Search NASA⌕ Search

SEARCH · Search NASA

Results for “interconnected systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Evaluation of Grounding Impedance of a Complex Lightning Protective System Using Earth Ground Clamp Measurements and ATP Modeling

A new Lightning Protection System (LPS) was designed and built at Launch Complex 39B (LC39B), at the Kennedy Space Center (KSC), Florida, which consists of a catenary wire system (at a height of about 181 meters above ground level) supported by three insulators installed atop three towers in a triangular configuration. A total of nine downconductors (each about 250 meters long, on average) are connected to the catenary wire system. Each of the nine downconductors is connected to a 7.62-meter radius circular counterpoise conductor with six equally spaced 6-meter long vertical grounding rods. Grounding requirements at LC39B call for all underground and above ground metallic piping, enclosures, raceways, and cable trays, within 7.62 meters of the counterpoise, to be bounded to the counterpoise, which results in a complex interconnected grounding system, given the many metallic piping, raceways, and cable trays that run in multiple direction around LC39B. The complexity of this grounding system makes the fall of potential method, which uses multiple metallic rods or stakes, unsuitable for measuring the grounding impedances of the downconductors. To calculate the downconductors grounding impedance, an Earth Ground Clamp (a stakeless grounding resistance measuring device) and a LPS Alternative Transient Program (ATP) model are used. The Earth Ground Clamp is used to measure the loop impedance plus the grounding impedance of each downconductor and the ATP model is used to calculate the loop impedance of each downconductor circuit. The grounding impedance of the downconductors is then calculated by subtracting the ATP calculated loop impedances from the Earth Ground Clamp measurements.

Mata, Carlos T.↗

A Digital Twin for an Inverter-Based Resource Power Plant: Real-time data streaming unlocks situation awareness

Here, this study presents the development and successful implementation of a digital twin specifically designed for a grid-connected IBR power plant. By integrating a reduced-order model of the IBR system and dynamically updating the grid impedance with real-time data, the digital twin effectively captures and replicates the behavior of the physical system. Its accuracy and reliability are validated through critical test scenarios, including a three-phase fault and a line-tripping event. The results confirm that the digital twin closely emulates its physical counterpart, demonstrating its strong potential for real-time analysis, system monitoring, and predictive decision making in modern power systems.

Digital twins↗

Voyager 1 encounter with the Jovian system

An overview of the Voyager 1 encounter with Jupiter is presented. Voyager conducted close range measurements of the atmosphere, satellites and magnetosphere of Jupiter from January 6, 1979 to April 13, 1979, coming as close as 348,890 km to the planet. The three-axis stabilized spacecraft carries radioisotope thermoelectric generators providing 445 W of power to the instruments and transmitters and makes use of an X-band telemetry rate of up to 115.2 kbit/sec, a scan platform providing pointing control of 0.15 deg/axis for the instruments carried on it, and three interconnected computer systems. The trajectory of Voyager through the Galilean satellites is illustrated, noting that the trajectory allows for periods of sun and earth occultation, south polar passage by Io, close encounters with Ganymede and Callisto and earth-Jupiter communications distances supporting 21 to 22 h of maximum data rates daily. Highlights of the results of the investigations are presented.

Stone, E. C.↗

Simulation of Inrush Dynamics for Unbalanced Distribution Systems using Phasor Dynamics

Microgrids are a possible solution to mitigate the extensive interruptions in service to end-use customers caused by abnormal events, such as major natural disasters. Microgrids can be formed by energizing portions of the distribution system to interconnect generator and critical loads. In this scenario, inrush dynamic currents can present a barrier for forming microgrids by preventing the necessary switching operations and/or damaging equipment. Modeling inrush dynamics, through electromagnetic transient tools, presents a challenge when the microgrid represents a large portion of a distribution feeder. This paper uses a phasor dynamics approach to approximate the envelope of inrush dynamics, thus allowing simulations of large systems. The two main contributions of this paper are: a) a new formulation to solve a set of phasor-dynamic differential equations representing an unbalanced distribution system; and b) modeling of transformer saturation in the phasor-dynamics frame. These two contributions allow the in-rush phenomena to be simulated on full size microgrid and/or distribution feeder models. The new formulation and model are implemented in GridLAB-D, and tested on IEEE test systems.

inrush, GridLAB-D, distribution analysis, microgri↗

Blockchain Enabled Intelligence of Federated Systems (BELIEFS): An attack-tolerant trustable distributed intelligence paradigm

