Search NASA⌕ Search

SEARCH · Search NASA

Results for “matrix sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

WSi2 in Si(1-x)Ge(x) Composites: Processing and Thermoelectric Properties

Traditional SiGe thermoelectrics have potential for enhanced figure of merit (ZT) via nano-structuring with a silicide phase, such as WSi2. A second phase of nano-sized silicides can theoretically reduce the lattice component of thermal conductivity without significantly reducing the electrical conductivity. However, experimentally achieving such improvements in line with the theory is complicated by factors such as control of silicide size during sintering, dopant segregation, matrix homogeneity, and sintering kinetics. Samples were prepared using powder metallurgy techniques; including mechano-chemical alloying, via ball milling, and spark plasma sintering for densification. Processing, micro-structural development, and thermoelectric properties will be discussed. Additionally, couple and device level characterization will be introduced.

Thermoelectric Power Generation↗

Experimental Investigation of Cement Hydration in Gravity-Free Environment

In this work, cement hydration in terrestrial and microgravity environment was compared. This was for the first time, when the International Space Station was utilized to fully investigate the complex process of cement solidification. Microstructural development of hydrating cement occurs in stages during the hydration reaction and hardening process, which results in elaborate combinations of amorphous and crystalline phases. The morphology, volume fraction, and distribution of these phases ultimately determine the hardened cement’s material properties. Minimizing gravity-driven phenomena, such as thermosolutal convective flow and sedimentation ensures crystal growth strictly by diffusion and a microstructure forms differently from that observed in typical laboratory conditions on Earth. A test matrix was developed that includes samples with various w/c ratio and various compositions; incorporating alite, pure water and cement system, cement with chemical admixtures, as well as commercial products. This paper reports on main changes initially observed in the microstructural development of hydrated pure compound of tricalcium silicate (C3S).

Neves, Juliana↗

Cyclic bend over sheave performance of a steel tension member belt for wave energy conversion

Rotary power take-offs (PTOs) promise many benefits for commercial wave energy converters (WECs), including longer power strokes/reduced end-stop concerns, deployment advantages, and controllability. However, these winch-type PTOs can impose millions of bending cycles on the belt or rope element every year, which may lead to a failure mode known as Cyclic Bend Over Sheave, or “CBOS”. Synthetic rope, though attractive due to its high strength, low elongation, and durability, suffers from comparatively poor CBOS performance and struggles to reach a million load cycles without failing. Using belts instead of ropes for winching elements should improve CBOS performance due to having a smaller thickness that undergoes bending. Unfortunately, belts have their own host of problems. Maintaining even tension across the width of a belt subject to twist or fleet angles is a challenge, especially for WECs which can move in all 6 degrees of freedom in the ocean. This study sought to quantify the CBOS performance of a belt constructed of steel tension members in a polyurethane matrix containing longitudinal profiles. Belt samples were tested to failure or up to two million bend-unbend cycles and subject to a range of fleet angles. This paper summarizes the utilized testing methodology and the resulting belt performance.

16 TIDAL AND WAVE POWER↗

Calcium fluoride as a dominating matrix for quantitative analysis by laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS): A feasibility study

Here, calcium fluoride formed by the reaction between ammonium bifluoride and calcium chloride was investigated as a dominating matrix for quantitative analysis by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). Transformation from a solid sample to the calcium fluoride-based matrix permitted quantitative analysis based on calibration standards made from elemental standards. A low abundance stable calcium isotope, i.e. 44 Ca + , was monitored as the internal standard for quantitative analysis by LA-ICP-MS. Correlation coefficient factors for multiple elements were obtained with values over 0.999. The results for multiple elements in a certified reference material of soil (NIST SRM 2710a) agreed with the certified values in the range of expanded uncertainty, indicating the present method was valid for quantitation of elements in solid samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling 2-D jets impinging on Stirling regenerators

The extent to which flow leaving Stirling coolers or heaters in the form of high-velocity jets penetrate the regenerator matrix is visually modeled using a computer program. Two-dimensional laminar jets are shown impinging on regenerator samples of variable permeability ranging from no matrix at all to matrices dense enough to stop the jet dead on. The results lend credibility to a simple tension for flow uniformity as a function of penetration depth.

Gedeon, David↗

Doping Effect of Fe Ions on the Structural, Electrical, and Magnetic Properties of SrTiO{sub 3} Nanoceramic Matrix

In the present investigation, strontium titanate nanoceramic was synthesized by incorporating iron (Fe) ion with general formula SrTi{sub 1−x}Fe{sub x}O{sub 3} (x = 0.0, 0.1, 0.2, and 0.4) using sol-gel autocombustion method. The effect of Fe ions on the structural, morphological, electrical, dielectric, and magnetic properties of the prepared matrix has been investigated by various characterization techniques with the appropriate formulation. The structural properties such as phase space, crystallite size (D), and lattice parameter (a) of prepared matrix are calculated by X-ray diffraction (XRD) technique. The functional groups were analyzed by Fourier transform infrared spectroscopy (FT-IR). The surface morphology of the prepared nanoceramic matrix has been determined by using field emission scanning electron microscopy (FE-SEM) analysis. Calculation of average particle size and diffraction patterns was confirmed by using images from transmission electron microscopy (TEM) and selected area electron diffraction pattern (SAED), respectively. An energy dispersive spectrum analysis (EDS) confirmed the compositional stoichiometry in the investigated matrix. Electrical conductivity increased the prepared sample due to the increasing in the Fe concentration and temperature. The dielectric parameters in the frequency range of 30 Hz to 1 MHz were found higher at lower frequencies. The pure SrTiO{sub 3} matrix shows a paramagnetic nature at room temperature, but for a higher concentration of Fe doping was used to observe the weak ferromagnetic nature. Therefore, due to Fe ion concentration, the properties of the prepared matrix have been completely varied and enhancement in the magnetic properties was observed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Quantitative Structure Determination from Experimental Four-Dimensional Scanning Transmission Electron Microscopy via the Scattering Matrix

Considerable inroads have recently been made on algorithms to determine the sample potential from four-dimensional scanning transmission electron microscopy data from thick samples where multiple scattering cannot be neglected. This paper further develops the scattering matrix approach to such structure determination. Through simulation, we demonstrate how this approach can be modified to better handle partial spatial coherence, unknown probe defocus, and information from the dark field region. By combining these developments we reconstruct the electrostatic potential of a monolithic SrTiO 3 crystal showing good quantitative agreement with the expected structure.

4D STEM↗

Experiment M0003-10: Advanced composites

The Advanced composites Sub-experiment includes numerous metal matrix composites, primarily graphite fiber reinforced aluminum and magnesium, and several classes of graphite fiber reinforced organic matrix (epoxy, polysulfone, polyimide) composites with and/or without thermal control or protective coatings. The experiment included over 500 flight samples, mounted on the leading and trailing edges of LDEF, and a full complement of the laboratory control samples. Preliminary results are presented reviewing changes in the visual appearance of the samples, atomic oxygen erosion of the organic matrix composites, contamination effects, and the effects of micrometeorite impacts and thermal fatigue on the metal matrix composites.

Steckel, Gary L.↗

Results of the Aerosol Sampling Experiment on the International Space Station

The indoor air quality of the International Space Station (ISS), in terms of particulate matter, has been assessed through a sampling experiment that collected airborne debris for return to Earth. The Aerosol Sampling Experiment took place on ISS in December 2016 and January 2017, with sample return in February 2017. For redundancy, two different aerosol samplers collected particles in two size ranges spanning from 10 nm to hundreds of micrometers. Multiple analysis techniques have been used to characterize the particles, such as reflective light microscopy, manual scanning electron microscopy (SEM) analysis (secondary and backscattered imaging) with energy dispersive spectroscopy (EDS) x-ray analysis, computer controlled scanning electron microscopy (CCSEM) and Raman spectroscopy. Sampling took place in five locations on ISS, with the greatest deposition of particles in Node 3, followed by Node 1, the US Lab and Node 2. The PMM had very few airborne particles, as expected, owing to the lack of human presence. A large proportion of the sampled material consisted of fibers from clothing. Many particles had complex morphologies or contained multiple metals in a carbonaceous matrix. Metal particles were analyzed for each sampling location in terms of both weight and number percent, with 27 heavy metals detected. Fiberglass and TiO2 particles were present in every location. Quantitative analysis results are presented, and where possible, particle emission sources are identified with the intention to fuel discussions on mitigation.

