Search NASA⌕ Search

SEARCH · Search NASA

Results for “laboratory studies of gravity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Improving the Quasi‐Biennial Oscillation via a Surrogate‐Accelerated Multi‐Objective Optimization

Accurate simulation of the quasi-biennial oscillation (QBO) is challenging due to uncertainties in representing convectively generated gravity waves. We develop an end-to-end uncertainty quantification workflow that calibrates these gravity wave processes in E3SM for a realistic QBO. Central to our approach is a domain knowledge-informed, compressed representation of high-dimensional spatio-temporal wind fields. By employing a parsimonious statistical model that learns the fundamental frequency from complex observations, we extract interpretable and physically meaningful quantities capturing key attributes. Building on this, we train a probabilistic surrogate model that approximates the fundamental characteristics of the QBO as functions of critical physics parameters governing gravity wave generation. Leveraging the Karhunen–Loève decomposition, our surrogate efficiently represents these characteristics as a set of orthogonal features, capturing cross-correlations among multiple physics quantities evaluated at different pressure levels and enabling rapid surrogate-based inference at a fraction of the computational cost of full-scale simulations. Finally, we analyze the inverse problem using a multi-objective approach. Our study reveals a tension between amplitude and period that constrains the QBO representation, precluding a single optimal solution. To navigate this, we quantify the bi-criteria trade-off and generate a set of Pareto optimal parameter values that balance the conflicting objectives. This integrated workflow improves the fidelity of QBO simulations and offers a versatile template for uncertainty quantification in complex geophysical models.

54 ENVIRONMENTAL SCIENCES↗

Consolidation and Permeability of the B1 and D1 Gas Hydrate Bearing Sands and Associated Seal Sediments of the Extended-Duration Gas Production Test Site on the Alaska North Slope

Gas hydrate, a solid combination of gas (mostly methane in nature) and water molecules stable at low temperatures and elevated pressures, occurs naturally in marine and permafrost-associated environments. Gas hydrate reservoirs, such as those in the Alaska North Slope, have been considered potential energy resources for gas production. To understand the petrophysical and geo-mechanical characteristics of the reservoir, core samples retrieved from the site of the JOGMEC-DOE-USGS collaborative gas hydrate R&D project have been analyzed in the laboratory for their hydraulic and mechanical properties. This paper focuses on both seal and reservoir samples associated with the B1 and D1 sands, which are evaluated for index properties (including porosity, grain size distribution, liquid and plastic limits, specific surface area, and specific gravity), consolidation, permeability, and water retention. Furthermore, the reservoir core samples were tested with pore-filling, laboratory-grown tetrahydrofuran hydrate, in order to assess reservoir behavior during gas production from hydrates. Under simulated in situ stress conditions, the seal and hydrate-free reservoir cores had a permeability anisotropy ratio of k h /k v = 3.0−5.0, and k h /k v = 2.4−3.0 for the reservoir tetrahydrofuran hydrate-bearing cores. The data suggest that depressurizing the reservoir to induce hydrate dissociation alters the reservoir effective permeability in three ways: permeabilities decrease due to porosity lost (e.g., the initial reservoir thickness can decrease by up to 5% upon 7 MPa depressurization), permeability increases due to the loss of solid hydrate in the pore space, and permeability anisotropy k h /k v decreases in response to the evolving pore-space geometry. We show that given the simulated in situ gas hydrate saturations (i.e., S h = 32% in core 7P-2E and S h = 21% in core 20P-4), gas production from the dissociation of tetrahydrofuran hydrate in the two tested cores results in a net increase in effective permeability and a decrease in k h /k v . This study highlights the importance of investigating seal and reservoir sediments and the impacts of depressurization on the porosity and permeability responses during production.

