Search NASA⌕ Search

SEARCH · Search NASA

Results for “parameter optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Instrument performance study on the short and long pulse options of the second Spallation Neutron Source target station

The Spallation Neutron Source (SNS) facility at the Oak Ridge National Laboratory is designed with an upgrade option for a future low repetition rate, long wavelength second target station. This second target station is intended to complement the scientific capabilities of the 1.4 MW, 60 Hz high power first target station. Two upgrade possibilities have been considered, the short and the long pulse options. In the short pulse mode, proton extraction occurs after the pulse compression in the accumulator ring. The proton pulse structure is thus the same as that for the first target station with a pulse width of ∼0.7 μs. In the long pulse mode, protons are extracted as they are produced by the linac, with no compression in the accumulator ring. The time width of the uncompressed proton pulse is ∼1 ms. This difference in proton pulse structure means that neutron pulses will also be different. Neutron scattering instruments thus have to be designed and optimized very differently for these two source options which will directly impact the overall scientific capabilities of the SNS facility. In order to assess the merits of the short and long pulse target stations, we investigated a representative suit of neutron scattering instruments and evaluated their performance under each option. Our results indicate that the short pulse option will offer significantly better performance for the instruments and is the preferred choice for the SNS facility.

43 PARTICLE ACCELERATORS↗

Cobalt-60 tomotherapy: Clinical treatment planning and phantom dose delivery studies

Purpose: Investigations have shown that a Cobalt-60 (Co-60) radioactive source has the potential to play a role in intensity modulated radiation therapy (IMRT). In this paper, Co-60 tomotherapy's conformal dose delivery potential is evaluated by delivering conformal dose plans on a cylindrical homogeneous phantom containing clinical structures similar to those found in a typical head and neck (H and N) cancer. Also, the clinical potential of Co-60 tomotherapy is investigated by generating 2D clinical treatment plans for H and N and prostate anatomical regions. These plans are compared with the 6 MV based treatment plans for modalities such as linear accelerator-based tomotherapy and broad beam IMRT, and 15 MV based 3D conformal radiation therapy (3DCRT).Methods: For experimental validation studies, clinical and nonclinical conformal dose patterns were delivered on circular, homogeneous phantoms containing GafChromic film. For clinical planning study, dose calculations were performed with the EGSnrc Monte Carlo program, where a Theratronics 780C Co-60 unit and a 6 MV linear accelerator were modeled with a MIMiC binary multileaf collimator. An inhouse inverse treatment planning system was used to optimize tomotherapy plans using the same optimization parameters for both Co-60 and 6 MV beams. The IMRT and 3DCRT plans for the clinical cases were generated entirely in the Eclipse treatment planning system based on inhouse IMRT and 3DCRT site specific protocols.Results: The doses delivered to the homogeneous phantoms agreed with the calculations, indicating that it is possible to deliver highly conformal doses with the Co-60 unit. The dose distributions for Co-60 tomotherapy clinical plans for both clinical cases were similar to those obtained with 6 MV based tomotherapy and IMRT, and much more conformal compared to 3DCRT plans. The dose area histograms showed that the Co-60 plans achieve the dose objectives for the targets and organs at risk.Conclusions: These results confirm that Co-60 tomotherapy is capable of providing state-of-the-art conformal dose delivery and could be used for the treatment of targets in both small and larger separation anatomical regions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Poster — Thur Eve — 19: Performance assessment of a 160-leaf beam collimation system

In this study, the performance of the new beam collimation system with 160 leaves, each with a 5 mm leaf width projected at isocenter, is evaluated in terms of positional accuracy and plan/delivery quality. Positional accuracy was evaluated using a set of static and dynamic MLC/jaw delivery patterns at different gantry angles, dose rates, and MLC/jaw speeds. The impact on IMRT plan quality was assessed by comparing against a previous generation collimation system using the same optimization parameters, while delivery quality was quantified using a combination of patient-specific QA measurements with ion chambers, film, and a bi-planar diode array. Positional accuracy for four separate units was comparable. The field size accuracy, junction width, and total displacement over 16 cm leaf travel are 0.3 ± 0.2 mm, 0.4 ± 0.3 mm, and 0.5 ± 0.2 mm, respectively. The typical leaf minor offset is 0.05 ± 0.04 mm, and MLC hysteresis effects are 0.2 ± 0.1 mm over 16 cm travel. The dynamic output is linear with MU and MLC/jaw speed, and is within 0.7 ± 0.3 % of the planning system value. Plan quality is significantly improved both in terms of target coverage and OAR sparing due, in part, to the larger allowable MLC and jaw speeds. γ-index pass rates for the patient-specific QA measurements exceeded 97% using criteria of 2%/2 mm. In conclusion, the performance of the Agility system is consistent among four separate installations, and is superior to its previous generations of collimation systems.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-610: Comparison of Treatment Times Between the MLCi and Agility Multileaf Collimators

