Search NASA⌕ Search

SEARCH · Search NASA

Results for “hydrogen detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Pd/CeO2/SiC Chemical Sensors

The incorporation of nanostructured interfacial layers of CeO2 has been proposed to enhance the performances of Pd/SiC Schottky diodes used to sense hydrogen and hydrocarbons at high temperatures. If successful, this development could prove beneficial in numerous applications in which there are requirements to sense hydrogen and hydrocarbons at high temperatures: examples include monitoring of exhaust gases from engines and detecting fires. Sensitivity and thermal stability are major considerations affecting the development of high-temperature chemical sensors. In the case of a metal/SiC Schottky diode for a number of metals, the SiC becomes more chemically active in the presence of the thin metal film on the SiC surface at high temperature. This increase in chemical reactivity causes changes in chemical composition and structure of the metal/SiC interface. The practical effect of the changes is to alter the electronic and other properties of the device in such a manner as to degrade its performance as a chemical sensor. To delay or prevent these changes, it is necessary to limit operation to a temperature <450 C for these sensor structures. The present proposal to incorporate interfacial CeO2 films is based partly on the observation that nanostructured materials in general have potentially useful electrical properties, including an ability to enhance the transfer of electrons. In particular, nanostructured CeO2, that is CeO2 with nanosized grains, has shown promise for incorporation into hightemperature electronic devices. Nanostructured CeO2 films can be formed on SiC and have been shown to exhibit high thermal stability on SiC, characterized by the ability to withstand temperatures somewhat greater than 700 C for limited times. The exchanges of oxygen between CeO2 and SiC prevent the formation of carbon and other chemical species that are unfavorable for operation of a SiC-based Schottky diode as a chemical sensor. Consequently, it is anticipated that in a Pd/CeO2/SiC Schottky diode, the nanostructured interfacial CeO2 layer would contribute to thermal stability and, by contributing to transfer of electrons, would also contribute to sensitivity.

Lu, Weijie↗

Coated or doped carbon nanotube network sensors as affected by environmental parameters

Methods for using modified single wall carbon nanotubes ("SWCNTs") to detect presence and/or concentration of a gas component, such as a halogen (e.g., Cl.sub.2), hydrogen halides (e.g., HCl), a hydrocarbon (e.g., C.sub.nH.sub.2n+2), an alcohol, an aldehyde or a ketone, to which an unmodified SWCNT is substantially non-reactive. In a first embodiment, a connected network of SWCNTs is coated with a selected polymer, such as chlorosulfonated polyethylene, hydroxypropyl cellulose, polystyrene and/or polyvinylalcohol, and change in an electrical parameter or response value (e.g., conductance, current, voltage difference or resistance) of the coated versus uncoated SWCNT networks is analyzed. In a second embodiment, the network is doped with a transition element, such as Pd, Pt, Rh, Ir, Ru, Os and/or Au, and change in an electrical parameter value is again analyzed. The parameter change value depends monotonically, not necessarily linearly, upon concentration of the gas component. Two general algorithms are presented for estimating concentration value(s), or upper or lower concentration bounds on such values, from measured differences of response values.

Li, Jing↗

Air Monitoring for Hazardous Gas Detection

The Hazardous Gas Detection Lab (HGDL) at Kennedy Space Center is involved in the design and development of instrumentation that can detect and quantify various hazardous gases. Traditionally these systems are designed for leak detection of the cryogenic gases used for the propulsion of the Shuttle and other vehicles. Mass spectrometers are the basis of these systems, which provide excellent quantitation, sensitivity, selectivity, response times and detection limits. A Table lists common gases monitored for aerospace applications. The first five gases, hydrogen, helium, nitrogen, oxygen, and argon are historically the focus of the HGDL.

