Search NASA⌕ Search

SEARCH · Search NASA

Results for “representative sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Precipitation and Latent Heating Distributions from Satellite Passive Microwave Radiometry. Part II: Evaluation of Estimates Using Independent Data

Rainfall rate estimates from spaceborne microwave radiometers are generally accepted as reliable by a majority of the atmospheric science community. One of the Tropical Rainfall Measuring Mission (TRMM) facility rain-rate algorithms is based upon passive microwave observations from the TRMM Microwave Imager (TMI). In Part I of this series, improvements of the TMI algorithm that are required to introduce latent heating as an additional algorithm product are described. Here, estimates of surface rain rate, convective proportion, and latent heating are evaluated using independent ground-based estimates and satellite products. Instantaneous, 0.5 deg. -resolution estimates of surface rain rate over ocean from the improved TMI algorithm are well correlated with independent radar estimates (r approx. 0.88 over the Tropics), but bias reduction is the most significant improvement over earlier algorithms. The bias reduction is attributed to the greater breadth of cloud-resolving model simulations that support the improved algorithm and the more consistent and specific convective/stratiform rain separation method utilized. The bias of monthly 2.5 -resolution estimates is similarly reduced, with comparable correlations to radar estimates. Although the amount of independent latent heating data is limited, TMI-estimated latent heating profiles compare favorably with instantaneous estimates based upon dual-Doppler radar observations, and time series of surface rain-rate and heating profiles are generally consistent with those derived from rawinsonde analyses. Still, some biases in profile shape are evident, and these may be resolved with (a) additional contextual information brought to the estimation problem and/or (b) physically consistent and representative databases supporting the algorithm. A model of the random error in instantaneous 0.5 deg. -resolution rain-rate estimates appears to be consistent with the levels of error determined from TMI comparisons with collocated radar. Error model modifications for nonraining situations will be required, however. Sampling error represents only a portion of the total error in monthly 2.5 -resolution TMI estimates; the remaining error is attributed to random and systematic algorithm errors arising from the physical inconsistency and/or nonrepresentativeness of cloud-resolving-model-simulated profiles that support the algorithm.

Yang, Song↗

Analysis of Automated Fault Detection and Diagnosis Records as an Indicator of HVAC Fault Prevalence: Methodology and Preliminary Results

Faults in commercial buildings can cause energy waste and other performance problems such as reduced occupant comfort, reduced equipment longevity, and increased noise. However, it is currently unknown how commonly faults occur in different equipment types. A method has been developed to estimate the prevalence of faults in air handling units, air terminal units, and rooftop units. This method includes two types of data. The first is data from several automated fault detection and diagnostics (AFDD) software technologies. This type of data provides a large sample that represents a wide range of building types, geographical locations, and equipment types. It includes fault diagnoses from thousands of buildings around the United States, as well as anonymized metadata describing the building and equipment characteristics. The number of fault records is in the order of 107. However, despite the size and richness of the data sample, this data contains some degree of inaccuracy, i.e., false positive and false negative findings. Therefore, the study includes a second type of data, coming from manual inspection of buildings that have had the same AFDD methods applied to them (from the commercial AFDD offerings). Since the field tests are conducted in buildings with AFDD-generated fault prevalence data, they can be combined with the larger sample size to provide insight into the potential biases or lower sensitivity of the AFDD data. Once a library of fault prevalence data is built, it will be studied to provide further insight into the drivers of fault prevalence, for example, whether prevalence is correlated with building type, geographical location (which is tied to climate and to utility rates), building size, etc. This paper describes the methods developed for this study and illustrates them with preliminary data. It discusses some of the challenges of harmonizing disparate outputs from multiple AFDD vendors, application of a unifying fault taxonomy, and fault prevalence metrics.