Purpose: The Agility is a new 160-leaf MLC developed by Elekta for use in their Infinity and Versa HD linacs. As compared to the MLCi, the Agility increased the maximum leaf speed from 2 cm/s to 3.5 cm/s, and the maximum primary collimator speed from 1.5 cm/s to 9.0 cm/s. The purpose of this study was to determine if the Agility MLC resulted in improved plan quality and/or shorter treatment times. Methods: An Elekta Infinity that was originally equipped with a 80 leaf MLCi was upgraded to an 160 leaf Agility. Treatment plan quality was evaluated using the Pinnacle planning system with SmartArc. Optimization was performed once for the MLCi and once for the Agility beam models using the same optimization parameters and the same number of iterations. Patient treatment times were measured for all IMRT, VMAT, and SBRT patients treated on the Infinity with the MLCi and Agility MLCs. Treatment times were extracted from the EMR and measured from when the patient first walked into the treatment room until exiting the treatment room. Results: 11,380 delivery times were measured for patients treated with the MLCi, and 1,827 measurements have been made for the Agility MLC. The average treatment times were 19.1 minutes for the MLCi and 20.8 minutes for the Agility. Using a t-test analysis, there was no difference between the two groups (t = 0.22). The dose differences between patients planned with the MLCi and the Agility MLC were minimal. For example, the dose difference for the PTV, GTV, and cord for a head and neck patient planned using Pinnacle were effectively equivalent. However, the dose to the parotid glands was slightly worse with the Agility MLC. Conclusion: There was no statistical difference in treatment time, or any significant dosimetric difference between the Agility MLC and the MLCi.

60 APPLIED LIFE SCIENCES↗

PET optimization for improved assessment and accurate quantification of {sup 90}Y-microsphere biodistribution after radioembolization

Purpose: {sup 90}Y-microspheres are widely used for the radioembolization of metastatic liver cancer or hepatocellular carcinoma and there is a growing interest for imaging {sup 90}Y-microspheres with PET. The aim of this study is to evaluate the performance of a current generation PET/CT scanner for {sup 90}Y imaging and to optimize the PET protocol to improve the assessment and the quantification of {sup 90}Y-microsphere biodistribution after radioembolization. Methods: Data were acquired on a Biograph mCT-TrueV scanner with time of flight (TOF) and point spread function (PSF) modeling. Spatial resolution was measured with a{sup 90}Y point source. Sensitivity was evaluated using the NEMA 70 cm line source filled with {sup 90}Y. To evaluate the count rate performance, {sup 90}Y vials with activity ranging from 3.64 to 0.035 GBq were measured in the center of the field of view (CFOV). The energy spectrum was evaluated. Image quality with different reconstructions was studied using the Jaszczak phantom containing six hollow spheres (diameters: 31.3, 28.1, 21.8, 16.1, 13.3, and 10.5 mm), filled with a 207 kBq/ml {sup 90}Y concentration and a 5:1 sphere-to-background ratio. Acquisition time was adjusted to simulate the quality of a realistic clinical PET acquisition of a patient treated with SIR-Spheres{sup ®}. The developed methodology was applied to ten patients after SIR-Spheres{sup ®} treatment acquiring a 10 min per bed PET. Results: The energy spectrum showed the{sup 90}Y bremsstrahlung radiation. The {sup 90}Y transverse resolution, with filtered backprojection reconstruction, was 4.5 mm in the CFOV and degraded to 5.0 mm at 10 cm off-axis. {sup 90}Y absolute sensitivity was 0.40 kcps/MBq in the center of the field of view. Tendency of true and random rates as a function of the {sup 90}Y activity could be accurately described using linear and quadratic models, respectively. Phantom studies demonstrated that, due to low count statistics in {sup 90}Y PET acquisition, the optimal parameters for the standard OSEM+PSF reconstruction were only one iteration and a postreconstruction filter of 6 mm FWHM, for both TOF and non-TOF reconstructions. Moreover, when TOF is included, the signal to noise ratio increased and visibility achieved 100% by the experienced observers and 93.3% according to the Rose model of statistical detection. In 50% of patients, TOF allowed the visualization of {sup 90}Y radioembolized lesions not seen without TOF, confirming phantom results. Liver activity was accurately quantified, with no significant differences between reconstructed and actual delivered activity to the whole-liver [mean relative difference (10.2 ± 14.7)%]. Conclusions: Qualitative and quantitative{sup 90}Y PET imaging improved with the introduction of TOF in a PET/CT scanner, thereby allowing the visualization of microsphere deposition in lesions not visible in non-TOF images. This technique accurately quantifies the total activity delivered to the liver during radioembolization with {sup 90}Y-microspheres and allows dose estimation.

