Search NASA⌕ Search

SEARCH · Search NASA

Results for “prepreg”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Undirectional Carbon Nanotube Yarn/Polymer Composites

Carbon nanotubes (CNTs) are one-dimensional nanomaterials with outstanding electrical and thermal conductivities and mechanical properties at the nanoscale. With these superior physical properties, CNTs are very attractive materials for future light weight structural aerospace applications. Recent manufacturing advances have led to the availability of bulk formats of CNTs such as yarns, tapes, and sheets in commercial quantities, thus enabling the development of macroscale composite processing methods for aerospace applications. The fabrication of unidirectional CNT yarn/polymer composites and the effect of processing parameters such as resin type, number of CNT yarn layers, CNT yarn/resin ratio, consolidation method, and tension applied during CNT yarn winding on the mechanical properties of unidirectional CNT yarn composites are reported herein. Structural morphologies, electrical and thermal conductivities, and mechanical performance of unidirectional CNT yarn/polymer composites under tensile and short beam shear loads are presented and discussed. The application of higher tension during the winding process and elevated cure pressure during the press molding step afforded a compact structural morphology and reduced void content in the composite. However, the composite tensile strength was negligibly impacted by the fabrication parameters, such as cure pressure, winding tension, and resin chemistry, excepting resin content and number of CNT yarn layers. The tension winding method produced better quality and lower resin content CNT yarn composites compared to conventional prepregging methods, resulting in higher specific strength and modulus of the composites. The specific tensile strength of the CNT composite was approximately 69 % of the starting CNT yarn. Electrical and thermal conductivities of unidirectional CNT yarn/polymer composites were in the range of 1000 to 12000 S/cm and 22 to 45 W/mK, respectively.

Kim, Jae-Woo↗

Polymer Matrix Composites Fabrication and Testing

This project involves two separate processes for fabricating carbon fiber composite parts using Hexcel’s RTM6 resin system and Kaneka’s IR-6070 toughened resin system to impregnate carbon fiber tow and weave. These two resins were chosen to model microcracking in parts using RTM6 compared to parts using IR-6070. Plies of the composites were made by painting resin onto 8 harness satin weave or impregnating IM7 12k tow in a prepregging machine. Plies were consolidated using an out-of-autoclave oven or a heat press. Fabrication of the composite parts were conducted with the end goal of sending the composites to be tested and modeled for microcracking. The data will be used for computer modeling in the future.

Miller, Sandi↗

A Design Methodology for Optimizing and Integrating Composite Materials in Gear Structures

The application of composite materials to gear structures is complex because of the gear shape, the need for precise dimensional tolerances, and the complex dynamic load condition. Methods are presented in this work to design and optimize an integrated composite hub-web structure that can be used as part of a hybrid composite-steel gear. The composite hub-web structure is a planar structure with a large decrease in thickness from the hub to the rim. Methods for design and optimization of this variable-thickness structure are presented along with a method for forming braided prepreg material to conform to the shape of this structure. A layered approach is presented that integrates cut plies or filler materials for thickness buildup with continuous-fiber layers for the primary load path. An additional gear design concept is presented that has an axially extended continuous-fiber composite structure that can be combined with the planar structure. A proposed optimization methodology is introduced where an optimized design is output for each type of optimization simulation. Through this process, composite knowledge can be incorporated in the optimization, and more control is given over the design during the process. The methods in this study provide a tool for designing and optimizing composite structures for gears and other high-power-density applications.

optimization↗

Preliminary Nonlinear Structural Analysis of Advanced Composite Tow-Steered Shells with Large Geometric Imperfections

The structural performance of two advanced composite tow-steered shells with and without tow overlaps, and with large geometric imperfections, are predicted using linear and geometrically nonlinear finite element analyses. These shells, 35 in. long and approximately 16.3 in. diameter, are fabricated using automated fiber placement from IM7/8552 graphite/epoxy prepreg. The 8-ply,[±45/±Θ]s. shell layup incorporates a steered fiber angle Θ that varies from 10 deg. to 45 deg. periodically over the shell circumference. Shell analysis models are evaluated using geometric imperfections normalized to ±1 shell wall thickness (±0.040 in.), which are then superposed and rotated incrementally around the shell longitudinal axis. Using these nominal imperfections, the shell prebuckling axial stiffnesses and buckling loads predicted with linear and nonlinear analyses are close to reference values from linear analyses with no imperfections. The linear and nonlinear analyses are then repeated for scaled imperfections that are larger by up to a factor of 10. For these larger imperfections, linear analyses predict reductions in axial stiffnesses and buckling loads of up to 5 and 30 percent, respectively, from reference values. The nonlinear analyses predict even larger reductions in axial stiffnesses and buckling loads of up to 10 and 55 percent, respectively.

