Search NASA⌕ Search

SEARCH · Search NASA

Results for “interface characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Organizing Diverse, Distributed Project Information

SemanticOrganizer is a software application designed to organize and integrate information generated within a distributed organization or as part of a project that involves multiple, geographically dispersed collaborators. SemanticOrganizer incorporates the capabilities of database storage, document sharing, hypermedia navigation, and semantic-interlinking into a system that can be customized to satisfy the specific information-management needs of different user communities. The program provides a centralized repository of information that is both secure and accessible to project collaborators via the World Wide Web. SemanticOrganizer's repository can be used to collect diverse information (including forms, documents, notes, data, spreadsheets, images, and sounds) from computers at collaborators work sites. The program organizes the information using a unique network-structured conceptual framework, wherein each node represents a data record that contains not only the original information but also metadata (in effect, standardized data that characterize the information). Links among nodes express semantic relationships among the data records. The program features a Web interface through which users enter, interlink, and/or search for information in the repository. By use of this repository, the collaborators have immediate access to the most recent project information, as well as to archived information. A key advantage to SemanticOrganizer is its ability to interlink information together in a natural fashion using customized terminology and concepts that are familiar to a user community.

Keller, Richard M.↗

EVA Swab Tool to Support Planetary Protection and Astrobiology Evaluations

When we send humans to search for life on other planets, we'll need to know what we brought with us versus what may already be there. To ensure our crewed systems meet planetary protection requirements-and to protect our science from human contamination-we'll need to assess whether microorganisms may be leaking or venting from our spacecraft. Microbial sample collection outside of a pressurized spacecraft is complicated by temperature extremes, low pressures that preclude the use of laboratory standard (wetted) swabs, and operation either in bulky spacesuits or with robotic assistance. Engineers at the National Aeronautics and Space Administration (NASA) recently developed a swab kit for use in collecting microbial samples from the external surfaces of crewed spacecraft, including spacesuits. The Extravehicular Activity (EVA) Swab Kit consists of a single swab tool handle and an eight-canister sample caddy. The design team minimized development cost by re-purposing a heritage Space Shuttle tile repair handle that was designed to quickly snap into different tool attachments by engaging a mating device in each attachment. This allowed the tool handle to snap onto a fresh swab attachment much like popular shaving razor handles can snap onto a disposable blade cartridge. To disengage the handle from a swab, the user performs two independent functions, which can be done with a single hand. This dual operation mitigates the risk that a swab will be inadvertently released and lost in microgravity. Each swab attachment is fitted with commercially available foam swab tips, vendor-certified to be sterile for Deoxyribonucleic Acid (DNA). A microbial filter installed in the bottom of each sample container allows the container to outgas and repressurize without introducing microbial contaminants to internal void spaces. Extensive ground testing, post-test handling, and sample analysis confirmed the design is able to maintain sterile conditions as the canister moves between various pressure environments. To further minimize cost, the design team acquired extensive ground test experience in a relevant flight environment by piggy-backing onto suited crew training runs. These training runs allowed the project to validate tool interfaces with pressurized EVA gloves and collect user feedback on the tool design and function, as well as characterize baseline microbial data for different types of spacesuits. In general, test subjects found the EVA Swab Kit relatively straightforward to operate, but identified a number of design improvements that will be incorporated into the final design. Although originally intended to help characterize human forward contaminants, this tool has other potential applications, such as for collecting and preserving space-exposed materials to support astrobiology experiments.

