Search NASA⌕ Search

SEARCH · Search NASA

Results for “radiometer calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Ground-reference site and on-board methods for sensor absolute calibration in the 0.4 to 2.5 micron range

The absolute radiometric calibration uncertainty requirement for several multispectral imaging sensors to be used in the Earth Observing System (EOS) program is +/- 2 percent (one sigma) with respect to the sun. Proposed in-flight absolute calibration methods are reviewed that have this uncertainty as their goal. In particular two methods are described as are recent improvements to them that concern reflectance- and radiance-based calibration using a carefully selected ground reference site. The magnitudes of the error sources are listed. A ratioing radiometer approach to monitoring the reflectance of a solar diffuser used for onboard calibration is discussed.

Slater, P. N.↗

Investigation of passive atmospheric sounding using millimeter and submillimeter wavelength channels

Progress by the Georgia Institute of Technology's Laboratory for Radio-science and Remote Sensing in developing techniques for passive microwave retrieval of water vapor profiles and cloud and precipitation parameters using millimeter and submillimeter wavelength channels is reviewed. Channels of particular interest are in the tropospheric transmission windows at 90, 166, 220, 340, and 410 GHz and centered around the water vapor lines at 183 and 325 GHz. Collectively, these channels have potential application in high-resolution precipitation mapping (e.g., from geosynchronous orbit), remote sensing of cloud and precipitation parameters, including cirrus ice mass, and improved retrieval of water vapor profiles. During the period from January 1, 1994 through June 30, 1994 research activities focussed on calibrating and interpreting data from the Millimeter-Wave Imaging Radiometer (MIR). The MIR was deployed on the NASA ER-2 during the Convective Atmospheric Moisture Experiment (CAMEX, September-October 1993) to obtain the first submillimeter-wave tropospheric imagery of convective precipitations. A 325-GHz radiometer consisted of a submillimeter-wave DSB receiver with three IF channels at +/- 1, 3, and 8.5 GHz, and approximately 14 dB DSB noise figure was successfully operated during these experiments. Activities supported under this grant include a study of the impact of local oscillator reflections from the MIR calibration loads, the development of optimal gain and offset filters for radiometric calibration, and the modeling and interpretation of the MIR 325-GHz data over both clear and cloudy atmospheres. In addition, polarimetric radiometer measurements and modeling for ocean surface and atmospheric cloud-ice studies_were supported.

Gasiewski, Albin J.↗

Radiometric calibration of the Earth observing system's imaging sensors

Philosophy, requirements, and methods of calibration of multispectral space sensor systems as applicable to the Earth Observing System (EOS) are discussed. Vicarious methods for calibration of low spatial resolution systems, with respect to the Advanced Very High Resolution Radiometer (AVHRR), are then summarized. Finally, a theoretical introduction is given to a new vicarious method of calibration using the ratio of diffuse-to-global irradiance at the Earth's surfaces as the key input. This may provide an additional independent method for in-flight calibration.

Slater, P. N.↗

Calibration of the DSCOVR EPIC Visible and NIR Channels using MODIS Terra and Aqua Data and EPIC Lunar Observations

The unique position of the Deep Space Climate Observatory (DSCOVR) Earth Polychromatic Imaging Camera (EPIC) at the Lagrange 1 point makes an important addition to the data from currently operating low Earth orbit observing instruments. EPIC instrument does not have an onboard calibration facility. One approach to its calibration is to compare EPIC observations to the measurements from polar-orbiting radiometers. Moderate Resolution Imaging Spectroradiometer (MODIS) is a natural choice for such comparison due to its well-established calibration record and wide use in remote sensing. We use MODIS Aqua and Terra L1B 1km reflectances to infer calibration coefficients for four EPIC visible and NIR channels: 443, 551, 680 and 780 nm. MODIS and EPIC measurements made between June 2015 and 2016 are employed for comparison. We first identify favorable MODIS pixels with scattering angle matching temporarily collocated EPIC observations. Each EPIC pixel is then spatially collocated to a subset of the favorable MODIS pixels within 25 km radius. Standard deviation of the selected MODIS pixels as well as of the adjacent EPIC pixels is used to find the most homogeneous scenes. These scenes are then used to determine calibration coefficients using a linear regression between EPIC counts/sec and reflectances in the close MODIS spectral channels. We present thus inferred EPIC calibration coefficients and discuss sources of uncertainties. The lunar EPIC observations are used to calibrate EPIC O2 absorbing channels (688 and 764 nm), assuming that there is a small difference between moon reflectances separated by approx.10 nm in wavelength provided the calibration factors of the red (680 nm) and near-IR (780 nm) are known from comparison between EPIC and MODIS.

