Search NASA⌕ Search

SEARCH · Search NASA

Results for “hardware testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Testing and Analysis of Grid Forming Inverter Control for Achieving Resilient and Economic Operation of an Islanded Microgrid

This investigation examines the feasibility of operating a battery energy storage system (BESS) in parallel with synchronous generation by using grid forming (GFM) control in order to achieve frequency control objectives while mitigating increases to operating costs in the context of an islanded microgrid. The BESS GFM control system, which is based on conventional droop techniques, is modeled along with the overall microgrid using the Real Time Digital Simulator (RTDS) to allow for integration of genset controller hardware. A series of simulations are performed to test the voltage and frequency regulation capability of the BESS control system when the primary frequency regulating genset is tripped offline. The results of the simulations suggest that the GFM control scheme will successfully maintain frequency and voltage stability, which will enable operation without a back-up genset while not compromising the microgrid resiliency to contingencies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Porting the Kitten Lightweight Kernel Operating System to RISC-V

Hardware design in high-performance computing (HPC) is often highly experimental. Exploring new designs is difficult and time-consuming, requiring lengthy vendor cooperation. RISC-V is an open-source processor ISA that improves the accessibility of chip design, including the ability to do hardware/software co-design using open-source hardware and tools. Co-design allows design decisions to easily flow across the hardware/software boundary and influence future design ideas. However, new hardware designs require corresponding software to drive and test them. Conventional operating systems like Linux are massively complex and modification is time-prohibitive. In this paper, we describe our port of the Kitten lightweight kernel operating system to RISC-V in order to provide an alternative to Linux for conducting co-design research. Kitten's small code base and simple resource management policies are well matched for quickly exploring new hardware ideas that may require radical operating system modifications and restructuring. Our evaluation shows that Kitten on RISC-V is functional and provides similar performance to Linux for single-core benchmarks. This provides a solid foundation for using Kitten in future co-design research involving RISC-V.

Gordon, Nick↗

Modeling and Feedback Compensator Design for Power-Hardware-in-the-Loop System for Medium-Voltage Grid-Connected Power Converters

Hardware-in-the-loop (HIL) evaluation is a method in which the test subject is split into a physical part and a simulated part, and these parts are connected with interfaces to form a combined physical-numerical system. Power-hardware-in-the-loop (PHIL) systems, where actual hardware is connected to a real-time model, can exhibit issues of instability, inaccuracy and errors when operating in a closed-loop. The challenges of generating a PHIL setup are that, first, because of the limited dynamic response of the different parts of the system, the test results might be inaccurate, and, second, because of the high frequency noise introduced by the sensors to the closed-loop system, it can be difficult to design a compensator for the real-time emulator response, while stabilizing the closed-loop system at the same time. In this paper, different parts of a PHIL system are characterized, and the feedback compensator system design is proposed for the stable operation of the closed-loop PHIL system. The issues as observed in a PHIL system without any compensator are demonstrated using experimental results, and the effectiveness of a first order phase lead compensator is validated.

compensator design↗

Ground Motion Inputs for the Seismic Shake Table Test

Currently, spent nuclear fuel (SNF) is stored in on-site independent spent-fuel storage installations (ISFSIs) at seventythree (73) nuclear power plants (NPPs) in the US. Because a site for geologic repository for permanent disposal of SNF has not been constructed, the SNF will remain in dry storage significantly longer than planned. During this time, the ISFSIs, and potentially consolidated storage facilities, will experience earthquakes of different magnitudes. The dry storage systems are designed and licensed to withstand large seismic loads. When dry storage systems experience seismic loads, there are little data on the response of SNF assemblies contained within them. The Spent Fuel Waste Disposition (SFWD) program is planning to conduct a full-scale seismic shake table test to close the gap related to the seismic loads on the fuel assemblies in dry storage systems. This test will allow for quantifying the strains and accelerations on surrogate fuel assembly hardware and cladding during earthquakes of different magnitudes and frequency content. The main component of the test unit will be the full-scale NUHOMS 32 PTH2 dry storage canister. The canister will be loaded with three surrogate fuel assemblies and twenty-nine dummy assemblies. Two dry storage configurations will be tested – horizontal and vertical above-ground concrete overpacks. These configurations cover 91% of the current dry storage configurations. The major input into the shake table test are the seismic excitations or the earthquake ground motions – acceleration time histories in two horizontal and one vertical direction that will be applied to the shake table surface during the tests. The shake table surface represents the top of the concrete pad on which a dry storage system is placed. The goal of the ground motion task is to develop the ground motions that would be representative of the range of seismotectonic and other conditions that any site in the Western US (WUS) or Central Eastern US (CEUS) might entail. This task is challenging because of the large number of the ISFSI sites, variety of seismotectonic and site conditions, and effects that soil amplification, soil-structure interaction, and pad flexibility may have on the ground motions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Residential PV-Energy Storage Testing Collaboration with SunPower: Cooperative Research and Development Final Report, CRADA Number CRD-14-569