Ebrahimi Fakhar, Amir↗

AutoBEM: A scalable framework for nationwide building energy simulation and retrofit evaluation in the United States

This paper presents AutoBEM, an integrated, automated framework for nationwide building energy modeling and retrofit evaluation in the United States. Unlike prior UBEM platforms that either rely primarily on representative stock sampling or operate at city scale, AutoBEM automates the generation of building-resolved, physics-based EnergyPlus/OpenStudio simulation models at national scale using GIS-derived geometry, prototype-based assumptions, and standardized scalable workflows. Leveraging the Model America dataset and high-performance computing, AutoBEM generates and simulates energy models for 122.9 million buildings, representing 97.8% of the U.S. building stock. These models are being made publicly and freely available as the Model America v1.0 (MAv1) dataset. AutoBEM supports detailed, building-level assessments of energy consumption, CO2 emissions, and post-processed anthropogenic heat emissions (AHE), and evaluates 151 energy conservation measures (ECMs) using localized utility pricing and building characteristics. In addition, AutoBEM incorporates both typical and future climate conditions through integration with Typical Meteorological Year (TMY) and Future TMY (fTMY) weather data derived from IPCC scenarios. In a case study of Phoenix, Arizona, AutoBEM identified several high-efficiency HVAC upgrades and selected envelope measures with short modeled payback periods (1.5 years) for certain building types and standards. Simulations under future climate scenarios (SSP5–RCP8.5) project an 11.3% increase in electricity use and a 32% reduction in natural gas demand by 2100, underscoring the need for climate-adaptive retrofit planning. By enabling reproducible, bottom-up, and location-specific analysis at scale, AutoBEM provides a step toward a national digital twin of the built environment and supports data-driven screening and planning for decarbonization, resilience, and energy equity.

Li, Hang [ORNL] (ORCID:0000000306001920)↗

Derivation of mid-infrared (5-25 microns) optical constants of some silicates and palagonite

Recent reports concerning the mid-infrared reflectance properties of silicates coupled with recent observations of the Earth and other planets in the mid-infrared and the planned Thermal Emission Spectrometer scheduled as an instrument to be included on the Mars Observer all illustrate the increasing interest in the optical properties of materials in the mid-infrared and their direct application to remote sensing observations of other planetary surfaces. As the laboratory and observational data increase they will ultimately be modeled to aid in the understanding of the composition mineralogy, and distribution of the surface and atmospheric constituents on these bodies. In order to facilitate such quantitative analyses, knowledge regarding the optical constants (real (n) and imaginary (k) indices of refraction) of a wide variety of pertinent materials is required. Examples of the application of such quantitative analyses to the interpretation of Martian surface and atmospheric constituents, based on the optical constants of minerals, are presented. This study was initially conceived in order to aid in the interpretation of Martian surface and atmospheric aerosol mineralogy. As a result, the minerals included are biased toward samples which represent hydrated and hydroxylated silicates. These include the Al and Mg end members of the 1:1 layer lattice silicates, kaolinite and serpentine, respectively; an Al-bearing 2:1 layer lattice silicate, pyrophyllite; the Mg and Al smectite clays saponite and montmorillonite, respectively; and a palagonite, typically a poorly characterized alteration product of basaltic glass. The reflectivities of all samples were determined by placing them at the focus of a near-normal reflective attachment located in a Fourier transform spectrometer. To derive the optical constants of a material as a function of wavelength, researchers used the commonly employed technique of dispersion analysis.

Roush, T. L.↗

The abundances of isotopes in the cosmic radiation

Studies of the isotopic composition of nuclei in the cosmic radiation are reviewed, including abundances of the isotopes of elements from H to Ni, together with their implications for cosmic ray origin, acceleration, and transport in the Galaxy. The review focuses on determinations of the composition of cosmic ray source material, and the extent to which the isotopic composition of this material is different from, or similar to, typical solar system material and other samples of Galactic matter. Theoretical models that have been advanced to explain the observed overabundance of neutron-rich isotopes in cosmic rays are described. Also discussed are studies of various radioactive clocks that record the time-scales associated with the nucleosynthesis, acceleration, and transport of cosmic ray nuclei, and studies of the so-called anomalous cosmic ray component, thought to represent a sample of the neutral interstellar medium.