Geogdzhayev, Igor V.↗

Calibrating Atmospheric Delay for the Cassini Gravitational Wave Experiment

The Cassini spacecraft together with one of the stations of the Deep Space Network (DSN) have been instrumented to carry out extremely precise Doppler tracking that will be used to search for the direct evidence of Gravitational radiation passing through our solar system. The two-way communications link between the ground antenna and the spacecraft constitute an "antenna" for gravitational waves that would perturb the phase of the RF signal in the link. The experiments will be carried out during the long cruise phase of the spacecraft on its journey to Saturn and will be sensitive to gravitational wave perturbations larger than the noise level fluctuations of 3 x 10(exp -15) as measured in the Allan Standard Deviation domain. The use of simultaneous, coherent X- and Ka-Band up and down signals will reduce the errors associated with charged particle fluctuations in the interplanetary medium and Earth's ionosphere to a negligible level. The primary fluctuations in the phase of the signals both to and from the spacecraft are expected to be caused by fluctuations in water vapor in the Earth's atmosphere We have designed and are testing a new atmospheric calibration system (with duplicate components) to sense line-of-sight water vapor and its physical temperature with a goal of calibrating 95% or more of tropospheric path delay fluctuations during the Cassini Gravitational Wave Experiment (GWE). The critical component of the calibration system consists of a newly designed water vapor radiometer having a I degree sensing beamwidth and 0.01 K brightness temperature stability over hour time scales. Auxiliary instrumentation includes a microwave temperature profiler to retrieve the vertical distribution of the vapor physical temperature, and surface meteorology. A detailed error budget has been developed to account for all of the possible sources of error during calibration of the GWE and will be discussed. Two identical calibration systems have been constructed in order to provide capability as well as backup during the actual GWE experiment. We will report on side-by-side testing of the vapor and temperature sensing components of this calibrations system as well as a comparison with a short baseline radio interferometric measurement at our Goldstone complex.

Resch, G. M.↗

Development of a high stability microstrip-based L-band radiometer for ocean salinity measurements.

The development of a microstrip-based L-band Dicke radiometer with the long-term stability required for future ocean salinity measurements to an accuracy of 0.1 psu is presented. This will require the L-band radiometer requirements and configuration to achieve this objective. System configuration and component performance have been evaluated with radiometer test beds at both JPL and GSFC. The GSFC testbed uses a cryogenic chamber that al-lows long-term characterization at radiometric temperatures in the range of 70 - 120 K. The research has addressed several areas including component characterization as a function of temperature and bias, system linearity, optimum noise diode injection calibration and precision temperature control of components. A breadboard radiometer, utilizing microstrip-based technologies, has been built to demonstrate this long-term stability. This system is partially polarimetric providing V, H, -45 and +45 signals. Test results are compared to current and future ocean salinity radiometer requirements to show that the desire performance is possible.

Tanner, Alan B.↗

A TRMM-Based System for Real-Time Quasi-Global Merged Precipitation Estimates

A new processing system has been developed to combine IR and microwave data into 0.25 degree x 0.25 degree gridded precipitation estimates in near-real time over the latitude band plus or minus 50 degrees. Tropical Rainfall Measuring Mission (TRMM) Microwave Imager (TMI) precipitation estimates are used to calibrate Special Sensor Microwave/Imager (SSM/I) estimates, and Advanced Microwave Sounding Unit (AMSU) and Advanced Microwave Scanning Radiometer (AMSR) estimates, when available. The merged microwave estimates are then used to create a calibrated IR estimate in a Probability-Matched-Threshold approach for each individual hour. The microwave and IR estimates are combined for each 3-hour interval. Early results will be shown, including typical tropical and extratropical storm evolution and examples of the diurnal cycle. Major issues will be discussed, including the choice of IR algorithm, the approach for merging the IR and microwave estimates, extension to higher latitudes, retrospective processing back to 1999, and extension to the GPCP One-Degree Daily product (for which the authors are responsible). The work described here provides one approach to using data from the future NASA Global Precipitation Measurement program, which is designed to provide Jill global coverage by low-orbit passive microwave satellites every three hours beginning around 2008.

Starr, David OC.↗

SeaWiFS Postlaunch Technical Report Series: The SeaWiFS Transfer Radiometer (SXR) - Volume 1

The SeaWiFS Transfer Radiometer (SXR) was built for the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Project as part of an Interagency Agreement with the National Aeronautics and Space Administration (NASA). The SXR is a multichannel radiometer designed to verify and compare measurements of spectral radiance at six discrete wavelengths in the visible and near infrared for various calibration sources in the SeaWiFS Project. In addition, the SXR is used to compare these sources to standards of spectral radiance maintained at the National Institute of Standards and Technology (NIST). The SXR was designed, built, and thoroughly characterized in the Optical Technology Division at NIST. A unique optical design provides six independent optical paths, each equipped with a temperature stabilized interference filter and silicon photodiode. A separate beam path through the input lens is used to visually align the SXR. The entrance windows for each channel overlap at the source, with each channel sampling a unique solid angle within the field of view of the SXR; this allows for simultaneous sampling of all channels. The combined standard relative uncertainty of spectral radiance measurements with the SXR is estimated to be between 0.6% and 1.3%. This report describes the design and construction of the SXR in detail, and gives the results of the optical characterization and calibrations done at NIST. The SXR has been used for several intercomparisons which include several SeaWiFS Intercalibration Round-Robin Experiments (SIRREXs); those done at the Marine Optical Buoy (MOBY) laboratories in Honolulu, Hawaii; at the NEC Corporation in Yokohama, Japan; and Orbital Sciences Corporation (OSC) in Germantown, Maryland. Thorough optical characterization and calibration of the SXR was essential to the successful application of the radiometer for these measurements.

Johnson, B. Carol↗

SeaWiFS Postlaunch Technical Report Series: The SeaWiFS Transfer Radiometer (SXR) - Volume 1

The SeaWiFS Transfer Radiometer (SXR) was built for the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Project as part of an Interagency Agreement with the National Aeronautics and Space Administration (NASA). The SXR is a multichannel radiometer designed to verify and compare measurements of spectral radiance at six discrete wavelengths in the visible and near infrared for various calibration sources in the SeaWiFS Project. In addition, the SXR is used to compare these sources to standards of spectral radiance maintained at the National Institute of Standards and Technology (NIST). The SXR was designed, built, and thoroughly characterized in the Optical Technology Division at NIST. A unique optical design provides six independent optical paths, each equipped with a temperature stabilized interference filter and silicon photodiode. A separate beam path through the input lens is used to visually align the SXR. The entrance windows for each channel overlap at the source, with each channel sampling a unique solid angle within the field of view of the SXR; this allows for simultaneous sampling of all channels. The combined standard relative uncertainty of spectral radiance measurements with the SXR is estimated to be between 0.6% and 1.3%. This report describes the design and construction of the SXR in detail, and gives the results of the optical characterization and calibrations done at NIST. The SXR has been used for several intercomparisons which include several SeaWiFS Intercalibration Round-Robin Experiments (SIRREXs); those done at the Marine Optical Buoy (MOBY) laboratories in Honolulu, Hawaii; at the NEC Corporation in Yokohama, Japan; and Orbital Sciences Corporation (OSC) in Germantown, Maryland. Thorough optical characterization and calibration of the SXR was essential to the successful application of the radiometer for these measurements.

Hooker, Stanford B.↗

CERES FM-5 on the NPP Spacecraft: Continuing the Earth Radiation Budget Climate Data Record

The Clouds and the Earth's Radiant Energy System (CERES) Flight Model-5 (FM-5) instrument will fly on the NPOESS Preparatory Project (NPP) spacecraft, which has a launch-readiness date in June, 2010. This mission will continue the critical Earth Radiation Budget Climate Data Record (CDR) begun by the Earth Radiation Budget Experiment (ERBE) instruments in the mid 1980 s and continued by the CERES instruments currently flying on the EOS Terra and Aqua spacecraft. Ground calibrations have been completed for FM-5 and the instrument has been delivered for integration to the spacecraft Rigorous pre-launch ground calibration is performed on each CERES unit to achieve an accuracy goal of 1% for SW flux and 0.5% for outgoing LW flux. Any ground to flight or in-flight changes in radiometer response is monitored using a protocol employing both onboard and vicarious calibration sources and experiments. Recent studies of FM-1 through FM-4 data have shown that the SW response of space based broadband radiometers can change dramatically due to optical contamination. With these changes having most impact on optical response to blue-to UV radiance, where tungsten lamps are largely devoid of output, such changes are hard to monitor accurately using existing on-board sources. This paper outlines the lessons learned on the existing CERES sensors from 30+ years of flight experience and presents a radiometric protocol to be implemented on the FM-5 instrument to ensure that its performance exceeds the stated calibration and stability goals.