60 APPLIED LIFE SCIENCES↗

A class solution for volumetric-modulated arc therapy planning in postprostatectomy radiotherapy

This study is aimed to test a postprostatectomy volumetric-modulated arc therapy (VMAT) planning class solution. The solution applies to both the progressive resolution optimizer algorithm version 2 (PRO 2) and the algorithm version 3 (PRO 3), addressing the effect of an upgraded algorithm. A total of 10 radical postprostatectomy patients received 68 Gy to 95% of the planning target volume (PTV), which was planned using VMAT. Each case followed a set of planning instructions; including contouring, field setup, and predetermined optimization parameters. Each case was run through both algorithms only once, with no user interaction. Results were averaged and compared against Radiation Therapy Oncology Group (RTOG) 0534 end points. In addition, the clinical target volume (CTV) D{sub 100}, PTV D{sub 99}, and PTV mean doses were recorded, along with conformity indices (CIs) (95% and 98%) and the homogeneity index. All cases satisfied PTV D{sub 95} of 68 Gy and a maximum dose < 74.8 Gy. The average result for the PTV D{sub 99} was 64.1 Gy for PRO 2 and 62.1 Gy for PRO 3. The average PTV mean dose for PRO 2 was 71.4 Gy and 71.5 Gy for PRO 3. The CTV D{sub 100} average dose was 67.7 and 68.0 Gy for PRO 2 and PRO 3, respectively. The mean homogeneity index for both algorithms was 0.08. The average 95% CI was 1.17 for PRO 2 and 1.19 for PRO 3. For 98%, the average results were 1.08 and 1.12 for PRO 2 and PRO 3, respectively. All cases for each algorithm met the RTOG organs at risk dose constraints. A successful class solution has been established for prostate bed VMAT radiotherapy regardless of the algorithm used.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-580: Comparison of Cervical Carcinoma IMRT Plans From Four Commercial Treatment Planning Systems (TPS)

Purpose: Different treatment planning systems (TPS) use different treatment optimization and leaf sequencing algorithms. This work compares cervical carcinoma IMRT plans optimized with four commercial TPSs to investigate the plan quality in terms of target conformity and delivery efficiency. Methods: Five cervical carcinoma cases were planned with the Corvus, Monaco, Pinnacle and Xio TPSs by experienced planners using appropriate optimization parameters and dose constraints to meet the clinical acceptance criteria. Plans were normalized for at least 95% of PTV to receive the prescription dose (Dp). Dose-volume histograms and isodose distributions were compared. Other quantities such as Dmin(the minimum dose received by 99% of GTV/PTV), Dmax(the maximum dose received by 1% of GTV/PTV), D100, D95, D90, V110%, V105%, V100% (the volume of GTV/PTV receiving 110%, 105%, 100% of Dp), conformity index(CI), homogeneity index (HI), the volume of receiving 40Gy and 50 Gy to rectum (V40,V50) ; the volume of receiving 30Gy and 50 Gy to bladder (V30,V50) were evaluated. Total segments and MUs were also compared. Results: While all plans meet target dose specifications and normal tissue constraints, the maximum GTVCI of Pinnacle plans was up to 0.74 and the minimum of Corvus plans was only 0.21, these four TPSs PTVCI had significant difference. The GTVHI and PTVHI of Pinnacle plans are all very low and show a very good dose distribution. Corvus plans received the higer dose of normal tissue. The Monaco plans require significantly less segments and MUs to deliver than the other plans. Conclusion: To deliver on a Varian linear-accelerator, the Pinnacle plans show a very good dose distribution. Corvus plans received the higer dose of normal tissue. The Monaco plans have faster beam delivery.

