The development of a positive isolation disconnect
Conceptual design and developmental testing were conducted to determine the feasibility of a highly reliable, positive isolation disconnect (PID) for potential inflight maintenance of Shuttle environmental control/life support system subsystems. The PID design consists of two coupled valves, each capable of fluid isolation through the use of individually operated opposing poppets. An integral level clamping mechanism couples the two valves and locks the bodies together. The coupling lever is locked in position by turning the valve stems that have foolproof caps. The stem shaft has an integral cam that turns inside a yoke to open the poppet to permit fluid flow. Results of 5000 life cycle tests, hydraulic lock test, leakage tests, and pressure drop tests are included.