In this article, a Blockchain Enabled Intelligence of Federated Systems (BELIEFS) is proposed to conduct cooperative control for the multi-regional large-scale power system with a multi-agents system (MAS). By establishing a two levels blockchain, each regional AI agent can simultaneously manage intra-regional controllers and cooperate with other AI agents. Under the consensus mechanism, the agents, which respectively conducted distributed deep reinforcement learning (DDRL) algorithm in multi-regions, can have the tolerant capability of malicious attacks in their training process. The demonstration of the proposed approach is within a multi-regional large-scale interconnected power system. Under the mode of "centralized dispatching and hierarchical management", this article aims to definite a mathematical model to deal with the control problem of the power systems. With the comparison experiments, the effectiveness and efficiency of our proposed method in the training process are verified. In addition, malicious attacks are set on the main chain and shard chains to verify the attack-tolerant capability. We expect that such approach and results can suggest a new paradigm of attack-tolerant trustable distributed AI deployment.

97 MATHEMATICS AND COMPUTING↗

Enhancing Cloud Cybersecurity: Prescriptive Controls for Operational Technology

This whitepaper provides strategic insights and recommendations into security cloud-based solutions for electric utilities, encompassing operational technology (OT), virtual power plants (VPP), distributed energy resources (DERs), applications, networks, and data storage as they transition to and leverage cloud infrastructure through managed service providers (MSPs) and cloud service providers (CSPs). Principles derived from established frameworks serve as a foundation for best practices across cybersecurity projects and remove the constraints of settling on a single framework. For organizations that prefer not to integrate a specific framework altogether, elements of the proposed approach could be adopted or tailored to best fit defined requirements and expected functionalities. The Cirrus assessment, a utility cloud feasibility tool, and the roadmap it provides serve as a precursor to this paper, which seeks to be a valuable resource for defining next steps following cloud technology integration feasibility appraisal. With its comprehensive approach to adoption, the Cirrus framework offers strategic guidance on responsibly preparing for or deploying a utility cloud solution. The previously published whitepaper, “Use Case-Informed Framework for Utility Cloud Migration,” details the guiding strategy, research, and deployment of cloud solutions within electric and interconnected grid systems. Before implementing the controls suggested in this document, it is recommended that stakeholders complete Cirrus's cloud integration assessment and pair the results with their unique cybersecurity controls to form a comprehensive cloud-based utility cybersecurity plan. The Cirrus outcome will consider a series of future architectures for the grid before and after the energy transition and evaluate the arguments for and against cloud applications for each electric and interconnected grid layer. This document is a companion to the original whitepaper, "Use Case-Informed Framework for Utility Cloud Migration" to further identify and recommend security controls based on Cirrus’s cloud integration assessment output. The following whitepaper outlines the cybersecurity controls that secure cloud-service models pertinent to the electric sector using the predefined categories identify, protect, detect, and respond and recover. The objective is to outline prescriptive security controls based on the type of architecture and data stored in the cloud. The focus includes dissecting the shared responsibility model and elucidating what on-premises Infrastructure as a Service (IaaS), Platform as a Service (PaaS), and Software as a Service (SaaS) entail. A pivotal consideration in this context is allocating responsibility for foundational cybersecurity aspects—having used Cirrus for the cloud integration assessment. The ensuing controls detailed herein also represent a checklist of controls necessary for a secure cloud transition, equipping utilities with the knowledge to navigate this digital transformation with confidence and strategic foresight in a safe and responsible manner.

42 ENGINEERING↗

Modeling Power System Operation with Intermittent Resources

Electricity generating companies and power system operators face the need to minimize total fuel cost or maximize total profit over a given time period. These issues become optimization problems subject to a large number of constraints that must be satisfied simultaneously. The grid updates due to smart-grid technologies plus the penetration of intermittent re- sources in electrical grid introduce additional complexity to the optimization problem. The Renewable Integration Model (RIM) is a computer model of interconnected power system. It is intended to provide insight and advice on complex power systems management, as well as answers to integration of renewable energy questions. This paper describes RIM basic design concept, solution method, and the initial suite of modules that it supports.

Marinovici, Maria C.↗

Implementations and Evaluations of Wind Turbine Inertial Controls With FAST and Digital Real-Time Simulations

This paper presents a novel simulation approach to evaluate new ancillary service controls in the context of large-scale wind power integration. We adopt and compare different types of turbine inertial control methods with the proposed modifications to cope with realistic wind conditions in the field. The simulation procedure is started with the software-based simulation, in which we employ the high-fidelity wind turbine simulator FAST that models a real three-bladed controls advanced research turbine (CART3). The advantages of using FAST are that it can provide convincing simulation results and address the interactions between turbine electrical and mechanical systems. The developed controller model is then rapidly prototyped for the real-time simulation with the hardware-in-the-loop scheme. CART3 will respond to a virtual frequency event triggered in the emulated electric grid modeled in a digital real-time simulator. The introduced simulation platform streamlines the procedure of designing turbine auxiliary controls, and these simulations results give insights on the turbine controls and their impacts on the interconnected power system, as well as the effects on turbine mechanical components. For example, the results indicate that the inertial controls tend to reduce the out-of-plane mechanical loadings in region 2, while such loadings are dominated by the pitch actions in region 3.

