Search NASA⌕ Search

SEARCH · Search NASA

Results for “power flow initialization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Methodology of Experiment Design for Improving Transient Critical Heat Flux Model Development

One phenomenon that contributes to nuclear fuel and clad failure mechanisms is the departure from nucleate boiling (DNB). Accident scenarios such as reactivity-initiated accidents (RIAs) provide conditions where the frequency of boiling crisis is much more likely to occur and on much shorter time scales than loss of coolant (LOCA) or loss of flow (LOFA) accidents. Here, boiling crisis in the form of DNB is attributed to transient-induced heat flux values that exceed the critical heat flux (CHF). The resulting effects, such as bubble crowding and eventual dryout, can affect flow boiling heat transfer and compromise the structural integrity of nuclear reactor materials. The focus of the work proposed here lies in developing a rigorous process using out-of-pile testing, under simulated RIA conditions, to determine the transient critical heat flux of cladding materials, without contributions from aforementioned radiation-induced effects that have been observed during in-pile experiments. This study provides a road-map for developing and performing experiments that simulate the power profile and energy deposition aspects of transient events, specific to RIAs, on the laboratory scale. The goal of our project is to observe and measure DNB in an annular flow channel around a single heater rod that is operating and nominal thermal hydraulic conditions of a PWR. It is also an aim of these experiments to determine how to quantify the gap between SS and transient CHF cases, based on state-dependent properties of the cladding material type that is being interrogated. Traditionally, CHF is determined as a combination of four factors: hydraulic diameter, system pressure, mass flow, fluid quality. The authors propose that an additional measureable quantity, which is dependent on the structural properties of the cladding material itself, is partly reasonable for the difference between measured and model-developed CHF values. Using a carefully metered approach will allow for several key concepts to be realized: compensation for transient-based effects to current models for CHF; adaptation of current models for different cladding material types, including Gen-IV concept materials; and implementation of a correction factor to account for both power transient-based and radiation-induced effects on the CHF that have not yet been accounted for.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Transformational Natural Gas Fueled Dynamic SOFC for Data Center in-Rack Power (Final Technical Report)

Data centers consume 250TWh or 1% of global electricity use in 2019. This electricity demand is expected to grow exponentially in the future. The current data center power supply relies on electric grids with diesel engines and batteries as backup; the latter is critically important because a sudden loss of power could erase crucial data, causing catastrophic economic loss. However, such a double protection architecture is costly, inefficient and polluting. In search for better in-rack power system, fuel-cell based generators have recently emerged as a promising alternative to diesel engines and batteries because of its potential to be more cost-effective, more efficient and less polluting. Among many types of fuel cells, solid oxide fuel cells stand out to be a front runner because of their ability to directly operate on natural gas that has an existing infrastructure. However, there are several critical challenges facing SOFC generators to meet the rigorous power requirements of data centers: high cost, poor reliability and more importantly, slow response to the datacenters’ dynamic load change. The unexpected overload conditions in data centers can cause fuel starvation; the latter can initiate microcracks in the anode structure, thus jeopardizing the lifetime of the SOFC generator. The current efforts to increase transient power capabilities of traditional SOFCs and therefore protect SOFC stacks from internal damage during transient loading, rely primarily upon mathematical algorithms. One of the challenges to these control methodologies is the physical limitations of the fuel delivery system such as slow response of mass flow controllers to fast power demand.

30 DIRECT ENERGY CONVERSION↗

Trailing edge wake flow characteristics of upper surface blown configurations

Mean and fluctuating flow characteristics in the wake of upper surface blown flap configurations are presented. Relative importance of the longitudinal and the transverse components of the wake flow turbulence for noise generation are evaluated using correlation between the near-field noise and the wake turbulence. Effects of the jet velocity, the initial turbulence in the jet, and the flap deflection angle on noise and wake flow characteristics are studied. The far-field noise data is compared with the existing empirical prediction method. The measured wake flow properties are compared with an analytical model used in the existing USB wake flow noise theory. The detailed wake flow profiles, wake flow turbulence space-time correlations, wake flow turbulence cross-power spectra, and near-field noise third octave band spectra are presented in the appendices.