Rucker, Michelle A.↗

EVA Swab Tool to Support Planetary Protection and Astrobiology Evaluations

When we send humans to search for life on other planets, we'll need to know what we brought with us versus what may already be there. To ensure our crewed systems meet planetary protection requirements-and to protect our science from human contamination-we'll need to assess whether microorganisms may be leaking or venting from our spacecraft. Microbial sample collection outside of a pressurized spacecraft is complicated by temperature extremes, low pressures that preclude the use of laboratory standard (wetted) swabs, and operation either in bulky spacesuits or with robotic assistance. A team at the National Aeronautics and Space Administration (NASA) recently developed a swab kit for use in collecting microbial samples from the external surfaces of crewed spacecraft, including spacesuits. The Extravehicular Activity (EVA) Swab Kit consists of a single swab tool handle and an eight-canister sample caddy. The design team minimized development cost by re-purposing a heritage Space Shuttle tile repair handle that was designed to quickly snap into different tool attachments by engaging a mating device in each end effector. This allowed the tool handle to snap onto a fresh swab end effector much like popular shaving razor handles can snap onto a disposable blade cartridge. To disengage the handle from a swab, the user performs two independent functions, which can be done with a single hand. This dual operation mitigates the risk that a swab will be inadvertently released and lost in microgravity. Each swab end effector is fitted with commercially available foam swab tips, vendor-certified to be sterile for Deoxyribonucleic Acid (DNA). A microbial filter installed in the bottom of each sample container allows the container to outgas and re-pressurize without introducing microbial contaminants to internal void spaces. Extensive ground testing, post-test handling, and sample analysis confirmed the design is able to maintain sterile conditions as the canister moves between various pressure environments. To further minimize cost, the design team acquired extensive ground test experience in a relevant flight environment by piggy-backing onto suited crew training runs. These training runs allowed the project to validate tool interfaces with pressurized EVA gloves and collect user feedback on the tool design and function, as well as characterize baseline microbial data for different types of spacesuits. In general, test subjects found the EVA Swab Kit relatively straightforward to operate, but identified a number of design improvements that will be incorporated into the final design. Although originally intended to help characterize human forward contaminants, this tool has other potential applications, such as for collecting and preserving space-exposed materials to support astrobiology experiments.

Rucker, Michelle A.↗

EVA Swab Tool to Support Planetary Protection and Astrobiology Evaluations

When we send humans to search for life on other planets, we'll need to know what we brought with us versus what may already be there. To ensure our crewed systems meet planetary protection requirements?and to protect our science from human contamination?we'll need to assess whether microorganisms may be leaking or venting from our spacecraft. Microbial sample collection outside of a pressurized spacecraft is complicated by temperature extremes, low pressures that preclude the use of laboratory standard (wetted) swabs, and operation either in bulky spacesuits or with robotic assistance. A team at the National Aeronautics and Space Administration (NASA) recently developed a swab kit for use in collecting microbial samples from the external surfaces of crewed spacecraft, including spacesuits. The Extravehicular Activity (EVA) Swab Kit consists of a single swab tool handle and an eight-canister sample caddy. The design team minimized development cost by re-purposing a heritage Space Shuttle tile repair handle that was designed to quickly snap into different tool attachments by engaging a mating device in each end effector. This allowed the tool handle to snap onto a fresh swab end effector much like popular shaving razor handles can snap onto a disposable blade cartridge. To disengage the handle from a swab, the user performs two independent functions, which can be done with a single hand. This dual operation mitigates the risk that a swab will be inadvertently released and lost in microgravity. Each swab end effector is fitted with commercially available foam swab tips, vendor-certified to be sterile for Deoxyribonucleic Acid (DNA). A microbial filter installed in the bottom of each sample container allows the container to outgas and re-pressurize without introducing microbial contaminants to internal void spaces. Extensive ground testing, post-test handling, and sample analysis confirmed the design is able to maintain sterile conditions as the canister moves between various pressure environments. To further minimize cost, the design team acquired extensive ground test experience in a relevant flight environment by piggy-backing onto suited crew training runs. These training runs allowed the project to validate tool interfaces with pressurized EVA gloves and collect user feedback on the tool design and function, as well as characterize baseline microbial data for different types of spacesuits. In general, test subjects found the EVA Swab Kit relatively straightforward to operate, but identified a number of design improvements that will be incorporated into the final design. Although originally intended to help characterize human forward contaminants, this tool has other potential applications, such as for collecting and preserving space-exposed materials to support astrobiology experiments.

planetary protection↗

Characterization of the Bridgman crystal growth process by radiographic imaging

Elemental (Ge) and alloy (PbSnTe) crystal growth that is monitored via radiography to reveal both the interface position and the shape in real time is discussed for both seeded and unseeded growth. It is concluded that the interface position and the actual growth rate of a Bridgman grown crystal is dependent on the growth conditions. The actual growth rate which is a strong function of the degree of supercooling exceeded the pull rate by a factor of greater than two. The interface shape changed from concave to flat to convex during the growth.

