Search NASA⌕ Search

SEARCH · Search NASA

Results for “imagers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Overview of the distributed image processing infrastructure to produce the Legacy Survey of Space and Time

The Vera C. Rubin Observatory is preparing to execute the most ambitious astronomical survey ever attempted, the Legacy Survey of Space and Time (LSST). Currently the final phase of construction is under way in the Chilean Andes, with the Observatory’s ten-year science mission scheduled to begin in 2025. Rubin’s 8.4-meter telescope will nightly scan the southern hemisphere collecting imagery in the wavelength range 320–1050 nm covering the entire observable sky every 4 nights using a 3.2 gigapixel camera, the largest imaging device ever built for astronomy. Automated detection and classification of celestial objects will be performed by sophisticated algorithms on high-resolution images to progressively produce an astronomical catalog eventually composed of 20 billion galaxies and 17 billion stars and their associated physical properties. In this article we present an overview of the system currently being constructed to perform data distribution as well as the annual campaigns which reprocess the entire image dataset collected since the beginning of the survey. These processing campaigns will utilize computing and storage resources provided by three Rubin data facilities (one in the US and two in Europe). Each year a Data Release will be produced and disseminated to science collaborations for use in studies comprising four main science pillars: probing dark matter and dark energy, taking inventory of solar system objects, exploring the transient optical sky and mapping the Milky Way. Also presented is the method by which we leverage some of the common tools and best practices used for management of large-scale distributed data processing projects in the high energy physics and astronomy communities. We also demonstrate how these tools and practices are utilized within the Rubin project in order to overcome the specific challenges faced by the Observatory.

79 ASTRONOMY AND ASTROPHYSICS↗

Wide-field turbulence imaging with beam emission spectroscopy

Imaging of the size, shape, time-averaged, and time-resolved dynamics of long-wavelength density turbulence structures is accomplished with an expanded, high-sensitivity, wide-field beam emission spectroscopy (BES) diagnostic on DIII-D. A 64-channel BES system is configured with an 8x8 grid of discrete channels that image an approximately 7x9 cm region at the outboard midplane. The grid covers multiple correlation lengths and each channel shape matches the measured radial-poloidal correlation length asymmetry of turbulent eddies. The wide field 8x8 imaging capability allows for sampling of essentially the full two-dimensional spatial correlation function for typical plasma conditions. The sampled area can be radially scanned over 0.4<r/a<1, including the core (n-tilde/n<1%), pedestal, and scrape-off-layer. The resulting time-resolved visualizations of turbulence and flows provide critical data on turbulence dynamics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flexible sample environment for high resolution neutron imaging at high temperatures in controlled atmosphere

In high material penetration by neutrons allows for experiments using sophisticated sample environments providing complex conditions. Thus, neutron imaging holds potential for performing in situ nondestructive measurements on large samples or even full technological systems, which are not possible with any other technique. Our paper presents a new sample environment for in situ high resolution neutron imaging experiments at temperatures from room temperature up to 1100 degrees C and/or using controllable flow of reactive atmospheres. The design also offers the possibility to directly combine imaging with diffraction measurements. Design, special features, and specification of the furnace are described. In addition, examples of experiments successfully performed at various neutron facilities with the furnace, as well as examples of possible applications are presented. Our work covers a broad field of research from fundamental to technological investigations of various types of materials and components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced magneto-optical microscopy: Imaging from picoseconds to centimeters - imaging spin waves and temperature distributions (invited)

Recent developments in the observation of magnetic domains and domain walls by wide-field optical microscopy based on the magneto-optical Kerr, Faraday, Voigt, and Gradient effect are reviewed. Emphasis is given to the existence of higher order magneto-optical effects for advanced magnetic imaging. Fundamental concepts and advances in methodology are discussed that allow for imaging of magnetic domains on various length and time scales. Time-resolved imaging of electric field induced domain wall rotation is shown. Visualization of magnetization dynamics down to picosecond temporal resolution for the imaging of spin-waves and magneto-optical multi-effect domain imaging techniques for obtaining vectorial information are demonstrated. Beyond conventional domain imaging, the use of a magneto-optical indicator technique for local temperature sensing is shown.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High dynamic range CdTe mixed-mode pixel array detector (MM-PAD) for kilohertz imaging of hard x-rays

A hard x-ray, high-speed, high dynamic range scientific x-ray imager is described. The imager is based on the mixed-mode pixel array detector (MM-PAD) readout chip coupled to a 750 µm thick cadmium telluride (CdTe) sensor. The full imager is a 2 × 3 tiled array of MM-PAD sensor/readout chip hybrids. CdTe improves detection for high energy x-rays as compared to silicon sensors, enabling efficient x-ray imaging to extend to >100 keV. The detector is capable of 1 kHz imaging and in-pixel circuitry has been designed to allow for well depths of greater than 4 × 10 6 80 keV x-rays. Here, a charge integrating front-end allows for quantitative measurement of high flux x-ray images beyond the capabilities of photon counting detectors. Detector performance is summarized and experimental measurements are presented.