Dobrin, Calvin P.↗

Evaluation of Temperature Gradients During Cure of a Thick Carbon Fiber/Epoxy Composite

The purpose of this study is to evaluate the development of thermal gradients throughout thick (1") carbon fiber composites and determine the effect of internal temperature distribution during cure on the observed mechanical properties in those composites. Composites up to 1.5" thick (56 plies) were fabricated with T700S/TC380 braided prepreg from Tencate following a modified vacuum bag layup procedure to include embedded thermocouples within the plies of the composite. Composite panels were cured in a programmable oven with thermocouple reading embedded throughout the panel thickness. Maximum temperature gradients measured between regions of the composite did not exceed 10 degrees C for any given composite thickness. The most significant temperature variation was measured between the mid-thickness plies and the tool-side surface plies. Although through thickness temperature variation during cure was small, a measureable variation in coupon glass transition temperature was recorded between the tool side plies and the remainder of the part, prior to post cure. Thermal and mechanical behavior of coupons taken from segments through the thickness of the part were comparable following a post-cure cycle.

Miller, Sandi↗

In Situ Thermal Inspection of Automated Fiber Placement Operations for Tow and Ply Defect Detection

The advent of Automated Fiber Placement (AFP) systems have aided the rapid manufacturing of composite aerospace structures. One of the challenges that AFP systems pose is the uniformity of the deposited prepreg tape layers, which complicates detection of laps, gaps, overlaps and twists. The current detection method used in industry involves halting fabrication and performing a time consuming, visual inspection of each tape layer. Typical AFP systems use a quartz lamp to heat the base layer to make the surface tacky as it deposits another tape layer. The innovation proposed in this paper is to use the preheated base layer as a through-transmission heat source for inspecting the newly added tape layer in situ using a thermographic camera mounted on to the AFP hardware. Such a system would not only increase manufacturing throughput by reducing inspection times, but it would also aid in process development for new structural designs or material systems by providing data on as-built parts. To this end, a small thermal camera was mounted onto an AFP robotic research platform at NASA, and thermal data was collected during typical and experimental layup operations. The data was post processed to reveal defects such as tow overlap/gap, wrinkling, and peel-up. Defects that would have been impossible to detect visually were also discovered in the data, such as poor/loss of adhesion between plies and the effects of vacuum debulking. This paper will cover the results of our experiments, and the plans for future versions of this inspection system.

Juarez, Peter D.↗

Assessment of Automated Fiber Placement for the Fabrication of Composite Wind Tunnel Blades

Composite wind tunnel blades are frequently fabricated by hand layup of prepreg fabrics. Though well proven, this fabrication method is laborious and expensive. The study described in this paper used the Integrated Structural Assembly of Advanced Composites (ISAAC) facility at the NASA Langley Research Center to explore whether automated fiber placement (AFP) could reduce manufacturing time and cost for production of wind tunnel blades. Two blades, taken from two NASA wind tunnels, were investigated as representative geometries. Computer-aided design models of the blade surfaces were created, and AFP process planning and programming were employed to study the manufacturability of the shapes. A placement/cure tool was manufactured for the chosen blade surface from thermoplastic material using an additive manufacturing process. The present study revealed that the AFP head geometry, primarily the heater configuration of the ISAAC system, is the primary constraint that limits the ability to manufacture the selected wind tunnel fan blades using AFP.

Grenoble, Ray↗

Reliable Bonding of Composite Laminates Using Reflowable Epoxy Resins

Epoxy matrix composites assembled with adhesives maximize the performance of aerospace structures, but the possibility of forming weak bonds requires the installation of redundant fasteners, which add weight and manufacturing cost. Co-cured joints (e.g. unitized composite structures) are immune to weak bonds because the uncured resin undergoes diffusion and mixing through the joint. A means of co-curing complex structures may reduce the need for redundant fasteners in bondlines. To this end, NASA started the AERoBOND project to develop novel joining materials to enable a “secondary-co-cure” assembly process. Aerospace epoxy resin systems reformulated with offset stoichiometry prevented the resin from advancing beyond the gel point during a conventional autoclave cure cycle up to 180 °C. The offset resins were applied to the joining surfaces of laminate preforms as prepreg. Two surfaces with complimentary offset resins were joined using conventional secondary bonding techniques. Preliminary efforts have indicated that the resulting joint has no discernable interface and appears as a conventional co-cured laminate under optical magnification. This report will discuss the initial work performed regarding formulation of the epoxy resin system using calorimetry, rheology, and mechanical testing.