Arkin, C. Richard↗

Liquid Acquisition Device Hydrogen Outflow Testing on the Cryogenic Propellant Storage and Transfer Engineering Design Unit

As part of the NASA Cryogenic Propellant Storage and Transfer (CPST) Engineering Design Unit (EDU) testing with liquid hydrogen, screen-channel liquid acquisition devices (LADs) were tested during liquid hydrogen outflow from the EDU tank. A stainless steel screen mesh (325x2300 Dutch T will weave) was welded to a rectangular cross-section channel to form the basic LAD channel. Three LAD channels were tested, each having unique variations in the basic design. The LADs fed a common outflow sump at the aft end of the 151 cu. ft. volume aluminum tank, and included a curved section along the aft end and a straight section along the barrel section of the tank. Wet-dry sensors were mounted inside the LAD channels to detect when vapor was ingested into the LADs during outflow. The use of warm helium pressurant during liquid hydrogen outflow, supplied through a diffuser at the top of the tank, always led to early breakdown of the liquid column. When the tank was pressurized through an aft diffuser, resulting in cold helium in the ullage, LAD column hold-times as long as 60 minutes were achieved, which was the longest duration tested. The highest liquid column height at breakdown was 58 cm, which is 23 less than the isothermal bubble-point model value of 75 cm. This paper discusses details of the design, construction, operation and analysis of LAD test data from the CPST EDU liquid hydrogen test.

Liquid hydrogen↗

Crowd-Sourced Technology Challenge for Improving Visual Color Detection of Hydrazine and Monomethylhydrazine Vapors in Spacecraft Environments

NASA currently uses a visual colorimetric detection method for potential hydrazine, monomethylhydrazine (MMH), or unsymmetrical dimethylhydrazine (UDMH) contamination in the International Space Station. Astronauts exposed to propellants or their residues during extravehicular activities may transfer contaminants into the airlock. The colorimetric detection method employs the Contamination Detection Kit (CDK), which uses a potassium tetrachloroaurate redox reaction with the propellant hydrazine vapors and a color comparison card to determine airborne concentrations. Seeking ideas for improvement, the NASA Tournament Lab (NTL) crowdsourced a way to tackle the challenge of detecting hydrazine and MMH vapors using colorimetric detection methods. This Rid the Rocket competition drew over 200 participants and 20 submissions from around the world proposing innovative ways to develop a new chemical colorimetric detection method for hydrazine and MMH vapors on spacecraft. Using a phased approach to evaluate contestants, NASA eventually narrowed the field to five finalists from the United States, Romania, Taiwan, and India. Concept papers and hardware submissions were judged on feasibility, creativity, and ability to detect hydrazine and MMH vapors before being sent to the NASA White Sands Test Facility for laboratory evaluation. Finalists employed variations of sampling methods and color-detection chemistry using a variety of sampling pumps and indicator pads or solutions—including those employing potassium or hydrogen tetrachloroaurate, para -dimethylaminobenzaldehyde (PDAB), and modifiers including sodium metasilicate and cetyltrimethylammonium bromide—to enhance gold nanoparticle formation and surface plasmon resonance (SPR) resulting in visual blue to purple color development. This paper presents a summary of the crowdsourced submissions and results of laboratory testing.

Crowd-Sourced↗

Measurement component technology. Volume 1: Cryogenic pressure measurement technology, high pressure flange seals, hydrogen embrittlement of pressure transducer material, close coupled versus remote transducer installation and temperature compensation of pressure transducers

The results are presented of an investigation into the availability and performance capability of measurement components in the area of cryogenic temperature, pressure, flow and liquid detection components and high temperature strain gages. In addition, technical subjects allied to the components were researched and discussed. These selected areas of investigation were: (1) high pressure flange seals, (2) hydrogen embrittlement of pressure transducer diaphragms, (3) The effects of close-coupled versus remote transducer installation on pressure measurement, (4) temperature transducer configuration effects on measurements, and (5) techniques in temperature compensation of strain gage pressure transducers. The purpose of the program was to investigate the latest design and application techniques in measurement component technology and to document this information along with recommendations for upgrading measurement component designs for future S-2 derivative applications. Recommendations are provided for upgrading existing state-of-the-art in component design, where required, to satisfy performance requirements of S-2 derivative vehicles.