Residential scale energy storage devices have shown great promise to add value and improve the ability to integrate distributed and variable generation into the distribution grid. Battery energy storage systems combined with PV and advanced inverters can provide many services. These include extended backup power in case of grid failure, reductions in feeder and system level peak load, system level net load ramp reduction, grid management services both locally (e.g., voltage management) and bulk system (e.g., reserves) level, and improved grid reliability through grid voltage and frequency support. Even though the cost of the energy storage systems are decreasing, one of the main challenges related to the widespread deployment of energy storage, as found by the U.S. Department of Energy (DOE), is utility acceptance of storage technologies. Various interconnection challenges exist when connecting distributed PV-energy storage into the electrical distribution grid in terms of safety, reliability and stability of the electric power systems. Some of the urgent challenges, as seen by the manufacturers and installers are: safety of the battery cells and the packs, performance of the power conversion systems, effect of bidirectional power flow on existing utility equipment and qualification of solutions such as volt-ampere reactive (VAR) support and frequency regulation. Under this project, National Renewable Energy Laboratory (NREL) researchers will work with SunPower to address these challenges by research, testing and analysis at Energy System Integration Facility (ESIF) and energy storage testing laboratory at NREL. NREL's unique power hardware-in-the-loop (PHIL) capability will be utilized to evaluate system-level issues such as reverse power flow and VAR support (if available) for these PV-energy storage systems. Through the analysis of test results, the proposed project will demonstrate use of ESIF capabilities in a way that advances both the DOE and SunPower's goals of moving clean, renewable energy technologies onto the electrical grid.

14 SOLAR ENERGY↗

Modeling and Power-Hardware-in-the-Loop Validation of Synchronous Wind: An Inverterless Grid-Forming Wind Power Plant: Preprint

Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators has attracted substantial attention in power systems research; however, the limited over-current capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also known as Type-5 wind turbine generator (WTG), offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high penetration levels of renewable generation. A Type-5 WTG interfaces to the electric grid via a synchronous generator (SG) driven by a variable-speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation and the generator shaft remains synchronous to the grid. This paper developed and tested a high-fidelity model of Type-5 WTG under power-hardware-in-the-loop (PHIL) testing environment. The PHIL demonstration showed that a Type-5 WTGs inherently behaves as a GFM unit and can obtain similar performance in terms of power responses, wind rotor dynamics, and efficiency compared to Type-3 WTG in high wind conditions. The developed model also provides further insight on how Type-5 WTGs can benefit the smooth transition to power systems with high integration level of inverter-based resources.

grid strength↗

Characterization of UMT2013 Performance on Advanced Architectures

This paper presents part of a larger effort to make detailed assessments of several proxy applications on various advanced architectures, with the eventual goal of extending these assessments to codes of programmatic interest running more realistic simulations. The focus here is on UMT2013, a proxy implementation of deterministic transport for unstructured meshes. I present weak and strong MPI scaling results and studies of OpenMP efficiency on the Sequoia BG/Q system at LLNL, with comparison against similar tests on an Intel Sandy Bridge TLCC2 system. The hardware counters on BG/Q provide detailed information on many aspects of on-node performance, while information from the mpiP tool gives insight into the reasons for the differing scaling behavior on these two different architectures. Preliminary tests that exploit NVRAM as extended memory on an Ivy Bridge machine designed for “Big Data” applications are also included.

