Search NASA⌕ Search

SEARCH · Search NASA

Results for “imaging instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Global Auroral Imaging for the Dynamics Explorer Mission

The two Dynamics Explorer spacecraft, DE-1 and DE-2, were launched on August 3, 1981, into polar coplanar orbits at different altitudes for the purpose of studying interactive processes within the atmosphere-ionosphere-magnetosphere system. The DE-1 spacecraft (high-altitude mission) used an elliptical orbit that was selected to allow: (1) measurements extending from the hot magnetospheric plasma through the plasmasphere to the cool ionosphere; (2) global auroral imaging, wave measurements in the heart of the magnetosphere, and crossing of auroral field lines at several earth radii; and (3) measurements for significant periods of time along a magnetic field flux tube. The orbit of Dynamics Explorer 1 offered an opportunity to obtain global images of Earth's dayglow and auroral luminosities and to acquire consecutive images of the entire auroral oval during the growth, onset, expansion, and recovery phases of substorms. The University of Iowa's Spin-scan Auroral Imaging (SAI) instrument, was on-board DE-1. SAI was activated in orbit and placed in routine operation on September 23, 1981, and has provided outstanding new contributions in the fields of auroral, magnetospheric and geocoronal physics, introduced a powerful tool for the study of global atmospheric ozone, and initiated the first search from space for marine bioluminescence on the surface of the global ocean. The SAI instrumentation consists of three imaging photometers, two for visible wavelengths and the third for vacuum-ultraviolet wavelengths equipped with primary catoptric optics with superpolished mirror surfaces. The primary focusing element is an off-axis section of a parabolic mirror that is used to provide an optical path completely free of support structures for the mirrors.

Frank, L. A.↗

Maturing Electron Multiplying Charge Coupled Device Photon-Counting with Variable Multiplication Gain Imaging for a Coronagraphic Instrument

This is an introduction to a US Government Program that conducted high-contrast imaging experiments with an Electron Multiplying Charge Coupled Device (EMCCD) in an interferometric coronagraph. This report will introduce the concepts of “Charge Blooming” and “Starlight Saturation” in the context of high-contrast astronomical imaging. These phenomena adversely affect the performance of high-contrast photon-counting instruments that do not use a mask to physically block starlight in the science channel of the coronagraph. The problems will be presented with the help of images taken with a commercial EMCCD camera in the Visible Nulling Coronagraph at the Goddard Space Flight Center (GSFC). A new clocking scheme for EMCCDs – Variable Multiplication Gain Clocking – will be proposed as a means for suppressing horizontal blooming and starlight saturation in an astronomical camera. This opening report from the program will conclude with an introduction to a new controller for high-contrast imaging with EMCCDs in coronagraphs. This controller is being designed to allow a single frame from an EMCCD to be scanned in multiple modes – photon counting and digitization – to enable direct imaging of an exo-planet and wavefront control of a coronagraph, simultaneously.

Udayan Mallik↗

Spectrum – An Instrument for Multispectral Biological Fluorescence Imaging on the International Space Station

Spectrum is a compact instrument for fluorescent imaging of biological specimens in microgravity and capable of operating within the constraints of an EXPRESS Rack on the International Space Station (ISS). The Spectrum Flight Unit (SFU) was launched to ISSin November 2019 and is available for science investigations as a general instrument. A duplicate Engineering Development Unit (EDU) is available at NASA Kennedy Space Center (KSC). Science Verification Testing (SVT) performed at KSCdemonstrated all required functions including five (5) fluorescence excitation wavelengths, growth lighting, environmental controls and monitoring, and high-resolution imaging using a 71 Megapixel camera with flat field lens. The design features key Orbital Replaceable Unit (ORU) components, which may be adapted or changed by future investigators for tailored science experiments.

Bradley Burns↗

Single detector laser-induced fluorescence imager and raman spectral instrument

Apparatus include divergence optics removably coupled to receive a probe beam in a first imaging mode to cause the probe beam to diverge before impinging on a first area of a target surface, and to not receive the probe beam in a second imaging mode to cause the probe beam to impinge on a second area of the target surface smaller than the first area, collection optics configured to receive, in response to the probe beam, luminescence light emitted from the first area and spectral light emitted from the second area, and an optical detector coupled to the collection optics, wherein the optical detector includes a luminescence imaging detector portion and a spectral imaging detector portion adjacent to the luminescence imaging detector portion, wherein the luminescence imaging detector portion is configured to receive the luminescence light emitted from the first area and the spectral imaging detector portion is configured to receive the spectral light from the second area.