Fripp, Archibald L.↗

Identifying Decoherence Mechanisms in Superconducting Qubits through Advanced Materials Characterization

Although superconducting qubits have emerged as a leading technology platform for quantum computing through large improvements in device coherence times and gate fidelity in recent years, the presence of defects and impurities at the interfaces and surfaces in the constituent materials continue to limit performance and serve as a critical barrier in achieving scalable quantum systems. Understanding and eliminating these sources of quantum decoherence in superconducting qubit devices requires dedicated studies aimed at establishing robust structure-property relationships that will enable researchers to target and eliminate defects strategically. As part of the Superconducting Materials and Systems (SQMS) center, we have extensively employed state-of-the-art materials characterization techniques, including scanning/transmission electron microscopy, secondary ion mass spectrometry, atom probe tomography, x-ray diffraction, and x-ray photoelectron spectroscopy in conjunction with device measurements to elucidate such relationships. In this talk, I will discuss some of our recent findings, including linking atomic defects to microwave loss in surface oxides, linking impurities in the Josephson Junction to qubit parameters, and linking low temperature precipitates to device performance. By applying these insights, we have been able to strategically develop and implement mitigation strategies for reliable fabrication of high coherence superconducting qubits.

Murthy, A. [Fermilab] (ORCID:0000000176776866)↗

Identifying Decoherence Mechanisms in Superconducting Qubits through Advanced Materials Characterization

Although superconducting qubits have emerged as a leading technology platform for quantum computing through large improvements in device coherence times and gate fidelity in recent years, the presence of defects and impurities at the interfaces and surfaces in the constituent materials continue to limit performance and serve as a critical barrier in achieving scalable quantum systems. Understanding and eliminating these sources of quantum decoherence in superconducting qubit devices requires dedicated studies aimed at establishing robust structure-property relationships that will enable researchers to target and eliminate defects strategically. As part of the Superconducting Materials and Systems (SQMS) center, we have extensively employed state-of-the-art materials characterization techniques, including scanning/transmission electron microscopy, secondary ion mass spectrometry, atom probe tomography, x-ray diffraction, and x-ray photoelectron spectroscopy in conjunction with device measurements to elucidate such relationships. In this talk, I will discuss some of our recent findings, including linking atomic defects to microwave loss in surface oxides, linking impurities in the Josephson Junction to qubit parameters, and linking low temperature precipitates to device performance. By applying these insights, we have been able to strategically develop and implement mitigation strategies for reliable fabrication of high coherence superconducting qubits.

Murthy, A. [Fermilab] (ORCID:0000000176776866)↗

SiC Optically Modulated Field-Effect Transistor

An optically modulated field-effect transistor (OFET) based on a silicon carbide junction field-effect transistor (JFET) is under study as, potentially, a prototype of devices that could be useful for detecting ultraviolet light. The SiC OFET is an experimental device that is one of several devices, including commercial and experimental photodiodes, that were initially evaluated as detectors of ultraviolet light from combustion and that could be incorporated into SiC integrated circuits to be designed to function as combustion sensors. The ultraviolet-detection sensitivity of the photodiodes was found to be less than desired, such that it would be necessary to process their outputs using high-gain amplification circuitry. On the other hand, in principle, the function of the OFET could be characterized as a combination of detection and amplification. In effect, its sensitivity could be considerably greater than that of a photodiode, such that the need for amplification external to the photodetector could be reduced or eliminated. The experimental SiC OFET was made by processes similar to JFET-fabrication processes developed at Glenn Research Center. The gate of the OFET is very long, wide, and thin, relative to the gates of typical prior SiC JFETs. Unlike in prior SiC FETs, the gate is almost completely transparent to near-ultraviolet and visible light. More specifically: The OFET includes a p+ gate layer less than 1/4 m thick, through which photons can be transported efficiently to the p+/p body interface. The gate is relatively long and wide (about 0.5 by 0.5 mm), such that holes generated at the body interface form a depletion layer that modulates the conductivity of the channel between the drain and the source. The exact physical mechanism of modulation of conductivity is a subject of continuing research. It is known that injection of minority charge carriers (in this case, holes) at the interface exerts a strong effect on the channel, resulting in amplification of the photon-detection signal. A family of operating curves characterizing the OFET can be generated in a series of measurements performed at different intensities of incident ultraviolet light.