Hayakawa, K. K.↗

Titan's hydrogen torus

A model of Titan's hydrogen torus, capable of describing its time evolution under the influence of the gravitational fields of both the satellite and the planet, is presented. Estimated lifetimes for hydrogen atoms near Titan's orbit of the order of 10 to the 7th s, based on recent Pioneer 11 measurements, suggest that the torus completely encircles Saturn and is angularly unsymmetric, having an enhanced gas density near the satellite. New model calculations confirm this and provide an explanation for the torus detected by the Copernicus satellite and the UV instrument of Pioneer 11. Agreement between calculated and observed Lyman alpha intensities suggests a hydrogen escape flux between 1 x 10 to the 9th/sq cm-s and 3 x 10 to the 9th/sq cm-s should be operative at Titan. This produces a torus containing some 10 to the 34th hydrogen atoms.

Smyth, W. H.↗

A Lyman-alpha tunable acousto-optic filter for detecting superthermal flare protons

The goal of this project was to develop and characterize a narrow-band, tunable filter for use near the Lyman-alpha line of hydrogen at 121.6 nm. Such a filter could form the critical component of an instrument to observe asymmetries in the solar Lyman-alpha line, caused by energetic protons accelerated during the impulsive phase of solar flares. Characteristic charge-exchange nonthermal emission at Lyman alpha should be produced when sub-MeV protons are injected into the chromosphere, but no instrument suitable for their detection has been developed. Such an instrument would require a narrow-band (less than 0.01 nm) tunable filter with aperture and throughput consistent with imaging a solar active region at 0.1 second intervals. The development of acousto-optic tunable filters (AOTF) suitable for use as compact, simple tunable filters for astronomical work suggested an investigation into the use of an AOTF at Lyman-alpha.

Mickey, Donald L.↗

Replica-based Crack Inspection

A surface replica-based crack inspection method has recently been developed for use in Space Shuttle main engine (SSME) hydrogen feedline flowliners. These flowliners exist to ensure favorable flow of liquid hydrogen over gimble joint bellows, and consist of two rings each containing 38 elongated slots. In the summer of 2002, multiple cracks ranging from 0.1 inches to 0.6 inches long were discovered; each orbiter contained at least one cracked flowliner. These long cracks were repaired and eddy current inspections ensured that no cracks longer than 0.075 inches were present. However, subsequent fracture-mechanics review of flight rationale required detection of smaller cracks, and was the driving force for development of higher-resolution inspection method. Acetate tape surface replicas have been used for decades to detect and monitor small cracks. However, acetate tape replicas have primarily been limited to laboratory specimens because complexities involved in making these replicas - requiring acetate tape to be dissolved with acetone - are not well suited for a crack inspection tool. More recently developed silicon-based replicas are better suited for use as a crack detection tool. A commercially available silicon-based replica product has been determined to be acceptable for use in SSME hydrogen feedlines. A method has been developed using this product and a scanning electron microscope for analysis, which can find cracks as small as 0.005 inches and other features (e.g., pits, scratches, tool marks, etc.) as small as 0.001 inches. The resolution of this method has been validated with dozens of cracks generated in a laboratory setting and this method has been used to locate 55 cracks (ranging in size from 0.040 inches to 0.004 inches) on space flight hardware. These cracks were removed by polishing away the cracked material and a second round of replicas confirmed the repair.

Newman, John A.↗

Measuring Hydrogen Plumes With Raman Lidar

Prototype Raman lidar system measures concentration of hydrogen gas in atmosphere as function of position, with range resolution of 3 ft over 3,000 ft. Sensitive to concentrations smaller than 0.5 percent, 10 times below minimum flammable concentration. Pulsed ultraviolet laser beam excites Raman emissions from molecules to be detected. Backscattered light collected by telescope, filtered at appropriate wavelengths, and sent to photodetectors. Developed for use as safety monitor, and to study dispersion of hydrogen gas leaking into atmosphere.