Mewaldt, R. A.↗

Acinetobacter pollinis sp. nov., Acinetobacter baretiae sp. nov. and Acinetobacter rathckeae sp. nov., isolated from floral nectar and honey bees

A detailed evaluation of eight bacterial isolates from floral nectar and animal visitors to flowers shows evidence that they represent three novel species in the genus Acinetobacter . Phylogenomic analysis shows the closest relatives of these new isolates are Acinetobacter apis , Acinetobacter boissieri and Acinetobacter nectaris , previously described species associated with floral nectar and bees, but high genome-wide sequence divergence defines these isolates as novel species. Pairwise comparisons of the average nucleotide identity of the new isolates compared to known species is extremely low (<83 %), thus confirming that these samples are representative of three novel Acinetobacter species, for which the names Acinetobacter pollinis sp. nov., Acinetobacter baretiae sp. nov. and Acinetobacter rathckeae sp. nov. are proposed. The respective type strains are SCC477 T (=TSD-214 T =LMG 31655 T ), B10A T (=TSD-213 T =LMG 31702 T ) and EC24 T (=TSD-215 T =LMG 31703 T =DSM 111781 T ).

59 BASIC BIOLOGICAL SCIENCES↗

Comparisons of Instantaneous TRMM Ground Validation and Satellite Rain Rate Estimates at Different Spatial Scales

This study provides a comprehensive inter-comparison of instantaneous rain estimates from the two rain sensors aboard the TRMM satellite with ground data from thee designated Ground Validation Sites: Kwajalein Atoll, Melbourne, Florida and Houston, Texas. The satellite rain retrievals utilize rain observations collected by the TRMM microwave imager (TMI) and the Precipitation Radar (PR) aboard the TRMM satellite. Three standard instantaneous rain products are the generated from the rain information retrieved from the satellite using the TMI, PR and Combined (COM) rain algorithms. The validation data set used in this study was obtained from instantaneous rain rates inferred from ground radars at each GV site. The first comparison used 0.5(sup 0) x 0.5(sup 0) gridded data obtained from the TRMM 3668 product, and similarly gridded GV data obtained from ground-based radars. The comparisons were made at the same spatial and temporal scales in order to eliminate sampling biases in our comparisons. An additional comparison was made by averaging rain rates for the PR, COM and GV estimates within each TMI footprint (approx. 150 square kilometers). For this analysis, unconditional mean rain rates from PR, COM and GV estimates were calculated within each TMI footprint that was observed within 100 km from the respective GV site (and also observed by the PR). This analysis used all the available matching data from the period 1999-2004, representing a sample size of over 50,000 footprints for each site. In the first analysis our results showed that all of the respective rain rate estimates agree well, with some exceptions. The more salient differences were associated with heavy rain events in which one or more of the algorithms failed to properly retrieve these extreme events. Also, it appears that there is a preferred mode of precipitation for TMI rain rates at or near 2 mm per hour over the ocean. This mode was noted over ocean areas of Melbourne, Florida and Kwajalein, Republic of the Marshall Islands, and is shown to exist in TRMM tropical-global ocean areas as well. Further research by algorithm developers is needed to explain or justify the seemingly errant observed probability distributions.

Wolff, David B.↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Outgassing tests on iras solar panel samples

Several outgassing tests were carried out on representative solar panel samples in order to determine the extent of contamination that could be expected from this source. The materials for the construction of the solar panels were selected as a result of contamination obtained in micro volatile condensable materials tests.

Premat, G.↗

Verification of land cover maps from LANDSAT data

The application of cluster sampling to verifying the accuracy of maps derived from digital data is discussed. Variants of the cluster sampling technique were used in large scale assessments for areas in excess of one million hectares. Three types of classification errors are possible: commission errors, omission errors, and overall error classification. Commission errors for a particular cover type occur when pixels are classified as that cover type but are found to be some other cover type when the field is checked. Omission errors occur when pixels of fields already visited and known to be of a particular cover type, are classified as some other cover type. Overall error is the proportion of pixels incorrectly classified, without regard to omission or commission. Since the classified image represents the sampling frame, sampling for accuracy assessment was designed to estimate commission error. However, the sample can also provide useful estimates of omission and overall error. Assessment for Alaska, Arizona, and Oklahoma are presented.