Palmieri, Frank L.↗

TPSAS-NF1676L-10936-DND

The current manufacturing process for fiber metal laminates (FML) requires prepreg and an autoclave or press, the part size is limited by the size of the autoclave or press, and the process is expensive. The objective is to reduce the cost of fiber metal laminates by manufacturing by the VARTM process with an ultimate goal of producing FML with the level of quality comparable to those of FML fabricated by autoclave.

Brian J Jensen↗

TPSAS-NF1676L-13555-DND

A sub-scale advanced composite shell design is evaluated to determine its potential for use on a future aircraft fuselage. Two composite shells with the same nominal 8-ply [?45/?]s layup are evaluated, where ? indicates a tow-steered ply. To build this shell, a fiber placement machine is used to steer unidirectional prepreg tows as they are placed around the circumference of a 17-inch diameter right circular cylinder. The fiber orientation angle varies continuously from 10 degrees (with respect to the shell axis of revolution) at the crown, to 45 degrees on the side, and back to 10 degrees on the keel. All 24 tows are placed at each point on every fiber path in one structure designated as the shell with overlaps. The resulting pattern of tow overlaps causes the laminate thickness to vary between 8 and 16 plies. The second shell without tow overlaps uses the capability of the fiber placement machine to cut and add tows at any point along the fiber paths to fabricate a shell with a nearly uniform 8-ply laminate thickness. Static stiffness and buckling loads of shells with tow-steered layups are compared with the performance of a baseline quasi-isotropic shell using both finite element analyses and classical strength of materials theory. These tailored, tow-steered shells were then were designed and built at the National Center for Advanced Manufacturing - Louisiana Partnership under a joint NASA-industry collaborative effort. The shells were fabricated from unidirectional IM7/8552 graphite-epoxy pre-preg slit tape material placed on a constant-diameter mandrel. An overview of the detailed design and manufacturing processes for these shells is presented, and issues encountered during their design, analysis, fabrication and post-cure evaluation are presented and discussed. Future plans for structural testing and analyses of the shells are also discussed.

K Chauncey Wu↗

In-Situ Detection of Process-Induced Porosity During Cure of Out-of-Autoclave Composites

