Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantum image processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Exclusive QCD Factorization and Single Transverse Polarization Phenomena at High-Energy Colliders

This Ph.D. thesis is divided into two distinct parts. The first part focuses on hard exclusive scattering processes in Quantum Chromodynamics (QCD) at high energies, while the second part delves into spin phenomena at the Large Hadron Collider (LHC). Hard exclusive scattering processes play a crucial role in QCD at high energies, providing unique insights into the confined partonic dynamics within hadrons, complementing inclusive processes. Studying these processes within the QCD factorization approach yields the generalized parton distribution (GPD), a nonperturbative parton correlation function that offers a three-dimensional tomographic parton image within a hadron. However, the experimental measurement of these processes poses significant challenges. This thesis will review the factorization formalism for related processes, examine the limitations of some widely used processes, and introduce two novel processes that enhance the sensitivity to GPD, particularly its dependence on the parton momentum fraction x. The second part of the thesis centers on spin phenomena, specifically single spin production, at the LHC. Noting that a single transverse polarization can be generated even in an unpolarized collision, this research proposes two new jet substructure observables: one for boosted top quark jets and another for high-energy gluon jets. The observation of these phenomena paves the way for innovative tools in LHC phenomenology, enabling both precision measurements and the search for new physics.

Yu, Zhite↗

Diode-based additive manufacturing of metals using an optically-addressable light valve

We present that Selective Laser Melting (SLM) of metal powder bed layers, whereby 3D metal objects can be printed from a digital file with unprecedented design flexibility, is spurring manufacturing innovations in medical, automotive, aerospace and textile industries. Because SLM is based on raster-scanning a laser beam over each layer, the process is relatively slow compared to most traditional manufacturing methods (hours to days), thus limiting wider spread use. Here we demonstrate the use of a large area, photolithographic method for 3D metal printing, using an optically-addressable light valve (OALV) as the photomask, to print entire layers of metal powder at once. An optical sheet of multiplexed ~5 kW, 20 ms laser diode and ~1 MW, 7 ns Q-switched laser pulses are used to selectively melt each layer. Finally, the patterning of near infrared light is accomplished by imaging 470 nm light onto the transmissive OALV, which consists of polarization-selective nematic liquid crystal sandwiched between a photoconductor and transparent conductor for switching.

36 MATERIALS SCIENCE↗

Evaluating the solution from MrBUMP and BALBES

The automated pipelines for molecular replacement MrBUMP and BALBES are reviewed, with an emphasis on understanding their output. Conclusions are drawn from their performance in extensive trials. Molecular replacement is one of the key methods used to solve the problem of determining the phases of structure factors in protein structure solution from X-ray image diffraction data. Its success rate has been steadily improving with the development of improved software methods and the increasing number of structures available in the PDB for use as search models. Despite this, in cases where there is low sequence identity between the target-structure sequence and that of its set of possible homologues it can be a difficult and time-consuming chore to isolate and prepare the best search model for molecular replacement. MrBUMP and BALBES are two recent developments from CCP4 that have been designed to automate and speed up the process of determining and preparing the best search models and putting them through molecular replacement. Their intention is to provide the user with a broad set of results using many search models and to highlight the best of these for further processing. An overview of both programs is presented along with a description of how best to use them, citing case studies and the results of large-scale testing of the software.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-I-92: Is Photon Starvation Preventing Metal Artifact Reduction Algorithm From Working in KVCT?

