Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantum signal processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Intermediate-temperature topological Uhlmann phase on IBM quantum computers

A spin-1 system can exhibit an intermediate-temperature topological regime with a quantized Uhlmann phase sandwiched by topologically trivial low- and high-temperature regimes. We present a quantum circuit consisting of system and ancilla qubits plus a probe qubit which prepares an initial state corresponding to the purified state of a spin-1 system at finite temperature, evolves the system according to the Uhlmann process, and measures the Uhlmann phase via expectation values of the probe qubit. Although classical simulations suggest the quantized Uhlmann phase is observable on International Business Machines (IBM’s) noisy intermediate-scale quantum (NISQ) computers, an implementation of the circuit without any optimization exceeds the gate count for the error budget and results in unresolved signals. Through a series of optimization with Qiskit and BQSKit, the gate count can be substantially reduced, making the jumps of the Uhlmann phase more visible. A recent hardware upgrade of IBM quantum computers further improves the signals and leads to a clearer demonstration of interesting finite-temperature topological phenomena on NISQ hardware.

Mastandrea, Christopher [Univ. of California, Merc↗

A fast reconstruction method of the dense point-cloud model for cultural heritage artifacts based on compressed sensing and sparse auto-encoder

Since the point cloud data of cultural heritage artifacts obtained by the laser scanner is enormous and dense, these lead to a large quantity of network resource for storing, processing, and transmission. This paper provided a fast reconstruction method of the dense point cloud model for cultural relics based on sparse auto-encoder and compressed sensing. Firstly, the octree method based on the hash function was utilized to extract local features and remove redundant points. Secondly, the point cloud, which can be seen as the 3D geometric signal, is projected to the discrete Laplacian sparse basis via the point cloud adjacency matrix. Then, aiming at the bottleneck of slow recovery caused by tremendous scale of inverse problem based on compressed sensing theory, the sparse auto-encoder was applied to reduce the dimension and speed up the recovery. Finally, the OMP algorithm was applied to reconstruct 3D point cloud model based on the stochastic Gauss matrix. In order to test the performance of our methods, the 3D point cloud model of terracotta warriors and horses head were used. And the experimental results demonstrated that our approach can obviously accelerate the process of reconstruction of the dense point cloud model for the cultural heritage artifacts and ensure the recovery accuracy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-sensitive scanning laser magneto-optical imaging system

A high-sensitive scanning laser magneto-optical (MO) imaging system has been developed. The system is mainly composed of a laser source, galvano meters, and a high-sensitive differential optical-detector. Preliminary evaluation of system performance by using a Faraday indicator with a Faraday rotation coefficient of 3.47x10{sup -5} rad/{mu}m Oe shows a magnetic sensitivity of about 5 {mu}T, without any need for accumulation or averaging processing. Using the developed MO system we have succeeded in the fast and quantitative imaging of a rotationally symmetric magnetic field distribution around an YBa{sub 2}Cu{sub 3}O{sub 7-{delta}} (YBCO) strip line applied with dc-biased current, and also succeeded in the detection of quantized fine signals corresponding to magnetic flux quantum generation in a superconducting loop of an YBCO Josephson vortex flow transistor. Thus, the developed system enables us not only to do fast imaging and local signal detection but also to directly evaluate both the strength and direction of a magnetic signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Robotic reconnaissance platform. I. Spectroscopic instruments with rangefinders

In this paper, basic principles of the design and implementation of a portable, multi-functional scientific instrument, operating from a robotic reconnaissance mobile platform are discussed. The current version of the instrument includes a multi-gas laser sensor, multi-functional spectrometer, isotopes identifier, cameras, and rangefinder. An additional set of sensors monitors temperature, pressure, humidity, and background radiation. All components are installed on a mini-robotic platform, which provides data acquisition, processing, and transmittance. The design focuses on the development of calibration-free, reliable, low power-consumption devices. To create a highly survivable, accurate, and reliable instrument, a concept of an inhomogeneous sensory network has been developed. Such a network combines non-identical sensors and provides cross-use of information received from different sensors to describe environmental conditions, to choose appropriate algorithms of data processing, and to achieve high accuracy gas-concentration measurements. The system uses the same lasers to operate different optical devices such as sensors, rangefinders, spectrometers, and isotopes identifiers. Among the innovative elements described in this paper, are a calibration-free, laser multi-gas sensor with range-finding option; a high signal/noise ratio transmittance spectrometer; a single-frequency laser with nano-selector; and low repetition-rate femtosecond fiber lasers operating in near- and middle- infrared spectral ranges. New detailed analyses of absorption spectroscopy theoretical approximations made it possible to achieve high-accuracy gas-concentration measurements with miniature optical sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Doppler mapping of an alternating-sign flow with complex geometry using optical coherence tomography

