Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Laser Sounder for Global Measurement of CO2 Concentrations in the Troposphere from Space: Progress

We describe progress toward developing a laser-based technique for the remote measurement of the tropospheric CO2 concentrations from orbit. Our goal is to demonstrate a lidar technique and instrument technology that will permit measurements of the CO2 column abundance in the lower troposphere from aircraft at the few ppm level, with a capability of scaling to permit global CO2 measurements from orbit. Accurate measurements of the tropospheric CO2 mixing ratio from space are challenging due to the many potential error sources. These include possible interference from other trace gas species, the effects of temperature, clouds, aerosols & turbulence in the path, changes in surface reflectivity, and variability in dry air density caused by changes in atmospheric pressure, water vapor and topographic height. Some potential instrumental errors include frequency drifts in the transmitter, small transmission and sensitivity drifts in the instrument. High signal-to-noise ratios and measurement stability are needed for mixing ratio estimates at the few ppm level. We have been developing a laser sounder approach as a candidate for a future space mission. It utilizes multiple different laser transmitters to permit simultaneous measurement of CO2 and O2 extinction, and aerosol backscatter in the same measurement path. It directs the narrow co-aligned laser beams from the instrument's fiber lasers toward nadir, and measures the energy of the strong laser echoes reflected from the Earth's land and water surfaces. During the measurement its narrow linewidth lasers are rapidly tuned on- and off- selected CO2 line near 1572 nm and an O2 absorption line near 770 nm. The receiver measures the energies of the laser echoes from the surface and any clouds and aerosols in the path with photon counting detectors. Ratioing the on- to off-line echo pulse energies for each gas permits the column extinction and column densities of CO2 and O2 to be estimated simultaneously via the differential absorption lidar technique. For the on-line wavelengths, the side of the selected absorption lines are used, which due to pressure broadening, weights the measurements to the lower troposphere, where CO2 variations caused by surface sources and sinks are largest. Simultaneous measurements of O2 column abundance are made using an identical approach using an O2 line. The laser backscatter profiles from clouds and aerosols are measured with other lidar channels, which permits identifying measurements influenced by clouds and/or aerosol scattering in the path. For space use, our lidar would continuously measure at nadir in near polar circular orbit. Using dawn and dusk measurements made over the same region will make it possible to sample the diurnal variations in CO2 mixing ratios. A 1-m diameter telescope is used for the receiver for all wavelengths. When averaging over 50 seconds, our calculations show a SNR of approximately 1500 is achievable for each gas at each on- and off-line measurement. Measurements from such a mission can be used to generate monthly global maps of the lower tropospheric CO2 column abundance. Our calculations show global coverage with an accuracy of a few ppm with a spatial resolution of approximately 50,000 sq. km are achievable each month. We have demonstrated some key elements of the laser, detector and receiver approaches in the laboratory and with measurements over a 206 m horizontal path. These include stable measurements of CO2 line shapes in an absorption cell using a fiber laser amplifier seeded by a tunable diode laser, measurement of small amplitude changes at low optical signal levels with the PMT receiver, and comparison of the horizontal path measurements of CO2 against those from an in-situ instrument.