Composite materials offer unique benefits in aerospace applications, including high strength-to-weight ratio, and are becoming increasingly used by industry manufacturers. Current manufacturing and processing methods can lead to defects in the composites, which are identified after fabrication using inspection methods. This study utilized a high-temperature ultrasonic inspection system to detect process-induced porosity in an out-of-autoclave (OOA) composite panel during cure. In order to perform ultrasonic scans in-situ during cure, the system needed to be able to operate at oven temperatures up to 200 °C. There are no commercially available ultrasonic scanning systems that can operate continuously at these temperatures, so an enclosure was fabricated to insulate the ultrasonic system in the curing oven. The enclosure housed a MISTRAS® motorized X-Y raster scanner and contact transducer (Olympus® X2002). The Olympus® X2002 contact transducer is a continuous high-temperature delay line transducer with a center frequency of 2.25 MHz. In order to prevent the inside of the enclosure from reaching high temperatures, a sparge pipe inside the cooling enclosure was connected to a liquid nitrogen (LN2) tank outside of the oven via insulated hoses. The cooling system was automatically controlled by a temperature controller that was programmed to open a solenoid valve along the hose at 31 ℃ and close at 28 ℃ inside the cooling enclosure. When the solenoid valve was open, LN2 would flow from the LN2 tank and vaporize prior to reaching cooling enclosure. A U-shaped sparge pipe had holes drilled along its length to uniformly introduce cold nitrogen gas into the cooling enclosure. This prevented the motors from ever reaching the maximum desired operating temperature of 38 ℃. In the bottom of the enclosure, the tool plate was placed with the composite facing the outside of the enclosure, exposing it to the temperatures of the oven. The tool plate was 63.5 mm thick borosilicate glass, which was chosen for its low ultrasonic attenuation and moderate thermal conductivity. A thin layer of ultrasonic couplant was placed on the tool plate. The transducer sent and received ultrasonic waves through the tool plate into the composite. A MISTRAS® Remote UT System performed all wave generation, analog to digital conversion, and data acquisition and processing. The transducer was connected directly to the Remote UT System via a high-temperature BNC cable (CD International, RG-316). Polyimide insulated copper wire was used to connect the scanner to a 2-axis motor drive, which was connected to the Remote UT System. The motor drive and Remote UT System were located outside the industrial oven. A diagram of the ultrasonic system is shown in Figure 1. Figure 1: Diagram of ultrasonic in-situ defect detection system. In this study, a porosity gradient was introduced into the carbon fiber reinforced polymer (CFRP) composite through a misfit of the part and caul plate. A 24-ply quasi-isotropic ([0/90, ±45]12S) composite panel was laid up using Newport® AS4C-M/NB321 out-of-autoclave (OOA) plain weave (PW) prepreg (42% resin content, 195 g/m2). The first 16 plies were 203 mm × 203 mm. Ply drops were incorporated into the panel by decreasing the length of plies 17-24. The sizes of each ply are included in Table 1. All plies were centered along their length (x-axis) creating a trapezoidal type cross-section. Table 1: Ply sizes Plies Length (mm) Width (mm) 1-16 203 203 17-18 102 203 19-20 85 203 21-22 68 203 23-24 51 203 A 15-5 stainless steel caul plate (Size: 203 × 203 × 1.2 mm) was placed on the laminate. The composite and caul plate were vacuum bagged to the tool plate. Per the product datasheet, Newport 321 can be cured between 121 °C and 149 °C, depending on service temperature, with a hold for 90-120 minutes. Based on prior thermal testing of the cooling enclosure, the desired composite temperature cycle could be attained when the air temperature of the oven was ramped to 160 °C at a rate of 1.7 °C/min with a 3 hour hold. The extended hold was not necessary to cure the composite, but did allow for additional scans at the cure temperature during preliminary testing. The composite panel was under vacuum pressure for the entire cure cycle. Under vacuum, the caul plate deformed causing high and low pressure regions. The low-pressure regions formed high porosity in the composite part. The ultrasonic data collected showed that the inspection system was able to monitor the evolution of porosity within the composite throughout the cure cycle. Fifty scans of a 203 mm × 51 mm (8 in. × 2 in.) area of the composite were completed throughout the cure cycle. The scan speed was set to 43 mm/s in the x-direction and 36 mm/s in the y-direction, with a 1.0 mm/pixel resolution in both directions. Each scan took approximately five minutes to complete. Figure 2 shows C-scan amplitude data (top view) from one scan during the cure cycle. The color map indicates the maximum amplitude (%) measured with a time gate that contains reflections from the back surface (furthest from the transducer in contact with the caul plate) of the composite. Because porosity in the composite increases the ultrasonic attenuation in the composite part, a higher amplitude (red) indicates low porosity and a lower amplitude (blue) indicates high porosity. The regions where the caul plate was applying increased pressure (center and ends of the panel) resulted in reduced porosity, whereas the ply drop regions had reduced pressure and thus had higher porosity. Figure 2: Amplitude C-scan (top view) of OOA composite from one scan during the 160 °C temperature hold. Higher amplitude (red) indicates low porosity. Lower amplitude (blue) indicates high porosity. A B-scan is a two-dimensional image plotting the ultrasonic signals from a single y-position at every x-location of the composite panel. The travel time (μs) of the ultrasonic wave (representing the through-thickness location) is plotted along the y-axis, and the ultrasonic wave signal is represented as a contour map. Based on the B-scan data, the location of the defects with respect to the composite thickness was able to be determined. The ply drop regions had high porosity near the front (tool plate) surface of the composite (Figure 3). Figure 3: B-scan (cross-section view) of OOA composite from one scan during the 160 °C temperature hold. Using the data obtained from amplitude C-scans and B-scans throughout the cure cycle, the high and low porosity regions within the composite laminate were detected and localized with high spatial resolution. This paper will discuss the evolution of porosity content in the OOA composite during cure. OOA tests aided the transition of this system to an autoclave, which is the primary method of curing aerospace-grade thermoset composites.