Linden, D. S.↗

Development and performance of INCONEL® alloy 740H® seam-welded piping

INCONEL® alloy 740H® is an age-hardenable nickel-based alloy approved for pressure vessels and piping within ASME Section I, VIII, and B31.1. Currently, the code applies a weld strength reduction factor (WSRF) of 0.7 to the allowable stresses for longitudinal seam welds in the time dependent creep regime. In this work, a full-scale seam weld was successfully produced using typical industrial practices. The component was solution heat-treated and aged after fabrication to improve the performance of the weldment. Tensile, bend, impact, and low-cycle fatigue tests showed the component met all the specification requirements and elevated temperature properties were within base metal expectations with failures predominately in the weld metal. Long-term creep tests, including large samples more representative of the entire weldment, were fabricated and tested to times in excess of 10,000 h at multiple temperatures. Analysis of the creep data supports a WSRF of 0.9 for the solution annealed + aged weldments in contrast to the WSRF of 0.7 currently applied to welded + aged weldments. Metallurgical analysis shows that the solution annealing causes recrystallization of the weld metal and reduces the chemical compositional and microstructural gradients in the weldments resulting in acceptable short-term performance. In long-term creep, evidence for coarsened zones in the weldments due to discontinuous coarsening reactions were identified as the mechanism leading to accelerated creep damage formation in the weld metal and sample failure.

14 SOLAR ENERGY↗

A simulation survey of galaxy interactions

Many carefully selected samples of interacting galaxies have been observed extensively in attempts to clarify whether interaction produces activity in galaxies. Because the sample members represent a wide range of encounter parameters and times, one can then study whether there are correlations between observable encounter features and, for example, Seyfert activity. On the other hand, in theoretical studies, simulations typically deal with either time-consuming detailed modelling of single galaxy pairs or tracing a few model encounters over time. The authors extend the observational survey approach by combining it with a simulation survey. The authors are conducting a survey of model encounters, covering the most important encounter parameters over a wide range. Some parameters, such as companion structure and initial velocity, are demonstratably less important and can be ignored in a first pass. The parameter range must be richly enough sampled so that the authors can evaluate the uniqueness of the observable morphology and velocity structure of the resulting simulated pairs to diagnose unobservable companion orbit parameters. They are using a self-gravitating polar n-body code run on the Cray X-MP at the Alabama Supercomputer Network. For each simulation, the authors have stellar and gas distributions predicted over, typically, a billion years, along with information on gas motions within the disk and any material captured by the companion or lost to the system. Features of disturbed spiral galaxies are sensitive enough to time and encounter parameters so that a match of the simulation survey results to observations can be applied as starting points to infer unobservable orbital or system parameters in actual sample members. This should enable them to examine whether interesting observed properties (Seyfert activity, nuclear star-formation rate) are functions of unobservable dynamical properties which characterize each encounter. Any correlations (or lack of some expected ones) will provide strong clues as to how or whether these phenomena are related to interactions. Aside from its use with such observed samples, this survey should greatly speed determination of initial orbital parameters for more detailed subsequent simulations of individual systems.

Byrd, Gene G.↗

Cryogenic Shrouds for Testing Thermal-Insulation Panels

Cryogenic shrouds have been designed and built for use in thermomechanical testing of samples of thermalinsulation panels on cryogenic vessels. In the original application for which these shrouds were specifically designed, the samples are representative of the large-area thermal-insulation panels on the space-shuttle external tanks that hold liquid hydrogen and liquid oxygen, and the purpose of the testing is to demonstrate the ability of bonded layers in the panels to resist delamination under a combination of applied uniaxial mechanical loads and realistic operational temperatures. Presumably, the shrouds and the tests performed by use of them could be modified to enable similar evaluation of thermomechanical properties of thermal-insulation panels for cryogenic vessels other than the external tanks of the space shuttles. The shrouds are required to enable maintenance of required temperatures on the inner and outer surfaces of the thermal-insulation-panel samples, to enable visual observation of the outer surfaces of the samples, and not to introduce any measurable loads into the panels. For each panel sample, there are two shrouds: one to be mounted on the inner surface (the surface that would be in contact with a tank containing a cryogenic liquid during normal use) and one to be mounted on the outer surface (the surface that would be exposed to ambient air or other warmer environment during normal use). The shrouds for testing specimens of thermal-insulation- panels for the liquid-hydrogen tank are made largely of titanium; the shrouds for testing specimens of thermal- insulation-panels for the liquid-oxygen tank are made largely of an aluminum- lithium alloy. The specific temperature requirements are the following: The inner shroud must make it possible to maintain a temperature of 321 degrees F (196 degrees C) [the approximate temperature of liquid nitrogen] or 453 F (about 269 C) [the approximate temperature of liquid helium] on the inner face of the sample. The outer shroud must make it possible to maintain a temperature between 30 degrees and 0 degrees F (between about 34 degrees and about 18 degrees C) on the outer surface of the sample by blowing a cryogenic gas or missile grade air along that surface. To enable viewing of the outer surface of the sample during testing, the outer shroud includes a window comprising two layers of poly(methyl methacrylate) with a gap between them to reduce fogging. To ensure that the shrouds do not introduce any measurable loads into a panel specimen, the shrouds are cushioned on the specimen by seals made of a fluoropolymer-membrane/fabric composite material and are held in place on the specimen by means of symmetrically placed clamps with poly(tetrafluoroethylene) pads. Instrumentation ports for thermocouples and strain gauges used in the tests are incorporated into the shrouds.

