Search NASA⌕ Search

SEARCH · Search NASA

Results for “powered”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Self-powered Heating: Efficiency Analysis

Conventional fuel-fired heating devices such as furnaces, boilers, and water heaters have fuel efficiency less than 100% on the basis of higher heating value. They also require electricity from the electric grid to power parasitic loads such as blowers, pumps, fans, and ignitors. The primary energy efficiency of the device accounts for both fuel used on-site and primary energy used off-site to produce electric power used by the device. This work compares conventional fuel-fired heating devices to two types of self-powered devices. A self-powered device (SPD) integrates a power cycle onboard to eliminate consumption of grid electricity. We assume that all heat rejected by the onboard power cycle is added to the process fluid, so that, compared with a conventional device, the same amount of heat is provided to the process fluid and the same amount of fuel is consumed, but grid electricity consumption is eliminated. The first SPD type is the basic one: exactly the electricity required is generated. The second type considered is the SPD with heat pump (SPD-HP), in which the power cycle generates more electricity than needed for parasitic loads, and the excess electricity is used to power a heat pump. The heat pump extracts additional heat from the ambient to boost efficiency. Both SPD and SPD-HP self-consume all the generated electricity, in contrast to combined heat and power (CHP) systems that export electricity. In this work, equations are derived to express the efficiency of three classes of heating devices: conventional (consuming grid electricity), self-powered (consuming no grid electricity), and self-powered with heat pump. The efficiency of each is derived as a function of up to six factors: (1) the fraction of combustion heat captured, (2) the rate of parasitic power consumption, (3) the fraction of electric energy dissipated as useful heat, (4) the power cycle conversion efficiency, (5) the grid efficiency, when applicable, and (6) the heat pump COP, when applicable. Scenarios are identified in which it is possible to achieve efficiency greater than 100% on a higher heating value basis. Plausible configurations using existing technology options are outlined.

Gluesenkamp, Kyle↗

A Multi-Fidelity Gaussian Process Regression Method for Probabilistic Wind Farm Power Curve Estimation

Accurate estimation of the power curve for wind turbines or wind farms is crucial to ensure their efficient operation and management. However, conventional methods for power curve estimation rely either on expensive and infrequent measurements or on low-quality numerical simulations. Moreover, the majority of previous studies on power curve estimation for wind turbines or wind farms focused on deterministic estimation, which provides a point estimate of the relationship between wind speed and power generation. Nevertheless, the deterministic approach fails to consider the inherent uncertainty associated with wind energy production resulting from varying turbine characteristics. This can lead to inaccurate power generation estimation and suboptimal decisions regarding energy management. In this paper, a kernel density estimation (KDE) based Multi-Fidelity Gaussian Process Regression (MFGPR) model is proposed to fuse theoretical power curve data and the ground true measurements to create a mapping of wind speed and wind power. By conducting a case study on an actual wind farm in China, the efficacy of the proposed MFGPR model was demonstrated in characterizing the variability of wind power. The probabilistic MFGPR model was also able to generate confidence intervals that encompassed the measured power, thereby improving the accuracy and confidence in wind power estimation or wind resource assessment. Overall, the proposed MFGPR model offers a reliable approach to integrate high-fidelity ground measurements and theoretical power curve data, resulting in precise wind resource assessment and power estimation.

Gaussian process regression↗

Multi-modular power plant with dedicated electrical grid

A multi-modular power plant includes a plurality of on-site nuclear power modules that generate a power plant output, and a number of power plant systems which operate using electricity associated with a house load of the power plant. A switchyard associated with the power plant may electrically connect the power plant to a distributed electrical grid. The distributed electrical grid may be configured to service a plurality of geographically distributed consumers. Additionally, the switchyard may electrically connect the power plant to a dedicated electrical grid. The dedicated electrical grid may provide electricity generated from the power plant output to a dedicated service load, and the power plant output may be equal to or greater than a combined load of the dedicated service load and the house load. At least a portion of the power plant output may be distributed to both the power plant systems and the dedicated electrical grid.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Power System Wildfire Risks and Potential Solutions: A Literature Review & Proposed Metric