The method of sign-sensitive mapping of the given range of velocities in a flow with complex geometry based on the principles of optical coherence tomography is described. To produce an alternating-sign flow, the 1% aqueous intralipid solution and the tilted capillary entry with the contraction coefficient 4:1 are used. The mapping is controlled using two parameters, the value of one specific velocity (OSV) for mapping and the accuracy of its determination. The structure image and two OSV images (for positive and negative direction of motion) are obtained as a result of selecting and processing the relevant parts of the signal spectrum. The final image is a result of summing these three images and can be used as a Doppler equivelocity contour map. (radiation scattering)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical properties of costal cartilage and their variation in the process of non-destructive action of laser radiation with the wavelength 1.56 μm

The optical properties of costal cartilage and their variation under the action of laser radiation with the wavelength 1.56 μm are studied. The laser action regime corresponds to that used for changing the cartilage shape. The dynamics of the passed scattered laser radiation was studied by means of the optical fibre system, and the optical properties of the cartilage tissue (on the basis of Monte Carlo modelling of light propagation) – using the setup with two integrating spheres. Under the influence of radiation, the characteristics of which corresponded to those used for the cartilage shape correction, no essential changes in the optical parameters were found. The results obtained in the course of studying the dynamics of optical signals in the process of costal cartilage irradiation can be used for developing control systems, providing the safety and efficiency of laser medical technologies. (biophotonics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Search for C -even states decaying to D s ± D s * ∓ with masses between 4.08 and 4.32 GeV / c 2

Six C -even states, denoted as X , with quantum numbers J P C = 0 − + , 1 ± + , or 2 ± + , are searched for via the e + e − → γ D s ± D s * ∓ process using ( 1667.39 ± 8.84 ) pb − 1 of e + e − collision data collected with the BESIII detector operating at the BEPCII storage ring at center-of-mass energy of s = ( 4681.92 ± 0.30 ) MeV . No statistically significant signal is observed in the mass range from 4.08 GeV / c 2 to 4.32 GeV / c 2 . The upper limits of σ [ e + e − → γ X ] · B [ X → D s ± D s * ∓ ] at a 90% confidence level are determined. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Miniaturized Airborne Imaging Central Server System