Reddy, N. N.↗

Development of a Compact, Deep-Penetrating Heat Flow Instrument for Lunar Landers: In-Situ Thermal Conductivity System

Geothermal heat flow is obtained as a product of the geothermal gradient and the thermal conductivity of the vertical soil/rock/regolith interval penetrated by the instrument. Heat flow measurements are a high priority for the geophysical network missions to the Moon recommended by the latest Decadal Survey and previously the International Lunar Network. One of the difficulties associated with lunar heat flow measurement on a robotic mission is that it requires excavation of a relatively deep (approx 3 m) hole in order to avoid the long-term temporal changes in lunar surface thermal environment affecting the subsurface temperature measurements. Such changes may be due to the 18.6-year-cylcle lunar precession, or may be initiated by presence of the lander itself. Therefore, a key science requirement for heat flow instruments for future lunar missions is to penetrate 3 m into the regolith and to measure both thermal gradient and thermal conductivity. Engineering requirements are that the instrument itself has minimal impact on the subsurface thermal regime and that it must be a low-mass and low-power system like any other science instrumentation on planetary landers. It would be very difficult to meet the engineering requirements, if the instrument utilizes a long (> 3 m) probe driven into the ground by a rotary or percussive drill. Here we report progress in our efforts to develop a new, compact lunar heat flow instrumentation that meets all of these science and engineering requirements.

Nagihara, S.↗

An Initial Study of the Fundamentals of Ice Crystal Icing Physics in the NASA Propulsion Systems Laboratory

This presentation shows results from an initial study of the fundamental physics of ice-crystal ice accretion using the NASA Propulsion Systems Lab (PSL). Ice accretion due to the ingestion of ice-crystals is being attributed to numerous jet-engine power-loss events. The NASA PSL is an altitude jet-engine test facility which has recently added a capability to inject ice particles into the flow. NASA is evaluating whether this facility, in addition to full-engine and motor-driven-rig tests, can be used for more fundamental ice-accretion studies that simulate the different mixed-phase icing conditions along the core flow passage of a turbo-fan engine compressor. The data from such fundamental accretion tests will be used to help develop and validate models of the accretion process. The present study utilized a NACA0012 airfoil. The mixed-phase conditions were generated by partially freezing the liquid-water droplets ejected from the spray bars. This presentation shows data regarding (1) the freeze out characteristics of the cloud, (2) changes in aerothermal conditions due to the presence of the cloud, and (3) the ice accretion characteristics observed on the airfoil model. The primary variable in this test was the PSL plenum humidity which was systematically varied for two duct-exit-plane velocities (85 and 135 ms) as well as two particle size clouds (15 and 50 m MVDi). The observed clouds ranged from fully glaciated to fully liquid, where the liquid clouds were at least partially supercooled. The air total temperature decreased at the test section when the cloud was activated due to evaporation. The ice accretions observed ranged from sharp arrow-like accretions, characteristic of ice-crystal erosion, to cases with double-horn shapes, characteristic of supercooled water accretions.

upwind schemes↗

An Initial Study of the Fundamentals of Ice Crystal Icing Physics in the Nasa Propulsion Systems Laboratory

This paper presents results from an initial study of the fundamental physics of ice-crystal ice accretion using the NASA Propulsion Systems Lab (PSL). Ice accretion due to the ingestion of ice-crystals is being attributed to numerous jet-engine power-loss events. The NASA PSL is an altitude jet-engine test facility which has recently added a capability to inject ice particles into the flow. NASA is evaluating whether this facility, in addition to full-engine and motor-driven-rig tests, can be used for more fundamental ice-accretion studies that simulate the different mixed-phase icing conditions along the core flow passage of a turbo-fan engine compressor. The data from such fundamental accretion tests will be used to help develop and validate models of the accretion process. The present study utilized a NACA0012 airfoil. The mixed-phase conditions were generated by partially freezing the liquid-water droplets ejected from the spray bars. This paper presents data regarding (1) the freeze out characteristics of the cloud, (2) changes in aerothermal conditions due to the presence of the cloud, and (3) the ice accretion characteristics observed on the airfoil model. The primary variable in this test was the PSL plenum humidity which was systematically varied for two duct-exit-plane velocities (85 and 135 ms) as well as two particle size clouds (15 and 50 m MVDi). The observed clouds ranged from fully glaciated to fully liquid, where the liquid clouds were at least partially supercooled. The air total temperature decreased at the test section when the cloud was activated due to evaporation. The ice accretions observed ranged from sharp arrow-like accretions, characteristic of ice-crystal erosion, to cases with double-horn shapes, characteristic of supercooled water accretions.

Evaporative Cooling↗

2017 Grid Modernization Peer Review Report; Foundational Projects and Technical Area Portfolio Review

In April 2017, the U.S. Department of Energy’s (DOE’s) Grid Modernization Initiative (GMI) conducted its first external peer review of the projects awarded to the Grid Modernization Laboratory Consortium (GMLC) to execute a diverse portfolio of technologies to modernize the nation’s grid. The six technology areas reviewed during the 2017 Project Peer Review were: Design and Planning Tools; Devices and Integrated Systems; Institutional Support, Security and Resilience; Sensing and Measurement; and System Operations, Power Flow, and Control. Results of the 2017 Peer Review have been, and will be, used to help inform programmatic decision making, modify or discontinue existing projects, guide future funding opportunities, and support other budget and strategic planning objectives.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coupling CTF to MPACT for Improved Thermal-Hydraulic Feedback for Transients

As computational power and techniques continue to advance, reactor analysis codes are afforded the opportunity to employ a more detailed physics model. One area where this has manifested is with coupled neutron kinetics and thermal-hydraulics codes for transient analysis, in which the feedback is critical for accurate modeling. The Michigan Parallel Characteristics Transport (MPACT) code is a 3-D method of characteristics neutron transport code capable of generating sub-pin level power distributions being developed by the University of Michigan through the Consortium for Advanced Simulation of LWRs (CASL) program. Currently, MPACT handles thermal-hydraulic feedback with an internal 1-D radial heat transfer model assuming constant moderator temperature. While this relatively simple treatment of thermal-hydraulic feedback has been shown to accurately model transients where Doppler feedback is the dominant feedback mechanism, coupling MPACT to a detailed thermal-hydraulic code will greatly expand the range of transient problems that can be accurately modeled. COBRA-TF (CTF) is a 3-D two-phase flow, subchannel thermal-hydraulics code maintained by Penn State University through CASL. CTF is based upon the Semi-Implicit Method for Pressure-Linked Equations, and it is especially well suited to model heat transfer and fluid flow phenomena associated with a nuclear reactor through a wide range of conditions. We present an initial effort coupling MPACT to CTF for transients, which provides a wider range of transient problems that can be modeled with increased accuracy. We have successfully coupled the thermal-hydraulics code CTF to the neutronics code MPACT for transient calculations by implicit and Crank-Nicolson methods, which have been demonstrated with single pin and 3x3 configurations. This capability extends the ability of MPACT to accurately model transients through a wider range of conditions than the existing thermal-hydraulic feedback, which is severely limited by the assumption of constant moderator temperature and density. By employing CTF for the thermal- hydraulic feedback, the transient physics can be described more completely at minimal computational expense. (authors)

42 ENGINEERING↗

Large-Eddy Simulation of Variable Speed Power Turbine Cascade with Inflow Turbulence

Numerical results are presented from theNASAGlenn Research Center’sin-house turbomachinery code, Glenn-HT applied to the Variable Speed Power Turbine (VSPT) experiment at the NASA Transonic Turbine Blade Cascade Facility.The main goal of this paper is to implement a digital filtering method to generate turbulence upstream and a sub-grid model (Localized dynamic k-equation model (LDKM)) in the framework of LES in order to investigate the effect of inflow turbulence on the transition seen in the VSPT experimental data at the cruise condition (incidence angle of 40oand Tu = 0.5%, 5%,10%, and 15%). Although the boundary layer on thesuction side and pressure side of the blades is initially laminar due to favorable pressure gradient, the laminar flow can transition to turbulent flow past a separation zoneon the suction sideor by natural or by-pass transition. This process determinesthe total-pressure lossesin the wake. Therefore, it is desirable to develop a reliable prediction tool to accurately capture the transition mechanism in blade rows operated under the conditions of low Reynolds number andat a variety offree stream turbulence conditions. Our numerical studies reveal that the location of separationis rather insensitive to the level of Tu, however the effect ofincreasingTu seems to be in reducing the size and ultimately suppressing the separation bubble. In addition, we performedspectral analysis to identify the peak frequencies in the region where the separation bubble is formed, which provides valuable insights into the transition/separation mechanism.

CFD↗

Liquid Sampling-Atmospheric Pressure Glow Discharge (LS-APGD) Ionization Source for Elemental Mass Spectrometry: Preliminary Parametric Evaluation and Figures of Merit

A new, low power ionization source for the elemental analysis of aqueous solutions has recently been described. The liquid sampling-atmospheric pressure glow discharge (LS-APGD) source operates at relatively low currents (<20 mA) and solution flow rates (<50 μL min-1), yielding a relatively simple alternative for atomic mass spectrometry applications. The LS-APGD has been interfaced to what is otherwise an organic, LC-MS mass analyzer, the Thermo Scientific Exactive Orbitrap without any modifications; other than removing the electrospray ionization (ESI) source supplied with that instrument. A glow discharge is initiated between the surface of the test solution exiting a glass capillary and a metallic counter electrode mounted at a 90° angle and separated by a distance of ~5 mm. As with any plasma-based ionization source, there are key discharge operation and ion sampling parameters that affect the intensity and composition of the derived mass spectra; including signal-to-background ratios. We describe here a preliminary parametric evaluation of the roles of discharge current, solution flow rate, argon sheath gas flow rate, and ion sampling distance as they apply on this mass analyzer system. A cursive evaluation of potential matrix effects due to the presence of easily ionized elements (EIEs) indicate that sodium concentrations of up to 500 μg mL-1 generally cause suppressions of less than 50%, dependant upon the analyte species. Based on the results of this series of studies, preliminary limits of detection (LOD) have been established through the generation of calibration functions. Whilst solution-based concentrations LOD levels of 0.02 – 2 μg mL-1 3 are not impressive on the surface, the fact that they are determined via discrete 5 μL injections leads to mass-based detection limits at picogram to singlenanogram levels. The overhead costs associated with source operation (10 W d.c. power, solution flow rates of <50 μL min-1, and gas flow rates <10 mL min-1) are very attractive. While further optimization in the source design is suggested here, it is believed that the LS-APGD ion source may present a practical alternative to inductively-coupled plasma (ICP) sources typically employed in elemental mass spectrometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advances in Electrically Driven Thermal Management

Electrically Driven Thermal Management is a vibrant technology development initiative incorporating ISS based technology demonstrations, development of innovative fluid management techniques and fundamental research efforts. The program emphasizes high temperature high heat flux thermal management required for future generations of RF electronics and power electronic devices. This presentation reviews i.) preliminary results from the Electrohydrodynamic (EHD) Long Term Flight Demonstration launched on STP-H5 payload in February 2017 ii.) advances in liquid phase flow distribution control iii.) development of the Electrically Driven Liquid Film Boiling Experiment under the NASA Microgravity Fluid Physics Program.