Several fire risk evaluation, fire tracking, and fire response resources are available. The risk metrics and fire response programs are sometimes modified to include a power system context. The risk metrics often evaluate the risk of fires causing power system faults or outages, especially on transmission systems. The response programs are modified to ensure the safety of power system equipment and first responders as well as to coordinate power system outages to both ensure safety during an active fire and prevent fire ignition during high risk periods. Although some aspects of wildfire responses have been adapted to include power system concerns, adaptations to power system operations and maintenance to include wildfire risks and responses are still nascent. In particular, a risk metric that evaluates the potential for power system components to ignite wildfires is needed to help guide power system upgrade efforts and power system fire safety measures. This document serves as a brief literature review of wildfire risk metrics and response programs and how they relate to power systems. It also includes a proposed risk metric and structure for describing the risk of a power system component igniting a fire.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Toward Energy-Efficient HPC: Insights from Power Profiling a Cloud-Resolving Earth System Model

Power is a fundamental constraint as supercomputing advances to exascale. Efficient operation within strict power budgets requires application-aware power management based on a detailed understanding of application-level power behavior. This work analyzes the Energy Exascale Earth System Model (E3SM) atmosphere component, SCREAM, on Perlmutter (NERSC) and Frontier (OLCF). We characterize power variation across inputs, concurrency levels, and power caps, evaluate the energy impact of code optimizations, and attribute energy within the code using a newly developed GPU energy model. Results show that SCREAM’s peak power remains stable during its core execution phase and decreases gradually as concurrency increases. Power capping experiments reveal a performance–energy "sweet spot". On Perlmutter, limiting GPU power to 50% of thermal design power (TDP) achieves up to 15% energy savings with a 7% performance penalty. On Frontier, a 40% TDP cap yields up to 10% energy savings with less than 10% performance loss. Code optimizations reduce SCREAM energy by shortening run time without increasing power. Modeling reveals a critical insight: data movement accounts for approximately 70% of SCREAM’s GPU energy. This fundamentally shifts the optimization focus from FLOPS to data transfer reduction for this class of applications, offering the most impactful strategy for improving energy efficiency. This work establishes a foundation for practical, application-aware power management at exascale.

Zhao, Zhengji [Lawrence Berkeley National Laborato↗

Impact of Time Dependent Reactor and Sensor Physics on Core Power Synthesis

Online synthesis of the power distribution is critical in the operation and control of nuclear power reactors to ensure that the core is operating within safety margins, and to provide essential knowledge associated with the burnup of the fuel. In light water reactors (LWRs), power synthesis is achieved by using some a priori knowledge of the state of the reactor core and updating based on the signals coming from in-core sensors—namely, self-powered neutron detectors (SPNDs). This report aims to study the effects of fuel burnup and sensor degradation on the ability to accurately synthesize the power distribution in a LWR. Several modeling tools were used to simulate power synthesis based on the responses of SPNDs, with emitters made out of Rh or V. A representative pressurized water reactor low-enriched uranium (LEU) core was modeled using the Polaris/Purdue Advanced Reactor Core Simulator (PARCS) approach. The Monte Carlo N-Particle Transport 6 (MCNP6) code was used, as well, to calculate response functions between different segments of fuel to individual SPNDs; this is a crucial parameter for power synthesis. The Oak Ridge Isotope GENeration (ORIGEN) package in the Standardized Computer Analyses for Licensing Evaluation (SCALE) code was used to model the time-dependent isotopic transmutation in the SPND emitters. All these data were fed into a custom code that enacted the point-based iterative (PBI) method to simulate power synthesis. Developmental work was also performed on high-fidelity SPND models in the GEometry ANd Tracking 4 (Geant4) code, which enables higher-accuracy modeling of the current responses from SPNDs. In this work, five sets of time-dependent power synthesis test cases were conducted. In these test cases, systematic changes in the input conditions enabled an analysis of the effect of (1) slightly inaccurate a priori power distribution assumptions with respect to fuel burnup, (2) highly inaccurate a priori assumptions with respect to fuel burnup (such that burnup is not included in the a priori assumed distribution), and (3) differences between Rh and V SPNDs in terms of downstream consequences of the transmutation in the emitters. The authors discovered that one may permissibly have slightly inaccurate a priori assumptions of the fuel burnup (such that the level of burnup may be slightly under- or over-approximated by the accumulated burnup in approximately 9.3 full power days), but to not account for burnup at all in the a priori assumption leads to severe levels of error, approaching 25% at maximum. The authors also discovered that V SPNDs are extraordinarily robust in the low-enriched uranium fuel cycle considered in this modeling work, whereas Rh SPNDs undergo significant transmutation that can result in large errors in the synthesized power distribution.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