In recent years, some remote-sensing applications require advanced airborne multi-sensor systems to provide high performance reflective and emissive spectral imaging measurement rapidly over large areas. The key or unique problem of characteristics is associated with a black box back-end system that operates a suite of cutting-edge imaging sensors to collect simultaneously the high throughput reflective and emissive spectral imaging data with precision georeference. This back-end system needs to be portable, easy-to-use, and reliable with advanced onboard processing. The innovation of the black box backend is a miniaturized airborne imaging central server system (MAICSS). MAICSS integrates a complex embedded system of systems with dedicated power and signal electronic circuits inside to serve a suite of configurable cutting-edge electro- optical (EO), long-wave infrared (LWIR), and medium-wave infrared (MWIR) cameras, a hyperspectral imaging scanner, and a GPS and inertial measurement unit (IMU) for atmospheric and surface remote sensing. Its compatible sensor packages include NASA s 1,024 1,024 pixel LWIR quantum well infrared photodetector (QWIP) imager; a 60.5 megapixel BuckEye EO camera; and a fast (e.g. 200+ scanlines/s) and wide swath-width (e.g., 1,920+ pixels) CCD/InGaAs imager-based visible/near infrared reflectance (VNIR) and shortwave infrared (SWIR) imaging spectrometer. MAICSS records continuous precision georeferenced and time-tagged multisensor throughputs to mass storage devices at a high aggregate rate, typically 60 MB/s for its LWIR/EO payload. MAICSS is a complete stand-alone imaging server instrument with an easy-to-use software package for either autonomous data collection or interactive airborne operation. Advanced multisensor data acquisition and onboard processing software features have been implemented for MAICSS. With the onboard processing for real time image development, correction, histogram-equalization, compression, georeference, and data organization, fast aerial imaging applications, including the real time LWIR image mosaic for Google Earth, have been realized for NASA fs LWIR QWIP instrument. MAICSS is a significant improvement and miniaturization of current multisensor technologies. Structurally, it has a complete modular and solid-state design. Without rotating hard drives and other moving parts, it is operational at high altitudes and survivable in high-vibration environments. It is assembled from a suite of miniaturized, precision-machined, standardized, and stackable interchangeable embedded instrument modules. These stackable modules can be bolted together with the interconnection wires inside for the maximal simplicity and portability. Multiple modules are electronically interconnected as stacked. Alternatively, these dedicated modules can be flexibly distributed to fit the space constraints of a flying vehicle. As a flexibly configurable system, MAICSS can be tailored to interface a variety of multisensor packages. For example, with a 1,024x1,024 pixel LWIR and a 8,984x6,732 pixel EO payload, the complete MAICSS volume is approximately 7x9x11 in. (=18x23x28 cm), with a weight of 25 lb (=11.4 kg).

Sun, Xiuhong↗

Practical witness for electronic coherences

The origin of the coherences in two-dimensional spectroscopy of photosynthetic complexes remains disputed. Recently, it has been shown that in the ultrashort-pulse limit, oscillations in a frequency-integrated pump-probe signal correspond exclusively to electronic coherences, and thus such experiments can be used to form a test for electronic vs. vibrational oscillations in such systems. Here, we demonstrate a method for practically implementing such a test, whereby pump-probe signals are taken at several different pulse durations and used to extrapolate to the ultrashort-pulse limit. We present analytic and numerical results determining requirements for pulse durations and the optimal choice of pulse central frequency, which can be determined from an absorption spectrum. Our results suggest that for numerous systems, the required experiment could be implemented by many ultrafast spectroscopy laboratories using pulses of tens of femtoseconds in duration. Such experiments could resolve the standing debate over the nature of coherences in photosynthetic complexes.

47 OTHER INSTRUMENTATION↗

Radiation Hard CMOS Sensors for Detector at High Energy Colliders

In this project we developed a radiation hard CMOS sensor architecture for High Energy Colliders. The key accomplishments were: 1. Developed a sensor architecture to support very high occupancy rate and hit rates 2. Developed, simulated (TCAD), and fabricated 20 different types of pixelated test structures for the quadruple well high resistivity substrate process. Measured performance of these pixel test structures; Dark currents were found to be close to physical limits; and Quantum efficiency were found to be close to ideal as well 3. Defined the scope for the PDK for the quadruple well process on high resistivity silicon Highlights of the new architecture are: Readout of pixel arrays with reconstruction efficiency >99% at hit rates of 500 MHits/cm 2 and array occupancy of 0.2%; Minimization of in-pixel signal storage requirement (data will be read out at frame rates of 1MHz); Low power dissipation through integration of fragmented projection architecture (Minimum analog power dissipation); Pixel array level data reduction (Hit location is encoded through shape of sub-block projections); Programmable resolution and frame rate (Pixels can be binned to increase frame rate); Minimum data overhead, encoded projection results for all sub-blocks are read out without location information

43 PARTICLE ACCELERATORS↗

Scheme for measuring experimentally the velocity of pilot waves and the discreteness of time