Abshire, J. B.↗

EPCAPE-PT-LANL Measurements: Wideband Integrated Bioaerosol Sensor

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Wideband Integrated Bioaerosol Sensor (Droplet Measurements Technology) Data Notes: The WIBS is an online single-particle measurement that detects FBAPs (within a size range of 0.5 - 30 microns in diameter) based on the excitation and emission wavelengths of the individual particles. Using two xenon lamps, the WIBS excites FBAPs at 280 nm and 370 nm. Their emission is detected across two wavebands of 310-400 nm and 420-650 nm. We classified the FBAPs into seven different categories (A, B, C, AB, BC, AC, and ABC) using the classification scheme in Perring et. al. (2015) [1]. Averaged number concentration of FBAPs (total and by category) and particles that non-fluorescent bioaerosols particles (NFBAPs). In separate files, we also present one-minute-averaged size distributions and the asymmetry factor (AF, a surrogate for shape) of all FBAPs and NFBAPs. The logarithmic bin width of the size bins are the same as the average bin width of the AOS's optical particle counter (OPC, Grimm) for the range of sizes in which they overlap (26 bins from 0.5 - 30 microns). AF of the particles ranges from 0-100 and is divided into five bins with a linear spacing at increments of 20. The smallest AF bin represents more spherical particles while the largest bin represents more rod-shaped particles. [1] Perring, A. E., et al. (2015), Airborne observations of regional variation in fluorescent aerosol across the United States, J. Geophys. Res. Atmos., 120, 1153–1170, doi:10.1002/2014JD022495. Abstract and description of the campaign can be found here : https://www.arm.gov/research/campaigns/amf2023epcape-pt-lanl. Files data_10min_WIBS_AFDist.csv Header: - FBAP_AFDist[/cm3]_Bin_1 to Bin_5: Concentration of fluorescent bioaerosol particles in the each of 5 AF bins, measured in particles per cubic centimeter. Each bin represents a specific range of particle AF, capturing the shapes of FBAPs detected during the measurement. - NFBAP_AFDist[/cm3]_Bin_1 to Bin_5: Concentration of non-fluorescent bioaerosol particles in the each of 5 AF bins, measured in particles per cubic centimeter. Each bin represents a specific range of particle AF, capturing the shapes of NFBAPs detected during the measurement. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement. AF Bins: • Bin 1: 0 – 20 [unitless] • Bin 2: 21 – 40 [unitless] • Bin 3: 41 – 60 [unitless] • Bin 4: 61 – 80 [unitless] • Bin 5: 81 – 100 [unitless] Files data_10min_WIBS_Conc.csv Header: - NumberConcentrationA[/cm3]: Number concentration of bioaerosol particles detected by fluorescence channel A, measured in particles per cubic centimeter. - NumberConcentrationB[/cm3]: Number concentration of bioaerosol particles detected by fluorescence channel B, measured in particles per cubic centimeter. - NumberConcentrationC[/cm3]: Number concentration of bioaerosol particles detected by fluorescence channel C, measured in particles per cubic centimeter. - NumberConcentrationAB[/cm3]: Combined number concentration of bioaerosol particles detected by both fluorescence channels A and B, measured in particles per cubic centimeter. - NumberConcentrationBC[/cm3]: Combined number concentration of bioaerosol particles detected by both fluorescence channels B and C, measured in particles per cubic centimeter. - NumberConcentrationAC[/cm3]: Combined number concentration of bioaerosol particles detected by both fluorescence channels A and C, measured in particles per cubic centimeter. - NumberConcentrationABC[/cm3]: Combined number concentration of bioaerosol particles detected by all three fluorescence channels A, B, and C, measured in particles per cubic centimeter. - NumberConcentrationNFBAP[/cm3]: Number concentration of non-fluorescent bioaerosol particles, measured in particles per cubic centimeter. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement. Files data_10min_WIBS_SizeDist.csv Header: - FBAP_SizeDist[/cm3]_Bin_1 to FBAP_SizeDist[/cm3]_Bin_26: Number concentrations of FBAP in each of 26 size bins, measured in particles per cubic centimeter. Each bin represents a specific range of particle sizes, capturing the size distribution of FBAPs detected during the measurement. - NFBAP_SizeDist[/cm3]_Bin_1 to NFBAP_SizeDist[/cm3]_Bin_26: Number concentrations of NFBAP in each of 26 size bins, measured in particles per cubic centimeter. Similar to FBAP, each bin covers a specific range of particle sizes, detailing the size distribution of NFBAPs detected. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement. Size Bins: • Bin 1: 0.48 to 0.57 μm • Bin 2: 0.57 to 0.67 μm • Bin 3: 0.67 to 0.79 μm • Bin 4: 0.79 to 0.93 μm • Bin 5: 0.93 to 1.1 μm • Bin 6: 1.1 to 1.29 μm • Bin 7: 1.29 to 1.52 μm • Bin 8: 1.52 to 1.8 μm • Bin 9: 1.8 to 2.11 μm • Bin 10: 2.11 to 2.5 μm • Bin 11: 2.5 to 2.94 μm • Bin 12: 2.94 to 3.46 μm • Bin 13: 3.46 to 4.08 μm • Bin 14: 4.08 to 4.81 μm • Bin 15: 4.81 to 5.67 μm • Bin 16: 5.67 to 6.68 μm • Bin 17: 6.68 to 7.88 μm • Bin 18: 7.88 to 9.29 μm • Bin 19: 9.29 to 10.96 μm • Bin 20: 10.96 to 12.92 μm • Bin 21: 12.92 to 15.23 μm • Bin 22: 15.23 to 17.96 μm • Bin 23: 17.96 to 21.17 μm • Bin 24: 21.17 to 24.96 μm • Bin 25: 24.96 to 29.43 μm • Bin 26: 29.43 to 34.70 μm

