Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear spectral function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Single-qubit lasing in the strong-coupling regime

Motivated by recent ''circuit QED'' experiments we study the lasing transition and spectral properties of single-qubit lasers. In the strong coupling, low-temperature regime, quantum fluctuations dominate over thermal noise and strongly influence the linewidth of the laser. When the qubit and the resonator are detuned, amplitude and phase fluctuations of the radiation field are coupled and the phase diffusion model, commonly used to describe conventional lasers, fails. We predict pronounced effects near the lasing transition, with an enhanced linewidth and nonexponential decay of the correlation functions. We cover a wide range of parameters by using two complementary approaches, one based on the Liouville equation in a Fock-state basis, covering arbitrarily strong coupling but limited to low photon numbers, the other based on the coherent-state representation, covering large photon numbers but restricted to weak or intermediate coupling.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An improved physics-based approach for unfolding megavoltage bremsstrahlung spectra using transmission analysis

Purpose: To develop a physics-based approach to improve the accuracy and robustness of the ill-conditioned problem of unfolding megavoltage bremsstrahlung spectra from transmission data. Methods: Spectra are specified using a rigorously-benchmarked functional form. Since ion chambers are the typical detector used in transmission measurements, the energy response of a Farmer chamber is calculated using the EGSnrc Monte Carlo code, and the effect of approximating the energy response on the accuracy of the unfolded spectra is studied. A proposal is introduced to enhance spectral sensitivity by combining transmission data measured with multiple detectors of different energy response and by combining data from multiple attenuating materials. Monte Carlo methods are developed to correct for nonideal exponential attenuation (e.g., scatter effects and secondary attenuation). The performance of the proposed methods is evaluated for a diverse set of validated clinical spectra (3.5-25 MV) using analytical transmission data with simulated experimental noise. Results: The approximations commonly used in previous studies for the ion-chamber energy response lead to significant errors in the unfolded spectra. Of the configurations studied, the one with best spectral sensitivity is to measure four full transmission curves using separate low-Z and high-Z attenuators in conjunction with two detectors of different energy response (the authors propose a Farmer-type ion chamber, once with a low-Z, and once with a high-Z buildup cap material), then to feed the data simultaneously to the unfolding algorithm. Deviations from ideal exponential attenuation are as much as 1.5% for the smallest transmission signals, and the proposed methods properly correct for those deviations. The transmission data with enhanced spectral sensitivity, combined with the accurate and flexible spectral functional form, lead to robust unfolding without requiring a priori knowledge of the spectrum. Compared with the commonly-used methods, the accuracy is improved for the unfolded spectra and for the unfolded mean incident electron kinetic energy by at least factors of three and four, respectively. With simulated experimental noise and a lowest transmission of 1%, the unfolded energy fluence spectra agree with the original spectra with a normalized root-mean-square deviation, %{Delta}({psi}), of 2.3%. The unfolded mean incident electron kinetic energies agree, on average, with the original values within 1.4%. A lowest transmission of only 10% still allows unfolding with %{Delta}({psi}) of 3.3%. Conclusions: In the presence of realistic experimental noise, the proposed approach significantly improves the accuracy and robustness of the spectral unfolding problem for all therapy and MV imaging beams of clinical interest.

61 RADIATION PROTECTION AND DOSIMETRY↗

Optimization of Thermal Neutron Converter in SiC Sensors for Spectral Radiation Measurements

Optimization of the neutron converter in SiC sensors is presented. The sensors are used for spectral radiation measurements of thermal and fast neutrons and optionally gamma ray at elevated temperature in harsh radiation environment. The neutron converter, which is based on 10B, allows to detect thermal neutrons by means of neutron capture reaction. Two construction of the sensors were used to measure radiation in experiments. Sensor responses collected in experiments have been reproduced by the computer tool created by authors, it allows to validate the tool. The tool creates the response matrix function describing the characteristic of the sensors and it was used for detailed analyses of the sensor responses. Obtained results help to optimize the neutron converter in order to increase thermal neutron detection. Several enhanced construction of the sensors, which includes the neutron converter based on {sup 10}B or {sup 6}Li, were proposed. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chaos on the hypercube

