:2 was dewatered using three pilot-scale sludge drying beds with sand media thicknesses of 150, 250 and 350 mm. Five dewatering cycles were conducted and monitored for each drying bed. Although the 150 mm filter had the shortest average dewatering time of 3.65 days followed by 250 mm and 350 mm filters with 3.83 and 4.02 days, respectively, there was no significant difference (p > 0.05) attributable to filter media thickness configurations. However, there was a significant difference for the percolate contaminant loads in the removal and recovery efficiency of suspended solids, total solids, total volatile solids, nitrogen species, total phosphorus, chemical oxygen demand, dissolved chemical oxygen demand and biochemical oxygen demand, with the highest removal efficiency for each parameter achieved by the 350 mm filter. There were also significant differences in the nutrient content (NPK) and helminth eggs viability of the solids generated by the tested filters. Finally, filtering media configurations similar to 350 mm have the greatest potential for optimising nutrient recovery from FS.

54 ENVIRONMENTAL SCIENCES↗