Meyer, Marit E.↗

Thermoplastic coating of carbon fibers

Now that quantities of prepreg were made on the thermoplastic coating line, they are being formed into both textile preform structures and directly into composite samples. The textile preforms include both woven and knitted structures which will be thermoformed into a finished part. In order to determine if the matrix resin is properly adhering to the fibers or if voids are being formed in the coating process, the tensile strength and modulus of these samples will be tested. The matrix uniformity of matrix distribution in these samples is also being determined using an image analyzer.

Edie, D. D.↗

Determination of interfacial mechanical properties of ceramic composites by the compression of micro-pillar test specimens

A novel method to determine the fiber-matrix interfacial properties of ceramic matrix composites is proposed and evaluated; where micro- pillar samples containing inclined fiber/matrix interfaces were prepared from a SiC fiber reinforced SiC matrix composites then compression-tested using the nano-indentation technique. This new test method employs a simple geometry and mitigates the uncertainties associated with complex stress state in the conventional single filament push-out method for the determination of interfacial properties. Based on the test results using samples with different interface orientations , the interfacial debond shear strength and the internal friction coefficient are explicitly determined and compared with values obtained by other test methods.

Shih, Chunghao↗

Windowed multipole representation of R -matrix cross sections

Nuclear cross sections are basic inputs to any nuclear computation. Campaigns of experiments are fitted with the parametric R-matrix model of quantum nuclear interactions, and the resulting cross sections are documented—both pointwise and as resonance parameters (with uncertainties)—in standard evaluated nuclear data libraries (ENDF, JEFF, BROND, JENDL, CENDL, TENDL): these constitute our common knowledge of fundamental low-energy nuclear cross sections. In the past decade, a collaborative effort has been deployed to establish a new nuclear cross-section library format—the Windowed Multipole Library—with the goal of considerably reducing the computational cost of cross-section calculations in nuclear transport simulations. This work lays the theoretical foundations underpinning these efforts. From general R-matrix scattering theory, we derive the windowed multipole representation of nuclear cross sections. Though physically and mathematically equivalent to R-matrix cross sections, the windowed multipole representation is particularly well suited for subsequent temperature treatment of angle-integrated cross sections, in particular Doppler broadening, which is the averaging of cross sections over the thermal motion of the target atoms. Doppler broadening is of critical importance in neutron transport applications, as it ensures the stability of many nuclear reactors (negative thermal reactivity). Yet, Doppler broadening of nuclear cross sections has been a considerable bottleneck for nuclear transport computations, often requiring memory-costly pretabulations. We show that the windowed multipole representation can perform accurate Doppler broadening analytically (up to the first reaction threshold), from which we derive cross-section temperature derivatives to any order—all computable on the fly (without precalculations stored in memory). Furthermore, we here establish a way of converting the R-matrix resonance parameters uncertainty (covariance matrices) into windowed multipole parameters uncertainty. We show that generating stochastic nuclear cross sections by sampling from the resulting windowed multipole covariance matrix can reproduce the cross-section uncertainty in the original nuclear data file. The windowed multipole representation is therefore a novel nuclear physics formalism able to generate Doppler broadened stochastic nuclear cross sections on the fly, unlocking breakthrough computational gains for nuclear computations. Through this foundational paper, we hope to make the windowed multipole representation accessible, reproducible, and usable for the nuclear physics community, as well as provide the theoretical basis for future research on expanding its capabilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Data Trend Shifts Induced by Method of Concentration for Trace Metals in Seawater: Automated Online Preconcentration vs Borohydride Reductive Coprecipitation of Nearshore Seawater Samples for Analysis of Ni, Cu, Zn, Cd, and Pb via ICP-MS