99 GENERAL AND MISCELLANEOUS↗

Synthesis Structure and Imaging of Oligodeoxyribonucleotides with Tellurium-nucleobase Derivatization

We report here the first synthesis of 5-phenyl-telluride-thymidine derivatives and the Te-phosphoramidite. We also report here the synthesis, structure and STM current-imaging studies of DNA oligonucleotides containing the nucleobases (thymine) derivatized with 5-phenyl-telluride functionality (5-Te). Our results show that the 5-Te-DNA is stable, and that the Te-DNA duplex has the thermo-stability similar to the corresponding native duplex. The crystal structure indicates that the 5-Te-DNA duplex structure is virtually identical to the native one, and that the Te-modified T and native A interact similarly to the native T and A pair. Furthermore, while the corresponding native showed weak signals, the DNA duplex modified with electron-rich tellurium functionality showed strong topographic and current peaks by STM imaging, suggesting a potential strategy to directly image DNA without structural perturbation.

59 BASIC BIOLOGICAL SCIENCES↗

DeepLearnMOR: a deep-learning framework for fluorescence image-based classification of organelle morphology

Abstract The proper biogenesis, morphogenesis, and dynamics of subcellular organelles are essential to their metabolic functions. Conventional techniques for identifying, classifying, and quantifying abnormalities in organelle morphology are largely manual and time-consuming, and require specific expertise. Deep learning has the potential to revolutionize image-based screens by greatly improving their scope, speed, and efficiency. Here, we used transfer learning and a convolutional neural network (CNN) to analyze over 47,000 confocal microscopy images from Arabidopsis wild-type and mutant plants with abnormal division of one of three essential energy organelles: chloroplasts, mitochondria, or peroxisomes. We have built a deep-learning framework, DeepLearnMOR (Deep Learning of the Morphology of Organelles), which can rapidly classify image categories and identify abnormalities in organelle morphology with over 97% accuracy. Feature visualization analysis identified important features used by the CNN to predict morphological abnormalities, and visual clues helped to better understand the decision-making process, thereby validating the reliability and interpretability of the neural network. This framework establishes a foundation for future larger-scale research with broader scopes and greater data set diversity and heterogeneity.

Plant Sciences↗

Simultaneous X-ray diffraction and phase-contrast imaging for investigating material deformation mechanisms during high-rate loading

Using a high-speed camera and an intensified charge-coupled device (ICCD), a simultaneous X-ray imaging and diffraction technique has been developed for studying dynamic material behaviors during high-rate tensile loading. A Kolsky tension bar has been used to pull samples at 1000 s -1 and 5000 s -1 strain-rates for super-elastic equiatomic NiTi and 1100-O series aluminium, respectively. By altering the ICCD gating time, temporal resolutions of 100 ps and 3.37 µs have been achieved in capturing the diffraction patterns of interest, thus equating to single-pulse and 22-pulse X-ray exposure. Furthermore, the sample through-thickness deformation process has been simultaneously imaged via phase-contrast imaging. It is also shown that adequate signal-to-noise ratios are achieved for the detected white-beam diffraction patterns, thereby allowing sufficient information to perform quantitative data analysis diffraction via in-house software ( WBXRD_GUI ). Of current interest is the ability to evaluate crystal d -spacing, texture evolution and material phase transitions, all of which will be established from experiments performed at the aforementioned elevated strain-rates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A positron projection imager for whole-body mouse imaging

Certain experimental questions in molecular imaging can be answered with projection imaging systems rather than tomographs. Accordingly, we have designed, assembled and are now testing a projection imaging system able to visualize the whole-body distribution of positron-emitting compounds in mouse-size animals. When completed, this positron projection imager (PPI) will plug into the MONICA portable dual gamma camera system to provide the user with a positron projection imaging capability and all of the data acquisition and analysis features available with MONICA for single photon projection imaging.