We analyze the spectral properties of a d-dimensional HyperCubic (HC) lattice model originally introduced by Parisi. The U(1) gauge links of this model give rise to a magnetic flux of constant magnitude φ but random orientation through the faces of the hypercube. The HC model, which also can be written as a model of 2d interacting Majorana fermions, has a spectral flow that is reminiscent of Maldacena-Qi (MQ) model, and its spectrum at φ = 0, actually coincides with the coupling term of the MQ model. As was already shown by Parisi, at leading order in 1/d, the spectral density of this model is given by the density function of the Q-Hermite polynomials, which is also the spectral density of the double-scaled Sachdev-Ye-Kitaev model. Parisi demonstrated this by mapping the moments of the HC model to Q-weighted sums on chord diagrams. We point out that the subleading moments of the HC model can also be mapped to weighted sums on chord diagrams, in a manner that descends from the leading moments. The HC model has a magnetic inversion symmetry that depends on both the magnitude and the orientation of the magnetic flux through the faces of the hypercube. The spectrum for fixed quantum number of this symmetry exhibits a transition from regular spectra at φ = 0 to chaotic spectra with spectral statistics given by the Gaussian Unitary Ensembles (GUE) for larger values of φ. For small magnetic flux, the ground state is gapped and is close to a Thermofield Double (TFD) state.

1/N expansion↗

Measurement of the ionization response of amorphous selenium with 122 keV γ rays

In this work, we performed a measurement of the ionization response of 200 μm-thick amorphous selenium (aSe) layers under drift electric fields of up to 50 V/μm. The aSe target was exposed to ionizing radiation from a 57 Co radioactive source and the ionization pulses were recorded with high resolution. Using the spectral line from the photoabsorption of 122 keV γ rays, we measured the charge yield in aSe and the line width as a function of drift electric field. From a detailed microphysics simulation of charge generation and recombination in aSe, we conclude that the strong dependence of recombination on the ionization track density provides the dominant contribution to the energy resolution in aSe. These results provide valuable input to estimate the sensitivity of a proposed next-generation search for the neutrinoless ββ decay of 82 Se that aims to employ imaging sensors with an active layer of aSe. We estimate the RMS line width of the integrated ionization signal from neutrinoless ββ decay events (of deposited energy 3 MeV) to be 2.0% for a drift field of 50 V/μm. The energy resolution can be improved to 1% by correcting for the charge yield as a function of ionization density along the imaged electron tracks.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterising local environments in high energy density Li-ion battery cathodes: a combined NMR and first principles study of LiFe x Co 1-x PO 4

Olivine-type LiCoPO4 (LCP) is a high energy density lithium ion battery cathode material due to the high voltage of the Co2+/Co3+ redox reaction. However, it displays a significantly poorer electrochemical performance than its more widely investigated isostructural analogue LiFePO4 (LFP). The co-substituted LiFexCo1-xPO4 olivines combine many of the positive attributes of each end member compound and are promising next-generation cathode materials. Here, the fully lithiated x = 0, 0.25, 0.5, 0.75 and 1 samples are extensively studied using 31P solid-state nuclear magnetic resonance (NMR). Practical approaches to broadband excitation and for the resolution of the isotropic resonances are described. First principles hybrid density functional calculations are performed on the Fermi contact shift (FCS) contributions of individual M–O–P pathways in the end members LFP and LCP and compared with the fitted values extracted from the LiFexCo1-xPO4 experimental data. Combining both data sets, the FCS for the range of local P environments expected in LiFexCo1-xPO4 have been calculated and used to assign the NMR spectra. Due to the additional unpaired electron in d6 Fe2+ as compared with d7 Co2+ (both high spin), LFP is expected to have larger Fermi contact shifts than LCP. However, two of the Co–O–P pathways in LCP give rise to noticeably larger shifts and the unexpected appearance of peaks outside the range delimited by the pure LFP and LCP 31P shifts. This behaviour contrasts with that observed previously in LiFexMn1-xPO4, where all 31P shifts lay within the LiMnPO4–LFP range. Although there are 24 distinct local P environments in LiFexCo1-xPO4, these group into seven resonances in the NMR spectra, due to significant overlap of the isotropic shifts. The local environments that give rise to the largest contributions to the spectral intensity are identified and used to simplify the assignment. This provides a tool for future studies of the electrochemically-cycled samples, which would otherwise be challenging to interpret.

36 MATERIALS SCIENCE↗

Determination of the argon spectral function from ( e , e ' p ) data

The E12-14-012 experiment, performed in Jefferson Lab Hall A, has measured the $(e, e'p)$ cross section in parallel kinematics using a natural argon target. Here, we report the full results of the analysis of the data set corresponding to beam energy 2.222 GeV, and spanning the missing momentum and missing energy range $15 \lesssim p_m \lesssim 300$ MeV/c and $12 \lesssim E_m \lesssim 80$ MeV. The reduced cross section, determined as a function of $p_m$ and $E_m$ with $\approx$4\% accuracy, has been fitted using the results of Monte Carlo simulations involving a model spectral function and including the effects of final state interactions. The overall agreement between data and simulations turns out to be quite satisfactory ($\chi^2$/n.d.o.f.=1.9). Furthermore, the resulting spectral function will provide valuable new information, needed for the interpretation of neutrino interactions in liquid argon detectors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Uncertainty and Sensitivity Analysis of TREAT Transient Test no. 15

The U.S. Department of Energy (DOE) is preparing for the resumption of transient testing using the Transient Reactor Test Facility (TREAT) located at the Idaho National Laboratory (INL). In order to support the analysis of TREAT operation and experiment planning, the MAMMOTH reactor physics team has recently begun development of uncertainty and sensitivity analysis for the TREAT core simulated via MAMMOTH. MAMMOTH is a high-fidelity three-dimensional transient multi-physics code developed at INL under the DOE-NE Advanced Modeling and Simulation program (NEAMS). This research is part of the development presenting some initial uncertainty and sensitivity analysis of TREAT Transient Test no. 15. In this summary, we employ the Sobol sampling strategy implemented in RAVEN to efficiently perform the sensitivity and uncertainty analysis. The idea is using Sobol functional decomposition with generalized polynomial chaos (gPC) expansions to estimate the responses of interest. The gPC coefficients are then computed via the sparse grid spectral projection method. In addition, this strategy includes evaluation of the second or higher order sensitivity indices, allowing the study of interactions between several input variables. The principal focus of this analysis is to quantify the uncertainties in the total power and maximum fuel temperatures with respect to uncertainties in the initial transient conditions, such as rated power, fuel temperature, graphite fuel density and control rod boron concentration. In addition, both the first order and second order time-dependent sensitivity indices are computed and analyzed. The results show that the interactions between initial control rod boron concentration and the rated power will contribute at most 1% to the total uncertainty of the power peak.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Anatomical background and generalized detectability in tomosynthesis and cone-beam CT