This research compares performance, reproducibility, and detection limits of ambient seawater analysis for trace metals using both borohydride reductive co-precipitation and an automated chelation column (seaFAST™ 2) co-preconcentration for matrix interferent elimination on total and dissolved grab samples in nearshore to marine waters, over a broad concentration range, prior to ICP-MS injection. A move to an online preconcentration method both minimizes sample preparation, and eliminates correction errors when accounting for trace impurities in precipitated samples, induced via reagents. The reproducability of the online preconcentration method described, coupled with low blanks and method detection limits (MDLs), demonstrates an effective move to an automated procedure using ethylenediaminetriacetic and iminodiacetate acid chelation exchange resin and multi-analyte determination via ICP-MS for total and dissolved Ni, Cu, Zn, Cd, and Pb in marine water samples. Average CASS-5 recoveries using the online preconcentration method (n=9) were 109±7%, 104±5%, 103±7%, 101±3%, and 86±8% respectively. The MDLs obtained from the automated method for Ni, Cu, Zn, Cd and Pb were 3.3, 1.8, 13.5, 4, and 10 times lower, respectively, than for the Borohydride method. There were statistically significant differences between the methods for CASS-5 recoveries of Ni, Cu, Zn (p < 0.0001), and Pb (p = 0.0024). Comparison of methods gave high concordance (rC = 0.90) between methods for total and dissolved Ni, Cu, Zn, and Pb, and total Cd.

seaFAST, borohydride, seawater, Ethylenediaminetet↗

Polymer derived Nicalon/Si-C-O composites - Processing and mechanical behavior

Ceramic matrix composites fabricated using Nicalon fiber and several polysilsesquioxane-derived Si-C-O matrices were characterized by optical and SEM and in four-point bending. In the matrix material linear shrinkages of up to 19 percent were observed for the vinylmethyl copolymer pyrolyzed to 1200 C, and up to 13 percent for the phenylmethyl material pyrolyzed to the same temperature, resulting in considerable matrix cracking. Under four-point loading, most composite samples fractured in a brittle manner as the result of strong fiber-matrix bonding. Flexural strengths, moduli, and ultimate strain varied with fiber sizing and processing parameters. Testing and analysis is being applied to promote more fibrous pullout during fracture.

Hurwitz, Frances I.↗

Proficiency Tests for Environmental Radioactivity Measurement Organized by an Accredited Laboratory

For 40 years, STEME (Environmental Sample Processing and Metrology Department) organized international proficiency testing (PT) exercises formerly for WHO (World Health Organization) and EC (European Community) and currently for ASN (French Nuclear Safety Authority). Five PT exercises are organized each year for the measurement of radionuclides (alpha, beta and gamma) in different matrixes (water, soil, biological and air samples) at environmental levels. ASN can deliver a French ministerial agreement to participate on environmental radioactivity measurements French network for laboratories asking it. Since 2006, November, STEME is the first French entity obtaining a COFRAC (French Committee of Accreditation) accreditation as 'Interlaboratory Comparisons' for the organization of proficiency tests for environmental radioactivity measurement according to standard International Standard Organization (ISO) 17025 and guide ISO 43-1. STEME has in charge to find, as far as possible, real sample or to create, by radionuclide adding, an adapted sample. STEME realizes the sampling, the samples preparation and the dispatching. STEME is also accredited according to Standard 17025 for radioactivity measurements in environmental samples and determines homogeneity, stability and reference values. After the reception of participating laboratories results, STEME executes statistical treatments in order to verify the normal distribution, to eliminate outliers and to evaluate laboratories performance.Laboratories participate with several objectives, to obtain French agreement, to prove the quality of their analytical performance in regards to standard 17025 or to validate new methods or latest developments. For 2 years, in addition to usual PT exercises, new PT about alpha or beta measurement in air filters, radioactive iodine in carbon cartridges or measurement of environmental dosimeters are organized. These PT exercises help laboratories to improve radioactive measurements and to rectify old mistakes. The PT exercises organized by STEME are becoming essential for French and some European laboratories working in radioactive measurements.The STEME organization, in respect of accreditation references, is presented.