Seidel, J.↗

A Monte Carlo investigation of low-Z target image quality generated in a linear accelerator using Varian's VirtuaLinac

Purpose: The focus of this work was the demonstration and validation of VirtuaLinac with clinical photon beams and to investigate the implementation of low-Z targets in a TrueBeam linear accelerator (Linac) using Monte Carlo modeling. Methods: VirtuaLinac, a cloud based web application utilizing Geant4 Monte Carlo code, was used to model the Linac treatment head components. Particles were propagated through the lower portion of the treatment head using BEAMnrc. Dose distributions and spectral distributions were calculated using DOSXYZnrc and BEAMdp, respectively. For validation, 6 MV flattened and flattening filter free (FFF) photon beams were generated and compared to measurement for square fields, 10 and 40 cm wide and at d{sub max} for diagonal profiles. Two low-Z targets were investigated: a 2.35 MeV carbon target and the proposed 2.50 MeV commercial imaging target for the TrueBeam platform. A 2.35 MeV carbon target was also simulated in a 2100EX Clinac using BEAMnrc. Contrast simulations were made by scoring the dose in the phosphor layer of an IDU20 aSi detector after propagating through a 4 or 20 cm thick phantom composed of water and ICRP bone. Results: Measured and modeled depth dose curves for 6 MV flattened and FFF beams agree within 1% for 98.3% of points at depths greater than 0.85 cm. Ninety three percent or greater of points analyzed for the diagonal profiles had a gamma value less than one for the criteria of 1.5 mm and 1.5%. The two low-Z target photon spectra produced in TrueBeam are harder than that from the carbon target in the Clinac. Percent dose at depth 10 cm is greater by 3.6% and 8.9%; the fraction of photons in the diagnostic energy range (25–150 keV) is lower by 10% and 28%; and contrasts are lower by factors of 1.1 and 1.4 (4 cm thick phantom) and 1.03 and 1.4 (20 cm thick phantom), for the TrueBeam 2.35 MV/carbon and commercial imaging beams, respectively. Conclusions: VirtuaLinac is a promising new tool for Monte Carlo modeling of novel target designs. A significant spectral difference is observed between the low-Z target beam on the Clinac platform and the proposed imaging beam line on TrueBeam, with the former providing greater diagnostic energy content.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-F-12A-06: BEST IN PHYSICS (IMAGING) - A Novel Catheter-Based Radionuclide Imaging System to Characterize Atherosclerotic Plaque

Purpose: Atherosclerosis underlies coronary artery diseases, the leading cause of death in the United States and worldwide. In this study, we developed a novel catheter-based radionuclide imaging (CRI) system to image 18F-fluorodeoxyglucose (18F-FDG), a radionuclide, a marker of vascular inflammation, in murine carotid arteries and characterized the system for spatial resolution from multiple scintillating materials. Methods: The catheter system includes 35 mm and 8 mm fixed focal length lenses, which are subsequently connected to a CMOS camera and fiber holder. The distal ferrule of an image bundle is terminated with a wide-angle lens. The novelty of this system is a scintillating balloon with a crystal tip in the front of the wide angle lens to image light from the decay of 18F-FDG emission signal. The scintillating balloon is fabricated from 1mL of silicone RTV catalyst mixed with 1 mL base and 50 mg/mL calcium fluoride doped with Europium (CaF2:Eu). To identify the optimal scintillating materials with respect to resolution, we calculated modulation transfer function (MTF) of Yttrium Aluminum Garnet doped with Cerium (YAG:Ce), anthracene, and CaF2:Eu phosphors using a thin line optical phantom (Fig. 1a-1b). Macrophage-rich FVB murine atherosclerotic carotid plaque model (n = 4) was used in ex vivo experiments. Confirmatory imaging was also performed by an external optical imaging system (IVIS-200). Results: Analysis of the different phosphors (Fig 1b) showed that CaF2:Eu enabled the best resolution of 1.2μm. The CRI system visualized 18F-FDG in atherosclerotic plaques (Fig. 1d). The ligated left carotid (LR) artery exhibited 4× higher 18F-FDG signal intensity compared to the non-ligated right carotid (negative control) artery (1.65×10{sup 2} ±4.07×10{sup 1} vs. 4.44×10{sup 1}±2.17×10{sup 0}, A.U., p = 0.005) and confirmed with IVIS-200 (Fig. 1d). Conclusion: This CRI system enables high-resolution and sensitive detection of 18F-FDG uptake by murine atherosclerotic plaques.