Tabib-Azar, Massood↗

The MOSAiC Distributed Network: Observing the coupled Arctic system with multidisciplinary, coordinated platforms

Central Arctic properties and processes are important to the regional and global coupled climate system. The Multidisciplinary drifting Observatory for the Study of Arctic Climate (MOSAiC) Distributed Network (DN) of autonomous ice-tethered systems aimed to bridge gaps in our understanding of temporal and spatial scales, in particular with respect to the resolution of Earth system models. By characterizing variability around local measurements made at a Central Observatory, the DN covers both the coupled system interactions involving the ocean-ice-atmosphere interfaces as well as three-dimensional processes in the ocean, sea ice, and atmosphere. The more than 200 autonomous instruments (“buoys”) were of varying complexity and set up at different sites mostly within 50 km of the Central Observatory. During an exemplary midwinter month, the DN observations captured the spatial variability of atmospheric processes on sub-monthly time scales, but less so for monthly means. They show significant variability in snow depth and ice thickness, and provide a temporally and spatially resolved characterization of ice motion and deformation, showing coherency at the DN scale but less at smaller spatial scales. Ocean data show the background gradient across the DN as well as spatially dependent time variability due to local mixed layer sub-mesoscale and mesoscale processes, influenced by a variable ice cover. The second case (May–June 2020) illustrates the utility of the DN during the absence of manually obtained data by providing continuity of physical and biological observations during this key transitional period. We show examples of synergies between the extensive MOSAiC remote sensing observations and numerical modeling, such as estimating the skill of ice drift forecasts and evaluating coupled system modeling. The MOSAiC DN has been proven to enable analysis of local to mesoscale processes in the coupled atmosphere-ice-ocean system and has the potential to improve model parameterizations of important, unresolved processes in the future.

54 ENVIRONMENTAL SCIENCES↗

Influence of Shear Strength Assumptions on BISON Debonding Simulations

Accurately predicting the thermomechanical response of buffer–IPyC debonding in TRISO fuel particles requires reliable mechanical property inputs for each coating layer, particularly the normal and shear strengths that influence interlayer delamination and stress concentrations. Micro tensile testing of AGR-2 fuel particles provided experimentally measured normal strengths for the buffer, IPyC, and buffer–IPyC interface; however, shear strength was not measured. As a result, BISON simulations of interface debonding must rely on assumed shear strength values, typically estimated as 20–40% of the measured ultimate tensile strength. This study evaluates how these assumed shear strength values influence cohesive zone model (CZM) predictions of buffer–IPyC separation in AGR 2 TRISO particles. Using micro tensile data from three AGR 2 compacts (2 1 3, 5 1 3, and 6 3 3), BISON simulations were performed with multiple shear strength assumptions to quantify their effect on radial and tangential stress evolution, debonding, and gap propagation. The results show that shear strength is a high sensitivity parameter: increasing the assumed shear strength significantly alters the stress distribution at the buffer–IPyC junction, shifts the predicted debonding location, and changes the extent of partial gap formation. While normal strength controls the initiation of interface separation, shear strength strongly influences the mode mixity of the failure process and the resulting stress concentrations transmitted to the IPyC and SiC layers. These findings highlight a critical gap in current TRISO mechanical characterization. Without experimentally measured shear strength, BISON simulations must rely on approximations that introduce uncertainty into predictions of coating layer integrity and fission product barrier performance. Future fuel qualification campaigns should therefore consider measurement of shear strength at the interlayer interfaces to reduce model uncertainty and improve the fidelity of TRISO fuel performance simulations.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Electric Field Induced Interfacial Instabilities