Caputo, Bernard↗

How to find galaxies at high redshift

The UV and optical spectra presented for the blue star-forming galaxies Mrk 357, Mrk 496, and Mrk 26 have sufficiently large redshifts to make Lyman-alpha observations possible. Weak Lyman-alpha emission is observed in Mrk 357 and Mrk 469, with a flux value comparable to that of H-beta, and no detectable Lyman-alpha emission is detected in the case of Mrk 26. All three objects exhibit strong UV continuum emission, which is characteristic of hot stars, and although little evidence of dust is found, the observational constraints on extinction and neutral hydrogen column densities allow substantial reductions of the Lyman-alpha flux by dust absorption in conjunction with large line optical depths. These results imply that primeval galaxy detection calls for attention to be given to redshifted continuum emission from massive galaxies.

Hartmann, L. W.↗

Atmospheric Hydroperoxides in West Antarctica: Links to Stratospheric Ozone and Atmospheric Oxidation Capacity

The troposphere above the West Antarctic Ice Sheet (WAIS) was sampled for hydroperoxides at 21 locations during 2-month-long summer traverses from 2000 to 2002, as part of US ITASE (International Transantarctic Scientific Expedition). First time quantitative measurements using an HPLC method showed that methylhydroperoxide (MHP) is the only important organic hydroperoxide occurring in the Antarctic troposphere, and that it is found at levels ten times those previously predicted by photochemical models. During three field seasons, means and standard deviations for hydrogen peroxide (H2O2) were 321+/-158 pptv, 650+/-176 pptv and 330+/-147 pptv. While MHP was detected, but not quantified in December 2000, levels in summer 2001 and 2002 were 317+128 pptv and 304+/-172.2 pptv. Results from firn air experiments and diurnal variability of the two species showed that atmospheric H2O2 is significantly impacted by a physical snow pack source between 76 and 90degS, whereas MHP is not. We show strong evidence of a positive feedback between stratospheric ozone and H2O2 at the surface. Between November-27 and December-12 in 2001, when ozone column densities dropped below 220 DU (means in 2000 and 2001 were 318 DU and 334 DU, respectively), H2O2 was 1.7 times that observed in the same period in 2000 and 2002, while MHP was only 80% of the levels encountered in 2002. Photochemical box model runs suggest that NO and OH levels on WAIS are closer to coastal values, while Antarctic Plateau levels are higher, confirming that region to be a highly oxidizing environment. The modeled sensitivity of H2O2 and particularly MHP to NO offers the potential to use atmospheric hydroperoxides to constrain the NO background and thus estimate the past oxidation capacity of the remote atmosphere. Index Terms: 0365 Atmospheric Composition and Structure: Troposphere: composition and chemistry; 0322 Atmospheric Composition and Structure: Constituent sources and sinks; 1610 Global Change: Atmosphere (03 15,0325); 0736 Cryosphere: Snow (1827, 1863); 0724 Cryosphere: Ice Cores (4932) Keywords: hydrogen peroxide, methylhydroperoxide, Antarctica, air-snow exchange, stratospheric ozone, atmospheric oxidation capacity

Frey, Markus M.↗

Experimental limits on the velocities of sodium atoms sputtered from solid surfaces by hydrogen ions

Optical emission at 589.0 nm by sodium atoms sputtered from solid targets by hydrogen molecular ions was observed, and no accompanying broadening or shifts of this line could be detected relative to that from a laboratory lamp. This allowed an upper limit of about 500,000 cm/sec on the mean speed of ejected sodium atoms to be calculated. The results are consistent with the hypothesis that the atomic sodium cloud surrounding Io is produced by this mechanism.

Stoner, J. O., Jr.↗

The effective temperature of the white-dwarf star and ZZ Ceti candidate Wolf 485A

Previous multichannel observations of W485A (WD 1327-08) have placed it in the instability strip, the effective temperature range 11,000-13,000 K. In the instability strip, most of the stars (the ZZ Ceti stars) are variable, but W485A has not been detected to be variable. In this paper, high-resolution spectra of W485A and improved hydrogen-line broadening routines are used in the ATLAS model-atmospheres program to find the temperature of W485A; the estimate of effective temperature most consistent with the other data on the star is 14,600 K, outside the instability strip.