60 APPLIED LIFE SCIENCES↗

Technical Note: Relation between dual-energy subtraction of CT images for electron density calibration and virtual monochromatic imaging

Purpose: For accurate tissue inhomogeneity correction in radiotherapy treatment planning, the author previously proposed a simple conversion of the energy-subtracted computed tomography (CT) number to an electron density (ΔHU–ρ{sub e} conversion), which provides a single linear relationship between ΔHU and ρ{sub e} over a wide ρ{sub e} range. The purpose of the present study was to reveal the relation between the ΔHU image for ρ{sub e} calibration and a virtually monochromatic CT image by performing numerical analyses based on the basis material decomposition in dual-energy CT. Methods: The author determined the weighting factor, α{sub 0}, of the ΔHU–ρ{sub e} conversion through numerical analyses of the International Commission on Radiation Units and Measurements Report-46 human body tissues using their attenuation coefficients and given ρ{sub e} values. Another weighting factor, α(E), for synthesizing a virtual monochromatic CT image from high- and low-kV CT images, was also calculated in the energy range of 0.03 < E < 5 MeV, assuming that cortical bone and water were the basis materials. The mass attenuation coefficients for these materials were obtained using the XCOM photon cross sections database. The effective x-ray energies used to calculate the attenuation were chosen to imitate a dual-source CT scanner operated at 80–140 and 100–140 kV/Sn. Results: The determined α{sub 0} values were 0.455 for 80–140 kV/Sn and 0.743 for 100–140 kV/Sn. These values coincided almost perfectly with the respective maximal points of the calculated α(E) curves located at approximately 1 MeV, in which the photon-matter interaction in human body tissues is exclusively the incoherent (Compton) scattering. Conclusions: The ΔHU image could be regarded substantially as a CT image acquired with monoenergetic 1-MeV photons, which provides a linear relationship between CT numbers and electron densities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging Hydrated Microbial Extracellular Polymers: Comparative Analysis by Electron Microscopy

Microbe-mineral and -metal interactions represent a major intersection between the biosphere and geosphere but require high-resolution imaging and analytical tools for investigating microscale associations. Electron microscopy has been used extensively for geomicrobial investigations and although used bona fide, the traditional methods of sample preparation do not preserve the native morphology of microbiological components, especially extracellular polymers. Herein, we present a direct comparative analysis of microbial interactions using conventional electron microscopy approaches of imaging at room temperature and a suite of cryo-electron microscopy methods providing imaging in the close-to-natural hydrated state. In situ, we observed an irreversible transformation of bacterial extracellular polymers during the traditional dehydration-based sample preparation that resulted in the collapse of hydrated gel-like EPS into filamentous structures. Dehydration-induced polymer collapse can lead to inaccurate spatial relationships and hence could subsequently affect conclusions regarding nature of interactions between microbial extracellular polymers and their environment.

59 BASIC BIOLOGICAL SCIENCES↗

Aerosol Plume Detection Algorithm Based on Image Segmentation of Scanning Atmospheric Lidar Data

An image-processing algorithm has been developed to identify aerosol plumes in scanning lidar backscatter data. The images in this case consist of lidar data in a polar coordinate system. Each full lidar scan is taken as a fixed image in time, and sequences of such scans are considered functions of time. The data are analyzed in both the original backscatter polar coordinate system and a lagged coordinate system. The lagged coordinate system is a scatterplot of two datasets, such as subregions taken from the same lidar scan (spatial delay), or two sequential scans in time (time delay). The lagged coordinate system processing allows for finding and classifying clusters of data. The classification step is important in determining which clusters are valid aerosol plumes and which are from artifacts such as noise, hard targets, or background fields. These cluster classification techniques have skill since both local and global properties are used. Furthermore, more information is available since both the original data and the lag data are used. Performance statistics are presented for a limited set of data processed by the algorithm, where results from the algorithm were compared to subjective truth data identified by a human.