54 ENVIRONMENTAL SCIENCES↗

Laser Sounder for Global Measurement of CO2 Concentrations in the Troposphere from Space

Measurements of tropospheric CO2 abundance with global-coverage, a few hundred km spatial and monthly temporal resolution are needed to quantify processes that regulate CO2 storage by the land and oceans. The Orbiting Carbon Observatory (OCO) is the first space mission focused on atmospheric CO2 for measuring total column CO, and O2 by detecting the spectral absorption in reflected sunlight. The OCO mission is an essential step, and will yield important new information about atmospheric CO2 distributions. However there are unavoidable limitations imposed by its measurement approach. These include best accuracy only during daytime at moderate to high sun angles, interference by cloud and aerosol scattering, and limited signal from CO2 variability in the lower tropospheric CO2 column. We have been developing a new laser-based technique for the remote measurement of the tropospheric CO2 concentrations from orbit. Our initial goal is to demonstrate a lidar technique and instrument technology that will permit measurements of the CO2 column abundance in the lower troposphere from aircraft. Our final goal is to develop a space instrument and mission approach for active measurements of the CO2 mixing ratio at the 1-2 ppmv level. Our technique is much less sensitive to cloud and atmospheric scattering conditions and would allow continuous measurements of CO2 mixing ratio in the lower troposphere from orbit over land and ocean surfaces during day and night. Our approach is to use the 1570nm CO2 band and a 3-channel laser absorption spectrometer (i.e. lidar used an altimeter mode), which continuously measures at nadir from a near polar circular orbit. The approach directs the narrow co-aligned laser beams from the instrument's lasers toward nadir, and measures the energy of the laser echoes reflected from land and water surfaces. It uses several tunable fiber laser transmitters which allowing measurement of the extinction from a single selected CO2 absorption line in the 1570 nm band. This band is free from interference from other gases and has temperature insensitive absorption lines. During the measurement the lasers are tuned on- and off- a selected CO2 line near 1572 nm and a selected O2 line near 768 nm in the Oxygen A band at kHz rates. The lasers use tunable diode seed lasers followed by fiber amplifiers, and have spectral widths much narrower than the gas absorption lines. The receiver uses a 1-m diameter telescope and photon counting detectors and measures the background light and energies of the laser echoes from the surface. The extinction and column densities for the CO2 and O2 gases are estimated from the ratio of the on and offline surface echo via the differential optical absorption technique. Our technique rapidly alternates between several on-line wavelengths set to the sides of the selected gas absorption lines. It exploits the atmospheric pressure broadening of the lines to weight the measurement sensitivity to the atmospheric column below 5 km. This maximizes sensitivity to CO2 in the boundary layer, where variations caused by surface sources and sinks are largest. Simultaneous measurements of O2 column will use an identical approach with an O2 line. Thee laser frequencies are tunable and have narrow (MHz) line widths. In combination with sensitive photon counting detectors these enables much higher spectral resolution and precision than is possible with passive spectrometer. 1aser backscatter profiles are also measured, which permits identifying measurements made to cloud tops and through aerosol layers. The measurement approach using lasers in common-nadir-zenith path allows retrieving CO2 column mixing ratios in the lower troposphere irrespective of sun angle. Pulsed laser signals, time gated receiver and a narrow receiver field-of-view are used to isolate the surface laser echo signals and to exclude photons scattered from clouds and aerosols. Nonetheless, the optical absorption change due to a change of a few ppO2 is small, <1 % which makes achieving the needed measurement sensitivities and stabilities quite challenging. Measurement SNRs and stabilities of >600:1 are needed to estimate CO2 mixing ratio at the 1-2 ppm level. We have calculated characteristics of the technique and have demonstrated aspects of the laser, detector and receiver approaches in th e laboratory We have also measured O2 in an absorption cell, and made C02 measurements over a 400 m long (one way) horizontal path using a sensor breadboard. We will describe these and more details of our approach in the paper.