Thermal Control Multifunctional Hardware↗

Conversion of CO 2 from power plant into CaCO 3 nanoparticles

Carbon dioxide (CO 2 ), a main composition of flue gas, represents a significant and largely untapped carbon resource. Herein, mediated by glycine (Gly), we captured and converted CO 2 into CaCO 3 nanoparticles using real flue gas from a power plant, demonstrating for the first time the feasibility of using amino acid to convert CO 2 from power plant flue gasses. The method did not require extraneous energy and CaCO 3 nanoparticles with a size of ∼25 nm were obtained. Moreover, the potential toxicity of CO 2 -converted nanoparticles was investigated. It appeared that both the initial CO 2 loading and the carbamate percentage significantly influence the shape and size of the CaCO 3 particles. Our method was also proven effective for flue gas with varying CO 2 concentrations (4 %, 12 %, and 20 %). By tuning flue gas bubbling time and flow rate to achieve consistent CO 2 loading and carbamate levels, we produced CaCO 3 nanoparticles with similar shapes and sizes across all CO 2 concentrations studied. In addition, our data indicated that although real flue gas contains small amounts of gases like oxygen and CO, they insignificantly influence the shape and size of our nanoparticles but did impact the phase component of CaCO 3 . In conclusion, the toxicity experiments found that CaCO 3 nanoparticles produced from both real flue gas and simulated flue gas exhibited concentration- and time-dependent effects on cell viability.

36 MATERIALS SCIENCE↗

FY24 Report on Water NSTF Testing: Lower Tank Inlet Piping Configuration

The following report serves as a summary of the accomplishments and testing results by the Natural convection Shutdown heat removal Test Facility (NSTF) experimental program over the past 12-month period. A major activity included reconfiguration of the chimney piping geometry which altered the discharge position into the tank from the original 50% tank height to a new lower position at a 10.9% tank height. This modification increases the volume of available coolant thus extending long-term operating capacity, however also results in a decreased liquid driving head which has the potential to reduce the natural circulation efficiency and decrease overall performance. Examination of the tradeoffs for these two configurations is an area of interest for RCCS designers and drove planned test activities this year. Ten matrix tests were performed in FY24, totaling 195 hours of heated operations and 12.9 MWh of electrical heating throughout the year, with eight classified as Accepted per NQA-1 and two classified as Trending. Testing prior to the facility reconfiguration examined the facility response to throttling at the tank inlet, demonstrating increased sensitivity of flow instabilities to throttling within the two-phase region when compared to throttling at the lower sensitivity single-phase inlet region. Testing after the chimney reconfiguration began with a baseline test at conditions of 80% inventory fill and prototypic thermal power input of 2.1 MW t . In addition to establishing a reference for nominal system behavior and performance, repeat testing with multiple subsequent runs demonstrated strong repeatability between tests performed at the same conditions in this new configuration. These tests also examined if influences would occur to system behavior with installation of new higher-resolution instrumentation within the upper chimney. In this critical region where boiling and flashing phenomena dominate, the test results provided confidence that the new instrumentation does not uncharacteristically influence the observed behaviors. An inventory parametric series was then initiated to examine system behavior with the new chimney configuration at six varying initial inventory levels, ranging from high 80% to low 20% fill. Two-phase oscillations with similar peak and mean flow rates were observed when comparing to the previous mid tank configuration. Generally, similar system response trends with inventory were also observed, such as two phase oscillations suppressing as inventories were lowered. However, in one absolute inventory comparison at the highest fill of 80%, flow oscillations saw a gradual growth over the 4 hours of two-phase operation in the new lower tank inlet configuration, opposite of the gradual dampening observed in the mid tank inlet configuration. This can be attributed to, in part, a greater hydrostatic head pressure above the two-phase discharge region where the boiling front is developed. Furthermore, the change resulted in greater sensitivity to liquid degassing phenomena during single-phase heating, causing loop instabilities to form which trigged moderate flow degradation during the period approaching saturation and boiling conditions. This behavior had been observed previously under some conditions but was a common occurrence in recent testing with the newer lower tank inlet configuration. Initial observations from these first data sets suggest an overall larger window of stability for the mid tank inlet configuration compared to the lower tank inlet. Lastly, the lowest inventory fill test was repeated over an extended testing window to examine depletion behavior. Natural circulation flow and effective heat removal performance were observed during most of the testing period; only after the tank became fully drained (0% fill) did flow stagnate and violent geysering events occur. This early observation confirms one relative advantage over the mid tank inlet configuration, which stagnated under comparable conditions at ~20% inventory remaining in the tank.