Gasda, Patrick J.↗

Wide Field Collimator 2 (WFC2) for GOES Imager and Sounder

Two of the GOES instruments, the Imager and the Sounder, perform scans of the Earth to provide a full disc picture of the Earth. To verify the entire scan process, an image of a target that covers an 18 deg. circular field-of-view is collimated and projected into the field of regard of each instrument. The Wide Field Collimator 2 (WFC2) has many advantages over its predecessor, WFC1, including lower thermal dissipation higher fir field MTF, smaller package, and a more intuitive (faster) focusing process. The illumination source is an LED array that emits in a narrow spectral band centered at 689 nm, within the visible spectral bands of the Imager and Sounder. The illumination level can be continuously adjusted electronically. Lower thermal dissipation eliminates the need for forced convection cooling and minimizes time to reach thermal stability. The lens system has been optimized for the illumination source spectral output and athernalized to remain in focus during bulk temperature changes within the laboratory environment. The MTF of the lens is higher than that of the WFC1 at the edge of FOV. The target is focused in three orthogonal motions, controlled by an ergonomic system that saves substantial time and produces a sharper focus. Key words: Collimator, GOES, Imager, Sounder, Projector

Etemad, Shahriar↗

X-ray sensitive oblique imaging device

Instrument employs light reflecting surface (evaporated aluminum coating or minor substrate) behind phosphor screen to improve effective quantum efficiency in dual process: fraction of incoming X-rays are converted to photoelectrons at photocathode; and X-rays that pass through photocathode and thin X-ray transparent membrane enter phosphor screen.

Hallam, K. L.↗

Rotation of the sun measured from Mount Wilson white-light images

The instrumentation, data and data reduction procedures used in white light observations of sunspot rotation rates are described. The study covered 62 yr of rotation observations. The data were all gathered using the same Mt. Wilson telescope, which has had three different main lenses in the interval 1981-82. Details of the exposure calibration and lens operation procedures are provided. The data were treated in terms of eight evenly space determinations of the solar limb and account was taken of all sunspots within 60 deg of the central meridian. Spot movements were traced in terms of groups of contiguous individual spots. Large spots rotated slower than small spots, a condition attributed to greater viscous drag in the larger flux tubes in the photosphere. The data tend to confirm theories that the photospheric gas revolves at a different rate than the sunspots.

Howard, R.↗

Preliminary Analysis Of Data From AVIRIS

Report presents preliminary analysis of performance of Airborne Visible/Infrared Imaging Spectrometer (AVIRIS), a scanning instrument producing images at wavelengths from 400 to 2,450 nm. Includes four spectrometers connected by optical fibers to common set of foreoptics. Focuses upon calibration of instrument and determination of reflectance of surface of Earth from its measurements.

Conel, James E.↗

Wide Field Infra-Red Survey Telescope (WFIRST) 2.4-Meter Mission Study

The most recent study of the Wide Field Infrared Survey Telescope (WFIRST) mission is based on reuse of an existing 2.4m telescope. This study was commissioned by NASA to examine the potential science return and cost effectiveness of WFIRST by using this significantly larger aperture telescope. We review the science program envisioned by the WFIRST 2012-2013 Science Definition Team (SDT), an overview of the mission concept, and the telescope design and status. Comparisons against the previous 1.3m and reduced cost 1.1m WFIRST design concepts are discussed. A significant departure from past point designs is the option for serviceability and the geostationary orbit location which enables servicing and replacement instrument insertion later during mission life. Other papers at this conference provide more in depth discussion of the wide field instrument and the optional exoplanet imaging coronagraph instrument.

exoplanet imaging coronagraph↗

FIRST HIGH-RESOLUTION IMAGES OF THE SUN IN THE 2796 Å Mg II k LINE

We present the first high-resolution solar images in the Mg II k 2796 Å line. The images, taken through a 4.8 Å broad interference filter, were obtained during the second science flight of Sunrise in 2013 June by the Sunrise Filter Imager (SuFI) instrument. The Mg II k images display structures that look qualitatively very similar to images taken in the core of Ca II H. The Mg II images exhibit reversed granulation (or shock waves) in the internetwork regions of the quiet Sun, at intensity contrasts that are similar to those found in Ca II H. Very prominent in Mg II are bright points, both in the quiet Sun and in plage regions, particularly near the disk center. These are much brighter than at other wavelengths sampled at similar resolution. Furthermore, Mg II k images also show fibril structures associated with plage regions. Again, the fibrils are similar to those seen in Ca II H images, but tend to be more pronounced, particularly in weak plage.