Geological materials↗

Lifetime extension drop-test of real-world corroded 5 Quart Hagan nuclear material storage container

A 5Qt Hagan container with a 20-year history of nuclear material storage was challenged with three successive drop tests at a height of 3.7 meters. The total mass of the test package was 12.1 kg. The 1st and 2nd drop tests (center of gravity over the container bottom corner but 180 degrees apart on the container bottom face) passed the pre- and post- impact helium leak criterion at less than 1.00E-6 atm-cc/sec (ambient cubic centimeters per second). The 3rd and final test (center of gravity over top corner) failed with a post-impact gross leak of 1.1E-1 atmcc/sec. The RRFMC (Respirable Release Fraction Measurement Chamber) is a drop tower test system that is critical for the sustainability of the SAVY-4000™ series and Hagan-type (NFT Inc. Golden CO) nuclear material storage containers. These are the primary in-use nuclear material storage container types at the Los Alamos National Laboratory TA-55 facility. Results are presented to expand the technical knowledge basis for container lifetime, regarding actual exposure to corrosive gas species on the container inner surfaces. The primary source of general corrosion throughout the container is gaseous hydrogen chloride (HCl). This gas is generated by the degradation of the polyvinylchloride (PVC) bag-out bag. Additionally, in most cases, the nuclear material itself also releases HCl gas (due to residual chemical components associated with the material formation). The RRFMC drop tower gives the end-user the ability record and analyze high-speed video and photography and if needed aerosol mass release measurements. In this report the principal issue is the physical deformation of the 5Qt Hagan container. There were no mass release experiments of test aerosol mass in the present study.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effects of microgravity on osteoblast growth

Studies from space flights over the past two decades have demonstrated that basic physiological changes occur in humans during space flight. These changes include cephalic fluid shifts, loss of fluid and electrolytes, loss of muscle mass, space motion sickness, anemia, reduced immune response, and loss of calcium and mineralized bone. The cause of most of these manifestations is not known and until recently, the general approach was to investigate general systemic changes, not basic cellular responses to microgravity. Recently analyzed data from the 1973-1974 Skylabs disclose that there is a rise in the systemic hormone, cortisol, which may play a role in bone loss in flight. In two flights where bone growth was measured (Skylabs 3 and 4), the crew members had a significant loss of calcium accompanied by a rise in 24 hour urinary cortisol during the entire flight period. In ground-based work on osteoblasts, we have demonstrated that equivalent amounts of glucocorticoids can inhibit osteoblast cell growth. In addition, this laboratory has recently studied gene growth and activation of mouse osteoblasts (MC3T3-E1) during spaceflight. Osteoblast cells were grown on glass coverslips, loaded in the Biorack plunger boxes 18 hours before launch and activated 19 hours after launch in the Biorack incubator under microgravity conditions. The osteoblasts were launched in a serum deprived state, activated and collected in microgravity. Samples were collected at 29 hours after sera activation (0-g, n=4; 1-g, n=4). The osteoblasts were examined for changes in gene expression and cell morphology. Approximately one day after growth activation, remarkable differences were observed in gene expression in 0-g and 1-g flight samples. The 0-g activated cells had increased c-fos mRNA when compared to flight 1-g controls. The message of immediate early growth gene, cox-2 was decreased in the microgravity activated cells when compared to ground or 1-g flight controls. Cox-1 was not detected in any of the samples. There were no significant differences in the expression of actin mRNA between the 0-g and 1-g samples. These data indicate that quiescent osteoblasts are slower to enter the cell cycle in microgravity, suggesting that the force of gravity itself may be a significant factor in bone loss in spaceflight. Preliminary data from our STS 76 flight experiment support our hypothesis that a basic biological response occurs at the tissue, cellular, and molecular level in 0-g. Here we examine ground-based and space flown data on osteoblast growth in ground-based experiments mimicking space flight conditions and in microgravity to simulate lack of gravity stress to help us understand the mechanism of bone loss by experiments.