Norris, Jeffrey↗

Savannah River Site High Level Radioactive Waste Tank Sample Thermolytic Hydrogen Generation - 20346

To support the revision of flammability calculations and controls for the Savannah River Site (SRS) High-Level Radioactive Waste (HLW) tanks, Savannah River National Laboratory (SRNL) conducted laboratory measurements with the goal of quantifying hydrogen produced in HLW by non-radiolytic chemical reactions (i.e., thermolysis). Testing was performed with HLW tank supernate samples that represented a cross section of types of waste at SRS, including tanks that store typical evaporator concentrate, dissolved salt-cake, dilute recycle stream from the Defense Waste Processing Facility (DWPF), evaporator concentrate of the recycle stream from DWPF, fresh waste from the canyon separations facility, and waste that has been through salt processing cesium removal. Non-radioactive simulant testing included the classes of organic compounds historically introduced into the HLW tanks that were recently shown to be the most active toward the thermolytic generation of hydrogen. The reaction rate equations developed for thermolytic hydrogen generation from each class of organic compound showed direct proportionality to organic compound concentration and hydroxide concentration. Simulant testing identified that highly concentrated waste with high hydroxide concentration had the highest rates of thermolytic hydrogen generation. Using the radioactive tank sample thermolysis measurements at high temperatures and the mechanistic salt dependence of the simulant models, a global model was developed for tank waste thermolytic hydrogen generation as a function of total organic carbon content of SRS HLW. Through the primary functionality of the global model (organic carbon and free hydroxide concentration), the relative reactivity of the organic carbon in the waste was quantified. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Debris Flux Comparisons From The Goldstone Radar, Haystack Radar, and Hax Radar Prior, During, and After the Last Solar Maximum

The continual monitoring of low Earth orbit (LEO) debris environment using highly sensitive radars is essential for an accurate characterization of these dynamic populations. Debris populations are continually evolving since there are new debris sources, previously unrecognized debris sources, and debris loss mechanisms that are dependent on the dynamic space environment. Such radar data are used to supplement, update, and validate existing orbital debris models. NASA has been utilizing radar observations of the debris environment for over a decade from three complementary radars: the NASA JPL Goldstone radar, the MIT Lincoln Laboratory (MIT/LL) Long Range Imaging Radar (known as the Haystack radar), and the MIT/LL Haystack Auxiliary radar (HAX). All of these systems are highly sensitive radars that operate in a fixed staring mode to statistically sample orbital debris in the LEO environment. Each of these radars is ideally suited to measure debris within a specific size region. The Goldstone radar generally observes objects with sizes from 2 mm to 1 cm. The Haystack radar generally measures from 5 mm to several meters. The HAX radar generally measures from 2 cm to several meters. These overlapping size regions allow a continuous measurement of cumulative debris flux versus diameter from 2 mm to several meters for a given altitude window. This is demonstrated for all three radars by comparing the debris flux versus diameter over 200 km altitude windows for 3 nonconsecutive years from 1998 through 2003. These years correspond to periods before, during, and after the peak of the last solar cycle. Comparing the year to year flux from Haystack for each of these altitude regions indicate statistically significant changes in subsets of the debris populations. Potential causes of these changes are discussed. These analysis results include error bars that represent statistical sampling errors, and are detailed in this paper.

Stokely, C. L.↗

MBARI-WEC September and October 2022 Field Data

This data is needed to simulate a model of the MBARI-WEC (Monterey Bay Aquarium Research Institute, Wave Energy Converter device) in a simulation environment (e.g. Gazebo) for 56 observation dates in the time between September and October 2022, and to compare the simulation outputs to the corresponding field data of the physical MBARI-WEC. There were 50 observations chosen in Sept and 6 observations in Oct. To help understand terms below, a summary of the system can be found at the github link in the downloads section below. The Gazebo MBARI-WEC model is also provided, should users wish to simulate using this platform. There are 4 *mat files included. ................................................................................................................................................................................................................................... Spectrum and Simulation Inputs: September2022_spectrum_siminputs.mat and October2022_spectrum_siminputs.mat has data needed for simulation inputs in table format. These include the ocean spectrum for an observation and operating parameters of the MBARI-WEC during that observation. They are organized as rows representing an observation and columns representing data. For example, for the September *mat there are 50 rows. The first 7 columns are Datetime, sig_waveheight, peak_period, mean_period, heaveconedoor_status, pistonpos_mean, and scale_factor: - Datetime is the date and time the observation occurred in PST - sig_waveheight is the significant wave height of the ocean spectrum during that observation in meters - peak_period is the peak period of the ocean spectrum during that observation in seconds - mean_period is the mean period of the ocean spectrum during that observation in seconds - heaveconedoor_status is the status of the heave cone doors where 0 represents the doors are open and 1 represents they are closed - pistonpos_mean is the mean position of the PTO ram (piston) in meters - scale_factor is an additional factor of 0.5 --1.4 applied to a default damping relationship The next columns are data needed to represent the ocean spectrum. First are the frequencies [Hz] labeled as "f0-f38", then the variance density [m2/Hz] labeled as "vardens0-vardens38". October2022_spectrum_siminputs.mat follows as a similar format as above, but includes a larger amount of ocean spectrum frequencies and variance density elements. ................................................................................................................................................................................................................................... Field data: The field data is found in MBARIWEC_septdata.mat and MBARIWEC_octdata.mat for the observations of September and October, respectively. These contain data in a struct format. The struct contains the following fields for each observation: PC_BattCurr, PC_LoadCurr, PC_RPM, PC_Voltage, SC_Range, SC_Velocity, DateTime, where: - PC_BattCurr is the current flowing to or from the onboard batteries in Amps - PC_LoadCurr is the current flowing to the load dump in Amps - PC_RPM is the electric/hydraulic motor shaft speed (directly coupled) in RPM - PC_Voltage is the bus voltage at the power converter in Volts - SC_Range is the PTO ram (piston) position in meters where 0 is fully retracted and 2.03 is fully extended - SC_Velocity is the PTO ram (piston) velocity in meters/sec - DateTime is the date and time of the sampled field data in each observation in PST - Electric Power is equal to: PC_Voltage*(PC_BattCurr + PC_LoadCurr) in Watts For example, upon loading MBARIWEC_octdata.mat, the aforementioned fields would be loaded, each with {6x1} cells for the 6 observations chosen in October. Within the first cell of e.g. SC_Range would be sampled data representing the field data of the MBARIWEC PTO piston position for say, one hour, of the first October observation. The corresponding field DateTime would...

16 TIDAL AND WAVE POWER↗

Determining Multi-Component Phase Diagrams with Desired Characteristics Using Active Learning

Herein, we demonstrate how to predict and experimentally validate phase diagrams for multi-component systems from a high-dimensional virtual space of all possible phase diagrams involving several elements based on small existing experimental data. The experimental data for bulk phases for known systems represents a sampling from this space, and screening the space allows multi-component phase diagrams with given design criteria to be built. This approach uses machine learning methods to predict phase diagrams and Bayesian experimental design to minimize experiments for refinement and validation, all within an active learning loop. The approach is proven by predicting and synthesizing the ferroelectric ceramic system (1-ω)(Ba 0.61 Ca 0.28 Sr 0.11 TiO 3 )-ω(BaTi 0.888 Zr 0.0616 Sn 0.0028 Hf 0.0476 O 3 ) with a relatively high transition temperature and triple point, as well as the NiTi-based pseudo-binary phase diagram (1-ω)(Ti 0.309 Ni 0.485 Hf 0.20 Zr 0.006 )-ω(Ti 0.309 Ni 0.485 Hf 0.07 Zr 0.068 Nb 0.068 ) designed for high transition temperature (ω ