Search NASA⌕ Search

SEARCH · Search NASA

Results for “guidelines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Measure Guideline: Guide to Attic Air Sealing

The purpose of this measure guideline is to provide information and recommendations for the preparation work necessary prior to adding attic insulation. Even though the purpose of this guide is to save energy, health, safety, and durability should not be compromised by energy efficiency. Accordingly, combustion safety and ventilation for indoor air quality are addressed first. Durability and attic ventilation then follow. Finally, to maximize energy savings, air sealing is completed prior to insulating. The guide is intended for home remodelers, builders, insulation contractors, mechanical contractors, general contractors who have previously done remodeling and homeowners as a guide to the work that needs to be done.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Strategy Guideline: Proper Water Heater Selection

This Strategy Guideline on proper water heater selection was developed by the Building America team Alliance for Residential Building Innovation to provide step-by-step procedures for evaluating preferred cost-effective options for energy efficient water heater alternatives based on local utility rates, climate, and anticipated loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Deep Energy Enclosure Retrofit for Interior Insulation of Masonry Walls

This Measure Guideline describes a deep energy enclosure retrofit (DEER) solution for insulating mass masonry buildings from the interior. It describes the retrofit assembly, technical details, and installation sequence for retrofitting masonry walls. Interior insulation of masonry retrofits has the potential to adversely affect the durability of the wall; this document includes a review of decision criteria pertinent to retrofitting masonry walls from the interior and the possible risk of freeze-thaw damage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Deep Energy Enclosure Retrofit for Zero Energy Ready House Flat Roofs

This Measure Guideline provides design and construction information for a deep energy enclosure retrofit (DEER) solution of a flat roof assembly. It describes the strategies and procedures for an exterior retrofit of a flat, wood-framed roof with brick masonry exterior walls, using exterior and interior (framing cavity) insulation. The approach supported in this guide could also be adapted for use with flat, wood-framed roofs with wood-framed exterior walls.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Deep Energy Enclosure Retrofit for Double-Stud Walls

This Measure Guideline describes a deep energy enclosure retrofit (DEER) solution that provides insulation to the interior of the wall assembly with the use of a double stud wall. The guide describes two approaches to retrofitting the existing the walls: one involving replacement of the existing cladding, and the other that leaves the existing cladding in place. It discusses the design principles related to the use of various insulation types, and provides strategies and procedures for implementing the double stud wall retrofit. It also evaluates important moisture-related and indoor air quality measures that need to be implemented to achieve a durable, high performance wall.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Implementing a Plenum Truss for a Compact Air Distribution System

This Measure Guideline presents the steps to implement a compact duct system inside an attic bulkhead (plenum truss) of a one-story, slab-on-grade home. In a compact duct design, ductwork runs are reduced in length to yield a smaller and more compact duct system. Less energy will be lost through ductwork if the ducts are contained within the thermal enclosure of the house. These measures are intended for the production builder working to meet the 2012 International Energy Conservation Code (IECC) requirements and keep the ductwork within the thermal enclosure of the house. This measure of bringing the heating, ventilation and air conditioning (HVAC) equipment and ductwork within the thermal enclosure of the house is appropriate for the builder wishing to avoid cathedralizing the insulation in the attic space (i.e., locating it at the underside of the roof deck rather than along the attic floor) or adding dropped soffits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Combustion Safety for Natural Draft Appliances Through Appliance Zone Isolation

This measure guideline covers how to assess and carry out the isolation of natural draft combustion appliances from the conditioned space of low-rise residential buildings. It deals with combustion appliances located either within the living space in enclosed closets or side rooms or outside the living space in an adjacent area like an attic or garage. This subset of houses does not require comprehensive combustion safety tests and simplified prescriptive procedures can be used to address safety concerns. This allows residential energy retrofit contractors inexperienced in advanced combustion safety testing to effectively address combustion safety issues and allow energy retrofits including tightening and changes to distribution and ventilation systems to proceed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Campaign Guidelines

This document establishes a common set of guidelines for the Atmospheric Radiation Measurement (ARM) Climate Research Facility for planning, executing, and closing out field campaigns. The steps that guide individual field campaigns are described in the Field Campaign Tracking System and are specifically tailored to meet the scope of each field campaign.

