Search NASA⌕ Search

SEARCH · Search NASA

Results for “minimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

An Engineered Minimal-Set Stimulus for Periodic Information Leakage Fault Detection on a RISC-V Microprocessor

Recent evaluations of counter-based periodic testing strategies for fault detection in Microprocessor (μP) have shown that only a small set of counters is needed to provide complete coverage of severe faults. Severe faults are defined as faults that leak sensitive information, e.g., an encryption key on the output of a serial port. Alternatively, fault detection can be accomplished by executing instructions that periodically test the control and functional units of the μP. In this paper, we propose a fault detection method that utilizes an ’engineered’ executable program combined with a small set of strategically placed counters in pursuit of a hardware Periodic Built-In-Self-Test (PBIST). We analyze two distinct methods for generating such a binary; the first uses an Automatic Test Generation Pattern (ATPG)-based methodology, and the second uses a process whereby existing counter-based node-monitoring infrastructure is utilized. We show that complete fault coverage of all leakage faults is possible using relatively small binaries with low latency to fault detection and by utilizing only a few strategically placed counters in the μP.

42 ENGINEERING↗

Optimization of Conductive Fins to Minimize UO2 Fuel Temperature and Radial Temperature Gradient

To further the development of low-enriched uranium fuels, precedence has been placed on delivering the same amount of power while lowering the fuel temperature and radial temperature gradient. To address this, modeling efforts have resulted in a novel design featuring conductive fins of varying thermal conductivities and geometries inserted into the fuel matrix. These conductive inserts were not allowed to exceed 6% of the original fuel volume. This constraint was imposed due to other designs displacing 10% of fuel volume. A parametric study was performed that consisted of 2.56 million BISON simulations involving varying fin characteristics (i.e., fin thermal conductivity, number, and geometry) to determine the optimal geometric configuration for a desired amount of fuel volume displaced. The results from this study show that the thickness and length of each fin affect the fuel temperature and temperature gradient more than varying the number and thermal conductivity of the fins. The parametric study resulted in the development of an optimized combination to produce the lowest peak fuel temperature, lowest radial temperature gradient, and highest temperature reduction for the amount of original fuel volume displaced. The simulations presented in this work will eventually be compared with irradiation experiments of similar fuel designs at Idaho National Laboratory’s Advanced Test Reactor.

Paaren, Kyle M.↗

Noncured Graphene Thermal Interface Materials for High-Power Electronics: Minimizing the Thermal Contact Resistance

We report on experimental investigation of thermal contact resistance, RC, of the noncuring graphene thermal interface materials with the surfaces characterized by different degree of roughness, Sq. It is found that the thermal contact resistance depends on the graphene loading, ξ, non-monotonically, achieving its minimum at the loading fraction of ξ ~15 wt%. Decreasing the surface roughness by Sq~1 μm results in approximately the factor of ×2 decrease in the thermal contact resistance for this graphene loading. The obtained dependences of the thermal conductivity, KTIM, thermal contact resistance, RC, and the total thermal resistance of the thermal interface material layer on ξ and Sq can be utilized for optimization of the loading fraction of graphene for specific materials and roughness of the connecting surfaces. Our results are important for the thermal management of high-power-density electronics implemented with diamond and other wide-band-gap semiconductors.

36 MATERIALS SCIENCE↗

Novel Application of Hybrid Anion Exchange Resin for Phosphate Desorption Kinetics in Soils: Minimizing Re-Adsorption of Desorbed Ions

The process of phosphate desorption from soils is difficult to measure using stirred batch techniques because of the accumulation of desorbed ions in a bathing solution. To accurately measure the apparent rate coefficient of phosphate desorption from soils, it is necessary to remove the desorbed ions. In this study, a novel hybrid (i.e., iron oxide coated) anion exchange resin was used as a sink to study long-term (seven days) P desorption kinetics in intensively managed agricultural soils in the Midwestern U.S. (total phosphorus (TP): 196–419 mg/kg). The phosphate desorption kinetics in the hybrid anion exchange resin method were compared with those in the other conventional batch desorption method with pure anion exchange resins or without any sink. The extent of P desorption in the hybrid resin methods was >50% of total desorbed phosphate in the other methods. The initial kinetic rate estimated in the pseudo-second-order kinetic model was also highest (3.03–31.35 mg/(g·hr)) in the hybrid resin method when the same soil system was compared. This is because adsorbed P in the hybrid resins was nearly irreversible. The hybrid anion exchange resin might be a new and ideal sink in measuring the P desorption process in soils and sediments