97 MATHEMATICS AND COMPUTING↗

Voltage Regulation Performance Evaluation of Distributed Energy Resource Management via Advanced Hardware-in-the-Loop Simulation

This paper evaluates the performance of coordinated control across advanced distribution management systems (ADMS), distributed energy resources (DERs), and distributed energy resource management systems (DERMS) using an advanced hardware-in-the-loop (HIL) platform. This platform provides a realistic laboratory testing environment, including accurate dynamic modeling of a real-world distribution system from a utility partner, real controllers (ADMS and DERMS), physical power hardware (DERs), and standard communications protocols. One grid service—voltage regulation—is evaluated to show the performance of the coordinated grid automation system. The testing results demonstrate that the coordinated DERMS and ADMS system can effectively regulate system voltages within target operation limits using DERs. The realistic laboratory HIL testing results give utilities confidence in adopting the grid automation systems to manage DERs to achieve system-level control and operation objectives (e.g., voltage regulation). This helps utilities mitigate potential risks (e.g., instability) prior to field deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

National Security Programs - Cyber: MMAREJBLIGE – Modular Multi Agent Grid Emulation for Joined Breakdowns in Linked Generative Emulations - 23-0644

Modular Multi Agent Grid Emulations for Joined Breakdowns in Linked Generative Emulations (MMAREJBLIGE) introduces an agent-based modeling framework into real-time cyber-physical emulation to achieve a context-aware environment that introduces operator/attacker/external-condition variability to improve emulation fidelity and testing rigor. We detail our agent framework design, internal communication via message passing, and time synchronization, as well as the individual components of the system. We include a brief analysis of several scenarios run on a real-time, hardware-in-the-loop, Industrial Control Systems (ICS) test-bed which include normal operation, physical disruption, disruption with mitigation, and disruption with mitigation during a cyber denial-of-service (DOS) attack.

42 ENGINEERING↗

Characterization of Proxy Application Performance on Advanced Architectures. UMT2013, MCB, AMG2013

Three codes were tested at LLNL as part of a Tri-Lab effort to make detailed assessments of several proxy applications on various advanced architectures, with the eventual goal of extending these assessments to codes of programmatic interest running more realistic simulations. Teams from Sandia and Los Alamos tested proxy apps of their own. The focus in this report is on the LLNL codes UMT2013, MCB, and AMG2013. We present weak and strong MPI scaling results and studies of OpenMP efficiency on a large BG/Q system at LLNL, with comparison against similar tests on an Intel Sandy Bridge TLCC2 system. The hardware counters on BG/Q provide detailed information on many aspects of on-node performance, while information from the mpiP tool gives insight into the reasons for the differing scaling behavior on these two different architectures. Results from three more speculative tests are also included: one that exploits NVRAM as extended memory, one that studies performance under a power bound, and one that illustrates the effects of changing the torus network mapping on BG/Q.

97 MATHEMATICS AND COMPUTING↗

Power Hardware-in-the-Loop-Based Anti-Islanding Evaluation and Demonstration

The National Renewable Energy Laboratory (NREL) teamed with Southern California Edison (SCE), Clean Power Research (CPR), Quanta Technology (QT), and Electrical Distribution Design (EDD) to conduct a U.S. Department of Energy (DOE) and California Public Utility Commission (CPUC) California Solar Initiative (CSI)-funded research project investigating the impacts of integrating high-penetration levels of photovoltaics (PV) onto the California distribution grid. One topic researched in the context of high-penetration PV integration onto the distribution system is the ability of PV inverters to (1) detect islanding conditions (i.e., when the distribution system to which the PV inverter is connected becomes disconnected from the utility power connection) and (2) disconnect from the islanded system within the time specified in the performance specifications outlined in IEEE Standard 1547. This condition may cause damage to other connected equipment due to insufficient power quality (e.g., over-and under-voltages) and may also be a safety hazard to personnel that may be working on feeder sections to restore service. NREL teamed with the Florida State University (FSU) Center for Advanced Power Systems (CAPS) to investigate a new way of testing PV inverters for IEEE Standard 1547 unintentional islanding performance specifications using power hardware-in-loop (PHIL) laboratory testing techniques.