Purpose: Anatomical background presents a major impediment to detectability in 2D radiography as well as 3D tomosynthesis and cone-beam CT (CBCT). This article incorporates theoretical and experimental analysis of anatomical background ''noise'' in cascaded systems analysis of 2D and 3D imaging performance to yield ''generalized'' metrics of noise-equivalent quanta (NEQ) and detectability index as a function of the orbital extent of the (circular arc) source-detector orbit. Methods: A physical phantom was designed based on principles of fractal self-similarity to exhibit power-law spectral density ({kappa}/f{sup {beta}}) comparable to various anatomical sites (e.g., breast and lung). Background power spectra [S{sub B}(f)] were computed as a function of source-detector orbital extent, including tomosynthesis ({approx}10 deg. - 180 deg.) and CBCT (180 deg. +fan to 360 deg.) under two acquisition schemes: (1) Constant angular separation between projections (variable dose) and (2) constant total number of projections (constant dose). The resulting S{sub B} was incorporated in the generalized NEQ, and detectability index was computed from 3D cascaded systems analysis for a variety of imaging tasks. Results: The phantom yielded power-law spectra within the expected spatial frequency range, quantifying the dependence of clutter magnitude ({kappa}) and correlation ({beta}) with increasing tomosynthesis angle. Incorporation of S{sub B} in the 3D NEQ provided a useful framework for analyzing the tradeoffs among anatomical, quantum, and electronic noise with dose and orbital extent. Distinct implications are posed for breast and chest tomosynthesis imaging system design--applications varying significantly in {kappa} and {beta}, and imaging task and, therefore, in optimal selection of orbital extent, number of projections, and dose. For example, low-frequency tasks (e.g., soft-tissue masses or nodules) tend to benefit from larger orbital extent and more fully 3D tomographic imaging, whereas high-frequency tasks (e.g., microcalcifications) require careful, application-specific selection of orbital extent and number of projections to minimize negative effects of quantum and electronic noise. Conclusions: The complex tradeoffs among anatomical background, quantum noise, and electronic noise in projection imaging, tomosynthesis, and CBCT can be described by generalized cascaded systems analysis, providing a useful framework for system design and optimization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Far- and near-field optical properties of gold nanoparticle ensembles

The optical properties of gold nanoparticle clusters are presented from the point of view of their applications in biophotonics, where the absorption and scattering spectra are crucial. Generalised multiparticle Mie theory and finite difference time domain (FDTD) technique are used for theoretical description of the far- and nearfield optical properties of two dimensional nanoparticle ensembles. The system under consideration consists of spherical gold nanoparticles from 20 to 200 nm in diameter, forming 2D clusters in water. The properties of the far-field absorption and scattering spectra as a function of the cluster size, particle dimensions, and interparticle distance are investigated for ordered hexagonal structure of the particle arrays. It is found that the absorption efficiency can be shifted to the IR spectral range by increasing array size and decreasing interparticle distance. The increase in the array size also results in enhancement of the scattering efficiency while the absorption is reduced. The near-field intensity distribution is inhomogeneous over the array, as formation of zones with intensity enhancement of about two orders of magnitude is observed in specific areas. The optical properties of an ensemble whose configuration is reproduced from real experiments of gold nanoparticle deposition onto cancer cells are also presented. The results obtained can be used in designing of nanoparticle arrays with applications in biophotonics, bioimaging and photothermal therapy. (nanosystems)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Subwavenumber charge-coupled device spectrometer calibration using molecular iodine laser-induced fluorescence

Spectrometers configured with charge-coupled devices (CCD) or other array-based detectors require calibration to convert from the pixel coordinate to a spectral coordinate. A CCD calibration method well suited for Raman spectroscopy has been developed based on the 514.5 nm Ar{sup +} laser-induced fluorescence (LIF) spectrum of room-temperature molecular iodine vapor. Over 360 primary and secondary I{sub 2} LIF calibration lines spanning 510-645 nm were identified as calibrant peaks using an instrumental resolution of 1 cm{sup -1}. Two instrument calibration functions were evaluated with these peaks: a second-order polynomial and a function derived from simple optomechanical considerations. The latter function provided better fitting characteristics. Calibration using I{sub 2} LIF was tested with measurements of both laser light scattering and Raman spectra. The I{sub 2} LIF reference spectra and the signal spectra were recorded simultaneously, with no cross talk, by separating the two signals spatially along the vertical axis of the CCD imager. In this way, every CCD image could be independently calibrated. An accuracy and a precision of {+-}0.05 cm{sup -1} were achieved with this calibration technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear shape transitions in neutron-rich medium-mass nuclei

We study the isotopic evolution of the ground-state nuclear shapes in neutron-rich Kr, Rb, Sr, Y, Zr, Nb, and Mo isotopic chains. Both even-even and odd-A nuclei are included in the analysis. For the latter we also study the systematics of their one-quasiparticle low-lying configurations. The theoretical approach is based on a selfconsistent Hartree-Fock-Bogoliubov formalism with finite range Gogny energy density functionals. Neutron separation energies, charge radii, and the spin-parity of the ground states are calculated and compared with available data. Shape-transition signatures are identified around N= 60 isotones as discontinuities in both charge radii isotopic shifts and spin-parities of the ground states. The nuclear deformation including triaxiality is shown to play a relevant role in the understanding of the bulk and spectroscopic features of the ground and low-lying one-quasiparticle states.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improved spectral data unfolding for radiochromic film imaging spectroscopy of laser-accelerated proton beams

An improved method to unfold the space-resolved proton energy distribution function of laser-accelerated proton beams using a layered, radiochromic film (RCF) detector stack has been developed. The method takes into account the reduced RCF response near the Bragg peak due to a high linear energy transfer (LET). This LET dependence of the active RCF layer has been measured, and published data have been re-interpreted to find a nonlinear saturation scaling of the RCF response with stopping power. Accounting for the LET effect increased the integrated particle yield by 25% after data unfolding. An iterative, analytical, space-resolved deconvolution of the RCF response functions from the measured dose was developed that does not rely on fitting. After the particle number unfold, three-dimensional interpolation is performed to determine the spatial proton beam distribution for proton energies in-between the RCF data points. Here, image morphing has been implemented as a novel interpolation method that takes into account the energy-dependent, changing beam topology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Unexpected features in the optical vibrational spectra of δ-UO 3

Uranium trioxide displays a complex chemical phase space, with at least six structurally distinct polymorphs accessible via different synthetic routes. Remarkably, despite its technological importance, full structural and electronic characterization of these polymorphs remains an open area of study. δ-UO 3 in particular has attracted significant theoretical attention due to its high point group and space group symmetries, having U (VI) in octahedral coordination with polyhedra interconnected through corner-sharing to build a 3-D cubic lattice with space group symmetry Pm-3m and Z = 1. Critical experimental information, such as its optical vibrational spectra, are not known. Here, we study the Raman and infrared (IR) spectra of δ-UO 3 together with the support of density functional theory (DFT) calculations for spectral interpretation. A symmetry analysis of the DFT-predicted phonon eigenmodes indicates that δ-UO 3 should have two IR active modes and no Raman active modes. Experimental results, however, indicate significant Raman scattering from δ-UO 3 . We therefore propose four potential explanations for this apparent contradiction: a possible tetragonal distortion to the cubic cell, the existence of a surface impurity layer, vacancy scattering, and structural activation of Raman signal. We use powder X-ray diffraction and confocal Raman spectroscopy with depth profiling to investigate these possibilities and suggest future experiments to explore this phenomenon in more detail. Understanding the lattice dynamics of δ-UO 3 is important for identification of technogenic U phases via Raman and infrared spectroscopy and our results indicate that the simple understanding of δ-UO 3 as a high-symmetry cubic structure should be reconsidered.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Uncertainty and Sensitivity Analysis of TREAT Transient Test #15

The U.S. Department of Energy (DOE) is preparing for the resumption of transient testing using the Transient Reactor Test Facility (TREAT) located at the Idaho National Laboratory (INL). In order to support the analysis of TREAT operation and experiment planning, the MAMMOTH reactor physics team has recently begun development of uncertainty and sensitivity analysis for the TREAT core simulated via MAMMOTH. MAMMOTH is a high-fidelity three-dimensional transient multi-physics code developed at INL under the DOE-NE Advanced Modeling and Simulation program (NEAMS) [1]. This research is part of the development presenting some initial uncertainty and sensitivity analysis of TREAT Transient Test #15 [2]. In this summary, we employ the Sobol sampling strategy implemented in RAVEN [3] to efficiently perform the sensitivity and uncertainty analysis. The idea is using Sobol functional decomposition with generalized polynomial chaos (gPC) expansions to estimate the responses of interest [4]. The gPC coefficients are then computed via the spectral projection method with sparse grid approach. In addition, this strategy includes evaluation of the second or higher order sensitivity indices, allowing the study of interactions between several input variables. The principal focus of this analysis is to quantify the uncertainties in the total power and maximum fuel temperatures with respect to uncertainties in the initial transient conditions, such as rated power, fuel temperature, graphite fuel density and control rod boron concentration. In addition, both the first order and second order time-dependent sensitivity indices are computed and analyzed. The results show that the interactions between initial control rod boron concentration and the rated power will contribute at most 1% to the total uncertainty of the power peak.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Functionality and operation of fluoroscopic automatic brightness control/automatic dose rate control logic in modern cardiovascular and interventional angiography systems: A Report of Task Group 125 Radiography/Fluoroscopy Subcommittee, Imaging Physics Committee, Science Council

Task Group 125 (TG 125) was charged with investigating the functionality of fluoroscopic automatic dose rate and image quality control logic in modern angiographic systems, paying specific attention to the spectral shaping filters and variations in the selected radiologic imaging parameters. The task group was also charged with describing the operational aspects of the imaging equipment for the purpose of assisting the clinical medical physicist with clinical set-up and performance evaluation. Although there are clear distinctions between the fluoroscopic operation of an angiographic system and its acquisition modes (digital cine, digital angiography, digital subtraction angiography, etc.), the scope of this work was limited to the fluoroscopic operation of the systems studied. The use of spectral shaping filters in cardiovascular and interventional angiography equipment has been shown to reduce patient dose. If the imaging control algorithm were programmed to work in conjunction with the selected spectral filter, and if the generator parameters were optimized for the selected filter, then image quality could also be improved. Although assessment of image quality was not included as part of this report, it was recognized that for fluoroscopic imaging the parameters that influence radiation output, differential absorption, and patient dose are also the same parameters that influence image quality. Therefore, this report will utilize the terminology ''automatic dose rate and image quality'' (ADRIQ) when describing the control logic in modern interventional angiographic systems and, where relevant, will describe the influence of controlled parameters on the subsequent image quality. A total of 22 angiography units were investigated by the task group and of these one each was chosen as representative of the equipment manufactured by GE Healthcare, Philips Medical Systems, Shimadzu Medical USA, and Siemens Medical Systems. All equipment, for which measurement data were included in this report, was manufactured within the three year period from 2006 to 2008. Using polymethylmethacrylate (PMMA) plastic to simulate patient attenuation, each angiographic imaging system was evaluated by recording the following parameters: tube potential in units of kilovolts peak (kVp), tube current in units of milliamperes (mA), pulse width (PW) in units of milliseconds (ms), spectral filtration setting, and patient air kerma rate (PAKR) as a function of the attenuator thickness. Data were graphically plotted to reveal the manner in which the ADRIQ control logic responded to changes in object attenuation. There were similarities in the manner in which the ADRIQ control logic operated that allowed the four chosen devices to be divided into two groups, with two of the systems in each group. There were also unique approaches to the ADRIQ control logic that were associated with some of the systems, and these are described in the report. The evaluation revealed relevant information about the testing procedure and also about the manner in which different manufacturers approach the utilization of spectral filtration, pulsed fluoroscopy, and maximum PAKR limitation. This information should be particularly valuable to the clinical medical physicist charged with acceptance testing and performance evaluation of modern angiographic systems.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multispectral multidimensional spectrometer spanning the ultraviolet to the mid-infrared

Multidimensional spectroscopy is the optical analog to nuclear magnetic resonance, probing dynamical processes with ultrafast time resolution. At optical frequencies, the technical challenges of multidimensional spectroscopy have hindered its progress until recently, where advances in laser sources and pulse-shaping have removed many obstacles to its implementation. Multidimensional spectroscopy in the visible and infrared (IR) regimes has already enabled respective advances in our understanding of photosynthesis and the structural rearrangements of liquid water. A frontier of ultrafast spectroscopy is to extend and combine multidimensional techniques and frequency ranges, which have been largely restricted to operating in the distinct visible or IR regimes. By employing two independent amplifiers seeded by a single oscillator, it is straightforward to span a wide range of time scales (femtoseconds to seconds), all of which are often relevant to the most important energy conversion and catalysis problems in chemistry, physics, and materials science. Complex condensed phase systems have optical transitions spanning the ultraviolet (UV) to the IR and exhibit dynamics relevant to function on time scales of femtoseconds to seconds and beyond. We describe the development of the Multispectral Multidimensional Nonlinear Spectrometer (MMDS) to enable studies of dynamical processes in atomic, molecular, and material systems spanning femtoseconds to seconds, from the UV to the IR regimes. The MMDS employs pulse-shaping methods to provide an easy-to-use instrument with an unprecedented spectral range that enables unique combination spectroscopies. We demonstrate the multispectral capabilities of the MMDS on several model systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ab initio calculation of the potential bubble nucleus Si 34

Background: The possibility that an unconventional depletion (referred to as a “bubble”) happens in the middle of the charge density distribution of certain nuclei due to a purely quantum mechanical effect has attracted theoretical and experimental attention in recent years. Based on a mean-field rationale, a correlation between the occurrence of such a semibubble and an anomalously weak splitting between low angular-momentum spin-orbit partners has been further conjectured. Energy density functional and valence-space shell model calculations have been performed to identify and characterize the best candidates, among which Si 34 appears as a particularly interesting case. While the experimental determination of the charge density distribution of the unstable Si 34 is currently out of reach, ($d, p$) experiments on this nucleus have been performed recently to test the correlation between the presence of a bubble and an anomalously weak 1/2 – –3/2 – splitting in the spectrum of Si 35 as compared to S 37 . Purpose: We study the potential bubble structure of Si 34 on the basis of the state-of-the-art ab initio self-consistent Green's function many-body method. Methods: We perform the first ab initio calculations of Si 34 and S 36 . In addition to binding energies, the first observables of interest are the charge density distribution and the charge root-mean-square radius for which experimental data exist in S 36 . The next observable of interest is the low-lying spectroscopy of Si 35 and S 37 obtained from ($d, p$) experiments along with the spectroscopy of Al 33 and P 35 obtained from knock-out experiments. The interpretation in terms of the evolution of the underlying shell structure is also provided. The study is repeated using several chiral effective field theory Hamiltonians as a way to test the robustness of the results with respect to input internucleon interactions. The convergence of the results with respect to the truncation of the many-body expansion, i.e., with respect to the many-body correlations included in the calculation, is studied in detail. We eventually compare our predictions to state-of-the-art multireference energy density functional and shell model calculations. Results: The prediction regarding the (non)existence of the bubble structure in Si 34 varies significantly with the nuclear Hamiltonian used. Yet, demanding that the experimental charge density distribution and the root-mean-square radius of S 36 be well reproduced, along with Si 34 and S 36 binding energies, only leaves the NNLO sat Hamiltonian as a serious candidate to perform this prediction. In this context, a bubble structure, whose fingerprint should be visible in an electron scattering experiment of Si 34 , is predicted. Furthermore, a clear correlation is established between the occurrence of the bubble structure and the weakening of the 1/2 – –3/2 – splitting in the spectrum of Si 35 as compared to S 37 . Conclusions: The occurrence of a bubble structure in the charge distribution of Si 34 is convincingly established on the basis of state-of-the-art ab initio calculations. This prediction will have to be reexamined in the future when improved chiral nuclear Hamiltonians are constructed. On the experimental side, present results act as a strong motivation to measure the charge density distribution of Si 34 in future electron scattering experiments on unstable nuclei. In the meantime, it is of interest to perform one-neutron removal on Si 34 and S 36 in order to further test our theoretical spectral strength distributions over a wide energy range.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