We consider the following two questions. Suppose that a quantum system suffers a change of the boundary condition or the potential at a given space location. Then (1)when will the wavefunction shows a response to this change at another location? And (2)how does the wavefunction changes?The answer to question (1) could reveal how a quantum system gets information on the boundary condition or the potential. Here we show that if the response takes place immediately, then it can allow superluminal signal transfer. Else if the response propagates in space with a finite velocity, then it could give a simple explanation why our world shows classicality on the macroscopic scale. Furthermore, determining the exact value of this velocity can either clarify the doubts on static experiments for testing Bell's inequality, or support the pilot-wave interpretation of quantum mechanics. We propose a feasible experimental scheme for measuring this velocity, which can be implemented with state-of-art technology, e.g., single-electron biprism interferometry.Question (2) is studied with a square-well potential model, and we find a paradox between the impossibility of superluminal signal transfer and the normalization condition of wavefunctions. To solve the paradox, we predict that when a change of the potential occurs at a given space location, the system will show no response to this change at all, until after a certain time interval. Otherwise either special relativity or quantum mechanics will be violated. As a consequence, no physical process can actually happen within Planck time. Therefore it gives a simple proof that time is discrete, with Planck time being the smallest unit. Combining with the answer to question (1), systems with a larger size and a slower velocity could have a larger unit of time, making it possible to test the discreteness of time experimentally. Our result also sets a limit on the speed of computers, and gives instruction to the search of quantum gravity theories.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multi-channel lock-in amplifier assisted femtosecond time-resolved fluorescence non-collinear optical parametric amplification spectroscopy with efficient rejection of superfluorescence background

Superfluorescence appears as an intense background in femtosecond time-resolved fluorescence noncollinear optical parametric amplification spectroscopy, which severely interferes the reliable acquisition of the time-resolved fluorescence spectra especially for an optically dilute sample. Superfluorescence originates from the optical amplification of the vacuum quantum noise, which would be inevitably concomitant with the amplified fluorescence photons during the optical parametric amplification process. Here, we report the development of a femtosecond time-resolved fluorescence non-collinear optical parametric amplification spectrometer assisted with a 32-channel lock-in amplifier for efficient rejection of the superfluorescence background. With this spectrometer, the superfluorescence background signal can be significantly reduced to 1/300–1/100 when the seeding fluorescence is modulated. An integrated 32-bundle optical fiber is used as a linear array light receiver connected to 32 photodiodes in one-to-one mode, and the photodiodes are further coupled to a home-built 32-channel synchronous digital lock-in amplifier. As an implementation, time-resolved fluorescence spectra for rhodamine 6G dye in ethanol solution at an optically dilute concentration of 10{sup −5}M excited at 510 nm with an excitation intensity of 70 nJ/pulse have been successfully recorded, and the detection limit at a pump intensity of 60 μJ/pulse was determined as about 13 photons/pulse. Concentration dependent redshift starting at 30 ps after the excitation in time-resolved fluorescence spectra of this dye has also been observed, which can be attributed to the formation of the excimer at a higher concentration, while the blueshift in the earlier time within 10 ps is attributed to the solvation process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Delta-Doped Back-Illuminated CMOS Imaging Arrays: Progress and Prospects

In this paper, we report the latest results on our development of delta-doped, thinned, back-illuminated CMOS imaging arrays. As with charge-coupled devices, thinning and back-illumination are essential to the development of high performance CMOS imaging arrays. Problems with back surface passivation have emerged as critical to the prospects for incorporating CMOS imaging arrays into high performance scientific instruments, just as they did for CCDs over twenty years ago. In the early 1990's, JPL developed delta-doped CCDs, in which low temperature molecular beam epitaxy was used to form an ideal passivation layer on the silicon back surface. Comprising only a few nanometers of highly-doped epitaxial silicon, delta-doping achieves the stability and uniformity that are essential for high performance imaging and spectroscopy. Delta-doped CCDs were shown to have high, stable, and uniform quantum efficiency across the entire spectral range from the extreme ultraviolet through the near infrared. JPL has recently bump-bonded thinned, delta-doped CMOS imaging arrays to a CMOS readout, and demonstrated imaging. Delta-doped CMOS devices exhibit the high quantum efficiency that has become the standard for scientific-grade CCDs. Together with new circuit designs for low-noise readout currently under development, delta-doping expands the potential scientific applications of CMOS imaging arrays, and brings within reach important new capabilities, such as fast, high-sensitivity imaging with parallel readout and real-time signal processing. It remains to demonstrate manufacturability of delta-doped CMOS imaging arrays. To that end, JPL has acquired a new silicon MBE and ancillary equipment for delta-doping wafers up to 200mm in diameter, and is now developing processes for high-throughput, high yield delta-doping of fully-processed wafers with CCD and CMOS imaging devices.