17 WIND ENERGY↗

High performance interconnection between high data rate networks

The bridge/gateway system needed to interconnect a wide range of computer networks to support a wide range of user quality-of-service requirements is discussed. The bridge/gateway must handle a wide range of message types including synchronous and asynchronous traffic, large, bursty messages, short, self-contained messages, time critical messages, etc. It is shown that messages can be classified into three basic classes, synchronous and large and small asynchronous messages. The first two require call setup so that packet identification, buffer handling, etc. can be supported in the bridge/gateway. Identification enables resequences in packet size. The third class is for messages which do not require call setup. Resequencing hardware based to handle two types of resequencing problems is presented. The first is for a virtual parallel circuit which can scramble channel bytes. The second system is effective in handling both synchronous and asynchronous traffic between networks with highly differing packet sizes and data rates. The two other major needs for the bridge/gateway are congestion and error control. A dynamic, lossless congestion control scheme which can easily support effective error correction is presented. Results indicate that the congestion control scheme provides close to optimal capacity under congested conditions. Under conditions where error may develop due to intervening networks which are not lossless, intermediate error recovery and correction takes 1/3 less time than equivalent end-to-end error correction under similar conditions.

Foudriat, E. C.↗

NASA ground communications

As part of the Communications Requirements and Constraints, NASA's two major Ground Data Networks were briefly described. The NASA Communication Network, called NASCOM, is the worldwide operational telecommunications system which interconnects as the tracking and telemetry acquisition sites, launch areas, mission and project control centers, data capture facilities, and network control centers in support of space flight. For the Space Station era, NASCOM plans are set for higher data rate service utilizing data packet switched technology. Increased use of fiber optics is expected in a much more diverse network topology. The second major ground network, the Program Support Communications Network (PSCN), interconnects all NASA Centers and NASA contractor locations for intercenter non-operation communications. The primary functions are to transport voice, video, data and facsimile information for intercenter coordination, and to provide user access to space science and applications data bases. For the Space Station era, PSCN plans address the significant increase in forecast requirements for science data distribution and access to the Numerical Aerodynamics Simulator, and increased use of the Video Teleconference System.

Roeder, John↗

Time variant analysis of large scale constrained rotorcraft systems dynamics - An exploitation of IBM-3090 vector-processor's pipe-lining feature

A generalized algorithmic procedure is presented for handling the constraints in transmissions, which are treated as a multibody system of interconnected rigid/flexible bodies. The type of constraints are classified based on the interconnection of the bodies, assuming one or more points of contact to exist between them. The method is explained through flow charts and configuration/interaction tables. A significant increase in speed of execution is achieved by vectorizing the developed code in computationally intensive areas. The study of an example consisting of two meshing disks rotating at high angular velocity is carried out. The dynamic behavior of the constraint forces associated with the generalized coordinates of the system are plotted by selecting various modes. Applications are intended for the study of dynamic and subsequent prediction of constraint forces at the gear teeth contacting points in helicopter transmissions with the aim of improving performance dependability.

Amirouche, F. M. L.↗

Institute for Sustained Performance, Energy, and Resilience (SuPER)

The University of Tennessee (UTK) and University of Texas at El Paso (UTEP) partnership supported the three main thrusts of the SUPER project---performance, energy, and resilience. The UTK-UTEP effort thus helped advance the main goal of SUPER, which was to ensure that DOE's computational scientists can successfully exploit the emerging generation of high performance computing (HPC) systems. This goal is being met by providing application scientists with strategies and tools to productively maximize performance, conserve energy, and attain resilience. The primary vehicle through which UTK provided performance measurement support to SUPER and the larger HPC community is the Performance Application Programming Interface (PAPI). PAPI is an ongoing project that provides a consistent interface and methodology for collecting hardware performance information from various hardware and software components, including most major CPUs, GPUs and accelerators, interconnects, I/O systems, and power interfaces, as well as virtual cloud environments. The PAPI software is widely used for performance modeling of scientific and engineering applications---for example, the HOMME (High Order Methods Modeling Environment) climate code, and the GAMESS and NWChem computational chemistry codes---on DOE supercomputers. PAPI is widely deployed as middleware for use by higher-level profiling, tracing, and sampling tools (e.g., CrayPat, HPCToolkit, Scalasca, Score-P, TAU, Vampir, PerfExpert), making it the de facto standard for hardware counter analysis. PAPI has established itself as fundamental software infrastructure in every application domain (spanning academia, government, and industry), where improving performance can be mission critical. Ultimately, as more application scientists migrate their applications to HPC platforms, they will benefit from the extended capabilities this grant brought to PAPI to analyze and optimize performance in these environments, whether they use PAPI directly, or via third-party performance tools. Capabilities added to PAPI through this grant include support for new architectures such as the lastest GPU and Xeon Phi accelerators, and advanced power measurement and management features. Another important topic for the UTK team was providing support for a rich ecosystem of different fault management strategies in the context of parallel computing. Our long term efforts have been oriented toward proposing flexible strategies and providing building boxes that application developers can use to build the most efficient fault management technique for their application. These efforts span across the entire software spectrum, from theoretical models of existing strategies to easily assess their performance, to algorithmic modifications to take advantage of specific mathematical properties for data redundancy and to extensions to widely used programming paradigms to empower the application developers to deal with all types of faults. We have also continued our tight collaborations with users to help them adopt these technologies to ensure their application always deliver meaningful scientific data. Large supercomputer systems are becoming more and more power and energy constrained, and future systems and applications running on them will need to be optimized to run under power caps and/or minimize energy consumption. The UTEP team contributed to the SUPER energy thrust by developing power modeling methodologies and investigating power management strategies. Scalability modeling results showed that some applications can scale better with respect to an increasing power budget than with respect to only the number of processors. Power management, in particular shifting power to processors on the critical path of an application execution, can reduce perturbation due to system noise and other sources of runtime variability, which are growing problems on large-scale power-constrained computer systems.

42 ENGINEERING↗

A Study of the Impact of Peak Demand on Increasing Vulnerability of Cascading Failures to Extreme Contingency Events

The vulnerability of large power systems to cascading failures and major blackouts has become evident since the Northeast blackout in 1965. Based on analyses of the series of cascading blackouts in the past decade, the research community realized the urgent need to develop better methods, tools, and practices for performing cascading-outage analysis and for evaluating mitigations that are easily accessible by utility planning engineers. PNNL has developed the Dynamic Contingency Analysis Tool (DCAT) as an open-platform and publicly available methodology to help develop applications that aim to improve the capabilities of power planning engineers to assess the impact and likelihood of extreme contingencies and potential cascading events across their systems and interconnections. DCAT analysis will help identify potential vulnerabilities and allow study of mitigation solutions to reduce the risk of cascading outages in technically sound and effective ways. Using the DCAT capability, we examined the impacts of various load conditions to identify situations in which the power grid may encounter cascading outages that could lead to potential blackouts. This paper describes the usefulness of the DCAT tool and how it helps to understand potential impacts of load demand on cascading failures on the power system.

indexes↗

Cost-optimal evaluation of centralized and distributed microgrid topologies considering voltage constraints

Optimal design of hybrid renewable mini-grids requires both economic and power quality considerations. Existing modeling approaches address these considerations via separate or loosely coupled models. Here, we extend REopt—a techno-economic optimization model developed at the National Renewable Energy Laboratory—to consider both within a single model. REopt formulates the design problem as a mixed-integer linear program that solves for a site's optimal technology mix, sizing, and operation to minimize life cycle cost. REopt has traditionally assumed a single node system. In the work presented here, we expand the REopt platform to consider multiple connected nodes with associated voltage constraints. In order to do this, we model power flow using a fixed-point linear approximation method. Additionally, we then use the model to explore design considerations of mini-grids in Sub-Saharan Africa. Specifically, we evaluate under what combinations of transmission line distance and capacity it is technically viable and economically preferable to build multiple isolated mini-grids versus an interconnected, centralized system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Roadmap for the Future of Systems Biology in Cancer Research

Cancer systems biology seeks to understand how cancer arises as a system of interconnected molecules, cells, and tissues, with the goal of understanding, predicting, and controlling the disease. In the last decade, the field has rapidly grown as advances in experimental, computational, and analytic technologies have improved our ability to capture and recapitulate the complexities of cancer at multiple scales. However, the field’s promise to understand how specific molecular changes give rise to altered cancer outcomes remains incompletely fulfilled. Fortunately, an opportunity exists to accelerate progress by better coordinating modeling and data-gathering efforts across the cancer systems biology community. This will create the foundation for building accurate, multiscale cancer models that can better predict and identify improved therapeutic interventions. Here, in this study, we outline some of the current challenges in cancer systems biology research, how they can be addressed, and actions that the community can take to accelerate progress in the field.