Tyler B. Hudson↗

Design, Fabrication and Testing of 30-cm Dia. Dished Carbon-Carbon Ion Engine Grids

Two sets of 30-cm dia. dished carbon-carbon ion engine grid sets were fabricated, assembled and tested. The carbon-carbon grid blanks were fabricated from unidirectional prepreg tape, having a very high fiber volume fraction of 57 percent and resulting in the strongest quasi-isotropic carbon-carbon material known to the authors. The flexural modulus of the panel material was measured at 275 MPa, corresponding to 80 percent of the value of molybdenum.

ion↗

Manufacturing and Mechanical Testing of TC1225/LM-PAEK and TC1200/PEEK Thermoplastic Composite Panels

Development of thermoplastic composites (TPCs) for aerospace structures is experiencing renewed enthusiasm attributed to the availability of rapid manufacturing technology, ease of joining through fusion welding processes, and the successful utilization of the material in flight critical structures. Semicrystalline thermoplastics such as polyether ether ketone (PEEK), polyether ketone ketone (PEKK), and polyphenylene sulfide (PPS) have been successfully demonstrated as thermoplastic skins, keel beams, and angle brackets for commercial aircraft. Composite specimens were fabricated from the Toray TC1225 and TC1200 unidirectional prepreg systems and tested to gain confidence with NASA in-house TPC processing as part of the Thermoplastics Development for Exploration Application (TDEA) project. TC1225 is a relatively new material system that uses T700GC fibers and low-melt polyaryl ether ketone (LM-PAEK) resin. TC1200 is the latest version of a material system that has been available for several decades with AS4 fibers and PEEK resin. Results for ultrasonic inspection, optical microscopy, acid digestion, and differential scanning calorimetry establish the quality of the panels. Mechanical test data for unnotched and notched laminate tension and compression as well as compression after impact provide data for equivalency assessment and support material selection in TDEA. Satisfactory equivalence of the TC1225 results and the National Center for Advanced Materials Performance (NCAMP) database was found. The results indicate high-quality manufacturing was achieved, and the resulting mechanical test data are in agreement with that in the literature.

Thermoplastic Composites↗

Dynamic Crush Performance of Thermoplastic and Resin Infused Thermoset Triaxially Braided Composite Structures

Dynamic crush tests were conducted on triaxially braided composite tubes and C-channel structural elements to measure their relative energy absorbing characteristics. The elements were manufactured from triaxially braided [0/+60/-60] T700 fiber preforms with two different resin systems, a PR520 thermoset resin and a LM-PAEK thermoplastic resin. T700/PR520 composite tubes and C-channel elements were manufactured using a resin infusion process. T700GC/LMPAEK composite tubes were manufactured by braiding slit tape prepreg onto cylindrical mandrels. Consolidation pressure was applied through thermally activated shrink tape in an oven. The energy absorbing characteristics of the composite elements were measured using a pneumatically actuated sled with a flat-faced impacting mass, which provided several independent measurements of force, displacement, and energy absorption. The parameter primarily used for comparison between the systems was the specific energy absorption (SEA), a measure of energy absorbed per unit crushed length. The T700/LMPAEK tubes performed slightly better than T700/PR520 tubes, with an approximately 9% higher SEA. T700/PR520 tubes had over 20% higher SEA than C-channels made from the same material. Additional tests were conducted on tubes using a tapered-conical impactor to force the tubes to fail in circumferential tension. This type of impact significantly reduced the energy absorption.

Composite Materials↗

Dynamic Crush Performance of Thermoplastic and Resin Infused Thermoset Triaxially Braided Composite Structures

Dynamic crush tests were conducted on triaxially braided composite tubes and C-channel structural elements to measure their relative energy absorbing characteristics. The elements were manufactured from triaxially braided [0/+60/-60] T700 fiber preforms with two different resin systems, a PR520 thermoset resin and a LM-PAEK thermoplastic resin. T700/PR520 composite tubes and C-channel elements were manufactured using a resin infusion process. T700GC/LMPAEK composite tubes were manufactured by braiding slit tape prepreg onto cylindrical mandrels. Consolidation pressure was applied through thermally activated shrink tape in an oven. The energy absorbing characteristics of the composite elements were measured using a pneumatically actuated sled with a flat-faced impacting mass, which provided several independent measurements of force, displacement, and energy absorption. The parameter primarily used for comparison between the systems was the specific energy absorption (SEA), a measure of energy absorbed per unit crushed length. The T700/LMPAEK tubes performed slightly better than T700/PR520 tubes, with an approximately 9% higher SEA. T700/PR520 tubes had over 20% higher SEA than C-channels made from the same material. Additional tests were conducted on tubes using a tapered-conical impactor to force the tubes to fail in circumferential tension. This type of impact significantly reduced the energy absorption.