60 APPLIED LIFE SCIENCES↗

Feasibility of using intermediate x-ray energies for highly conformal extracranial radiotherapy

Purpose: To investigate the feasibility of using intermediate energy 2 MV x-rays for extracranial robotic intensity modulated radiation therapy. Methods: Two megavolts flattening filter free x-rays were simulated using the Monte Carlo code MCNP (v4c). A convolution/superposition dose calculation program was tuned to match the Monte Carlo calculation. The modeled 2 MV x-rays and actual 6 MV flattened x-rays from existing Varian Linacs were used in integrated beam orientation and fluence optimization for a head and neck, a liver, a lung, and a partial breast treatment. A column generation algorithm was used for the intensity modulation and beam orientation optimization. Identical optimization parameters were applied in three different planning modes for each site: 2, 6 MV, and dual energy 2/6 MV. Results: Excellent agreement was observed between the convolution/superposition and the Monte Carlo calculated percent depth dose profiles. For the patient plans, overall, the 2/6 MV x-ray plans had the best dosimetry followed by 2 MV only and 6 MV only plans. Between the two single energy plans, the PTV coverage was equivalent but 2 MV x-rays improved organs-at-risk sparing. For the head and neck case, the 2MV plan reduced lips, mandible, tongue, oral cavity, brain, larynx, left and right parotid gland mean doses by 14%, 8%, 4%, 14%, 24%, 6%, 30% and 16%, respectively. For the liver case, the 2 MV plan reduced the liver and body mean doses by 17% and 18%, respectively. For the lung case, lung V20, V10, and V5 were reduced by 13%, 25%, and 30%, respectively. V10 of heart with 2 MV plan was reduced by 59%. For the partial breast treatment, the 2 MV plan reduced the mean dose to the ipsilateral and contralateral lungs by 27% and 47%, respectively. The mean body dose was reduced by 16%. Conclusions: The authors showed the feasibility of using flattening filter free 2 MV x-rays for extracranial treatments as evidenced by equivalent or superior dosimetry compared to 6 MV plans using the same inverse noncoplanar intensity modulated planning method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A fixed-jaw method to protect critical organs during intensity-modulated radiotherapy

Intensity-modulated radiotherapy (IMRT) plays an important role in cancer radiotherapy. For some patients being treated with IMRT, the extremely low tolerances of critical organs (such as lens, ovaries, and testicles) cannot be met during treatment planning. The aim of this article is to introduce a new planning method to overcome that problem. In current planning practice, jaw positions are automatically set to cover all target volumes by the planning system (e.g., Pinnacle{sup 3} system). Because of such settings, critical organs may be fully blocked by the multileaf collimator (MLC), but they still sit in the field that is shaped by collimator jaws. These critical organs receive doses from the transmission and leakage of MLC leaves. We manually fixed jaw positions to block them to further reduce such doses. This method has been used for different treatment sites in our clinic, and it was thoroughly evaluated in patients with radical hysterectomy plus ovarian transposition after surgery. For each patient, 2 treatment plans were designed with the same optimization parameters: the original plan with automatically chosen jaw positions (called O-plan) and the plan with fixed-jaw positions (named F-plan). In the F-plan, the jaws were manually fixed to block the ovaries. For target coverage, the mean conformity index (CI) of the F-plan (1.28 ± 0.02) was remarkably lower than that of the O-plan (1.53 ± 0.09) (p < 0.05). The F-plan and the O-plan performed similarly in target dose homogeneity. Meanwhile, for the critical organ sparing, the mean dose of both ovaries were much lower in the F-plan than that in the O-plan (p < 0.05). The V{sub 20}, V{sub 30}, and V{sub 40} of bladder were also lower in the F-plan (93.57 ± 1.98, 73.99 ± 5.76, and 42.33 ± 3.7, respectively) than those in the O-plan (97.98 ± 1.11, 85.07 ± 4.04, and 49.71 ± 3.63, respectively) (p < 0.05). The maximum dose to the spinal cord planning organ at risk (OAR) volume (PRV) in the O-plan (3940.24 ± 102.8) was higher than that in the F-plan (3628.18 ± 131.45) with significant differences (p < 0.01). For other OARs, there were no significant differences in doses between these 2 plans except that the high-dose regions of the rectum were higher for V{sub 40} in the O-plan than that in the F-plan (p < 0.01). But the monitor units (MUs) in the F-plan were 1.4 times as much as that in the O-plan. Thus the treatment time could be longer by using the F-plan. As it results in more MUs in spite of better plan quality, it is recommended to be used only in situations in which clinical requirements to critical organs cannot be met with the regular method.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sequential ensemble-based optimal design for parameter estimation