Purpose: High density/high atomic number metallic objects create shading and streaking metal artifacts in the CT image that can cause inaccurate delineation of anatomical structures or inaccurate radiation dose calculation. A modified iterative maximum-likelihood polychromatic algorithm for CT (mIMPACT) that models the energy response of detectors, photon interaction processes and beam polychromaticity has successfully reduced metal artifacts in MVCT. Our extension of mIMPACT in kVCT did not significantly reduce metal artifacts for high density metal like steel. We hypothesize that photon starvation may result in the measured data in a commercial kVCT imaging beam. Methods: We measured attenuation of a range of steel plate thicknesses, sandwiched between two 12cm thick solid water blocks, using a Phillips Big Bore CTTM scanner in scout acquisition mode with 120kVp and 200mAs. The transmitted signal (y) was normalized to the air scan signal (y{sub 0}) to get attenuation [i.e., ln(y/y{sub 0})] data for a detector. Results: Below steel plate thickness of 13.4mm, the variations in measured attenuation as a function of view number are characterized by a quantum noise and show increased attenuation with metal thickness. On or above this thickness the attenuation shows discrete levels in addition to the quantum noise. Some views have saturated attenuation value. The histograms of the measured attenuation for up to 36.7mm of steel show this trend. The detector signal is so small that the quantization levels in the analog to digital (A-to-D) converter are visible, a clear indication of photon starvation. Conclusion: Photons reaching the kVCT detector after passing through a thick metal plate are either so low in number that the signal measured has large quantum noise, or are completely absorbed inside the plate creating photon starvation. This is un-interpretable by the mIMPACT algorithm and cannot reduce metal artifacts in kVCT for certain realistic thicknesses of steel hip implants. Moti Raj Paudel is supported by the Vanier Canada Graduate Scholarship, the Endowed Graduate Scholarship in Oncology and the Dissertation Fellowship at the University of Alberta. The authors acknowledge the CIHR operating grant number MOP 53254.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra-high-precision alignment of the elastomerically mounted elements of the science camera lenses for the Mars Science Laboratory (MSL) rover

Cameras built for space exploration are required to meet stringent environmental conditions, such as thermal and dynamic loads for both the optics (camera lens) and imaging electronics. On a multitude of spaceborne imaging instruments, optical elements are supported in their mounts via an elastomeric bonding approach using a room temperature vulcanizing silicone as the bonding agent. Employing this integration method, we achieved element-to-element alignment, measured as the total indicated runout, using a high-precision contact probe to be on the order of half a wavelength of He-Ne laser light, or 0.3 {mu}m, on the Malin Space Science Systems lenses for the Mars Science Laboratory (MSL) cameras. This is a higher precision than the current industry state-of-the-art, and it was achieved for the very challenging small diameter lens elements. This paper describes the design philosophy, implementation, and integration method that resulted in achieving this level of precision for interelement alignment. The results are based on actual measurements that were made during the process of building the MSL rover's science camera lenses, namely Mastcams, the Mars Hand Lens Imager, and the Mars Descent Imager. The optical designs of these cameras lenses are described in detail in [Opt. Eng.48, 103002 (2009)10.1117/1.3251343], while further information on the four science cameras can be found at http://www.msss.com.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Highly efficient and two-photon excited stimulated Rayleigh-Bragg scattering in organic solutions

The properties of backward stimulated Rayleigh-Bragg scattering (SRBS) in three highly two-photon active AF-chromophores solutions in tetrahydrofuran (THF) have been investigated using 816-nm and 8-ns pump laser beam. The nonlinear reflectivity R, spectral structure, temporal behavior, and phase-conjugation capability of the backward SRBS output have been measured, respectively. Under the same experimental condition, the pump threshold for SRBS in three solution samples can be significantly (∼one order of magnitude) lower than that for stimulated Brillouin scattering (SBS) in the pure solvent (THF). With the optimized concentration value and at a moderate pump energy (∼1.5 mJ) level, the measured nonlinear reflectivity was R ≥ 35% for the 2 cm-long solution sample, while for the SBS from a pure solvent sample of the same length was R ≈ 4.7%. The peculiar features of very low pump threshold, no spectral shift, tolerant pump spectral linewidth requirement (≤1 cm{sup −1}), and phase-conjugation capability are favorable for those nonlinear photonics applications, such as highly efficiency phase-conjugation reflectors for high-brightness laser oscillator/amplifier systems, special imaging through turbid medium, self-adaptive remote optical sensing, as well as for optical rangefinder and lidar systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and evaluation of a device for fast multispectral time-resolved fluorescence spectroscopy and imaging

The application of time-resolved fluorescence spectroscopy (TRFS) to in vivo tissue diagnosis requires a method for fast acquisition of fluorescence decay profiles in multiple spectral bands. This study focusses on development of a clinically compatible fiber-optic based multispectral TRFS (ms-TRFS) system together with validation of its accuracy and precision for fluorescence lifetime measurements. It also presents the expansion of this technique into an imaging spectroscopy method. A tandem array of dichroic beamsplitters and filters was used to record TRFS decay profiles at four distinct spectral bands where biological tissue typically presents fluorescence emission maxima, namely, 390, 452, 542, and 629 nm. Each emission channel was temporally separated by using transmission delays through 200 μm diameter multimode optical fibers of 1, 10, 19, and 28 m lengths. A Laguerre-expansion deconvolution algorithm was used to compensate for modal dispersion inherent to large diameter optical fibers and the finite bandwidth of detectors and digitizers. The system was found to be highly efficient and fast requiring a few nano-Joule of laser pulse energy and <1 ms per point measurement, respectively, for the detection of tissue autofluorescent components. Organic and biological chromophores with lifetimes that spanned a 0.8–7 ns range were used for system validation, and the measured lifetimes from the organic fluorophores deviated by less than 10% from values reported in the literature. Multi-spectral lifetime images of organic dye solutions contained in glass capillary tubes were recorded by raster scanning the single fiber probe in a 2D plane to validate the system as an imaging tool. The lifetime measurement variability was measured indicating that the system provides reproducible results with a standard deviation smaller than 50 ps. The ms-TRFS is a compact apparatus that makes possible the fast, accurate, and precise multispectral time-resolved fluorescence lifetime measurements of low quantum efficiency sub-nanosecond fluorophores.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-F-CAMPUS-J-05: Effect of Uncorrelated Noise Texture On Computed Tomography Quantitative Image Features

Purpose: To investigate the relationship between quantitative image features (i.e. radiomics) and statistical fluctuations (i.e. electronic noise) in clinical Computed Tomography (CT) using the standardized American College of Radiology (ACR) CT accreditation phantom and patient images. Methods: Three levels of uncorrelated Gaussian noise were added to CT images of phantom and patients (20) acquired in static mode and respiratory tracking mode. We calculated the noise-power spectrum (NPS) of the original CT images of the phantom, and of the phantom images with added Gaussian noise with means of 50, 80, and 120 HU. Concurrently, on patient images (original and noise-added images), image features were calculated: 14 shape, 19 intensity (1st order statistics from intensity volume histograms), 18 GLCM features (2nd order statistics from grey level co-occurrence matrices) and 11 RLM features (2nd order statistics from run-length matrices). These features provide the underlying structural information of the images. GLCM (size 128x128) was calculated with a step size of 1 voxel in 13 directions and averaged. RLM feature calculation was performed in 13 directions with grey levels binning into 128 levels. Results: Adding the electronic noise to the images modified the quality of the NPS, shifting the noise from mostly correlated to mostly uncorrelated voxels. The dramatic increase in noise texture did not affect image structure/contours significantly for patient images. However, it did affect the image features and textures significantly as demonstrated by GLCM differences. Conclusion: Image features are sensitive to acquisition factors (simulated by adding uncorrelated Gaussian noise). We speculate that image features will be more difficult to detect in the presence of electronic noise (an uncorrelated noise contributor) or, for that matter, any other highly correlated image noise. This work focuses on the effect of electronic, uncorrelated, noise and future work shall examine the influence of changes in quantum noise on the features. J. Oliver was supported by NSF FGLSAMP BD award HRD #1139850 and the McKnight Doctoral Fellowship.

60 APPLIED LIFE SCIENCES↗

Non parametric denoising methods based on wavelets: Application to electron microscopy images in low exposure time

The 3D reconstruction of the Cryo-Transmission Electron Microscopy (Cryo-TEM) and Energy Filtering TEM images (EFTEM) hampered by the noisy nature of these images, so that their alignment becomes so difficult. This noise refers to the collision between the frozen hydrated biological samples and the electrons beam, where the specimen is exposed to the radiation with a high exposure time. This sensitivity to the electrons beam led specialists to obtain the specimen projection images at very low exposure time, which resulting the emergence of a new problem, an extremely low signal-to-noise ratio (SNR). This paper investigates the problem of TEM images denoising when they are acquired at very low exposure time. So, our main objective is to enhance the quality of TEM images to improve the alignment process which will in turn improve the three dimensional tomography reconstructions. We have done multiple tests on special TEM images acquired at different exposure time 0.5s, 0.2s, 0.1s and 1s (i.e. with different values of SNR)) and equipped by Golding beads for helping us in the assessment step. We herein, propose a structure to combine multiple noisy copies of the TEM images. The structure is based on four different denoising methods, to combine the multiple noisy TEM images copies. Namely, the four different methods are Soft, the Hard as Wavelet-Thresholding methods, Bilateral Filter as a non-linear technique able to maintain the edges neatly, and the Bayesian approach in the wavelet domain, in which context modeling is used to estimate the parameter for each coefficient. To ensure getting a high signal-to-noise ratio, we have guaranteed that we are using the appropriate wavelet family at the appropriate level. So we have chosen âĂIJsym8âĂİ wavelet at level 3 as the most appropriate parameter. Whereas, for the bilateral filtering many tests are done in order to determine the proper filter parameters represented by the size of the filter, the range parameter and the spatial parameter respectively. The experiments reported in this paper demonstrate the performance of the Bilateral Filtering and the Bayesian approaches in terms of improving the SNRout and the image quality. Taken together, these results suggest that the Bayesian process has a potential to outperform all the used methods, where in the multiple noisy copies structure it gave us the best SNRout without change of the golden beads diameter. The Bayesian approach yielded enhanced average image without needing a huge amount of copies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultrafast chirped optical waveform recording using referenced heterodyning and a time microscope

A new technique for capturing both the amplitude and phase of an optical waveform is presented. This technique can capture signals with many THz of bandwidths in a single shot (e.g., temporal resolution of about 44 fs), or be operated repetitively at a high rate. That is, each temporal window (or frame) is captured single shot, in real time, but the process may be run repeatedly or single-shot. This invention expands upon previous work in temporal imaging by adding heterodyning, which can be self-referenced for improved precision and stability, to convert frequency chirp (the second derivative of phase with respect to time) into a time varying intensity modulation. By also including a variety of possible demultiplexing techniques, this process is scalable to recoding continuous signals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Anatomical background and generalized detectability in tomosynthesis and cone-beam CT

Purpose: Anatomical background presents a major impediment to detectability in 2D radiography as well as 3D tomosynthesis and cone-beam CT (CBCT). This article incorporates theoretical and experimental analysis of anatomical background ''noise'' in cascaded systems analysis of 2D and 3D imaging performance to yield ''generalized'' metrics of noise-equivalent quanta (NEQ) and detectability index as a function of the orbital extent of the (circular arc) source-detector orbit. Methods: A physical phantom was designed based on principles of fractal self-similarity to exhibit power-law spectral density ({kappa}/f{sup {beta}}) comparable to various anatomical sites (e.g., breast and lung). Background power spectra [S{sub B}(f)] were computed as a function of source-detector orbital extent, including tomosynthesis ({approx}10 deg. - 180 deg.) and CBCT (180 deg. +fan to 360 deg.) under two acquisition schemes: (1) Constant angular separation between projections (variable dose) and (2) constant total number of projections (constant dose). The resulting S{sub B} was incorporated in the generalized NEQ, and detectability index was computed from 3D cascaded systems analysis for a variety of imaging tasks. Results: The phantom yielded power-law spectra within the expected spatial frequency range, quantifying the dependence of clutter magnitude ({kappa}) and correlation ({beta}) with increasing tomosynthesis angle. Incorporation of S{sub B} in the 3D NEQ provided a useful framework for analyzing the tradeoffs among anatomical, quantum, and electronic noise with dose and orbital extent. Distinct implications are posed for breast and chest tomosynthesis imaging system design--applications varying significantly in {kappa} and {beta}, and imaging task and, therefore, in optimal selection of orbital extent, number of projections, and dose. For example, low-frequency tasks (e.g., soft-tissue masses or nodules) tend to benefit from larger orbital extent and more fully 3D tomographic imaging, whereas high-frequency tasks (e.g., microcalcifications) require careful, application-specific selection of orbital extent and number of projections to minimize negative effects of quantum and electronic noise. Conclusions: The complex tradeoffs among anatomical background, quantum noise, and electronic noise in projection imaging, tomosynthesis, and CBCT can be described by generalized cascaded systems analysis, providing a useful framework for system design and optimization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Superior photo-carrier diffusion dynamics in organic-inorganic hybrid perovskites revealed by spatiotemporal conductivity imaging