14 SOLAR ENERGY↗

Hawaiian Electric Advanced Inverter Test Plan - Result Summary

This presentation is intended to share the results of lab testing of five PV inverters with the Hawaiian Electric Companies and other stakeholders and interested parties. The tests included baseline testing of advanced inverter grid support functions, as well as distribution circuit-level tests to examine the impact of the PV inverters on simulated distribution feeders using power hardware-in-the-loop (PHIL) techniques. hardware-in-the-loop (PHIL) techniques.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Test results of an ITER relevant FPGA when irradiated with neutrons

The data acquisition and control instrumentation cubicles room of the ITER tokamak will be irradiated with neutrons during the fusion reactor operation. A Virtex-6 FPGA from Xilinx (XC6VLX365T-1FFG1156C) is used on the ATCA-IO-PROCESSOR board, included in the ITER Catalog of I and C products - Fast Controllers. The Virtex-6 is a re-programmable logic device where the configuration is stored in Static RAM (SRAM), functional data stored in dedicated Block RAM (BRAM) and functional state logic in Flip-Flops. Single Event Upsets (SEU) due to the ionizing radiation of neutrons causes soft errors, unintended changes (bit-flips) to the values stored in state elements of the FPGA. The SEU monitoring and soft errors repairing, when possible, were explored in this work. An FPGA built-in Soft Error Mitigation (SEM) controller detects and corrects soft errors in the FPGA configuration memory. Novel SEU sensors with Error Correction Code (ECC) detect and repair the BRAM memories. Proper management of SEU can increase reliability and availability of control instrumentation hardware for nuclear applications. The results of the tests performed using the SEM controller and the BRAM SEU sensors are presented for a Virtex-6 FPGA (XC6VLX240T-1FFG1156C) when irradiated with neutrons from the Portuguese Research Reactor (RPI), a 1 MW nuclear fission reactor operated by IST in the neighborhood of Lisbon. Results show that the proposed SEU mitigation technique is able to repair the majority of the detected SEU errors in the configuration and BRAM memories. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SRF Cavity Emulator for PIP-II LLRF Lab and Field Testing

There are many stages in the LLRF and RF system development process for any new accelerator that can take advantage of hardware emulation of the high-power RF system and RF cavities. LLRF development, bench testing, control system development and testing of installed systems must happen well before SRF cavities are available for test. The PIP-II Linac has three frequencies of SRF cavities, 162.5 MHz, 325 MHz and 650 MHz and a simple analog emulator design has been chosen that can meet the cavity bandwidth requirements, provide tuning errors to emulate Lorentz force detuning and microphonics for all cavity types. This emulator design utilizes a quartz crystal with a bandwidth of 65Hz at an IF of ~ 4 MHz, providing a Q of ~ 1.3 x 10^7 at 650MHz. This paper will discuss the design and test results of this emulator.

43 PARTICLE ACCELERATORS↗

SU-F-T-218: Validation of An In-Vivo Proton Range Verification Method for Reducing the Risk of Permanent Alopecia in the Treatment of Pediatric Medulloblastoma

Purpose: The clinical commissioning of a workflow for pre-treatment range verification/adjustment for the head treatment of pediatric medulloblastoma patients, including dose monitoring during treatment. Methods: An array of Si-diodes (DIODES Incorporated) is placed on the patient skin on the opposite side to the beam entrance. A “scout” SOBP beam, with a longer beam range to cover the diodes in its plateau, is delivered; the measured signal is analyzed and the extracted water equivalent path lengths (WEPL) are compared to the expected values, revealing if a range correction is needed. Diodes stay in place during treatment to measure dose. The workflow was tested in solid water and head phantoms and validated against independent WEPL measurements. Both measured WEPL and skin doses were compared to computed values from the TPS (XiO); a Markus chamber was used for reference dose measurements. Results: The WEPL accuracy of the method was verified by comparing it with the dose extinction method. It resulted, for both solid water and head phantom, in the sub-millimeter range, with a deviation less than 1% to the value extracted from the TPS. The accuracy of dose measurements in the fall-off part of the dose profile was validated against the Markus chamber. The entire range verification workflow was successfully tested for the mock-treatment of head phantom with the standard delivery of 90 cGy per field per fraction. The WEPL measurement revealed no need for range correction. The dose measurements agreed to better than 4% with the prescription dose. The robustness of the method and workflow, including detector array, hardware set and software functions, was successfully stress-tested with multiple repetitions. Conclusion: The performance of the in-vivo range verification system and related workflow meet the clinical requirements in terms of the needed WEPL accuracy for pretreatment range verification with acceptable dose to the patient.