Abshire, James B.↗

Assessment of Existing OpenStudio Measures: Reviews, Interviews, and Future Developments

OpenStudio Measure development is continuously in progress and greatly propelled by the collaborative efforts within the building energy modeling community. To ensure the widespread adoption and benefit of OpenStudio Measures, developers must understand the current status of Measure development and the needs of OpenStudio Measure users. The first step involves a comprehensive review of existing content to prevent redundancy and gain insights into how OpenStudio Measures are used in the building energy modeling community. This knowledge can then be integrated into the Measure development process, and the expertise of practitioners and OpenStudio Measure users can be leveraged to shape future Measures. Numerous OpenStudio Measures have been created and shared on the Building Component Library (BCL). The BCL is an open-source repository housing various OpenStudio-related resources, including building component blocks, descriptive metadata, and Measures describing modifications to building energy models. The OpenStudio Measures in BCL encompass a wide range of energy conservation Measures from basic lighting power reduction to complex HVAC model transformation. They also enable users to generate customized reports and facilitate the integration of energy simulation with other analytical processes. This report presents review of 272 currently available OpenStudio Measures in BCL. The OpenStudio Measures were reviewed by category and subcategory. These Measures are summarized by their functionalities and keywords. To gain insights into how OpenStudio Measures are used in building energy modeling community, interviews were conducted. A total of 12 interview responses were collected from 6 individuals in the industry and 6 individuals in academia. The knowledge acquired from reviewing the existing Measures and interview results will be integrated into the Measure development process, and the expertise of practitioners and OpenStudio Measure users will be leveraged to shape future Measures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measurement Uncertainty in One-Of-A-Kind Event Data Analysis

A golden standard in science is to repeat an experiment a statistically significant number of times, recording data using the same set of detectors and the same data analysis methodology. In such case experimental error includes both the range of true values generated by repetitions of the experiment, and measurement uncertainty caused by the detector. They are independent. It is a huge and too frequently used simplification, to assume that one can measure multiple repetitions of an identical experiment, resulting in identical true experimental value. Repetitions, as similar is it is experimentally achievable, have unavoidable built-in differences resulting in a range of the true values rather than in a single value. When modern, very sensitive and well calibrated measurement systems are used, this range is not negligible, and sometimes dominates over the measurement uncertainty. Range of true values depends on built-in differences in physics of the experiment. Stochastic physical processes result typically in a broader range of true values than non-stochastic processes do. Measurement uncertainty depends on a measurement method (properties of the detector not of the experiment). Modern measurement methods, including digital ones, frequently make the measurement uncertainty very small. When data from one–of –a kind experiment are analyzed, only the measurement uncertainty is reported. It provides no information about the range of true experimental values, neither about reliability of a reported data point. Reliability of a data point is in general independent from its measurement uncertainty. However, in practice reliable measurement methods frequently have high measurement uncertainty, while low reliability methods are applied to limit measurement uncertainty. Comparison of reliable data with high measurement uncertainty to not so reliable data measured with low uncertainty is discussed – in different scenarios different data analysis methods are applicable. Methods for data analysis from an experiment repeated statistically significant number of times are very well developed. They do not require a detailed expertise in physics of an experiment, nor in the properties of the measurement system used, and meaning of the reported uncertainty is well understood in any scientific community. It all changes when data from one-of-a-kind experiment is analyzed. Analyst’s expertise is required both in the physics of the experiment and in all aspects of the measurement system, all possible malfunctions. Data users must remember that only measurement uncertainty is reported from any one-of-a-kind experiment. Theory with simulations may provide estimation of expected built-in differences in the experiment, and by this of expected range of true values for a given experiment; yet measurement uncertainty can never be used in place of the range of true experimental values.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laboratory Radar Measurements in Support of the NASA Orbital Debris Program Office’s Size Estimation Model