NASA Experiment Number 9403056↗

Gravity Well Commercial Economics Assessment: Potential Revenue and Cost: Cooperative Research and Development (Final Report)

In the Gravity Well Revenue Study, we evaluate the potential revenue from energy storage using historical energy-only electricity prices, forward-looking projections of hourly electricity prices, and actual reported revenue. This analysis examines the impact of storage duration and round-trip efficiency, as well as the location of the storage, on storage revenue within the current and projected U.S. power system. We also investigated the impact of round-trip efficiency on storage revenue. We found that the relationship between storage revenue and round-trip efficiency is nonlinear. The value of improved round-trip efficiency declines as round-trip efficiency increases. In the Gravity Well Future Cost Study, we applied learning curves to predict the future cost trajectory of Gravity Wells (GrWs). Two types of analysis were implemented. The first was a bottom-up analysis that used historical learning rates for cost components, such as motors and gearboxes, and cost categories (e.g., engineering and design, etc.) to determine the learning-by-doing based single-factor learning curve. The single factor learning curve expresses the relationship between the cost of GrW and the number of units deployed (or the cumulative capacity). In the second analysis, we predicted future GrW costs via a top-down approach. This approach accounts for historical cost trends in other renewable energy and storage technologies, which have similarities with GrWs. Using a multifactor learning curve that accounts for both intrinsic (cumulative capacity) and extrinsic (the elasticity in the price of steel) factors, we estimated the future cost of GrWs.

25 ENERGY STORAGE↗

Experimental investigation on heat transfer performance of drain water heat recovery heat exchangers

Water heating accounts for 18 % of residential energy consumption, and a substantial portion of this energy can be recovered through drain water heat recovery systems. Here, this paper investigates the heat transfer performance of drain water heat recovery heat exchangers. Two heat exchanger configurations were studied: vertical (gravity film exchanger) and horizontal. The heat recovery performance of the exchangers was quantified using sensible effectiveness and characteristic curves following the ε-NTU approach. Depending on the flow conditions, heat exchangers with a vertical configuration offered higher heat transfer effectiveness compared with the horizontal configuration under similar operating conditions. Furthermore, the results showed that properly designed and sized heat exchangers can effectively recover considerable amounts of waste heat from drains, depending on flow rates. Additionally, in the vertical heat exchanger configuration, low flow rates result in partially wet conditions, resulting in lower heat transfer effectiveness. Therefore, two distributor configurations are proposed to improve the heat transfer performance of vertically configured heat exchangers at low flow rates. The proposed distributor configurations and data presented in this paper will be useful in the design and development of drain water heat recovery systems in building applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dust-void evolution driven by turbulent dust flux can induce runaway migration of Earth-mass planets

Torques from asymmetric dust structures (so-called dust-void and filamentary structures) formed around low-mass planets embedded in a nonturbulent dust-gas disk can exceed the torques produced by the gas disk component and then go on to dominate the planet’s orbital dynamics. Here, we investigate how these structures (hence the dust torque) change when the effect of turbulent dust diffusion and dust feedback are included, along with the direct implications on the migration of Earth-like planets. Using the FARGO3D code, we performed 2D and 3D multifluid hydrodynamic simulations, focusing on a non-migrating planet with a mass of M p = 1.5 M ⊕ in 2D and on migrating planets with M p ∈ [1.5, 12] M ⊕ in 3D. We varied the δ-dimensionless diffusivity parameter in the range [0, 3 × 10 −3 ] and considered three different Stokes numbers, St = {0.04, 0.26, 0.55}, which are representative of the gas-dominated, the transitional, and the gravity-dominated regimes, respectively. In our 2D models, we find that turbulent diffusion of dust prevents the formation of the dust-void and filamentary structures when δ > 3 × 10 −4 . Otherwise, dust structures survive turbulent diffusion flow. However, dust and total torques become positive only in transitional and gravity-dominated regimes. In our 3D models, we find that the dust-void is drastically modified and the high-density ring-shaped barrier delineating the dust-void disappears if δ ≳ 10 −4 , due to the effect of dust turbulent diffusion along with the back-reaction of the dust. For all values of δ, the filament in front of the planet is replaced by a low-density trench. Remarkably, as we have allowed the planets to migrate, the evolving dust-void can drive either runaway migration or outward (inward) oscillatory-torque migration. Our study thus suggests that low-mass Earth-like planets can undergo runaway migration in dusty disks.