How wind speed shear and directional veer affect the power production of a megawatt-scale operational wind turbine

Most megawatt-scale wind turbines align themselves into the wind as defined by the wind speed at or near the center of the rotor (hub height). However, both wind speed and wind direction can change with height across the area swept by the turbine blades. A turbine aligned to hub-height winds might experience suboptimal or superoptimal power production, depending on the changes in the vertical profile of wind, also known as shear. Using observed winds and power production over 6 months at a site in the high plains of North America, we quantify the sensitivity of a wind turbine's power production to wind speed shear and directional veer as well as atmospheric stability. We measure shear using metrics such as α (the log-law wind shear exponent), β bulk (a measure of bulk rotor-disk-layer veer), β total (a measure of total rotor-disk-layer veer), and rotor-equivalent wind speed (REWS; a measure of actual momentum encountered by the turbine by accounting for shear). We also consider the REWS with the inclusion of directional veer, REWS θ , although statistically significant differences in power production do not occur between REWS and REWS θ at our site. When REWS differs from the hub-height wind speed (as measured by either the lidar or a transfer function-corrected nacelle anemometer), the turbine power generation also differs from the mean power curve in a statistically significant way. This change in power can be more than 70 kW or up to 5 % of the rated power for a single 1.5 MW utility-scale turbine. Over a theoretical 100-turbine wind farm, these changes could lead to instantaneous power prediction gains or losses equivalent to the addition or loss of multiple utility-scale turbines. At this site, REWS is the most useful metric for segregating the turbine's power curve into high and low cases of power production when compared to the other shear or stability metrics. Therefore, REWS enables improved forecasts of power production.

17 WIND ENERGY↗

A surrogate-model-based approach for estimating the first and second-order moments of offshore wind power

Power curve, the functional relationship that governs the process of converting a set of weather variables experienced by a wind turbine into electric power, is widely used in the wind industry to estimate power output for planning and operational purposes. Existing methods for power curve estimation have three main limitations: (i) they mostly rely on wind speed as the sole input, thus ignoring the secondary, yet possibly significant effects of other environmental factors, (ii) they largely overlook the complex marine environment in which offshore turbines operate, potentially compromising their value in offshore wind energy applications, and (ii) they solely focus on the first-order properties of wind power, with little (or null) information about the variation around the mean behavior, which is important for ensuring reliable grid integration, asset health monitoring, and energy storage, among others. In light of that, this study investigates the impact of several wind-and wave-related factors on offshore wind power variability, with the ultimate goal of accurately predicting its first two moments. Further, our approach couples OpenFAST—a multi-physics wind turbine simulator—with Gaussian Process (GP) regression to reveal the underlying relationships governing offshore weather-to-power conversion. We first find that a multi-input power curve which captures the combined impact of wind speed, direction, and air density, can provide double-digit improvements, in terms of prediction accuracy, relative to univariate methods which rely on wind speed as the sole explanatory variable (e.g. the standard method of bins). Wave-related variables are found not important for predicting the average power output, but interestingly, appear to be extremely relevant in describing the fluctuation of the offshore power around its mean. Tested on real-world data collected at the New York/New Jersey bight, our proposed multi-input models demonstrate a high explanatory power in predicting the first two moments of offshore wind generation, testifying their potential value to the offshore wind industry.