The study of the interface in a charge-free, critical and near-critical binary fluid in the presence of an externally applied electric field is presented. At sufficiently large fields, the interface between the two phases of the binary fluid should become unstable and exhibit an undulation with a predefined wavelength on the order of the capillary length. As the critical point is approached, this wavelength is reduced, potentially approaching length-scales such as the correlation length or critical nucleation radius. At this point the critical properties of the system may be affected. In this paper, the flat interface of a marginally polar binary fluid mixture is stressed by a perpendicular alternating electric field and the resulting instability is characterized by the critical electric field E(sub c) and the pattern observed. The character of the surface dynamics at the onset of instability is found to be strongly dependent on the frequency f of the field applied. The plot of E(sub c) vs. f for a fixed temperature shows a sigmoidal shape, whose low and high frequency limits are well described by a power-law relationship, E(sub c) = epsilon(exp zeta) with zeta = 0.35 and zeta = 0.08, respectively. The low-limit exponent compares well with the value zeta = 4 for a system of conducting and non-conducting fluids. On the other hand, the high-limit exponent coincides with what was first predicted by Onuki. The instability manifests itself as the conducting phase penetrates the non-conducting phase. As the frequency increases, the shape of the pattern changes from an array of bifurcating strings to an array of column-like (or rod-like) protrusions, each of which spans the space between the plane interface and one of the electrodes. For an extremely high frequency, the disturbance quickly grows into a parabolic cone pointing toward the upper plate. As a result, the interface itself changes its shape from that of a plane to that of a high sloping pyramid.

Kusner, Robert E.↗

Constitutive Modeling of the Facesheet to Core Interface in Honeycomb Sandwich Panels Subject to Mode I Delamination

A new cohesive zone traction-separation law, which includes the effects of fiber bridging, has been developed, implemented with a finite element (FE) model, and applied to simulate the delamination between the facesheet and core of a composite honeycomb sandwich panel. The proposed traction-separation law includes a standard initial cohesive component, which accounts for the initial interfacial stiffness and energy release rate, along with a new component to account for the fiber bridging contribution to the delamination process. Single cantilever beam tests on aluminum honeycomb sandwich panels with carbon fiber reinforced polymer facesheets were used to characterize and evaluate the new formulation and its finite element implementation. These tests, designed to evaluate the mode I toughness of the facesheet to core interface, exhibited significant fiber bridging and large crack process zones, giving rise to a concave downward concave upward pre-peak shape in the load-displacement curve. Unlike standard cohesive formulations, the proposed formulation captures this observed shape, and its results have been shown to be in excellent quantitative agreement with experimental load-displacement and apparent critical energy release rate results, representative of a payload fairing structure, as well as local strain fields measured with digital image correlation.

composites↗

All-Atom Modeling and Simulation of Biopolymer Interface: Dual Role of Antifouling Polymer Brushes

Antifouling polymer brushes are well-known for their exceptional resistance to unwanted protein adsorption. While experimental studies have extensively characterized protein–polymer brush interactions, computational investigations remain limited, largely due to the challenges in accurately modeling and integrating these complex, multicomponent systems without resorting to oversimplification. To address this challenge, this study presents one of the most comprehensive and realistic model systems to date, comprising the substrate, grafted polymers, and proteins. Our work interprets the interactions between polymer brush and protein based on realistic modeling without simplification. In particular, this study utilizes molecular modeling and simulation of polycationic and polyzwitterionic brushes─poly(dimethylaminoethyl methacrylate) (PDMAEMA), poly(2-(N-oxide-N,N-dimethylamino)ethyl methacrylate) (PNOMA), and poly(2-(N-3-sulfopropyl-N,N-dimethylammonium)ethyl methacrylate) (PSBMA)─grafted onto α-quartz substrates via polymerization initiator linkers. The brush models were developed to closely replicate experimentally synthesized samples and to provide detailed insights into structural and dynamical changes at the molecular level during protein adsorption. Using steered molecular dynamics simulations, we show that the PSBMA brush, due to its high local density, exhibits the greatest resistance to protein insertion. Cα root-mean-square deviation and interaction pattern analyses further reveal that the PSBMA brush also induces the most significant destabilization of lysozyme, while the PDMAEMA brush enhances protein stability through ion-mediated interactions. The PNOMA brush, while requiring the lowest force for protein adsorption, induces greater protein destabilization than the PDMAEMA brush, primarily due to electrostatic repulsion caused by a short carbon spacer length. Hydration analysis reveals that both the PSBMA brush and the lysozyme interacting with it exhibit the most rapid dehydration, attributed to the brush’s high local chain density, which results in the greatest lysozyme destabilization and the highest adsorption force. These findings highlight the dual role of antifouling polymer brushes: resisting protein adsorption and modulating protein structural dynamics. In conclusion, this study provides valuable insights for the rational design of next-generation antifouling materials and offers a framework for realistic model development in complex multicomponent systems.

Adsorption↗

A procedure concept for local reflex control of grasping

An architecture is proposed for the control of robotic devices, and in particular of anthropomorphic hands, characterized by a hierarchical structure in which every level of the architecture contains data and control function with varying degree of abstraction. Bottom levels of the hierarchy interface directly with sensors and actuators, and process raw data and motor commands. Higher levels perform more symbolic types of tasks, such as application of boolean rules and general planning operations. Layers implementation has to be consistent with the type of operation and its requirements for real time control. It is proposed to implement the rule level with a Boolean Artificial Neural Network characterized by a response time sufficient for producing reflex corrective action at the actuator level.

Fiorini, Paolo↗

Elucidating Compositional Differences in Halide Perovskites for Normal and Inverted Perovskite Solar Cells

Over the recent few years, extensive research efforts have shifted from normal (n-i-p) to inverted (p-i-n) perovskite solar cells (PSCs), owing to their promising efficiency and operational stability, enabled by low-temperature processing. Despite a fundamentally identical operation principle (only structurally inverted), the optimized perovskite compositions for normal and inverted PSCs differ significantly across the literature, suggesting an underlying design principle for perovskite composition. Here, we unveil the role of cesium cation in enhancing interfacial contact between the perovskite layer and the underlying hole-transporting layer (HTL) in inverted PSCs. Comprehensive in situ and device characterization reveal that cesium incorporation promotes the formation of initial nucleation seeds for heterogeneous nucleation at the perovskite/hydrophobic HTL interface, thereby improving their contact. The resulting compositional heterogeneity explains the focus of recent studies on resolving this issue. This study provides mechanistic insight into designing perovskite compositions to further enhance the performance and longevity of PSCs.

Park, Keonwoo↗

Tracking the dynamics of catalytic Pt/CeO2 active sites during water-gas-shift reaction

Abstract Understanding the atomistic structure of the active site during catalytic reactions is of paramount importance in both fundamental studies and practical applications, but such studies are challenging due to the complexity of heterogeneous systems. Here, we use Pt/CeO 2 as an example to study the dynamic nature of active sites during the water-gas-shift reaction (WGSR) by combining multiple in situ characterization tools. We show that the different concentrations of interfacial Pt δ+ – O – Ce 4+ moieties at Pt/CeO 2 interfaces are responsible for the rank of catalytic performance of Pt/CeO 2 catalysts: Pt/CeO 2 -rod > Pt/CeO 2 -cube > Pt/CeO 2 -oct. For all the catalysts, metallic Pt is formed during the WGSR, leading to the transformation of the active sites to Pt 0 – O v – Ce 3+ and interface reconstruction. These findings shed light on the nature of the active site for the WGSR on Pt/CeO 2 and highlight the importance of combining complementary in situ techniques for establishing structure-performance relationships.

36 MATERIALS SCIENCE↗

Space Charge Effects on Spin Polarization in High-Intensity Preinjector

This analytical study investigates the space charge impact on electron beam polarization within the low-energy range, spanning from the polarized electron gun up to the linac. The research study three sections: the gun-to-Wien filter interface, the Wien filter section, and the bunching section. We will comprehensively assess polarization degradation mechanisms in each region characterized by space charge effects. We are planning to simulate the spin tracking through the entire low-energy transmission system using Generalized Particle Tracer (GPT) to validate our analytical findings and includes the higher order components.

43 PARTICLE ACCELERATORS↗

Laser-enhanced synthesis and processing of diamond films from liquid hydrocarbons

We report synthesis of diamond films by pulsed laser irradiation on copper substrate immersed into liquid benzene. It is envisaged that carbon released from benzene at the liquid-solid interface is converted into diamond as a result of rapid quenching from a high temperature. The diamond crystallites were characterized using high resolution transmission electron microscopy imaging and electron diffraction techniques. Growth of thicker diamond films by subsequent chemical vapor deposition has been investigated by transmission and scanning electron microscopy techniques. Thin diamond film deposited during liquid phase provided seed for diamond growth during subsequent chemical vapor deposition.

Singh, Jogender↗