The NASA Orbital Debris Program Office (ODPO) relies on ground-based radar measurements from both the Haystack Ultrawideband Satellite Imaging Radar (HUSIR) and the Goldstone Solar System Radar (Goldstone) to characterize mm to cm debris population in low Earth orbit (LEO). Radar measurements help characterize the size of orbital debris objects, particularly fragmentation debris. However, debris size is not directly measured by radar but inferred from the measured radar cross section (RCS) which depends on several parameters in addition to physical size including electrical conductivity and polarization. To interpret the observed RCS of orbital debris objects detected by radar measurements as physical sizes, NASA uses an empirical size estimation model (SEM) based on laboratory RCS measurements of breakup fragments generated during hypervelocity impact tests as well as some pieces of non-impact-generated “artificial” debris-like objects expected to be representative of the debris population. Since the development of the ODPO SEM, many new materials have been introduced to spacecraft construction. Consequently, ODPO plans to update the radar SEM based on planned laboratory RCS measurements of debris fragments from DebriSat, a ground-based hypervelocity impact experiment conducted in 2014 that consisted of a high-fidelity spacecraft model characteristic of a modern LEO spacecraft. Prior to measuring DebriSat fragments, a set of calibration targets with well-defined geometries and material compositions were measured at The Ohio State University’s ElectroScience Laboratory (OSU-ESL) compact radar range. These calibration measurements help to validate, and understand any limitations of, laboratory measurements of RCS. Calibration targets include idealizations of typical shape categories seen in DebriSat fragments such as nuggets, flat plates, and cylinders. As with DebriSat, calibration target materials were chosen to represent typical modern-day spacecraft components and include stainless steel, aluminum, printed circuit board (PCB) substrate, and carbon fiber-reinforced polymer (CFRP). These materials also represent a wide range of electrical conductivities, which strongly influences measured RCS and inferred target size. The RCS calibration measurements were collected over a frequency sweep from 2 to 18 GHz and stepping through different azimuth angles from 0 to 360 degrees at an elevation of 0 degrees. A second set of calibration measurements is in work consisting of more complex shapes such as bent rods and plates as well as different mounting options including epoxy and a 3D printed holder. These further measurements along with our initial calibration set will inform selection of representative DebriSat fragments for laboratory RCS measurements that will contribute to the planned update to the ODPO radar SEM. An appropriate subset of both the radar calibration and DebriSat samples will also be measured in the ODPO Optical Measurements Center to cross-calibrate size estimates over these different wavelength regimes.

Radar↗

Sensitivity Analysis of Situational Awareness Measures

A great deal of effort has been invested in attempts to define situational awareness, and subsequently to measure this construct. However, relatively less work has focused on the sensitivity of these measures to manipulations that affect the SA of the pilot. This investigation was designed to manipulate SA and examine the sensitivity of commonly used measures of SA. In this experiment, we tested the most commonly accepted measures of SA: SAGAT, objective performance measures, and SART, against different levels of SA manipulation to determine the sensitivity of such measures in the rotorcraft flight environment. SAGAT is a measure in which the simulation blanks in the middle of a trial and the pilot is asked specific, situation-relevant questions about the state of the aircraft or the objective of a particular maneuver. In this experiment, after the pilot responded verbally to several questions, the trial continued from the point frozen. SART is a post-trial questionnaire that asked for subjective SA ratings from the pilot at certain points in the previous flight. The objective performance measures included: contacts with hazards (power lines and towers) that impeded the flight path, lateral and vertical anticipation of these hazards, response time to detection of other air traffic, and response time until an aberrant fuel gauge was detected. An SA manipulation of the flight environment was chosen that undisputedly affects a pilot's SA-- visibility. Four variations of weather conditions (clear, light rain, haze, and fog) resulted in a different level of visibility for each trial. Pilot SA was measured by either SAGAT or the objective performance measures within each level of visibility. This enabled us to not only determine the sensitivity within a measure, but also between the measures. The SART questionnaire and the NASA-TLX, a measure of workload, were distributed after every trial. Using the newly developed rotorcraft part-task laboratory (RPTL) at NASA Ames Research Center, each pilot flew eight trials, four using SAGAT and four using performance measures. Each set of four trials differed by level of visibility as well. The flight paths were very similar in appearance and hazard number, allowing comparison between flight paths. The pilots were tasked with flying along a road at an assigned altitude and speed while avoiding any hazards that they happened upon. The attempt here was not to find a single best measure of SA, but rather to begin an investigation of the sensitivity of common measures of SA. Upon completion of this study, its results, in combination with future studies, should allow us to develop an empirically based taxonomy of SA measures and the contexts for their appropriate use.