60 APPLIED LIFE SCIENCES↗

Open-Source Framework for Data Storage and Visualization of Real-Time Experiments

Digital real time simulators (DRTS) are increasingly being used for the evaluation of power hardware and controller hardware in the laboratory prior to field deployment. Although DRTS are capable of simulating large models in real-time, it is challenging to visualize the results of large models without overdrawing or confounding the viewer. This paper provides an open-source framework for users to visualize their DRTS-based hardware-in-the-loop (HIL) experimental results in real-time. This proposed framework can be used by experimental test beds that can push data through an internet protocol based network. The proposed framework includes three main components. First, it includes the DRTS that generates and pushes the data to a relay. Second, it includes an application that serves multiple purposes, from data storage, testing, and translation of the data to a publisher/subscriber protocol. Finally, it includes libraries and applications that can be used to visualize the data by subscribing to the relay. This framework is available in open source, and it is tested using the HIL platform developed for testing advanced distribution management systems.

advanced distribution management systems↗

Balancing Impedance and Controllability in Response Reconstruction with $\mathrm{TS-IMMAT}$

In a prior work the authors proposed a variant on the Impedance Matched Multi-Axis Test (IMMAT) in which a fixture is defined, called the Transmission Simulator (TS), and the desired environment is matched at a set of sensors on the TS. If the motion of the TS is matched then the response of the rest of the component will also match, provided that the attached component has the same dynamics as it did when the environment was measured. Hence, one would like the TS to be flexible so that it reproduces the boundary conditions that the component of interest experiences during flight, but the more flexible the TS, the more shakers might be needed to control its response. This work presents a derivation that gives expressions for these two potential error sources in TS-IMMAT. Then, various case studies are presented, both on simulated and real hardware, to understand the importance of each error term in practical testing. The theory explains the phenomena that were observed when using measurements from a component that flew on a sounding rocket. The environmental response was measured and then various fixtures were attached, each comprising more of the next assembly, or the hardware to which the component was attached in flight. MIMO testing was repeated with each fixture and the results were compared to seek to understand the role of the impedance match in this type of testing. Here the results show that the number of modes that are active in the transmission simulator is also very important, and so the best solution balances these two considerations. An improved method of simulating the MIMO test is then proposed, so simulations can be used to predict what fixture, or transmission simulator, will give the best results in a TS-IMMAT test.

42 ENGINEERING↗

Commissioning the JLab LERF Cryomodule Test Facility

The JLab Low Energy Recirculating Facility, LERF, has been modified to support concurrent testing of two LCLS-II cryomodules. The cryomodules are installed in a similar fashion as they would be in the L1 section of the LCLS-II linac, including the floor slope and using all of the LCLS-II hardware and controls for cryomodule cryogenics, vacuum, and RF (SSA and LLRF). From the start, it was intended to use LCLS-II electronics and EPICS software controls for cryomodule testing. In affect the LERF test facility becomes the first opportunity to commission and operate the LCLS-II LINAC hardware and software controls. Support for specific cryomodule high level test applications like Q0 and HOMs measurements, are being developed from the basic cryomodule control suite. To support the testing, 2 K He is supplied from the CEBAF south linac cryogenic system, where care must be taken when using the LERF test facility to not upset the CEBAF cryogenics plant. This paper discusses the commissioning of the hardware and software development for testing the first two LCLS-II cryomodules.

Hovater, C.↗