Search NASA⌕ Search

SEARCH · Search NASA

Results for “radiance calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

PACE OCI Lunar Calibration: Initial Results

Launched in February 2024, the Ocean Color Instrument (OCI) onboard NASA’s Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission has started performing its monthly lunar calibrations at ±7degreeslunar phase angle in March 2024. In this paper, we will describe the OCI lunar calibration methodology and show the results of lunar calibration events during the initial months of PACE/OCI operation. A key difference of OCI lunar calibration from heritage sensors is that the lunar disk integrated irradiance is computed from lunar pixel radiance and sampling distance instead of the instrument’s IFOV. PACE provided a near constant sweep rate during lunar calibration allowing accurate determination of OCI pixel sampling extent. OCI performs lunar calibration in baseline science mode with 282 hyperspectral bands from 315 –895 nm and 7 shortwave infrared bands(940 -2260 nm). For each OCI band, we compute the integrated lunar disk irradiance, and compare the result with a lunar irradiance model (ROLO)prediction. The early results presented here clearly show that OCI’s lunar image acquisition is working as intended and will provide accurate data for OCI’s on-orbit radiometric characterization. The hyperspectral lunar irradiances provided by OCI are expected to become a valuable data set for the evaluation of lunar irradiance models.

calibration↗

A Consistent EPIC Visible Channel Calibration using VIIRS and MODIS as a Reference

The Earth Polychromatic Imaging Camera (EPIC) aboard the Deep Space Climate Observatory (DSCOVR) satellite constantly images the sunlit disk of Earth from the Lagrange-1 (L1) point in 10 spectral channels spanning the UV, VIS, and NIR spectrums. Recently, the DSCOVR EPIC team has publicly released version 2 dataset, which has implemented improved navigation, stray-light correction, and flat-fielding of the CCD array. The EPIC 2-year data record must be well-calibrated for consistent cloud, aerosol, trace gas, land use and other retrievals. Because EPIC lacks onboard calibrators, the observations made by EPIC channels must be calibrated vicariously using the coincident measurements from radiometrically stable instruments that have onboard calibration systems. MODIS and VIIRS are best-suited instruments for this task as they contain similar spectral bands that are well-calibrated onboard using solar diffusers and lunar tracking. We have previously calibrated the EPIC version 1 dataset by using EPIC and VIIRS angularly matched radiance pairs over both all-sky ocean and deep convective clouds (DCC). We noted that the EPIC image required navigations adjustments, and that the EPIC stray-light correction provided an offset term closer to zero based on the linear regression of the EPIC and VIIRS ray-matched radiance pairs. We will evaluate the EPIC version 2 navigation and stray-light improvements using the same techniques. In addition, we will monitor the EPIC channel calibration over the two years for any temporal degradation or anomalous behavior. These two calibration methods will be further validated using desert and DCC invariant Earth targets. The radiometric characterization of the selected invariant targets is performed using multiple years of MODIS and VIIRS measurements. Results of these studies will be shown at the conference.

Haney, C. O.↗

In-Situ Transfer Standard and Coincident-View Intercomparisons for Sensor Cross-Calibration

There exist numerous methods for accomplishing on-orbit calibration. Methods include the reflectance-based approach relying on measurements of surface and atmospheric properties at the time of a sensor overpass as well as invariant scene approaches relying on knowledge of the temporal characteristics of the site. The current work examines typical cross-calibration methods and discusses the expected uncertainties of the methods. Data from the Advanced Land Imager (ALI), Advanced Spaceborne Thermal Emission and Reflection and Radiometer (ASTER), Enhanced Thematic Mapper Plus (ETM+), Moderate Resolution Imaging Spectroradiometer (MODIS), and Thematic Mapper (TM) are used to demonstrate the limits of relative sensor-to-sensor calibration as applied to current sensors while Landsat-5 TM and Landsat-7 ETM+ are used to evaluate the limits of in situ site characterizations for SI-traceable cross calibration. The current work examines the difficulties in trending of results from cross-calibration approaches taking into account sampling issues, site-to-site variability, and accuracy of the method. Special attention is given to the differences caused in the cross-comparison of sensors in radiance space as opposed to reflectance space. The results show that cross calibrations with absolute uncertainties lesser than 1.5 percent (1 sigma) are currently achievable even for sensors without coincident views.

Advanced Spaceborne Thermal Emission and Reflectio↗

Calibration to surface reflectance of terrestrial imaging spectrometry data: Comparison of methods

Many algorithms for spectral analysis of imaging spectroscopy data of the Earth's surface require that the data be calibrated to surface reflectance. Calibration requires removing instrumental response, solar irradiance, atmospheric transmittance, and atmospheric scattering from the radiance detected at the sensor. Depending on the amount of support data, this can be a formidable task. This paper examines four methods of calibration: (1) a radiative transfer model from the University of Colorado (ATREM: Gao and Goetz, 1990; Gao et al., 1992), (2) a MODTRAN-based method developed at the Jet Propulsion Lab by Green et al., (1191), (3) a ground calibration using known sites as standards, and (4) a combined approach using radiative transfer methods and ground calibration. Data from the Airborne Visual and Infra-Red Imaging Spectrometer (AVIRIS) instrument were evaluated from data sets obtained over multiple years and multiple sites.

Clark, Roger N.↗

Coastal zone color scanner 'system calibration': A retrospective examination

During its lifetime the Coastal Zone Color Scanner (CZCS) produced approximately 66,000 images. These have been placed in an archive of 'raw' radiance (sensor counts) in a subsampled format that is easily accessible. They have also been processed to form global fields, at reduced resolution, of normalized water-leaving radiance, phytoplankton pigments, and diffuse attenuation coefficient. Using this archive, we have tried to characterize some aspects of the 'system calibration' for the 8-year lifetime of CZCS. Specifically, we have assumed that the sensitivity of the red band decayed in a simple manner similar to the well-known long-term degradation of the shorter-wavelength bands, and we examined the sensitivity of the green and yellow bands by computing the globally averaged water-leaving radiance, over 10-day periods, for all of the imagery. The results provided evidence that in addition to the long-term degradation, short-term (2 weeks to 1 month) variations in the radiometric sensitivity of these bands started in early fall 1981 and continued for the rest of the mission. In contrast, the data suggested the absence of such variations prior to August 1981. It is reasonable to believe that the sensitivity of the blue (and probably the red) band underwent such variations as well; however our methodology cannot be used to study the other bands. Thus, after these fluctuations began, the actual values of CZCS - estimated pigment concentrations at a given location should be viewed with skepticism; however, the global patterns of derived pigment concentrations should be valid. Had an extensive set of surface measurements of water-leaving radiance, e.r., from moored buoyes or drifters, had been available during the CZCS mission, these fluctuations could have been removed from the data set, and this would have greatly increased its value. The lessons learned from CZCS that is, the requirement of good radiometric calibration and stability and the necessity of 'sea truth' stations to monitor the performance of the system (sensor plus algorithms), are being applied to the sea-viewing wide-field-of-view senso (Sea WiFS) scheduled for launch in August 1993.

Evans, Robert H.↗

Improvement in the Characterization of MODIS Subframe Difference

MODIS is a key instrument of NASA's Earth Observing System. It has successfully operated for 16+ years on the Terra satellite and 14+ years on the Aqua satellite, respectively. MODIS has 36 spectral bands at three different nadir spatial resolutions, 250m (bands 1-2), 500m (bands 3-7), and 1km (bands 8-36). MODIS subframe measurement is designed for bands 1-7 to match their spatial resolution in the scan direction to that of the track direction. Within each 1 km frame, the MODIS 250 m resolution bands sample four subframes and the 500 m resolution bands sample two subframes. The detector gains are calibrated at a subframe level. Due to calibration differences between subframes, noticeable subframe striping is observed in the Level 1B (L1B) products, which exhibit a predominant radiance-level dependence. This paper presents results of subframe differences from various onboard and earth-view data sources (e.g. solar diffuser, electronic calibration, spectro-radiometric calibration assembly, Earth view, etc.). A subframe bias correction algorithm is proposed to minimize the subframe striping in MODIS L1B image. The algorithm has been tested using sample L1B images and the vertical striping at lower radiance value is mitigated after applying the corrections. The subframe bias correction approach will be considered for implementation in future versions of the calibration algorithm.

Li, Yonghong↗

Inventory of forest and rangeland and detection of forest stress

The author has identified the following significant results. Three small scales of CIR photography were interpreted to determine the number of bark beetle-killed trees detected in each of six spot size categories. A procedure was developed to predict the probability of detecting spots in each spot size category and in turn to estimate the number of infestations and dead trees even on the smallest scale. Statistical tests of the data indicated that the linear model did not fit the data and that other models should be tested. As a result of daily monitoring of Black Hills radiometric instruments it was possible to show the spectral energy relationships in the ponderosa pine ecosystems over time. These data have been helpful for comparison with radiance signatures extracted from ERTS-1 bulk 70mm using precision microdensitometry. Effects of atmospheric interference were shown by a 30 percent increase in scene radiance on channel 4 of the satellite imagery. A calibration and scaling technique was developed and tested to enable interpretation of ERTS-1 bulk and precision data for the Atlanta test site. The technique includes calibration of a photographic copy system for the I2S image combiner and the production of scaled overlays of grid coordinate systems, study area locations, and outline maps of county boundaries.

Heller, R. C.↗

Laboratory requirements for in-situ and remote sensing of suspended material

Recommendations for laboratory and in-situ measurements required for remote sensing of suspended material are presented. This study investigates the properties of the suspended materials, factors influencing the upwelling radiance, and the various types of remote sensing techniques. Calibration and correlation procedures are given to obtain the accuracy necessary to quantify the suspended materials by remote sensing. In addition, the report presents a survey of the national need for sediment data, the agencies that deal with and require the data of suspended sediment, and a summary of some recent findings of sediment measurements.

Kuo, C. Y.↗

Laboratory requirements for in-situ and remote sensing of suspended material

Recommendations for laboratory and in-situ measurements required for remote sensing of suspended material are presented. This study investigates the properties of the suspended materials, factors influencing the upwelling radiance, and the various types of remote sensing techniques. Calibration and correlation procedures are given to obtain the accuracy necessary to quantify the suspended materials by remote sensing. In addition, the report presents a survey of the national need for sediment data, the agencies that deal with and require the data of suspended sediment, and a summary of some recent findings of sediment measurements.

Kuo, C. Y.↗

Field measurement of spectral reflectance

It is pointed out that success in acquiring remote sensing data for describing a given target, such as vegetation, is contingent upon an understanding of the reflectance properties of the target and its surroundings. Field measurements of a target's spectral reflectance are in most cases made with single-beam instruments by sequentially viewing the target and a white standard reflector, which is assumed to be Lambertian. Since variation in atmospheric transmission can occur between the times of measuring the target and the standard reflector, substantial errors in reflectance calculated from these measurements may result. To preclude this possibility the irradiance on, and the radiance reflected from, the target must be measured simultaneously. Measurements of the spectral hemispherical-conical reflectance of a target are made by simultaneously measuring irradiance and radiance with pairs of portable spectroradiometers. The techniques for calibrating the instruments and for collecting and analyzing spectral reflectance data on vegetative canopies are described. Significant instrumental sources of error and their magnitude are discussed, together with problems involved in making such measurements.

Duggin, M. J.↗

User's guide for the Solar Backscattered Ultraviolet (SBUV) and the Total Ozone Mapping Spectrometer (TOMS) RUT-S and RUT-T data sets: October 31, 1978 to November 1, 1980

Raw data from the Solar Backscattered Ultrviolet/Total Ozone Mapping Spectrometer (SBUV/TOMS) Nimbus 7 operation are available on computer tape. These data are contained on two separate sets of RUTs (Raw Units Tapes) for SBUV and TOMS, labelled RUT-S and RUT-T respectively. The RUT-S and RUT-T tapes contain uncalibrated radiance and irradiance data, housekeeping data, wavelength and electronic calibration data, instrument field-of-view location and solar ephemeris information. These tapes also contain colocated cloud, terrain pressure and snow/ice thickness data, each derived from an independent source. The "RUT User's Guide" describes the SBUV and TOMS experiments, the instrument calibration and performance, operating schedules, and data coverage, and provides an assessment of RUT-S and -T data quality. It also provides detailed information on the data available on the computer tapes.

Fleig, A. J.↗

Estimation of tropical forest canopy temperatures, thermal response numbers, and evapotranspiration using an aircraft-based thermal sensor

Thermal infrared Multispectral Scanner (TIMS) data were collected at a resolution of 5 to 10 m from a tropical rain forest over an elevation gradient from 35 to 2700 m in the Braulio Carrillo National Park in Costa Rica. Flight lines were repeated with a 15 to 30 minute time difference for measurement of forest canopy thermal response over time. Concurrent radiosonde measurements of atmospheric profiles of air temperature and moisture provided inputs to LOWTRAN6 for atmospheric radiance corrections of the TIMS data. Techniques for using calibrated aircraft-based thermal scanner data to examine tropical forest canopy thermal properties are described. Forest canopy temperature changes over time assessed between repeated, duplicated flight lines were combined with estimates of surface radiative energy measurements from towers above the forest canopy to determine temperature spatial variability, calculate Thermal Response Numbers (TRN), and estimate evapotranspiration along the elevation gradient from selected one hectare forest inventory plots.

Luvall, Jeffrey C.↗

Calibrated intercepts for solar radiometers used in remote sensor calibration

Calibrated solar radiometer intercepts allow spectral optical depths to be determined for days with intermittently clear skies. This is of particular importance on satellite sensor calibration days that are cloudy except at the time of image acquisition. This paper describes the calibration of four solar radiometers using the Langley-Bouguer technique for data collected on days with a clear, stable atmosphere. Intercepts are determined with an uncertainty of less than six percent, corresponding to a maximum uncertainty of 0.06 in optical depth. The spread of voltage intercepts calculated in this process is carried through three methods of radiometric calibration of satellite sensors to yield an uncertainty in radiance at the top of the atmosphere of less than one percent associated with the uncertainty in solar radiometer intercepts for a range of ground reflectances.

Gellman, David I.↗

Radiometric calibration and atmospheric correction of satellite and aircraft data for FIFE

The satellite and aircraft radiometric calibration and atmospheric correction work carried out as part of the first International Satellite Land Surface Climatology Project (ISLSCP) Field Experiment (FIFE) are summarized. A large volume (120 Gbytes) of radiometric data were acquired and derived from a number of different instruments on a variety of platforms. The same basic procedure was applied to each instrument: derive the most recent calibration coefficients for converting sensor counts to reflective spectral radiances; correct the radiances for earth-sun distance variations and incident solar spectral irradiance within the bandpass of each respective instrument channel at the top of the atmosphere; characterize the atmosphere for aerosols and absorbing gases; and derive apparent surface reflectance by correcting the exoatmospheric values for atmospheric attenuation. The same basic approach was used for surface temperature derivation. The results of this processing were verified by surface measurements, and corroborated by sensor intercomparisons.

Goetz, Scott J.↗

Achieving Climate Change Absolute Accuracy in Orbit

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission will provide a calibration laboratory in orbit for the purpose of accurately measuring and attributing climate change. CLARREO measurements establish new climate change benchmarks with high absolute radiometric accuracy and high statistical confidence across a wide range of essential climate variables. CLARREO's inherently high absolute accuracy will be verified and traceable on orbit to Système Internationale (SI) units. The benchmarks established by CLARREO will be critical for assessing changes in the Earth system and climate model predictive capabilities for decades into the future as society works to meet the challenge of optimizing strategies for mitigating and adapting to climate change. The CLARREO benchmarks are derived from measurements of the Earth's thermal infrared spectrum (5-50 micron), the spectrum of solar radiation reflected by the Earth and its atmosphere (320-2300 nm), and radio occultation refractivity from which accurate temperature profiles are derived. The mission has the ability to provide new spectral fingerprints of climate change, as well as to provide the first orbiting radiometer with accuracy sufficient to serve as the reference transfer standard for other space sensors, in essence serving as a "NIST [National Institute of Standards and Technology] in orbit." CLARREO will greatly improve the accuracy and relevance of a wide range of space-borne instruments for decadal climate change. Finally, CLARREO has developed new metrics and methods for determining the accuracy requirements of climate observations for a wide range of climate variables and uncertainty sources. These methods should be useful for improving our understanding of observing requirements for most climate change observations.

Wielicki, Bruce A.↗

Understanding the Uncertainty and Variability of Earth’s Radiation Budget Components Over the Past 3 Decades from the NASA’s GEWEX Surface Radiation Budget Release 4 Integrated Product

The NASA/GEWEX Surface Radiation Budget (SRB) project produced a 30+ year time series of 3-hourly Top-of-Atmosphere (TOA) and surface radiative flux components at a 1x1 degree resolution. This SRB Release 4 Integrated Productare derived using imager data products from the cross-calibrated from ISCCP (International Satellite Cloud Climatology Project) “HSeries” radiance, cloud and surface property data products. The ISCCP HXS product replaces ISCCP DX with a ninefold increase in pixel count (10km instead of 30km). ISCCP also provides an atmospheric temperature and moisture dataset known as nnHIRS which we use and discuss radiative flux sensitivities to in this presentation. Total solar irradiance is now variable consistent with SORCE measurements. Sea surface (SeaFlux v2.0) and land surface products (LandFlux) are utilized to achieve an radiative flux estimatesintegrated with global data sets from these GEWEX projects. The variable aerosol composition are specified using a detailed aerosol history from the Max Planck Institute Aerosol Climatology (MAC) also used for background aerosol in the ISCCP HX. Numerous other improvements were made to the SW and LW algorithms including improved cloud optical property treatments and specification of surface spectral albedo and emissivity for various surface conditions. Here we analyze the new SWand LWSRB datasets, comparing them to the previous Release 3, BSRN, GEBA and PMEL surface measurements, and ERBE and CERES satellite datasets. For surface flux validation besides ensemble comparisons, we show the variability of SRB vs surface measurements from BSRN beginning in 1992 and GEBA SW from 1983. We assess the variability of the surface flux anomalies, particularly the net fluxes and the cloud radiative effects, over the entire time period including the period containing CERES overlap. For the TOA fluxes, the anomalies of the fluxes in the early period are compared to the MEaSURES ERBE and the latter period to CERES EBAF/SYN1Deg datasets for a benchmark. Long-term changes in the surface radiation budget components and cloud radiative effects are shown and discussed relative to CERES and surface measurements. This includes a change point analysis that helps associate various changes in the ISCCP GEO/LEO configurations and other inputs to variations in the radiative budget components.

Earth Radiation Budget↗

A Consistent AVHRR Visible Calibration Record Based on Multiple Methods Applicable for the NOAA Degrading Orbits: Validation - Part 2

Consistent cross-sensor Advanced Very High Resolution Radiometer (AVHRR) calibration coefficients are determined using desert, polar ice, and deep convective cloud (DCC) invariant Earth targets. The greatest AVHRR calibration challenge is the slow orbit degradation of the host satellite, which precesses toward a terminator orbit. This issue is solved by characterizing the invariant targets with NOAA-16 AVHRR observed radiances that have been referenced to the Aqua Moderate Resolution Imaging Spectrometer (MODIS) calibration using simultaneous nadir overpass (SNO) observations. Another benefit of the NOAA-16 invariant target-modeled reflectance method is that, because of the similarities among the AVHRR spectral response functions, a smaller spectral band adjustment factor is required than when establishing calibrations relative to a non-AVHRR reference instrument. The sensor- and band-specific calibration uncertainties, with respect to the calibration reference, are, on average, 2 percent and 3 percent for channels 1 and 2, respectively. The uncertainties are smaller for sensors that are in afternoon orbits, have longer records, and spend less time in terminator conditions. The multiple invariant targets referenced to Aqua MODIS (MITRAM) AVHRR calibration coefficients are evaluated for individual target consistency, compared against Aqua MODIS/AVHRR SNOs, and selected published calibration gains. The MITRAM and SNO relative calibration biases mostly agree to within 1 percent for channels 1 and 2, respectively. The individual invariant target and MITRAM sensor relative calibration biases are mostly consistent to within 1 percent and 2 percent for channels 1 and 2, respectively. The differences between the MITRAM and other published calibrations are mostly attributed to the reference instrument calibration differences.

Doelling, David R.↗