Shively, R. J.↗

Conformance Testing: Measurement Decision Rules

The goal of a Quality Management System (QMS) as specified in ISO 9001 and AS9100 is to provide assurance to the customer that end products meet specifications. Measuring devices, often called measuring and test equipment (MTE), are used to provide the evidence of product conformity to specified requirements. Unfortunately, processes that employ MTE can become a weak link to the overall QMS if proper attention is not given to the measurement process design, capability, and implementation. Documented "decision rules" establish the requirements to ensure measurement processes provide the measurement data that supports the needs of the QMS. Measurement data are used to make the decisions that impact all areas of technology. Whether measurements support research, design, production, or maintenance, ensuring the data supports the decision is crucial. Measurement data quality can be critical to the resulting consequences of measurement-based decisions. Historically, most industries required simplistic, one-size-fits-all decision rules for measurements. One-size-fits-all rules in some cases are not rigorous enough to provide adequate measurement results, while in other cases are overly conservative and too costly to implement. Ideally, decision rules should be rigorous enough to match the criticality of the parameter being measured, while being flexible enough to be cost effective. The goal of a decision rule is to ensure that measurement processes provide data with a sufficient level of quality to support the decisions being made - no more, no less. This paper discusses the basic concepts of providing measurement-based evidence that end products meet specifications. Although relevant to all measurement-based conformance tests, the target audience is the MTE end-user, which is anyone using MTE other than calibration service providers. Topics include measurement fundamentals, the associated decision risks, verifying conformance to specifications, and basic measurement decisions rules.

Mimbs, Scott M.↗

Assessment of Thin Plastic Scintillation Detectors for Beta-Particle Measurements at the Advanced Test Reactor Critical Facility

The Fission Wire Measurement System is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical facility. The Advanced Test Reactor Critical facility is an open-pool, low-power test reactor used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in the Advanced Test Reactor. Power distribution measurements in ATR-C use uranium-aluminum wires that are distributed throughout the core to validate simulation and modeling results. These measurements require from 340 to 1500 wires to be irradiated and measured within a 12-hour window. The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. The gas flow detectors are of a custom design for this detector system that use methane gas with a large anode wire compared to modern proportional counters. These detectors, which are nearly 60 years old are irreplaceable. The measurements from these gas detectors are affected by the gas flow rate, atmospheric and line pressure, and are very sensitive to the applied high voltage. Recent improvements have been made to the control and data acquisition system, but the detectors have remained the same. The nature of the measurement of the fission product decay activity is such that the energy spectrum of the signal is changing with time. Thin, 250-um thick, plastic scintillators were commercially obtained as a potential replacement for the gas flow detectors. The original calibration of the uranium-aluminum fission wires was conducted in 1965 using a series of irradiations of gold foils and the wires in a well-characterized thermal neutron field. These measurements provided a time-dependent fission rate conversion factor from the gold foil data to calibrate the fission wires based on the response from the 2-pi proportional gas detectors. Transitioning to the new detectors requires qualification and testing. The sensitivity of the scintillators to changes in the energy spectrum of the fission wires and translation of the calibration factor have been completed. These measurements indicated that the sensitivity of the scintillators over time changes at a different rate than the sensitivity of the gas flow detectors. However, the inverse activity of measurements of both detector types is linear with time. Initial results indicate that the scintillator detectors will be a sufficient replacement for the gas detectors with minor adjustments to the fission rate conversion factor. Replacement of the detectors will improve the fission wire measurements and provide a more stable and reliable measurement system.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