Composite Materials↗

Tensile Behavior and High-Cycle Fatigue Durability of a SiC/SiC Ceramic-Matrix Composite Without and With Simulated Cooling Holes

High-cycle fatigue (HCF) behavior of a melt-infiltrated, prepreg SiC/SiC composite was investigated using specimens without and with simulated cooling holes at 816 and 1,316 °C. The ceramic-matrix composite (CMC) material used for this study was fabricated by GE Aviation and had a ply configuration of [0/90/0] 3 . HCF tests were conducted with an R-ratio of 0.6 and a cyclic frequency of 30 Hz. Maximum tensile gross-section stresses used in the HCF tests ranged from 152 to 359 MPa. Runout in HCF was defined as 30 million cycles (278 h) at both temperatures. Monotonic tensile tests were conducted at room temperature (RT) on as-received CMC specimens and on HCF runout specimens without and with holes to determine residual tensile strengths. Digital image correlation (DIC) and acoustic emission (AE) techniques were used to monitor progression of damage in RT tensile tests on specimens without and with holes. Fractography was performed on a limited number of specimens without and with holes to determine morphology of fracture surfaces. Representative RT stress-strain behavior, elevated temperature HCF behavior at the two temperatures, and RT residual tensile strengths of HCF runout specimens are documented in this report. Select examples of DIC and AE data from RT tensile tests on specimens without and with holes and typical features observed on fracture surfaces of specimens tested under tensile and HCF conditions are also discussed.

Ceramic matrix composite↗

Thermal Conductivity and Mechanical Properties of Epoxy Composites With Hybridized PAN- and Pitch-Based Fiber Architecture

A series of hybrid polyacrylonitrile- (PAN-) and pitch-based carbon fiber/epoxy composites were fabricated and tested to evaluate the influence of hybrid fiber configurations on composite strength, modulus, and through-thickness thermal conductivity. Two grades of pitch-based fiber were selected based on their thermal conductivity: YSH-60A and YSH-80A from Nippon Graphite. These pitch-based fibers were received in tow form and as plain weave to allow flexibility in the architecture of the multifiber laminate. Two hybridization approaches were followed: (1) interleave of pitch-based fiber weave within braided PAN/epoxy prepreg and (2) incorporation of pitch-based fiber tows within a three-dimensional braided preform. These showed considerable impact on overall composite mechanical properties and through-thickness thermal conductivity.

Polymer Composite↗

Flexural Fatigue Testing and Qualification of Hybrid PAN-pitch Composite Materials with High Through-Thickness Thermal Conductivity

Carbon-fiber-reinforced polymers (CFRPs) considered for motor components within future electric vertical takeoff and landing (eVTOL) vehicles require not only a high strength-to-weight ratio but also a high through-thickness thermal conductivity (TC) to dissipate heat. Previously, CFRPs incorporating pitch CF interleaves demonstrated an increased through-thickness TC relative to the baseline composite, but the effect on flexural fatigue life was not evaluated. For this work, T700S/TC275–1 braided carbon fiber/epoxy prepreg baseline (no interleave), YSH–60A pitch interleave, and YS–80A pitch interleave configurations were tested for fatigue life. A combination of ASTM International Standards D7264 and D3479 were used to develop a reliable testing method. An Instron® (Illinois Tool Works Inc.) 8501 servohydraulic system with a fatigue test fixture was set up with a 16:1 span:thickness ratio, load ratio R set to 0.1, and frequency of 4 Hz. High-cycle fatigue testing was completed, and it was found that YSH–60A interleave performed slightly better than YS–80A below 100,000 cycles but showed no differences above 100,000 cycles. In all cases, the baseline CFRP had superior fatigue life performance both in terms of stress handled and total cycles to failure. These fatigue testing data will inform future use of hybrid CFRP materials by highlighting the tradeoff between increased through-thickness TC and fatigue life. Testing guidelines, equipment, and parameters for static and fatigue tests were successfully outlined for CFRPs.

composites↗