17 WIND ENERGY↗

Establishing nationwide power system vulnerability index across US counties using interpretable machine learning

Power outages have become increasingly frequent, intense, and prolonged in the US due to climate change, aging electrical grids, and rising energy demand. However, largely due to the absence of granular spatiotemporal outage data, we lack data-driven evidence and analytics-based metrics to quantify power system vulnerability. This limitation has hindered the ability to effectively evaluate and address vulnerability to power outages in US communities. Here, in this work, we collected ∼179 million power outage records at 15-min intervals across 3022 US contiguous counties (96.15 % of the area) from 2014 to 2023. We developed a power system vulnerability assessment framework based on three dimensions (intensity, frequency, and duration) and applied interpretable machine learning models (XGBoost and SHAP) to compute Power System Vulnerability Index (PSVI) at the county level. Our analysis reveals a consistent increase in power system vulnerability across the US counties over the past decade. We identified 318 counties across 45 states as hotspots for high power system vulnerability, particularly in the West Coast (California and Washington), the East Coast (Florida and the Northeast area), the Great Lakes megalopolis (Chicago-Detroit metropolitan areas), and the Gulf of Mexico (Texas). Our heterogeneity analysis indicates that urban counties and those located along regional transmission boundaries tend to exhibit significantly higher vulnerability. Our results highlight the significance of the proposed PSVI for evaluating the vulnerability of communities to power outages. The findings underscore the widespread and pervasive impact of power outages across the country and offer crucial insights to support infrastructure operators, policymakers, and emergency managers in formulating policies and programs aimed at enhancing the resilience of the US power infrastructure.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Physics-Informed Gaussian Process Regression for States Estimation and Forecasting in Power Grids

Real-time state estimation and forecasting are critical for the efficient operation of power grids. In this paper, a physics-informed Gaussian process regression (PhI-GPR) method is presented and used for forecasting and estimating the phase angle, angular speed, and wind mechanical power of a three-generator power grid system using sparse measurements. In standard data-driven Gaussian process regression (GPR), parameterized models for the prior statistics are fit by maximizing the marginal likelihood of observed data. In the PhI-GPR method, we propose to compute the prior statistics offline by solving stochastic differential equations (SDEs) governing the power grid dynamics. The short-term forecast of a power grid system dominated by wind generation is complicated by the stochastic nature of the wind and the resulting uncertainty in wind mechanical power. Here, we assume that the power grid dynamics are governed by swing equations, with the wind mechanical power fluctuating randomly in time. We solve these equations for the mean and covariances of the power grid states using the Monte Carlo simulation method. We demonstrate that the proposed PhI-GPR method can accurately forecast and estimate observed and unobserved states. For the considered problem, PhI-GPR has computational advantages over the ensemble Kalman filter (EnKF) method: In PhI-GPR, ensembles are computed offline and independently of the data acquisition process, whereas for EnFK, ensembles are computed online with data acquisition, rendering real-time forecast more challenging. We also demonstrate that the PhI-GPR forecast is more accurate than the EnKF forecast when the random mechanical wind power is non-Markovian. In contrast, the two methods produce similar forecasts for the Markovian mechanical wind power. For observed states, we show that PhI-GPR provides a forecast comparable to the standard data-driven GPR; both forecasts are significantly more accurate than the autoregressive integrated moving average (ARIMA) forecast. We also show that the ARIMA forecast is more sensitive to observation frequency and measurement errors than the PhI-GPR forecast.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A novel large-scale EV charging scheduling algorithm considering V2G and reactive power management based on ADMM