54 ENVIRONMENTAL SCIENCES↗

Measure Guideline. Passive Vents

This guideline is intended to be useful to designers, decision makers, and contractors who implement passive ventilation strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Temperature Salt Pump Review and Guidelines - Phase I Report

Fluoride salt cooled high-temperature reactor (FHR) concepts include pumps for forced circulation of the primary and secondary coolants. As part of a cooperative research and development agreement between the Shanghai Institute of Applied Physics and the Oak Ridge National Laboratory (ORNL), a research project was initiated to aid in the development of pumps for high-temperature salts. The objectives of the task included characterization of the behavior of an existing ORNL LSTL pump; design and test a modified impeller and volute for improved pump characteristics; and finally, provide lessons learned, recommendations, and guidelines for salt pump development and design. The pump included on the liquid salt test loop (LSTL) at ORNL served as a case study. This report summarizes the progress to date. The report is organized as follows. First, there is a review, focused on pumps, of the significant amount of work on salts at ORNL during the 1950s 1970s. The existing pump on the LSTL is then described. Plans for hot and cold testing of the pump are then discussed, including the design for a cold shakedown test stand and the required LSTL modifications for hot testing. Initial hydraulic and vibration modeling of the LSTL pump is documented. Later, test data from the LSTL will be used to validate the modeling approaches, which could then be used for future pump design efforts. Some initial insights and test data from the pump are then provided. Finally, some preliminary design goals and requirements for a future LSTL pump are provided as examples of salt pump design considerations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Mechanical Safety Subcommittee Guideline for Design of Thin Windows Regarding Roark’s Edge Condition Coefficient

An error was found in an edge stress coefficient used to calculate stresses in thin windows. This error is present in “Roark’s Formulas for Stress and Strain” 7th and 8th Edition. The 6th Edition is correct. This guideline specially discusses a major difference in regards to a coefficient used in calculating the edge stress in “Roark’s Formulas for Stress and Strain” 6th Edition compared to the 7th and 8th Editions. In Chapter 10: Flat Plates under “Circular plates under distributed load producing large deflections,” Case 3, which is “Fixed and held. Uniform pressure q over entire plate.” The coefficient for a fixed edge condition in the 6th Edition1 K4 = 0.476 while in the 7th and 8th Edition2, the coefficient is 1.73 which is significant difference.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quality Guideline for Energy System Studies: Cost Estimation Methodology for NETL Assessments of Power Plant Performance

This paper summarizes the cost estimation methodology employed by NETL in its assessment of power plant performance. A clear understanding of the methodology used is essential for allowing different power plant technologies to be compared on a similar basis. Though these guidelines are tailored for power plants, they can also be applied to a variety of different energy conversion plants (e.g., coal to liquids, syngas generation, hydrogen).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Guidelines for NSLS-II Beamline Enclosure Labyrinth Design

Penetrations for cables, pipes etc. through radiation shielded enclosures of the beamlines must be carefully designed to reduce potential exposures to personnel. This is most commonly done through labyrinths that eliminate lines of sight into the enclosures. Based upon the operational experience at other synchrotron radiation sources, we propose the following general guidelines for these labyrinths.

36 MATERIALS SCIENCE↗

Revised Guidelines for the NSLS-II Beamline Shielding Design

The annual dose to NSLS-II1 beamline scientists will be kept well below federal limits and within BNL administrative levels through shielding, operational procedures, and administrative controls. Shielding guidelines to the beamline design have been provided to reduce radiation levels external to the beamline enclosures during normal operation to <0.05 mrem/h and as low as reasonably achievable. Assuming occupancy of 2000 hours per year, this will reduce annual dose limit to the beamline scientists to 100 mrem or less.

36 MATERIALS SCIENCE↗

Quality Guideline for Energy System Studies: Process Modeling Design Parameters

The purpose of this section of the Quality Guidelines is to document the assumptions most commonly used in systems analysis studies and the basis for those assumptions. The large number of assumptions required for a thorough systems analysis make it impractical to document the entire set in each report. This document will serve as a comprehensive reference for these assumptions as well as their justification.

42 ENGINEERING↗

Quality Guidelines for Energy System Studies: Cost Estimation Methodology for NETL Assessments of Power Plant Performance

This paper summarizes the costing methodology employed by the National Energy Technology Laboratory (NETL) in its costing models and baseline reports. Further, it defines the specific levels of capital cost as well as outlines the costing metrics by which NETL evaluates various power producing plants. These metrics and a clear understanding of the methodology used are essential in allowing different power plant technologies to be compared on a similar basis. Though these guidelines are tailored for power producing plants, they can also be applied to a variety of different revenue generating plants (e.g., coal to liquids, syngas generation, hydrogen).

20 FOSSIL-FUELED POWER PLANTS↗