Digel, S. W.↗

Experimental study of planetary gases with applications to planetary interior models

High-pressure experimental data on planetary materials are critical in developing planetary models and in addressing otherwise insoluble problems of the internal structure of the major planets. Progress in the last five years has been particularly marked. Maximum static pressure of 550 GPa was achieved. For the first time, X-ray diffraction of solidified gases (Ne, Xe) and ices (H2O) were obtained at pressures above one megabar, single-crystal diffraction of ultralight elements (H2, He) were detected up to 25 GPa, pressures over 200 GPa at 77 K were reached in solid hydrogen, including the discovery of a phase transformation in the molecular solid. Advances in instrumentation and new measurements performed during 1983 to 1988 are summarized.

Bell, Peter M.↗

The Galactic far ultraviolet background

Investigations of the FUV background are discussed in the light of the methods employed and significant results of data interpretation. Attention is given to the data that confirm the generally accepted theory that the FUV flux originates in the Galaxy. The relationship between the flux measurements and the types of scattering by dust are investigated with attention given to the discrepancies inherent in reported scattering properties. Recent evidence shows wide ranges of albedo values and scattering-phase functions, and UV scattering grains are noted in all directions of the Galaxy that have low albedos and scatter isotropically. Recent detections of spectral emission features support the Galactic fountain model for the scattering material, and molecular hydrogen emission suggests that the emitting material tends to clump in hydrogen clouds.

Bowyer, Stuart↗

Investigation of the feasibility of optical diagnostic measurements at the exit of the SSME

Under Contract NAS8-36861 sponsored by NASA Marshall Space Flight Center, the United Technologies Research Center is conducting an investigation of the feasibility of remote optical diagnostics to measure temperature, species concentration and velocity at the exit of the Space Shuttle Main Engine (SSME). This is a two phase study consisting of a conceptual design phase followed by a laboratory experimental investigation. The first task of the conceptual design studies is to screen and evaluate the techniques which can be used for the measurements. The second task is to select the most promising technique or techniques, if as expected, more than one type of measurement must be used to measure all the flow variables of interest. The third task is to examine in detail analytically the capabilities and limitations of the selected technique(s). The results of this study are described in the section of this report entitled Conceptual Design Investigations. The conceptual design studies identified spontaneous Raman scattering and photodissociative flow-tagging for measurements respectively of gas temperature and major species concentration and for velocity. These techniques and others that were considered are described in the section describing the conceptual design. The objective of the second phase of investigations was to investigate experimentally the techniques identified in the first phase. The first task of the experimental feasibility study is to design and assemble laboratory scale experimental apparatus to evaluate the best approaches for SSME exit optical diagnostics for temperature, species concentrations and velocity, as selected in the Phase I conceptual design study. The second task is to evaluate performance, investigate limitations, and establish actual diagnostic capabilities, accuracies and precision for the selected optical systems. The third task is to evaluate design requirements and system trade-offs of conceptual instruments. Spontaneous Raman scattering excited by a KrF excimer laser pulse was investigated for SSME exit plane temperature and major species concentration measurements. The relative concentrations of molecular hydrogen and water vapor would be determined by measuring the integrated Q-branch scattering signals through narrow bandpass filters in front of photomultipliers. The temperature would be determined by comparing the signal from a single hydrogen rotational Raman line to the total hydrogen Q-branch signal. The rotational Raman line would be isolated by a monochromator and detected with a PMT.

Shirley, John A.↗

A Hazardous Gas Detection System for Aerospace and Commercial Applications

The detection of explosive conditions in aerospace propulsion applications is important for safety and economic reasons. Microfabricated hydrogen, oxygen, and hydrocarbon sensors as well as the accompanying hardware and software are being, developed for a range of aerospace safety applications. The development of these sensors is being done using MEMS (Micro ElectroMechanical Systems) based technology and SiC-based semiconductor technology. The hardware and software allows control and interrocation of each sensor head and reduces accompanying cabling through multiplexing. These systems are being, applied on the X-33 and on an upcoming STS-95 Shuttle mission. A number of commercial applications are also being pursued. It is concluded that this MEMS-based technology has significant potential to reduce costs and increase safety in a variety of aerospace applications.

Hunter, G. W.↗