54 ENVIRONMENTAL SCIENCES↗

A Scalable Approach to Minimize Charging Costs for Electric Bus Fleets

Incorporating battery electric buses into bus fleets faces three primary challenges: a BEB’s extended refuel time, the cost of charging, both by the consumer and the power provider, and large compute demands for planning methods. When BEBs charge, the additional demands on the grid may exceed hardware limitations, so power providers divide a consumer’s energy needs into separate meters even though doing so is expensive for both power providers and consumers. Prior work has developed a number of strategies for computing charge schedules for bus fleets; however, prior work has not worked to reduce costs by aggregating meters. Additionally, because many works use mixed integer linear programs, their compute needs make planning for commercial-sized bus fleets intractable. This work presents a multi-program approach to computing charge plans for electric bus fleets. The proposed method solves a series of subproblems where the solution to the charge problem becomes more refined with each problem, moving closer to the optimal schedule. The results demonstrate how runtimes are reduced by using intermediate subproblems to refine the bus charge solution so that the proposed method can be applied to large bus fleets of 100+ buses. Not only will we demonstrate that runtimes scale linearly with the number of buses but we will also show how the proposed method scales to large bus fleets of over 100 buses while managing the monthly cost of energy.

Mortensen, Daniel (ORCID:0000000276494452)↗

Device for residue handling minimization with vacuum-assisted separations

A device for collection of residue from separation columns. A manifold provides for multiple sample ports that are fluidly connected to a vacuum port by at least one channel. Residue from the separation columns is pulled through the sample ports, into the channel, and then to the vacuum port. From the vacuum port the residue can be moved, under the force of the vacuum, directly to a drain or to a collection vessel connected with a drain.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Jitter minimization flexure pointing system

The illustrative embodiments provide for a telescope. The telescope includes a housing; an optical assembly disposed inside the housing and configured to gather light from a distant object; and a jitter reduction system connected to the housing. The jitter reduction system includes a first flexure assembly comprising a first base to which is attached to a first armature connected to a first linear motor winding configured to push out a first flexure connected to the first armature and to push out a second flexure connected to the first armature opposite the first flexure, wherein the first flexure and the second flexure have a first normal axis pointing through a center of mass of the optical assembly.

42 ENGINEERING↗

OLED with minimal plasmonic losses

A top-emitting organic light emitting device (OLED) that comprises: a substrate having an inward side and an outward side; an OLED body that includes a transparent bottom electrode proximate to the inward side of the substrate, an organic emitting layer, and a transparent top electrode in that order; a non-metallic, diffuse reflective layer with a roughened top surface proximate to and facing the bottom transparent electrode; and a high refractive index waveguide layer. The diffuse reflective layer is positioned between the inward side of the substrate and the OLED body, and the waveguide layer is positioned between the diffuse layer and the bottom transparent electrode.

42 ENGINEERING↗

Energy-Efficient Forward Osmosis for FGD Wastewater Volume Minimization

A variant of forward osmosis, the Aquapod© process, was shown to be capable of concentrating FGDWW five-fold without the need for softening. The thermal and electrical energy consumption per unit of water produced was estimated to be 190 kJ/kg and ~2.2 kWh/m3, respectively. The FO process, in conjunction with a spray dryer, can achieve ZLD of 100 gpm of FGDWW with an estimated capital costs of $6.25 Million and a variable cost of $4.35/m3 of wastewater treated.

01 COAL, LIGNITE, AND PEAT↗

Lab Home Testing of Residential Isolation Space Control to Minimize Infectious Disease Transmission in Existing Single-Family Homes

Existing evidence strongly suggests that viral infectious diseases can be transmitted via an airborne route across distances in indoor environments. Accordingly, the risk of airborne transmission within homes should be managed. The public health emergency associated with SARS-CoV-2 makes controlling airborne transmission of respired viruses in indoor environments critical, especially in poorly ventilated indoor environments. The effectiveness of engineering interventions requiring minor efforts that create a negative-pressure isolation zone (IZ) for a contagious person has yet to be tested for existing residential homes. To mitigate the risk of airborne virus transmission and maximize health protection for the population in existing single-family homes, the relative effectiveness of several control strategies are investigated in this report. While very high-efficiency MERV filtration, high ventilation rates, and other controls can help be effective, most occupants are not likely to have the time or means for advanced measures found in hospitals. This project focused on testing relatively simple efforts that utilize existing or easy to acquire materials and simple processes.

30 DIRECT ENERGY CONVERSION↗

Method for removing a foulant from a gas stream with minimal external refrigeration

A process for removing a foulant from a gas stream. The gas stream is cooled in a series of heat exchangers, causing a portion of the foulant to desublimate and become entrained in a cryogenic liquid. This foulant slurry stream is pressurized, cooled, and separated into a pressurized foulant solid stream and the cryogenic liquid stream. The pressurized foulant solid stream is melted to produce a liquid foulant stream. Heat exchange processes, both internal and external, are provided that close the heat balance of the process. In this manner, the foulant is removed from the gas stream.

Baxter, Larry↗