Electric vehicle aggregators (EVAs) that utilize vehicle-to-grid (V2G) technologies can function as both controllable loads and virtual power plants, providing key energy management services to the distribution system operator (DSO). EVAs can also balance the grid’s reactive power as a virtual static VAR compensator (SVC) and provide voltage stability by utilizing advanced electric vehicle (EV) chargers that are capable of four-quadrant operations to provide reactive power management. Finally, managed charging can benefit EVAs themselves by minimizing power factor penalties in their electricity bills. In this paper, we propose a novel EV charging scheduling algorithm based on a hierarchical distributed optimization framework that minimizes peak load and provides reactive power compensation for the DSO by collaboration with EVAs that manage both the active and the reactive charging and discharging power of participating EVs. Utilizing the alternative direction method of multipliers (ADMM), the proposed distributed optimization approach scales well with increased EV charging infrastructure by balancing active and reactive power while decreasing computational burden. In our proposed hierarchical approach, each EVA schedules the active and reactive EV charging and discharging power for 1) reactive power compensation in order to minimize power factor penalty and electricity cost accrued by the EVA, 2) satisfaction of each EV’s energy demand at minimal charging cost, and 3) peak shaving and load management for the DSO. When compared with an uncoordinated charging model, the efficacy of this proposed model is successfully demonstrated through a 300% decreased peak EV load for the DSO, 28% lower electricity costs for EV users, and 98.55% smaller power factor penalty, along with 17.58% lower overall electricity costs, for EVAs. The performance of our approach is validated in a case study with 50 EVs at multiple EVAs in an IEEE 13-bus test case and compared the results with uncoordinated EV charging.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Digital Real-Time Simulation and Power Quality Analysis of a Hydrogen-Generating Nuclear-Renewable Integrated Energy System

This paper investigates the challenges and solutions associated with integrating a hydrogen-generating nuclear-renewable integrated energy system (NR-IES) under a transactive energy framework. The proposed system directs excess nuclear power to hydrogen production during periods of low grid demand while utilizing renewables to maintain grid stability. Using digital real-time simulation (DRTS) in the Typhoon HIL 404 model, the dynamic interactions between nuclear power plants, electrolyzers, and power grids are analyzed to mitigate issues such as harmonic distortion, power quality degradation, and low power factor caused by large non-linear loads. A three-phase power conversion system is modeled using the Typhoon HIL 404 model and includes a generator, a variable load, an electrolyzer, and power filters. Active harmonic filters (AHFs) and hybrid active power filters (HAPFs) are implemented to address harmonic mitigation and reactive power compensation. The results reveal that the HAPF topology effectively balances cost efficiency and performance and significantly reduces active filter current requirements compared to AHF-only systems. During maximum electrolyzer operation at 4 MW, the grid frequency dropped below 59.3 Hz without filtering; however, the implementation of power filters successfully restored the frequency to 59.9 Hz, demonstrating its effectiveness in maintaining grid stability. Future work will focus on integrating a deep reinforcement learning (DRL) framework with real-time simulation and optimizing real-time power dispatch, thus enabling a scalable, efficient NR-IES for sustainable energy markets.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Resilience Analytics for Interdependent Power and Water Distribution Systems