Modeling & Simulation↗

A Module Experimental Process System Development Unit (MEPSDU)

Design work for a photovoltaic module, fabricated using single crystal silicon dendritic web sheet material, resulted in the identification of surface treatment to the module glass superstrate which improved module efficiencies. A final solar module environmental test, a simulated hailstone impact test, was conducted on full size module superstrates to verify that the module's tempered glass superstrate can withstand specified hailstone impacts near the corners and edges of the module. Process sequence design work on the metallization process selective, liquid dopant investigation, dry processing, and antireflective/photoresist application technique tasks, and optimum thickness for Ti/Pd are discussed. A noncontact cleaning method for raw web cleaning was identified and antireflective and photoresist coatings for the dendritic webs were selected. The design of a cell string conveyor, an interconnect feed system, rolling ultrasonic spot bonding heat, and the identification of the optimal commercially available programmable control system are also discussed. An economic analysis to assess cost goals of the process sequence is also given.

Source record↗

Dynamic Contingency Analysis Tool

The Dynamic Contingency Analysis Tool (DCAT) is an open-platform and publicly available methodology to help develop applications that aim to improve the capabilities of power system planning engineers to assess the impact and likelihood of extreme contingencies and potential cascading events across their systems and interconnections. Outputs from the DCAT will help find mitigation solutions to reduce the risk of cascading outages in technically sound and effective ways. The current prototype DCAT implementation has been developed as a Python code that accesses the simulation functions of the Siemens PSS/E planning tool (PSS/E). It has the following features: It uses a hybrid dynamic and steady-state approach to simulating the cascading outage sequences that includes fast dynamic and slower steady-state events. It integrates dynamic models with protection scheme models for generation, transmission, and load. It models special protection systems (SPSs)/remedial action schemes (RASs) and automatic and manual corrective actions. Overall, the DCAT attempts to bridge multiple gaps in cascading-outage analysis in a single, unique prototype tool capable of automatically simulating and analyzing cascading sequences in real systems using multiprocessor computers. While the DCAT has been implemented using PSS/E in Phase I of the study, other commercial software packages with similar capabilities can be used within the DCAT framework.

Source record↗

Managing Solar Photovoltaic Integration in the Western United States: Power System Flexibility Requirements and Supply

As penetrations of variable renewable energy generation technologies such as wind and solar photovoltaics (PV) continue to increase across the United States, greater uncertainty and variability in the net load often lead to a concern about how power systems may adapt. Managing the system net load (i.e., load minus contribution from variable generation technologies) may become more challenging with increasing variable generation, as the magnitude and frequency of net ramps increase. However, there is inherent flexibility in power systems through the conventional generator fleet (under least-cost unit commitment and economic dispatch), less-conventional generation sources (e.g., storage, demand response, concentrating solar power with thermal energy storage), and imports and exports with neighbors. In this analysis, we create an open-source tool to analyze the flexibility of the results of a specific commercial unit commitment and economic dispatch tool (PLEXOS), but the code can be applied generically as well. The tool assesses the flexibility requirements (or demand) of a system through a net load analysis. The constraints and limitations of each generator are then considered to determine the availability (or supply) of flexibility. Then, the supply and demand of flexibility are compared to gain a more complete picture of potential flexibility concerns. We apply this open-source tool to high-penetration PV scenarios constructed for three focus regions in the western United States defined using the Resource Planning Model (RPM) capacity expansion modeling tool: RPM-OR, RPM-CO, and RPM-AZ. Generally, we find few flexibility concerns, as the western United States represents a large and interconnected power system with significant inherent flexibility. In addition, the PV scenarios we analyzed are overbuilt on capacity, leaving plenty of ramping ability on the system. We do find that for each focus region, the impact of imports on meeting ramping needs is essential. This means the PV integration in each focus region impacts the entire rest of the system. Each system has different dominant sources of flexibility. The conventional generator fleet (especially coal and gas combined-cycle technologies) as well as less-conventional sources such as storage are all shown to be important sources of flexibility. The scenarios evaluated here were designed to study the planning and operations impact of high solar penetration in each of three focus regions. However, none of the three focus regions likely will deploy PV in isolation, meaning the ability of imports and exports to provide flexibility may be considerably different in scenarios with strong PV deployment in every region. Overall, we intend that the framework we present here will be useful in future analysis of other system evolutions to identify whether and how flexibility may constrain the successful deployment of variable generation technologies.

14 SOLAR ENERGY↗