97 MATHEMATICS AND COMPUTING↗

Narrow-Band Imaging Improves Detection of Colorectal Peritoneal Metastases: A Clinical Study Comparing Advanced Imaging Techniques

Background: Colorectal peritoneal metastases (PM) are often diagnosed in an advanced disease stage. Cytoreduction and hyperthermic intraperitoneal chemotherapy (HIPEC) improve survival of patients with colorectal PM, although most benefit is seen in patients with limited peritoneal disease. Advanced imaging techniques might improve the detection of PM, potentially leading to earlier diagnosis and improved cytoreduction. This prospective clinical trial compared three advanced techniques with conventional white-light imaging for the detection of colorectal PM: narrow-band imaging (NBI), near-infrared indocyanine green fluorescent imaging (NIR-ICG), and spray-dye chromoendoscopy (SDCE). Methods: Patients with colorectal PM were prospectively included. Prior to cytoreduction and HIPEC, all abdominal regions were inspected with white-light imaging, NBI, NIR-ICG, and SDCE during exploratory laparoscopy. Primary endpoints were sensitivity and specificity for the detection of PM, using pathological examination of biopsied lesions as the reference standard. The safety of all techniques was assessed. Results: Between May 2016 and March 2018, four different techniques were analyzed in 28 patients, resulting in 169 biopsies. Sensitivity for the detection of PM significantly increased from 80.0% with white light to 96.0% with NBI (p = 0.008), without loss of specificity (74.8% vs. 73.1%, respectively, p = 0.804). The use of NIR-ICG and SDCE was discontinued after 10 patients had undergone treatment because the lesions were not fluorescent using NIR-ICG, and because SDCE did not visualize the whole peritoneum. No adverse events relating to the imaging techniques occurred. Conclusion: NBI substantially increased the detection of PM. This method is safe and could improve the detection of metastatic lesions and help optimize cytoreduction in patients with colorectal PM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Developing a high-speed terahertz imaging system based on parametric upconversion imaging for penetrative sensing

Imaging using THz waves has been a promising option for penetrative measurements in environments that are opaque to visible wavelengths. However, available THz imaging systems have been limited to relatively low frame rates and cannot be applied to study fast dynamics. This work explores the use of upconversion imaging techniques based on nonlinear optics to enable wavelength-flexible high frame rate THz imaging. UpConversion Imaging (UCI) uses nonlinear conversion techniques to shift the THz wavelengths carrying a target image to shorter visible or near-IR wavelengths that can be detected by available high-speed cameras. This report describes the analysis methodology used to design a prototype high-rate THz UCI system and gives a detailed explanations of the design choices that were made. The design uses a high-rate pulse-burst laser system to pump both THz generation and THz upconversion detection, allowing for scaling to acquisition rates in excess of 10 kHz. The design of the prototype system described in this report has been completed and all necessary materials have been procured. Assembly and characterization testing is on-going at the submission of this report. This report proposes future directions for work on high-rate THz UCI and potential applications of future systems.

47 OTHER INSTRUMENTATION↗

Individual Wave Detection and Tracking within a Rotating Detonation Engine through Computer Vision Object Detection applied to High-Speed Images

Known for their simplistic design and continuous detonation, rotating detonation engines (RDEs) constitute a majority of current pressure gain combustion (PGC) research efforts. Experimental RDE operation times have been continuously extended through the use of rig cooling techniques. As the window of observable behavior is expanded, and as the technology matures toward eventual integration within gas turbines, monitoring techniques must evolve to better match industrial diagnostics. High-speed image analysis techniques prove useful to capture and evaluate the unsteady detonation behavior within the RDE. Traditional image analysis techniques, however, require extensive processing times which prohibit simultaneous monitoring. To better address this problem, a computer vision object detection methodology is proposed to quickly detect individual detonation waves within a single down-axis image. Detonation waves are detected in individual images by the implemented computer vision method You Only Look Once (YOLO) object detection network. In order to detect detonation waves, the network must first be trained using RDE images of interest, for which each required phase of network development is outlined. Detection of waves is improved through proper treatment of the collected image set, variation of Intersection over Union (IoU) and confidence thresholding, and through a parametric study of annotation dimensions. Each detected wave is described by its location and rotational direction, and locations are tracked to calculate wave velocity across each frame, leading to a timestep resolution of 20 µs. Wave velocities are also calculated through a series of frames, leading to a suitable average velocity estimation using as few as 10 frames. Uncertainty analysis accounting for variation in camera framerate, pixel width and annotation centroid locations estimates a total uncertainty of ±4.3% for velocity calculations, using the smallest annotation boxes. This method offers great reductions in processing times, as a step toward real-time monitoring of detonation waves within an RDE. Improving on previous studies, this technique is impartial to wave modes not included in the original training set and calculates wave velocities independent of high-speed pressure data. The ability to isolate waves within predicted bounding boxes will likely facilitate analysis of pixel intensity variation as an estimation of wave strength in future work.

Johnson, Kristyn↗