The occurrence of large-scale outages in power distribution systems (PDSs) caused, for instance, by extreme weather events has raised concerns on the cascading impact of the power outages on the resilience of other critical infrastructures, including water distribution systems (WDSs), whose healthy operation highly relies on the availability of power from PDSs. Here, this paper proposes an analytics model for quantifying the interdependence between the resilience of power and water distribution systems. The proposed model first performs spatio-temporal outage analysis on the PDS and WDS to determine the PDS power serving capability and the resulting cascading impact on the WDS water serving capability during the occurrence of disruptions. The resilience interdependence is then determined by a proposed set of six metrics calculated using the power and water serving capability profiles, which trace and quantify the cascading impacts of power outages in the operation of WDSs during the degradation and recovery stages. The proposed analytics model is implemented on the IEEE 33-bus power distribution system supplying power for pumping stations of a 15-node test WDS, considering multiple cases of water storage capacity, single and multiple outage scenarios, and availability of distributed generation. The numerical results demonstrate that the proposed metrics track the temporal and spatial interdependence between the resilience of power and water distribution systems, providing a mechanism to identify weak spots, and assess options to enhance the resilience of the critical water infrastructure.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Optimizing the physical design and layout of a resilient wind, solar, and storage hybrid power plant

We report as wind and solar technologies improve and their costs decrease, the share of power produced by these sources will increase. As the market penetration increases, these power sources will need to provide grid services, such as dispatchability, in addition to providing energy. One way to reduce variability, provide higher quality power to the grid, and address local grid stability issues is through colocating wind and solar power plants. In addition to operating reliably during normal operating conditions, in scenarios with high penetrations of renewable generation, it is important that these hybrid plants can withstand production disruptions and continue to supply power despite prolonged resource reduction, extreme weather events, or other disruptions. In this paper, we present a methodology to optimize a wind-solar-battery hybrid power plant down to the component level that is resilient against production disruptions and that can continually produce some minimum required power. We introduce the models and assumptions we used to simulate a hybrid power plant as well as the design variable parameterization and specific methods we used to optimize the plant. We demonstrate the performance of our method by comparing a plant optimized for different objectives, generation outage durations, minimum power requirements, and power purchase agreements. Although the plant design is sensitive to model parameters and various other assumptions, our results demonstrate some of the optimal designs that occur in different scenarios and what one should expect when designing a hybrid wind-solar-storage power plant.

14 SOLAR ENERGY↗

Highly Available Nuclear Power for Mission-Critical Applications

Some energy consumers require power on an anytime, all-year-round basis with a high level of certainty, including defense installations, isolated communities, and some industrial processes. For these customers, interruptions in electricity or heat can mean substantial financial loss or even loss of life. In the absence of grid-scale energy storage, a high level of power availability can be accomplished only through the robustness and redundancy of power generators. The NuScale small modular reactor design is well suited to provide highly available power because of several features related to both the nuclear steam supply system and the overall plant design. In analogy to Redundant Array of Independent Disks (RAID) systems used to provide highly reliable data storage, a NuScale plant can assure sustained power generation by virtue of its Redundant Array of Integral Reactors (RAIR).This paper describes the NuScale RAIR plant features and summarizes the results of a rigorous analysis of RAIR availability as a function of power or, conversely, the RAIR plant output power as a function of power availability. The analysis utilized the Matrix Laboratory code (MATLAB) and included probability distributions for the frequency and duration of module outages due to planned and unplanned events. Further, the study evaluated the impact of implementing turbine bypass rather than module shutdown and using one or more modules to supply house loads in the case of loss of off-site power (LOOP). Availability results are presented for a 12-module RAIR plant with and without turbine bypass enabled during a LOOP and for different possible connections to the off-site power distribution grid and dedicated service loads. Results indicate that a very high level of availability can be achieved at relatively high power output levels, regardless of turbine bypass and dedicated load connection, compared to the operating fleet.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A 194nW Energy-Performance-Aware loT SoC Employing a 5.2nW 92.6% Peak Efficiency Power Management Unit for System Performance Scaling, Fast DVFS and Energy Minimization