79 ASTRONOMY AND ASTROPHYSICS↗

Photographic stellar photometry with the PDS microdensitometer

A technique for photographic stellar photometry with the PDS microdensitometer is described. It employs a least-squares fit to a model density profile to derive an instrumental magnitude index, an image-abnormality index, and the local value of the background density for each image. The instrumental magnitude index is calibrated in terms of true magnitude by the same methods as for iris photometry. A preliminary test of the method using plates of the open cluster NGC 188 indicates that a precision comparable to or slightly better than that of conventional iris photometry or other methods of PDS reduction may easily be attained. Possibilities for the future elaboration of the technique are mentioned.

Stetson, P. B.↗

Auroral, Polar Cap, and Polar Cusp Modeling and Data Analysis for the IMAGE Mission and LENA Instrument

One of the chief mysteries in the LENA perigee pass data is the lack of an apparent auroral oval in the images. Another is that in some cases ENA are seen from any direction near the Earth regardless of the latitude of the spacecraft. These facts lead one to ask a fundamental question: Is the instrument responding to ENA primarily? One possible way to get out of the "ambiguity" of the data is to assume that at least part of the signal is produced by something other than ENA. The two main candidates for this "something else" are UV light and energetic charged particles. UV light could only effect the instrument when its fan shaped aperture points toward the source. The most intense of which will be the sun, with day glow being the second strongest and the auroral zone, the third. We can rule out UV light as a prime source of counts in the perigee pass data for the following reasons: 1) The perigee pass signal is different in form and much stronger than the sun pulse signal seen just before or just after perigee; 2) There is no indication of the auroral zone, which would produce at least two peaks in the counts versus spin phase curve; 3) Mike Colliers' analysis of the sun pulse signal shows that it varies with the flux of the solar wind and not with variations in the solar UV flux. Charge particles that enter the aperture of the instrument and produce counts would show up when the instrument looks in the direction from which they come. In all of the data I am analyzing voltages were being applied to the collimators so that most charged particles should have been excluded from the instrument but this effect could still show up where the flux of energetic particles is high enough. The most likely place would be in the auroral zone where energetic electrons and protons precipitate. If these particles are producing counts then they should be seen when the instrument looks in and near the zenith direction. In nearly all of the perigee passes the zenith direction is devoid of counts.

Wilson, Gordon R.↗

Development Of Infrared Imager For Spacelab

Terrestrial instrument modified for use in outer space. Report discusses progress in development of infrared-imaging instrument for use in microgravity scientific experiments in manned module in payload bay of Space Shuttle. Imager intended primarily for characterization of surface temperatures in microgravity fluid-physics experiment. Design versatile so instrument serves as "off-the-shelf" unit for other experiments, eliminating need to duplicate development and qualifications for spacecraft for future experiments.

Pline, Alexander D.↗

Enabling the Acquisition of Electron Beam-Induced Current (EBIC) Images in Conventional SEM and STEM Instruments

Electron beam-induced current (EBIC) imaging is a well-established scanning electron microscope (SEM) technique used to analyze the behavior of microelectronic devices including solar cells. Recently, the application of EBIC imaging in an aberration-corrected scanning transmission electron microscope (STEM) has been demonstrated and offers great potential for the in situ study of electronic materials, correlating charge transport properties to atomic structural and elemental information. Here, this work presents two ways to implement EBIC imaging in conventional SEM and STEM systems: one relying on the instrument's inherent scanning and imaging electronics and the other involving third-party systems usually available in electron microscopes. The implementation of lock-in EBIC in systems equipped with a fast beam blanker is also described. In addition, this work shows and discusses the different mechanisms at play in EBIC imaging and their dependence on beam energy, sample impedance, and electrical measurement configuration, providing researchers with the basic information needed to apply the technique to their research.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Calibration and Characterization of the NASA EOS Terra and Aqua MODIS Instruments