42 ENGINEERING↗

Regenerative Carbonate-Based Thermochemical Energy Storage System for Concentrating Solar Power

Southern Research has developed a thermochemical energy storage (TCES) technology that utilizes the endothermic-exothermic reversible carbonation of calcium oxide (lime) to store thermal energy at high-temperatures, such as those achieved by next generation concentrating solar power (CSP) facilities. The major challenges addressed in the development of this system include refining a high capacity, yet durable sorbent material and designing a low thermal resistance low-cost heat exchanger reactor system to move heat between the sorbent and a heat transfer fluid under conditions relevant for CSP operation (e.g., energy density, reaction kinetics, heat flow). The proprietary stabilized sorbent was developed by Precision Combustion, Inc. (PCI). A factorial matrix of sorbent compositions covering the design space was tested using accelerated high throughput screening in a thermo-gravimetric analyzer. Several promising formulations were selected for more thorough evaluation and one formulation with high capacity (0.38 g CO 2 /g sorbent) and durability (>99.7% capacity retention over 100 cycles) was chosen as a basis for further development of the energy storage reactor system. In parallel with this effort, a full range of currently available commercial and developmental heat exchange reactor systems and sorbent loading methods were examined through literature research and contacts with commercial vendors. Process models were developed to examine if a heat exchange reactor system and balance of plant can meet required TCES performance and cost targets, optimizing tradeoffs between thermal performance, exergetic efficiency, and cost. Reactor types evaluated included many forms, from microchannel reactor, to diffusion bonded heat exchanger, to shell and tube heat exchangers. The most viable design for application to a supercritical CO 2 power cycle operating at 200-300 bar pressure and >700°C was determined to be a combination of a diffusion bonded heat exchanger with a shell and tube reactor. A bench scale reactor system was then designed and constructed to test sorbent performance under more commercially relevant conditions. This system utilizes a tube-in tube reactor design containing approximately 250 grams sorbent and is able to operate under a wide range of temperature, pressure and flow conditions as needed to explore system performance under a variety of operating conditions. A variety of sorbent loading methods may be tested using the reactor design. Initial bench test results over 25 cycles showed very high sorbent stability (>99%) and sufficient capacity (>0.28 g CO 2 /g sorbent) for an economical commercial-scale system. Initial technoeconomic evaluation of the proposed storage system show that the sorbent cost should not have a significant impact on overall system cost, and that the largest cost impacts come from the heat exchanger reactor and balance of plant equipment, including compressors and gas storage, due to the high temperatures for sCO 2 cycles. Current estimated system costs are $47/kWhth based on current material and equipment cost estimates.