Priestly, Kory↗

Design of an atmospheric sounding radiometer for the GOES meteorological satellite system

An advanced version of the visible infrared spin scan radiometer onboard U.S. geostationary operational environmental satellites was developed to add a vertical dimension to the instrument's infrared atmospheric images. Through the addition of twelve selectable narrow band filters and more precise in-flight calibration of the infrared detectors, the VISSR atmospheric sounder (VAS) will provide increased data to help determine the Earth's atmospheric temperature and water vapor distribution. The radiometer design, filter wheel, calibration shutter mechanisms, and their preflight test performance are discussed.

Jensen, R. G.↗

A plan for the characterization, calibration, and evaluation of LAPR-2

A new airborne Linear Array Pushbroom Radiometer (LAPR-II) was built. LAPR-II will use linear arrays of silicon detectors to acquire four channels of digital image data for spectral bands within the visible and near infrared portions of the spectrum (0.4 - 1.0 micrometers). The data will be quantized to 10 bits, and spectral filters for each channel will be changeable in flight. The instrument will initially be flown aboard a NASA/Wallops' aircraft, and off nadir pointing of LAPR-II will be possible. Together, the instrument and its platform will provide a flexible readily available source of digital image data for scientific experiments. If LAPR-II is to serve as a precise scientific instrument, the instrument's characteristics must be quantitatively described and the data must be calibrated with respect to absolute radiometric units. The LAPR-II is described and the work required to characterize the instrument's spectral response, radiometric response, and spatial resolution and to calibrate the response from the many detectors per array is outlined.

Ilrons, J. R.↗

On the Use of Deep Convective Clouds to Calibrate AVHRR Data

Remote sensing of cloud and radiation properties from National Oceanic and Atmospheric Administration (NOAA) Advanced Very High Resolution Radiometer (AVHRR) satellites requires constant monitoring of the visible sensors. NOAA satellites do not have onboard visible calibration and need to be calibrated vicariously in order to determine the calibration and the degradation rate. Deep convective clouds are extremely bright and cold, are at the tropopause, have nearly a Lambertian reflectance, and provide predictable albedos. The use of deep convective clouds as calibration targets is developed into a calibration technique and applied to NOAA-16 and NOAA-17. The technique computes the relative gain drift over the life-span of the satellite. This technique is validated by comparing the gain drifts derived from inter-calibration of coincident AVHRR and Moderate-Resolution Imaging Spectroradiometer (MODIS) radiances. A ray-matched technique, which uses collocated, coincident, and co-angled pixel satellite radiance pairs is used to intercalibrate MODIS and AVHRR. The deep convective cloud calibration technique was found to be independent of solar zenith angle, by using well calibrated Visible Infrared Scanner (VIRS) radiances onboard the Tropical Rainfall Measuring Mission (TRMM) satellite, which precesses through all solar zenith angles in 23 days.

Doelling, David R.↗

Impact of Microwave Sounder Calibration on Precipitation for the Global Precipitation Measurement Mission

Cross-track microwave sounders make up a significant percentage of the radiometers included in the Global Precipitation Measurement (GPM) constellation. Therefore, it is important to properly assess the calibration of each sounder instrument and to understand the impact of the calibration on the derived precipitation rates. This ensures an accurate precipitation product is produced for the entire constellation. This paper will use data from past and current microwave sounders to show how offsets in the calibration can impact the precipitation using the GPM Level 2 GPROF algorithm. Potential improvements to the instrument calibration will be assessed by analyzing how they would positively impact the precipitation trends and agreement among the constellation sensors.

Microwave radiometry↗

VIIRS Reflective Solar Band Radiometric and Stability Evaluation Using Deep Convective Clouds

This work takes advantage of the stable distribution of deep convective cloud (DCC) reflectance measurements to assess the calibration stability and detector difference in Visible Infrared Imaging Radiometer Suite (VIIRS) reflective bands. VIIRS Sensor Data Records (SDRs) from February 2012 to June 2015 are utilized to analyze the long-term trending, detector difference, and half angle mirror (HAM) side difference. VIIRS has two thermal emissive bands with coverage crossing 11 microns for DCC pixel identification. The comparison of the results of these two processing bands is one of the indicators of analysis reliability. The long-term stability analysis shows downward trends (up to approximately 0.4 per year) for the visible and near-infrared bands and upward trends (up to 0.5per year) for the short- and mid-wave infrared bands. The detector difference for each band is calculated as the difference relative to the average reflectance overall detectors. Except for the slightly greater than 1 difference in the two bands at 1610 nm, the detector difference is less than1 for other solar reflective bands. The detector differences show increasing trends for some short-wave bands with center wavelengths from 400 to 600 nm and remain unchanged for the bands with longer center wavelengths. The HAM side difference is insignificant and stable. Those short-wave bands from 400 to 600 nm also have relatively larger HAM side difference, up to 0.25.Comparing the striped images from SDR and the smooth images after the correction validates the analyses of detector difference and HAM side difference. These analyses are very helpful for VIIRS calibration improvement and thus enhance product quality

VIIRS↗

JPSS-2 VIIRS Day-Night Band Pre-launch Radiometric Calibration and Performance

The first two flight models of the Visible Infrared Imaging Radiometer Suite (VIIRS) instrument continue to operate onboard the Suomi National Polar-orbiting Partnership (S-NPP) and NOAA-20 spacecrafts. The third flight model is set to be launched as one of a complement of instruments onboard the Joint Polar–orbiting Satellite System-2 (JPSS-2) satellite. In addition to its 14 reflective solar bands and 7 thermal emissive bands, VIIRS has a unique Day-Night Band (DNB). The DNB is a panchromatic imager based on CCD detectors, covering a spectral range of about 500 – 900 nm. The DNB is made up of three gain stages, allowing the sensor to operate over a large dynamic range (3×10(−9) - 0.02 W⁄cm(2)/sr). As part of VIIRS pre-launch ground testing, the DNB has been characterized to determine its functionality and performance under a space-like environment. The results are compared against the design specification and to previous VIIRS flight models when applicable. This paper presents a comprehensive summary of the VIIRS DNB prelaunch testing and the results of radiometric and spectral assessments. The expected impact to on-orbit operations and calibrated data products are also discussed.

Infrared Imaging Radiometer Suite (VIIRS)↗

Interim Calibration Report for the SMMR Simulator

The calibration data obtained during the fall 1978 Nimbus-G underflight mission with the scanning multichannel microwave radiometer (SMMR) simulator on board the NASA CV-990 aircraft were analyzed and an interim calibration algorithm was developed. Data selected for the analysis consisted of in flight sky, first-year sea ice, and open water observations, as well as ground based observations of fixed targets with varied temperatures of selected instrument components. For most of the SMMR channels, a good fit to the selected data set was obtained with the algorithm.

Gloersen, P.↗

Assess Calibration Consistency of MODIS and AVHRR Thermal Infrared Bands Using SNO Observations Corrected for Atmospheric Effects

Monitoring environmental changes from space requires extremely well-calibrated observations to achieve the necessary high accuracy and stability. The calibration differences between the Moderate Resolution Imaging Spectroradiometer (MODIS) and the Advanced Very High Resolution Radiometer (AVHRR) thermal bands provide a valuable quality assessment of the instrument performance. This letter compares the calibration differences between the Aqua MODIS and NOAA-18 AVHRR bands at 11.0 and 12.0 /Lm using simultaneous nadir overpass observations obtained in nearly parallel orbits. Impacts due to the relative spectral-response differences between the two sensors are estimated by MODTRAN simulations with real-time atmospheric profiles of temperature, water vapor, atmospheric pressure and ozone, and surface skin temperatures. Results show that the temperature difference after the removal of atmospheric impacts is within 0.30 K (or 0.40% in radiance) across the effective calibration range (or the 1l.0 l'm band/channel. For the 12.0 pm band, the differences are OAO K (or 0.50%) at the typical radiance and up to 0.70 K (or 0.90%) close to the maximum radiance, indicating an excellent calibration consistency between MODIS and AVHRR for both bands.

Wu, Aisheng↗