The Moderate Resolution Imaging Spectroradiometer (MODIS) instrument is operating on both of the Terra and Aqua missions within the NASA Earth Observing System (EOS). The Terra MODIS instrument began taking observations in February 2000 and the Aqua MODIS instrument began taking observations in June of 2002 and both continue to operate successfully up to the present time. The MODIS instrument scans the entire Earth every 24 hours at nominal spatial resolutions between 250 and 1000 meters. It has 36 spectral bands spanning the electromagnetic spectrum from the visible wavelengths mar 400 micrometers to the emissive thermal infrared wavelengths at 15 micrometers. The MODIS instruments produce approximately 40 geophysical products devoted to observing land, ocean, and atmospheric processes and trends. To meet the scientific objectives associated with the NASA Earth sciences efforts the MODIS instruments must be and have been carefully calibrated and the performance characterized to meet specifications and goals such as five percent radiance and two percent relative to the sun accuracy in the twenty bands providing reflected solar radiation observations and one percent radiance accuracy in the sixteen bands observing in the thermal infrared. Over the time spanning instrument development and the pre-launch calibration and characterization of the instrument through the years of operation in space, the performance of the MODIS instruments have changed in multiple ways and appropriate adjustments made in relevant algorithms and look-up tables necessary to produce observations that meet the scientific objectives and requirements. The changes have been quantified and accounted for through careful use of on-board calibration devices such as the Spectro-Radiometric Calibration Assembly (SRCA), the Solar Diffuser (SD) and its companion Solar Diffuser Stability Monitor (SDSM), deep-space and lunar observations, and calibration targets on the Earth's surface. The strictest and most difficult challenges have come in trying to meet the requirements for observing Ocean color and related ocean biology processes over time and space. Overall the MODIS observations have been very successful in providing valuable scientific and applications results. The essential capabilities of MODIS are to be provided in the future by the Visible and Infrared Imaging Radiometer Suite (VIIRS) on the National Polar Orbiting Environmental Satellite Series (NPOESS).

Salomonson, Vincent V.↗

Execution phase (C/D) spectral band characteristics of the EOS moderate resolution imaging spectrometer-Nadir (Modis-N) facility instrument

The Moderate Resolution Imaging Spectrometer (Modis) observing facility on the Earth Observing System (EOS) is composed of two instruments: Modis-Nadir (N) and Modis-Tilt (T). Modis-N has 36 spectral bands between 0.4 and 14.2 microns, with spatial resolution between 250 and 1000 meters. Modis-T has 32 bands with 10-15 nm bandwidths between 0.4 and 0.9 microns. Modis-T scans fore and aft +/- 50 degrees. Both instruments scan cross-track so as to provide daily (Modis-N) or once every two days (Modis-T) coverage at 705-km altitude. Both instruments are entering into the execution phases of their development in 1990. The bands of the Modis-N hve been chosen so as to provide key observations of land, ocean, and atmosphere parameters that will provide key data sets assisting in gaining an improved understanding of global processes.

Salomonson, Vincent V.↗

An instrument for 3D x-ray nano-imaging

We present an instrument dedicated to 3D scanning x-ray microscopy, allowing a sample to be precisely scanned through a beam while the angle of x-ray incidence can be changed. The position of the sample is controlled with respect to the beam-defining optics by laser interferometry. The instrument achieves a position stability better than 10 nm standard deviation. The instrument performance is assessed using scanning x-ray diffraction microscopy and we demonstrate a resolution of 18 nm in 2D imaging of a lithographic test pattern while the beam was defined by a pinhole of 3 {mu}m in diameter. In 3D on a test object of copper interconnects of a microprocessor, a resolution of 53 nm is achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Sequential Filter Imaging Radiometer (SFIR), a new instrument configuration for Earth observations

The sequential filter imaging radiometer (SFIR) concept is presented, contrasted with other sensor configurations, and its strengths and weaknesses discussed. In a pushbroom SFIR the optics images the scene onto a long, narrow area array. The length of the array defines the field of view. The spectral defining filters are sequentially placed over the full array, a sample of data for that band taken, and then the next filter placed in front of the array. All of the filters are placed over the array in the time that it takes the image of the scene to advance the array width. Thus the entire scene is observed in each band. Advantages of the SFIR are: spectral bands can be broad, narrow or overlap; it is easy to improve signal to noise ratio; and it is simple to make bands polarized. Its main disadvantage is that it requires more detectors than other instrument configurations.

Maxwell, M. S.↗