Abstract The outstanding performance of organic-inorganic metal trihalide solar cells benefits from the exceptional photo-physical properties of both electrons and holes in the material. Here, we directly probe the free-carrier dynamics in Cs-doped FAPbI 3 thin films by spatiotemporal photoconductivity imaging. Using charge transport layers to selectively quench one type of carriers, we show that the two relaxation times on the order of 1 μs and 10 μs correspond to the lifetimes of electrons and holes in FACsPbI 3 , respectively. Strikingly, the diffusion mapping indicates that the difference in electron/hole lifetimes is largely compensated by their disparate mobility. Consequently, the long diffusion lengths (3~5 μm) of both carriers are comparable to each other, a feature closely related to the unique charge trapping and de-trapping processes in hybrid trihalide perovskites. Our results unveil the origin of superior diffusion dynamics in this material, crucially important for solar-cell applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Imaging Valley Excitons in a 2D Semiconductor with Scanning Tunneling Microscope-Induced Luminescence

Valley excitons dominate the optoelectronic response of transition-metal dichalcogenides and are drastically affected by structural and environmental inhomogeneities localized in these materials. Critical to understanding and controlling these nanoscale excitonic changes is the ability to correlate the imaging of excitonic states with crystalline structures on the atomic scale. Here, in this study, we apply scanning tunneling microscope-induced luminescence microscopy to image valley excitons in a semiconducting transition-metal dichalcogenide monolayer decoupled by a 10 nanometer-thick hexagonal-boron-nitride flake incorporated in a lateral homojunction on an Au electrode surface. This design enables the observation of chiral excitonic emission arising from neutral and charged valley excitons of the monolayer semiconductor at ambipolar voltages with a quantum efficiency up to similar to ~10 -5 photon/electron. The measured light helicity demonstrates considerable circular polarization dependent on the sample voltage, reaching as much as 40%. The real-space luminescence imaging maps$-$at subnanometer resolution$-$of the valley excitons reveal striking spatial variations associated with localized inhomogeneities, including surface impurities and possibly nanoscale dielectric and/or potential disorders in the monolayer. Our study introduces a promising format for 2D materials to explore and tailor their optoelectronic processes at the atomic scale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Space- and time-resolved characterization of nanosecond time scale discharge at pressurized gas

The phenomenon of ultra-fast electrical gas breakdown was investigated. Nanosecond high-voltage pulses with durations of 1 and 5 ns and amplitudes of 100 and 200 kV, respectively, were used to study the parameters of the discharge in a pressured (1-7) x 10{sup 5} Pa air-filled gap. The development of the discharge and the plasma propagation velocity was examined using optical fast frame imaging. The generation of runaway electrons in the breakdown process was confirmed by electron imaging and time-resolved x-ray diagnostics. Runaway electron beam energy distribution was obtained for a 1 ns duration high-voltage pulse. The origin and the role of runaway electrons in the discharge initiation are also discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simultaneous sample and spatial coherence characterisation using diffractive imaging

We demonstrate an algorithm that reconstructs the complex transmission function of an object from experimental X-ray diffraction data using partially coherent 1.4 keV X-rays that does not require a priori input of the coherence function. The quality of the reconstruction is significantly better than that obtained by assuming that the illumination is fully coherent. Our approach can be readily applied to diffraction imaging problems where a model for the spatial coherence can be assumed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In situ formation of pseudohalide anions induced by humid air and light passivates formamidinium‐based halide perovskites

Abstract Metal halide perovskites based on formamidinium (FA), or FA‐rich compositions have shown great promise for high‐performance photovoltaics. A deeper understanding of the impact of ambient conditions (e.g., moisture, oxygen, and illumination) on the possible reactions of FA‐based perovskite films and their processing sensitivities has become critical for further advances toward commercialization. Herein, we investigate reactions that take place on the surface of the FA 0.7 Cs 0.3 , mixed Br/I wide bandgap perovskite thin films in the presence of humid air and ambient illumination. The treatment forms a surface layer containing O, OH, and N‐based anions. We propose the latter originates from formamidine trapped at the perovskite/oxide interface reacting further to cyanide and/or formamidinate—an understudied class of pseudohalides that bind to Pb. Optimized treatment conditions improve photoluminescence quantum yield owing to both reduced surface recombination velocity and increased bulk carrier lifetime. The corresponding perovskite solar cells also exhibit improved performance. Identifying these reactions opens possibilities for better utilizing cyanide and amidinate ligands, species that may be expected during vapor processing of FA‐based perovskites. Our work also provides new insights into the self‐healing or self‐passivating of MA‐free perovskite compositions where FA and iodide damage could be partially offset by advantageous reaction byproducts. image

14 SOLAR ENERGY↗