A self-powered IoT system-on-chip (SoC) reduces power to sub-μw and employs multiple power-management techniques to trade-off ultra-low power (ULP), higher performance, smaller energy harvester footprint, and longer operating lifetime. Minimum Energy Point Tracking (MEPT) [1]–[4] keeps an SoC operating at the minimum energy point (MEP) to enhance system lifetime. Previous sample-and-hold MEPT schemes need frequent voltage comparisons and a high-frequency clock that increases power [2]. Current-ratio-based MEPT relies on specialized CMOS technology for body-bias tuning [3]. A switched-capacitor-based MEPT can achieve energy minimization at a targeted performance [4], but it uses a 30MHz clock witμW power consumption and low power efficiency. For ULP IoT applications, SoCs need to have ultra-low quiescent power, high efficiency for energy delivery, performance scaling based on available energy, and energy minimization to increase system lifetime. In this work, we propose an ULP IoT SoC with a triple-mode power management unit (PMU) that integrates energy-performance scaling, event-driven fast DVFS, and MEPT features to improve the system energy efficiency, as shown in Fig. 13.8.1. This work achieves a minimum 194nW power consumption for the SoC and 5.2nW quiescent power for the PMU with a 92.6% peak efficiency and >10 4 dynamic range. The timing waveform in Fig. 13.8.1 (bottom), demonstrates the transition of the three modes including energy aware (EA), performance aware (PA), and MEPT based on event priority and input voltage level which reflects the energy availability. As such, the system energy consumption and performance could be well-balanced based on both the input and output conditions.

self-powered IoT system-on-chip (SoC)↗

Multiphysics Co-Optimization Design and Analysis of Double-Side Cooled Silicon Carbide-Based Power Module: Preprint

With the rapid growth of Electric Vehicles (EVs) and Hybrid Electric Vehicles (HEVs), much more rigorous design targets have been set for automotive power electronics, including high power density, high reliability, and low cost. Novel power module and inverter technologies based on wide bandgap (WEG) semiconductors have been developed to meet these design targets, while providing optimal power semiconductor operating temperature and promising thermomechanical performance. Compared with conventional cooling techniques which are normally applied only on one side of power module, double-side cooling approach is now believed to be the solution to enable high power density and low thermal resistance of WEG semiconductor-based power electronics. In this work, we develop a three-phase power module that is double-sided cooled using dielectric fluid jet impingement. In each phase, four silicon carbide (SiC) power semiconductors are bonded to copper busbars without electrical insulation layers. A finite element analysis (FEA) model is created for thermal and thermomechanical analysis. Based on FEA modeling results, we select particular dimensions for a parametric study to optimize thermal and mechanical performance. Using a multi-objective genetic algorithm (MOGA)-based optimization method, we have minimized the maximum junction temperature and thermal stresses within the power module. The multiphysics co-optimization approach has enabled an efficient design process of power modules with greatly reduced computational cost, as compared to conventional processes that rely on exhaustive numerical simulations and iterations.

ADVANCED PROPULSION SYSTEMS↗

ReNew100: Reliable Power System Operation with 100% Renewable Generation

The ReNew100 project has developed and demonstrated an operator support system (OSS) to operate power systems with 100% renewable power generation from inverter-based resources (IBRs) like wind and solar that significantly reduces the risk of widespread power outages in a simulated operational environment at Technology Readiness Level (TRL) 6. The OSS achieves resilient operation for power systems under changing operation modes including varying combinations of conventional and renewable generation, including cases with 100% renewable generation from wind and solar IBRs. The OSS continuously monitors the N-1 security of the power system, which refers to the ability of the power systems to survive single outages of power system elements, like the loss of a generator or a power line, without causing widespread power outages beyond those expected and planned for. If the OSS identifies that the system is not N-1 secure, an automatic Controller Parameter Optimization (CoPO) developed within Renew100 is activated to optimize the N-1 security of the system by tuning controller parameters within different assets like batteries, wind, and solar plants. The core innovation of ReNew100 is the development of this CoPO as well as the demonstration of the OSS for a real-time simulation of the Hawai'i Island power system. Moreover, Renew100 has developed new model calibration techniques for dynamic power system models and demonstrated them for Hawai'i Island.

24 POWER TRANSMISSION AND DISTRIBUTION↗