The ensemble Kalman filter (EnKF) has been widely used in parameter estimation for hydrological models. The focus of most previous studies was to develop more efficient analysis (estimation) algorithms. On the other hand, it is intuitively understandable that a well-designed sampling (data-collection) strategy should provide more informative measurements and subsequently improve the parameter estimation. In this work, a Sequential Ensemble-based Optimal Design (SEOD) method, coupled with EnKF, information theory and sequential optimal design, is proposed to improve the performance of parameter estimation. Based on the first-order and second-order statistics, different information metrics including the Shannon entropy difference (SD), degrees of freedom for signal (DFS) and relative entropy (RE) are used to design the optimal sampling strategy, respectively. The effectiveness of the proposed method is illustrated by synthetic one-dimensional and two-dimensional unsaturated flow case studies. It is shown that the designed sampling strategies can provide more accurate parameter estimation and state prediction compared with conventional sampling strategies. Optimal sampling designs based on various information metrics perform similarly in our cases. Furthermore, the effect of ensemble size on the optimal design is also investigated. Overall, larger ensemble size improves the parameter estimation and convergence of optimal sampling strategy. Although the proposed method is applied to unsaturated flow problems in this study, it can be equally applied in any other hydrological problems.

54 ENVIRONMENTAL SCIENCES↗

Exploring the Structural, Dynamic, and Functional Properties of Metal–Organic Frameworks through Molecular Modeling

This review spotlights the role of atomic-level modeling in research on metal-organic frameworks (MOFs), especially the key methodologies of density functional theory (DFT), Monte Carlo (MC) simulations, and molecular dynamics (MD) simulations. The discussion focuses on how periodic and cluster-based DFT calculations can provide novel insights into MOF properties, with a focus on predicting structural transformations, understanding thermodynamic properties and catalysis, and providing information or properties that are fed into classical simulations such as force field parameters or partial charges. Classical simulation methods, highlighting force field selection, databases of MOFs for high-throughput screening, and the synergistic nature of MC and MD simulations, are described. By predicting equilibrium thermodynamic and dynamic properties, these methods offer a wide perspective on MOF behavior and mechanisms. Additionally, the incorporation of machine learning (ML) techniques into quantum and classical simulations is discussed. These methods can enhance accuracy, expedite simulation setup, reduce computational costs, as well as predict key parameters, optimize geometries, and estimate MOF stability. By charting the growth and promise of computational research in the MOF field, the aim is to provide insights and recommendations to facilitate the incorporation of computational modeling more broadly into MOF research.

36 MATERIALS SCIENCE↗

Elucidating the Structure of the Eu‐EDTA Complex in Solution at Various Protonation States

Abstract Ethylenediaminetetraacetic acid (EDTA), which has two amine and four carboxylate protonation sites, forms stable complexes with lanthanide ions. This work analyzes the coordination structure, in atomic resolution, of the Eu 3+ ion complexed with EDTA in all its protonation states in aqueous solution. Eu‐EDTA complexes were modeled using classical molecular dynamics (MD) simulations using force field parameters optimized with ab initio molecular dynamics (AIMD) simulations. Structures from the MD simulations were used to predict extended X‐ray absorption fine structure (EXAFS) spectra and compared with EXAFS measurements of the Eu 3+ aqua ion and Eu‐EDTA complexes at pH 3 and 11. This work details how Eu‐EDTA complex coordination structures change with increasing protonation of the EDTA ligand in the complex, from the tightly bound unprotonated complex to the unbinding of the fully protonated EDTA ligand from the Eu 3+ ion as both become solvated by water. Agreement between predicted and measured EXAFS spectra supports the findings from simulation.

Chemistry↗

Laser ablation of polymers: a review

Laser ablation (LA), which employs a pulsed laser to remove materials from a substrate for generating micro-/nanostructures, has tremendous applications in the fabrication of metals, ceramics, glasses and polymers. It has become a noteworthy approach for achieving various functional structures in engineering, chemistry, biology, medicine and other fields. Polymers are one such class of materials; they can be melted and vaporized at high temperature during the ablation process. A number of polymers have been researched as candidate substrates in LA, and many different structures and patterns have been realized by this method. The current states of research and progress are reviewed from basic concepts to optimal parameters, polymer types and applications. Additionally, the significance of this paper is to provide a basis for follow-up research that leads to the development of superior materials and high-quality production through LA. In this review, we first introduce the basic concept of LA, including mechanism, laser types (millisecond, microsecond, nanosecond, picosecond and femtosecond) and influential parameters (wavelength, repetition rate, fluence and pulse duration). Then, we focus on several commonly used polymer materials and compare them in detail, including the effects of polymer properties, laser parameters and feature designs. Finally, we summarize the applications of various structures fabricated by LA in a variety of areas along with a perspective of the challenges in this research area. Overall, a thorough review of LA of several polymers is presented, which could pave the way for characterization of future novel materials.

36 MATERIALS SCIENCE↗

Automated Integration of Continental-Scale Observations in Near-Real Time for Simulation and Analysis of Biosphere–Atmosphere Interactions

The National Ecological Observatory Network (NEON) is a continental-scale observatory with sites across the US collecting standardized ecological observations that will operate for multiple decades. To maximize the utility of NEON data, we envision edge computing systems that gather, calibrate, aggregate, and ingest measurements in an integrated fashion. Edge systems will employ machine learning methods to cross-calibrate, gap-fill and provision data in near-real time to the NEON Data Portal and to High Performance Computing (HPC) systems, running ensembles of Earth system models (ESMs) that assimilate the data. For the first time gridded EC data products and response functions promise to offset pervasive observational biases through evaluating, benchmarking, optimizing parameters, and training new machine learning parameterizations within ESMs all at the same model-grid scale. Leveraging open-source software for EC data analysis, we are already building software infrastructure for integration of near-real time data streams into the International Land Model Benchmarking (ILAMB) package for use by the wider research community. We will present a perspective on the design and integration of end-to-end infrastructure for data acquisition, edge computing, HPC simulation, analysis, and validation, where Artificial Intelligence (AI) approaches are used throughout the distributed workflow to improve accuracy and computational performance.

Durden, David J.↗

Embedded anchoring of multi-material assemblies by friction riveting process

In this paper, we report on work that focused on extending the capability and broaden the applicability of the friction-riveting process for joining stacks composed of a wide range of multi-layer polymer-to-metals and similar and dissimilar metals. We first present direct experimental evidence of our use of this process to join aluminum-to-steel dissimilar metals with steel rivets. We have demonstrated for the first time the use of magnesium as a rivet material for joining carbon fiber reinforced polymer (CFRP) stacks, aluminum as a rivet material to laminate magnesium to CFRP, and aluminum-to-aluminum similar metal joining and aluminum-to-steel dissimilar metal joining with steel rivets. Our work sheds light on detailed process parameter optimization and the corresponding process response behavior, thus advancing our understanding of this complex joining method for a wide range of material combinations.

Friction-riveting, magnesium rivet, carbon fiber r↗

Integrating Natural Language Processing and Machine Learning Algorithms to Categorize Oncologic Response in Radiology Reports

A significant volume of medical data remains unstructured. Natural language processing (NLP) and machine learning (ML) techniques have shown to successfully extract insights from radiology reports. However, the codependent effects of NLP and ML in this context have not been well-studied. Between April 1, 2015 and November 1, 2016, 9418 cross-sectional abdomen/pelvis CT and MR examinations containing our internal structured reporting element for cancer were separated into four categories: Progression, Stable Disease, Improvement, or No Cancer. We combined each of three NLP techniques with five ML algorithms to predict the assigned label using the unstructured report text and compared the performance of each combination. The three NLP algorithms included term frequency-inverse document frequency (TF-IDF), term frequency weighting (TF), and 16-bit feature hashing. The ML algorithms included logistic regression (LR), random decision forest (RDF), one-vs-all support vector machine (SVM), one-vs-all Bayes point machine (BPM), and fully connected neural network (NN). The best-performing NLP model consisted of tokenized unigrams and bigrams with TF-IDF. Increasing N-gram length yielded little to no added benefit for most ML algorithms. With all parameters optimized, SVM had the best performance on the test dataset, with 90.6 average accuracy and F score of 0.813. The interplay between ML and NLP algorithms and their effect on interpretation accuracy is complex. The best accuracy is achieved when both algorithms are optimized concurrently.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In-situ sensor monitoring of multi-class gas porosity formation in laser powder bed fusion using convolutional neural network

In-situ monitoring of defect formation remains a significant challenge in the laser powder bed fusion (LPBF) process. Recent advances have enabled real-time defect detection with machine learning and in-situ sensing technologies; however, most studies focus on binary classification of keyhole pores, limiting nuanced multi-class pore differentiation and formation mechanisms. This work introduces a multi-class pore detection framework (no pore, small pores < 15 µm, and large pores > 15 µm) by leveraging photodiode sensor data alongside high-fidelity synchrotron X-ray imaging. The 15 µm threshold is selected to distinguish between two fundamentally different defect mechanisms, following the physical size-mechanism boundary established by prior high-resolution synchrotron X-ray characterization of Al6061 LPBF. Distinguishing these classes is critical because large keyhole pores are structurally detrimental, whereas small gas pores are often benign, requiring different process control strategies. Thermal emission monitoring data collected simultaneously with high-speed X-ray imaging at the Stanford Synchrotron Radiation Lightsource (SSRL), are correlated with subsurface melt pool dynamics to establish ground truth. Continuous Wavelet Transform (CWT) with optimized parameters converts the photodiode time-series signals into time–frequency images, facilitating feature extraction. Convolutional Neural Networks (CNN) are then applied for real-time multi-class pore classification in an average inference time of 1 ms per signal window. It achieves 79% accuracy and an Area Under the Receiver Operating Characteristic curve (AUC ROC) score of 0.89 with five-fold cross-validation. The results demonstrate that coupling CWT-based feature engineering with CNN architecture enables reliable multi-class pore detection in Al6061 builds using affordable in-situ sensors. This approach advances scalable and affordable quality assurance in additive manufacturing by moving beyond binary defect detection toward more nuanced classification of porosity mechanisms with in-situ sensors and machine learning.

Laser powder bed fusion, Multi-class pores, In-sit↗

Creep Behavior of a High-$\gamma^{\prime}$ Ni-Based Superalloy Fabricated via Electron Beam Melting

Additive manufacturing enables the fabrication of complex engineering components previously inaccessible through traditional processes. Nickel-base superalloys with large γ' volume fraction are typically considered non-weldable and therefore exhibit a propensity for cracking during the fusion process. These crack-prone materials, however, are of great importance in gas turbine engines due to their excellent high temperature creep resistance. In this study we investigate the creep behavior of IN738LC produced by the electron beam melting process. Here, we find that with appropriate post-build heat treatment the creep response of material oriented in the build direction exhibits deformation and rupture behavior comparable to that of conventionally cast IN738 & IN738LC. In the transverse direction properties fall below the expected cast behavior, however, we argue this is likely due to differences in grain scale and crystallographic texture. It may be possible to coarsen the grain morphology with appropriate process-parameter optimization in order to reduce the severity of intergranular fracture in the transverse direction. These results illustrate that high temperature properties exhibited by additively manufactured IN738LC are suitable for the hot section of gas turbine engines.

36 MATERIALS SCIENCE↗