imagers↗

The throughput calibration of the VERITAS telescopes

Context. The response of imaging atmospheric Cherenkov telescopes to incident γ -ray-initiated showers in the atmosphere changes as the telescopes age due to exposure to light and weather. These aging processes affect the reconstructed energies of the events and γ -ray fluxes. Aims. This work discusses the implementation of signal calibration methods for the Very Energetic Radiation Imaging Telescope Array System (VERITAS) to account for changes in the optical throughput and detector performance over time. Methods. The total throughput of a Cherenkov telescope is the product of camera-dependent factors, such as the photomultiplier tube gains and their quantum efficiencies, and the mirror reflectivity and Winston cone response to incoming radiation. This document summarizes different methods to determine how the camera gains and mirror reflectivity have evolved over time and how we can calibrate this changing throughput in reconstruction pipelines for imaging atmospheric Cherenkov telescopes. The implementation is validated against seven years of observations with the VERITAS telescopes of the Crab Nebula, which is a reference object in very-high-energy astronomy. Results. Regular optical throughput monitoring and the corresponding signal calibrations are found to be critical for the reconstruction of extensive air shower images. The proposed implementation is applied as a correction to the signals of the photomultiplier tubes in the telescope simulation to produce fine-tuned instrument response functions. This method is shown to be effective for calibrating the acquired γ -ray data and for recovering the correct energy of the events and photon fluxes. At the same time, it keeps the computational effort of generating Monte Carlo simulations for instrument response functions affordably low.

79 ASTRONOMY AND ASTROPHYSICS↗

Simulation of the interaction of electromagnetic waves with dispersed particles in the propagation of breather in the surface layer of a liquid medium

A numerical simulation of the interaction of laser radiation with dispersed particles in the course of propagation of breather in the surface layer of the liquid breather was performed. The shape and amplitude of the acoustic signal formed in this interaction were obtained. Two acoustic signals, before and after the impact of a breather on the process of optical sound generation, were compared. Results of the comparison showed that the breather spreading over the surface of the liquid medium affecst the acoustic signal and its effect must be considered in the measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The spectrum of darkonium in the Sun

Dark matter that gets captured in the Sun may form positronium-like bound states if it self-interacts via light dark photons. In this case, dark matter can either annihilate to dark photons or recombine in bound states which subsequently also decay to dark photons. The fraction of the dark photons that leave the Sun without decaying to Standard Model particles have a characteristic energy spectrum which is a mixture of the direct annihilation process, the decays of ortho- and para- bound states and the recombination process. The ultimate decay of these dark photons to positron-electron pairs (via kinetic mixing) outside the Sun creates a distinct signal that can either identify or set strict constraints on dark photon models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonreciprocal signal routing in an active quantum network

As superconductor quantum technologies are moving towards large-scale integrated circuits, a robust and flexible approach to routing photons at the quantum level becomes a critical problem. Active circuits, which contain parametrically driven elements selectively embedded in the circuit, offer a viable solution. In this work, we present a general strategy for routing nonreciprocally quantum signals between two sites of a given lattice of oscillators, implementable with existing superconducting circuit components. Our approach makes use of a dual lattice of overdamped oscillators linking the nodes of the main lattice. Solutions for spatially selective driving of the lattice elements can be found, which optimally balance coherent and dissipative hopping of microwave photons to nonreciprocally route signals between two given nodes. In certain lattices these optimal solutions are obtained at the exceptional point of the dynamical matrix of the network. We also demonstrate that signal and noise transmission characteristics can be separately optimized.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Search for New Physics in Neutral Kaon Decays

This report will summarize contributions made by the ASU group during the grant period. Focus will be given to three areas: (1) Monte Carlo simulations; (2) signal processing in the electronics; and (3) data analysis software. For reference, a drawing of the KOTO detector is shown in Fig. 1. The production target for the neutral beam particles was about 20 meters upstream of the detector.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