14 SOLAR ENERGY↗

Enabling BWR fuel rod analysis in the BISON fuel performance code

Nuclear fuel vendors around the world are pursuing approaches to sustain the existing nuclear reactor fleet consisting primarily of pressurized-water reactors (PWRs) and boiling-water reactors (BWRs). To support the industry's efforts, advanced modeling and simulation tools need to be capable of analyzing both legacy reactor concepts. BWR fuel rods are significantly different than those used in PWRs, which can affect fuel performance analysis. BWR fuel rods include: (1) an extensive use of gadolinia dopant as a burnable absorber, (2) an axial variation in fuel enrichment and gadolinia content, (3) the inclusion of a liner on the inner cladding surface to mitigate the impact of pellet-clad mechanical interaction (which impacts hydrogen and hydride distribution), (4) a lower initial fill gas pressure, (5) bottom-entry control rods, and (6) a lower coolant pressure that results in the two-phase flow boiling phenomenon. Although the primary focus of BISON has been in the area of PWR and advanced reactor fuel analyses, this paper presents the developments in BISON to support BWR fuel performance analysis. An overview of the models that account for the effects of gadolinia is highlighted. Internal mesh generation capabilities to include a liner is presented. Normal operating and transient (reactivity insertion accident) demonstration problems are presented to illustrate the impact of gadolinia, the hydrogen and hydride evolution due to the presence of the liner, and BISON's ability to simulate axially varying enrichments and dopant concentration. Bottom-entry control effects are captured by the axial power peaking factors present in the demonstration cases. Comparisons to integral experiments from the Halden IFA-681 experiments are discussed as initial validation. Reasonable comparisons are obtained for fuel centerline temperature and rod internal pressure as a function of time. In conclusion, simulations of additional experiments containing Gd 2 O 3 -bearing fuel are necessary to completely validate the code for BWR applications.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Molecular-scale investigation of the oxidation behavior of chromia-forming alloys in high-temperature CO2

Abstract Current and future power systems require chromia-forming alloys compatible with high-temperature CO 2 . Important questions concerning the mechanisms of oxidation and carburization remain unanswered. Herein we shed light onto these processes by studying the very initial stages of oxidation of Fe22Cr and Fe22Ni22Cr model alloys. Ambient-pressure X-ray photoelectron spectroscopy enabled in situ analysis of the oxidizing surface under 1 mbar of flowing CO 2 at temperatures up to 530 °C, while postexposure analyses revealed the structure and composition of the oxidized surface at the near-atomic scale. We found that gas purity played a critical role in the kinetics of the reaction, where high purity CO 2 promoted the deposition of carbon and the selective oxidation of Cr. In contrast, no carbon deposition occurred in low purity CO 2 and Fe oxidation ensued, thus highlighting the critical role of impurities in defining the early oxidation pathway of the alloy. The Cr-rich oxide formed on Fe22Cr in high purity CO 2 was both thicker and more permeable to carbon compared to that formed on Fe22Ni22Cr, where carbon transport appeared to occur by atomic diffusion through the oxide. Alternatively, the Fe-rich oxide formed in low purity CO 2 suggested carbon transport by molecular CO 2 .

36 MATERIALS SCIENCE↗

Developing the Pulsed Fission-Fusion (PuFF) Engine

In September 2013 the NASA Innovative Advanced Concept (NIAC) organization awarded a phase I contract to the PuFF team. Our phase 1 proposal researched a pulsed fission-fusion propulsion system that compressed a target of deuterium (D) and tritium (T) as a mixture in a column, surrounded concentrically by Uranium. The target is surrounded by liquid lithium. A high power current would flow down the liquid lithium and the resulting Lorentz force would compress the column by roughly a factor of 10. The compressed column would reach criticality and a combination of fission and fusion reactions would occur. Our Phase I results, summarized herein, review our estimates of engine and vehicle performance, our work to date to model the fission-fusion reaction, and our initial efforts in experimental analysis.

Adams, Robert B.↗

12-kW Advanced Electric Propulsion System Hall Current Thruster Qualification and Production Status

The AEPS contract was awarded to AR in May of 2016 with the goal of developing a 12.5kW Hall Thruster System, including the Hall Current Thruster (HCT), Power Processor Unit (PPU) and Xenon Flow Controller (XFC). It was originally targeted to support the Asteroid Redirect Mission, which was cancelled early in the project. The project was subsequently restructured to support the Gateway PPE propulsion mission, with modified scope that consisted of the development, qualification and delivery of three 12kW flight thrusters. The PPU and XFC components were designed and development hardware fabricated with initial testing performed prior to being de-scoped from the contract. System level testing was performed by AR using these engineering components in early 2022 at the Aerospace Corporation’s EP-3 test facility.

Hall thruster↗