79 ASTRONOMY AND ASTROPHYSICS↗

Risk of Crew Adverse Health Event Due to Altered Immune Response

Determining the effect of space travel on the human immune system has proven to be extremely challenging. Limited opportunities for in-flight studies, varying mission durations, technical and logistical obstacles, small subject numbers, and a broad range of potential assays have contributed to this problem. Additionally, the inherent complexity of the immune system, with its vast array of cell populations, sub-populations, diverse regulatory molecules, and broad interactions with other physiological systems, makes determining precise variables to measure very difficult. There is also the challenge of determining the clinical significance of any observed immune alterations. Will such a change lead to disease, or is it a transient subclinical observation related to short-term stress? The effect of this problem may be observed by scanning publications associated with immunity and spaceflight, which began to appear during the 1970s. Although individually they are each valid studies, the comprehensive literature to date suffers from widely varying sampling methods and assay techniques, low subject counts, and sometimes a disparate focus on narrow aspects of immunity. The most clinically relevant data are derived from in-flight human studies, which have demonstrated altered cell-mediated immunity and reactivation of latent herpes viruses. Much more data are available from post-flight testing of humans, with clear evidence of altered cytokine production patterns, altered leukocyte distribution, continued latent viral reactivation, and evidence of dramatically altered virus-specific immunity. It is unknown if post-flight assessments relate to the in-flight condition or are a response to landing stress and readaptation. In-flight culture of cells has clearly demonstrated that immune cells are gravity-sensitive and display altered functional characteristics. It is unknown if these data are related to in vivo immune cell function or are an artifact of microgravity culture. Ground analog testing of humans and animals, as well as microgravity-analog cell culture, has demonstrated utility. However, in all cases, it is not known with certainty if these data would reflect similar testing during space travel. Given their ready availability, ground analogs may be extremely useful for assay development and the evaluation of potential countermeasures. In general, the evidence base suffers from widely disparate studies on small numbers of subjects that do not directly correlate well with each other or spaceflight itself. Also lacking are investigations of the effect of gender on adaption to spaceflight. This results in significant knowledge 'gaps' that must be filled by future studies to completely determine any clinical risk related to immunity for human exploration-class space missions. These gaps include a significant lack of in-flight data, particularly during long-duration space missions. The International Space Station represents an excellent science platform with which to address this knowledge gap. Other knowledge gaps include lack of a single validated ground analog for the phenomenon and a lack of flight-compatible laboratory equipment capable of monitoring astronauts (for either clinical or research purposes). However, enough significant data exist, as described in this manuscript, to warrant addressing this phenomenon during the utilization phase of the ISS. A recent Space Shuttle investigation has confirmed the 31 in-flight nature of immune dysregulation, demonstrating that it is not merely a post-flight phenomenon. Several current studies are ongoing onboard the ISS that should thoroughly characterize the phenomenon. NASA recognizes that if spaceflight-associated immune dysregulation persists during exploration flights in conjunction with other dangers, such as high-energy radiation, the result may be a significant clinical risk. This emphasizes the need for a continued integrated comprehensive approach to determining the effect of prolonged spaceflight, separated from transient launch and landing stresses, on human immunity. After such studies, the phenomenon will be understood, and, hopefully, a monitoring strategy will have been developed that could be used to monitor the effectiveness of countermeasure

Crucian, Brian↗

Geomagnetic Variability and Predictability

The Earth's magnetic field varies on time scales from seconds to millions of years. These variations can be measured directly by ground observatories and satellites, and indirectly through laboratories. They are from different electromagnetic processes in magnetosphere and ionosphere (external), ocean and crust (surface), and deep in the Earth's fluid outer core (internal). Of the measured magnetic signals, 95% is from the core, and is called the core field, or internal field. Variation of the core field, often called the geomagnetic secular variation (SV), is the manifestation of the magnetohydrodynamic processes in the core. Therefore, SV provides rich information on the core dynamical state that is then critical for understanding the geophysical mechanisms of the SV, the core-mantle interactions, and contribution of mass transport inside the core on Earth's gravity variation. Traditionally, the core state is probed via two independent methodologies: core flow inversion from the observed SV, and pure numerical dynamo simulation. The former is driven by observations, but does not include necessary interactions among physical variables; the latter is dynamically consistent, but is not constrained by any observation. Therefore, both are very limited in providing appropriate estimates of the core state. To avoid these limitations, a new approach, geomagnetic data assimilation, appears recently. In this approach, simulation results (model forecasts) are constantly corrected with observations, the corrected solutions (analysis), are then used as the initial conditions to make more accurate forecasts of future. Recent studies have demonstrated successfully that assimilation solutions are different from those of free running models. These new solutions are better estimates of the core state, and have been used to provide accurate prediction of SV for the period from 2010 to 2015. This prediction is part of the IGRF field model for international community applications.

Kuang, Weijia↗

Oxidative Stress and Neuroconsequences of the Spaceflight Environment –A 5-ion GCRsim Dose-response Study

The overall scope of this project is to test the hypothesis that Ionizing Radiation (IR), microgravity and social isolation combine synergistically to trigger an oxidative stress response that alters immune homeostasis, brain structure/function, and neurobehavioral/cognitive performance. Specific Aims for this project are to: (1) Determine dose-response curves for acute ‘Five-Ion GCR Simulation’ exposure for immune, brain and performance responses in crew age-matched adult male and female mice; (2) Determine effects of acute ‘Five-Ion GCR Simulation’ exposure singly and in combination with simulated microgravity and social isolation, on immune, brain and performance responses in crew age-matched male and female mice mimicking deep space missions; and (3) Determine efficacy of the dietary antioxidant, Nicotinamide Mononucleotide (NMN), a key intermediate in nicotinamide adenine dinucleotide (NAD+) biosynthesis. Here we exposed mature (23-24-week-old) male and female mice to simulated 5-Ion GCR (either 0, 5, 15, or 50cGy) at the NASA Space Radiation Laboratory (NSRL). Across ‘Acute’ (IR+72hrs and IR+14 days) and ‘Delayed’ (IR+28 to IR+124 days) phases of the 6-month-long study, we assessed immune, neural, and functional (sensorimotor/behavioral/cognitive) responses anticipated during a transit to Mars. This presentation will report on dose-response curves for 5-ion GCRsim related to potential biomarkers; structural/functional changes in the immune and nervous systems; and behavioral/cognitive performance deficits. This project addresses NASA’s efforts to characterize risks and identify appropriate countermeasures in anticipation of future deep space missions. Ensuring crew health and performance during extended transits necessitates that sensorimotor and cognitive abilities remain strong to avoid potentially catastrophic health and safety outcomes.

deep space↗

Maglev Facility for Simulating Variable Gravity

An improved magnetic levitation apparatus ("Maglev Facility") has been built for use in experiments in which there are requirements to impose variable gravity (including zero gravity) in order to assess the effects of gravity or the absence thereof on physical and physiological processes. The apparatus is expected to be especially useful for experiments on the effects of gravity on convection, boiling, and heat transfer in fluids and for experiments on mice to gain understanding of bone loss induced in human astronauts by prolonged exposure to reduced gravity in space flight. The maglev principle employed by the apparatus is well established. Diamagnetic cryogenic fluids such as liquid helium have been magnetically levitated for studying their phase transitions and critical behaviors. Biological entities consist mostly of diamagnetic molecules (e.g., water molecules) and thus can be levitated by use of sufficiently strong magnetic fields having sufficiently strong vertical gradients. The heart of the present maglev apparatus is a vertically oriented superconducting solenoid electromagnet (see figure) that generates a static magnetic field of about 16 T with a vertical gradient sufficient for levitation of water in normal Earth gravity. The electromagnet is enclosed in a Dewar flask having a volume of 100 L that contains liquid helium to maintain superconductivity. The Dewar flask features a 66-mm-diameter warm bore, lying within the bore of the magnet, wherein experiments can be performed at room temperature. The warm bore is accessible from its top and bottom ends. The superconducting electromagnet is run in the persistent mode, in which the supercurrent and the magnetic field can be maintained for weeks with little decay, making this apparatus extremely cost and energy efficient to operate. In addition to water, this apparatus can levitate several common fluids: liquid hydrogen, liquid oxygen, methane, ammonia, sodium, and lithium, all of which are useful, variously, as rocket fuels or as working fluids for heat transfer devices. A drop of water 45 mm in diameter and a small laboratory mouse have been levitated in this apparatus.

Liu, Yuanming↗

The Investigation of the Effects of Gravity on Single Bubble Sonoluminescence

In single bubble following it's rapid collapse each cycle of oscillation of an ultrasonic field. Since widely varying length and time scales affect the bubble dynamics and optical emission processes, it is difficult to anticipate the importance of the effects of gravity present for observations on earth. Our bubble is driven in an acoustically resonating cavity at it's first harmonic mode. The acoustical radiation pressure (Bjerknes force) will then keep it suspended in the center near the pressure antinode. When driven in a region where the diffusive processes balance the bubble it acts in a nonlinear but regular way, emitting a short (approx. 200ps) burst of light each acoustic cycle. Balancing the Bjerknes force with buoyancy, as in, we can see that the bubble should be displaced from the velocity node approximately 20m at normal gravity. Therefore, water flows past the bubble at the time of collapse. Gravitation also changes the ambient pressure at the bubble's location, as Delta.P = rho.g.h this gives a change of approximately -0.5% in our experiment when going from 1.8g to 0g. Studies of ambient pressure changes were also done in order to assess these effects. Inside a pressure sealed chamber a spherical glass cell is filled with distilled water which has been degassed to 120mmHg. A bubble is then trapped in the center and driven by a piezoelectric transducer at 32.2kHz attached to the side of the cell. An optical system is then set up to take strobbed video images along and light emission data simultaneously. Temperature, pressure, drive voltage, and listener voltage are also monitored. PMT output in Volts The radii of the bubbles for both experiment s are fit using the Rayleigh-Plesset equation and the acoustic drive amplitude and the ambient bubble radius are found. There is little change in the acoustic drive amplitude as we expect, since we are not varying the drive voltage. However. the ambient bubble radius goes up considerably. These changes (increased light output, increased maximum bubble radius, and increased ambient bubble radius) are also observed when the ambient pressure is varied in the laboratory by an amount similar to that due to gravitation. The changes in the ambient bubble radius and light output with a change in ambient pressure are predicted by the "dissociation hypothesis" and have been observed by other groups in the laboratory. It seems clear that buoyancy's effect on light output and bubble radius, are at best on the same order as the effects of ambient pressure.

Dzikowicz, Ben↗

The BIRDIES Experiment: Measuring Beryllium Isotopes to Resolve Dynamics in the Stratosphere

Cosmogenic beryllium-10 and beryllium-7, and the ratio of the two (10Be/7Be), are powerful atmospheric tracers of stratosphere–troposphere exchange (STE) processes; however, measurements are sparse for altitudes well above the tropopause. We present a novel high-altitude balloon campaign aimed to measure these isotopes in the mid-stratosphere called Beryllium Isotopes for Resolving Dynamics in the Stratosphere (BIRDIES). BIRDIES targeted gravity waves produced by tropopause-overshooting convection to study their propagation and impact on STE dynamics, including the production of turbulence in the stratosphere. Two custom-designed payloads called FiSH and GASP were flown at altitudes approaching 30 km to measure in situ turbulence and beryllium isotopes (on aerosols), respectively. These were flown on nine high-altitude balloon flights over Kansas, USA, in summer 2022. The atmospheric samples were augmented with a ground-based rainfall collection targeting isotopic signatures of deep convection overshooting. Our GASP samples yielded mostly negligible amounts of both 10Be and 7Be collected in the mid-stratosphere but led to design improvements to increase aerosol capture in low-pressure environments. Observations from FiSH and the precipitation collection were more fruitful. FiSH showed the presence of turbulent velocity, temperature, and acoustic fluctuations in the stratosphere, including length scales in the infra-sonic range and inertial subrange that indicated times of elevated turbulence. The precipitation collection, and subsequent statistical analysis, showed that large spatial datasets of 10Be/7Be can be measured in individual rainfall events with minimum terrestrial contamination. While the spatial patterns in rainfall suggested some evidence for overshooting convection, inter-event temporal variability was clearly observed and predicted with good agreement using the 3D chemical transport model GEOS-CHEM.

58 GEOSCIENCES↗

Evaluation of a frequency-dependent phase shift in chirped Raman lasers for atom gravimeters

Light-pulse atom gravimetry has emerged as a powerful technique for precisely measuring absolute gravitational acceleration. Raman lasers are commonly used in this technique to coherently manipulate the atomic wave packet, of which the effective frequency is chirped continuously to compensate for the Doppler shift. In this study we investigate an additional phase shift in the Raman lasers that arises due to the frequency chirp. Here, we directly measure this phase shift by recording the beat signal of the Raman lasers with a high-speed oscilloscope, providing an independent evaluation of the resultant error in atom gravimeters caused by this phase shift. Concurrently, we detect the influence of the additional phase shift on gravity measurements using our atom gravimeter, and the results are in good agreement with the independent evaluation. Notably, there may still be a residual error at the microgal level when performing differential measurements by reversing the direction of the effective wave vector of the Raman lasers. We propose that this residual error can in principle be eliminated by selecting the same chirp frequency range for both directions in the differential measurement.

Xu, Yaoyao [Huazhong Univ. of Science and Technolo↗

Small-Scale Density Variations in the Lunar Crust Revealed by GRAIL

Data from the Gravity Recovery and Interior Laboratory (GRAIL) mission have revealed that approximately 98 percent of the power of the gravity signal of the Moon at high spherical harmonic degrees correlates with the topography. The remaining 2 percent of the signal, which cannot be explained by topography, contains information about density variations within the crust. These high-degree Bouguer gravity anomalies are likely caused by small-scale (10's of km) shallow density variations. Here we use gravity inversions to model the small-scale three-dimensional variations in the density of the lunar crust. Inversion results from three non-descript areas yield shallow density variations in the range of 100-200 kg/m3. Three end-member scenarios of variations in porosity, intrusions into the crust, and variations in bulk crustal composition were tested as possible sources of the density variations. We find that the density anomalies can be caused entirely by changes in porosity. Characteristics of density anomalies in the South Pole-Aitken basin also support porosity as a primary source of these variations. Mafic intrusions into the crust could explain many, but not all of the anomalies. Additionally, variations in crustal composition revealed by spectral data could only explain a small fraction of the density anomalies. Nevertheless, all three sources of density variations likely contribute. Collectively, results from this study of GRAIL gravity data, combined with other studies of remote sensing data and lunar samples, show that the lunar crust exhibits variations in density by plus or minus 10 percent over scales ranging from centimeters to 100’s of kilometers.

J C Jansen↗

The Dark Energy Spectrographic Instrument (DESI) Optical Fiber System

The specific research of the DESI project is to study in detail the expansion history of the Universe over the past 10 billion years. In order to do this, the project designed, fabricated, tested and commissioned the DESI instrument which has been deployed at the Mayall Telescope at the Kitt Peak National Observatory near Tucson, Arizona. The DESI project was conducted by approximately 30 US and foreign national laboratories. The complete instrument includes a prime focus corrector assembly, a focal plane with 5,000 optical fibers whose position can be set by robotic positioners, and ten spectrographs. Each spectrograph can accommodate the light from 500 fibers and include three color channels that are illuminated by a common collimator mirror and other planar transfer optics. In order for this entire system to work, optical fibers are required to connect each positioner to the spectrographs. Our CRADA with Durham University in the UK provided the 10 crucial fiber cables required to connect the DESI focal plane to the 10 spectrographs. The key major goals of this CRADA were achieved. Survey planning was another key component to the Durham contribution. Drs. Frenk, Baugh, Cole, Edge, Lacey, Li, Lucey, Massey, Metcalfe, Norberg and Shanks were all important contributors to the working groups to which they were assigned. Their work to implement emission lines and QSO in lightcone mocks, mocks for non-standard cosmologies/modified gravity, optimization of completeness of BGS in crowded regions and extended source photometry have been vital in the early planning for targets during commissioning. The major role in the project involved Dr. Ray Sharples and his team. They provided a significant portion of the design, fabrication and testing of the optical fiber system. In particular, they were responsible for the design, production of engineering drawings, component procurements, and fabrication of the 10 DESI Science fiber cables. Working in close collaboration with Dr. Claire Poppett, they also designed and fabricated the slit assemblies, the specialized termination of the groups of 500 fibers which plug into the spectrographs.

47 OTHER INSTRUMENTATION↗

Kinetic Simulations of the Kruskal–Schwarzschild Instability in Accelerating Striped Outflows: Dynamics and Energy Dissipation

Astrophysical relativistic outflows are launched as Poynting-flux dominated, yet the mechanism governing efficient magnetic dissipation, which powers the observed emission, is still poorly understood. We study magnetic energy dissipation in relativistic "striped" jets, which host current sheets separating magnetically dominated regions with opposite field polarity. The effective gravity force g in the rest frame of accelerating jets drives the Kruskal–Schwarzschild instability (KSI), a magnetic analog of the Rayleigh–Taylor instability. By means of 2D and 3D particle-in-cell simulations, we study the linear and nonlinear evolution of the KSI. The linear stage is well described by linear stability analysis. The nonlinear stages of the KSI generate thin (skin-depth-thick) current layers, with length comparable to the dominant KSI wavelength. There, the relativistic drift-kink mode and the tearing mode drive efficient magnetic dissipation. The dissipation rate can be cast as an increase in the effective width Δ eff of the dissipative region, which follows dΔ eff /dt ≃ 0.05 $\sqrt{Δ_{eff} g}$. Our results have important implications for the location of the dissipation region in gamma-ray burst and active galactic nuclei jets.

79 ASTRONOMY AND ASTROPHYSICS↗

Gravitational Biology Facility on Space Station: Meeting the needs of space biology

The Gravitational Biology Facility (GBF) is a set of generic laboratory equipment needed to conduct research on Space Station Freedom (SSF), focusing on Space Biology Program science (Cell and Developmental Biology and Plant Biology). The GBF will be functional from the earliest utilization flights through the permanent manned phase. Gravitational biology research will also make use of other Life Sciences equipment on the space station as well as existing equipment developed for the space shuttle. The facility equipment will be developed based on requirements derived from experiments proposed by the scientific community to address critical questions in the Space Biology Program. This requires that the facility have the ability to house a wide variety of species, various methods of observation, and numerous methods of sample collection, preservation, and storage. The selection of the equipment will be done by the members of a scientific working group (5 members representing cell biology, 6 developmental biology, and 6 plant biology) who also provide requirements to design engineers to ensure that the equipment will meet scientific needs. All equipment will undergo extensive ground based experimental validation studies by various investigators addressing a variety of experimental questions. Equipment will be designed to be adaptable to other space platforms. The theme of the Gravitational Biology Facility effort is to provide optimal and reliable equipment to answer the critical questions in Space Biology as to the effects of gravity on living systems.

Allen, Katherine↗