54 ENVIRONMENTAL SCIENCES↗

UO 2 + 5 vol% ZrB 2 nano composite nuclear fuels with full boron retention and enhanced oxidation resistance

The boron isotope ( 10 B) can be used as a neutron absorber in UO 2 to control the reactivity of nuclear fuel pellets, however, the boron source can react with oxygen source in UO 2 to form B 2 O 3 that vaporize readily at temperatures above 1200 °C. Unfortunately, the sintering of UO 2 fuel requires hours holding at high temperature (>1700 °C), resulting in an inevitable B loss during sintering and unpredictable B concentration in final product. It is challenging to incorporate boron through a conventional sintering method. In this work, we demonstrated that spark plasma sintering (SPS), a field assisted sintering technology, can effectively densify UO 2 + 5 vol% ZrB 2 composite fuel pellets by rapid consolidation at 1600 °C for a short duration of 5 min under an applied pressure of 40 MPa. Further, thermogravimetric analysis (TGA) measurements confirm that ZrB 2 is fully retained inside the composite fuel pellets. Inside the composite fuel pellets, nano sized ZrB 2 particles are uniformly distributed along the grain boundaries of the UO 2 matrix. The ZrB 2 particle transforms to a glassy B 2 O 3 phase covering the sample surface and grain boundaries of UO 2 matrix after a simple post-sintering annealing at 1000 °C in flowing Argon gas for 4 h. The formed glassy B 2 O 3 slows down the diffusion of oxygen ions and postpones the onset temperature for oxidation of UO 2 from 400 °C to 550 °C. This study demonstrates the capability of SPS, an advanced fuel manufacturing technique, to achieve a full retention of ZrB 2 in UO 2 oxide fuel and increase oxidation resistance through a simple post-sintering annealing. The reported work holds great engineering potential for development of advanced oxide fuel for nuclear application.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Laser Ablation-Aerosol Mass Spectrometry-Chemical Ionization Mass Spectrometry for Ambient Surface Imaging

Mass spectrometry imaging is becoming an increasingly common analytical technique due to its ability to provide spatially resolved chemical information. In this paper, we report a novel imaging approach combining laser ablation with two mass spectrometric techniques, aerosol mass spectrometry and chemical ionization mass spectrometry, separately and in parallel. Both mass spectrometric methods provide the fast response, rapid data acquisition, low detection limits, and high-resolution peak separation desirable for imaging complex samples. Additionally, the two techniques provide complementary information with aerosol mass spectrometry providing near universal detection of all aerosol molecules and chemical ionization mass spectrometry with a heated inlet providing molecular-level detail of both gases and aerosols. The two techniques operate with atmospheric pressure interfaces and require no matrix addition for ionization, allowing for samples to be investigated in their native state under ambient pressure conditions. We demonstrate the ability of laser ablation-aerosol mass spectrometry-chemical ionization mass spectrometry (LA-AMS-CIMS) to create 2D images of both standard compounds and complex mixtures. Finally, the results suggest that LA-AMS-CIMS, particularly when combined with advanced data analysis methods, could have broad applications in mass spectrometry imaging applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structured estimation - Sample size reduction for adaptive pattern classification

The Gaussian two-category classification problem with known category mean value vectors and identical but unknown category covariance matrices is considered. The weight vector depends on the unknown common covariance matrix, so the procedure is to estimate the covariance matrix in order to obtain an estimate of the optimum weight vector. The measure of performance for the adapted classifier is the output signal-to-interference noise ratio (SIR). A simple approximation for the expected SIR is gained by using the general sample covariance matrix estimator; this performance is both signal and true covariance matrix independent. An approximation is also found for the expected SIR obtained by using a Toeplitz form covariance matrix estimator; this performance is found to be dependent on both the signal and the true covariance matrix.

Morgera, S.↗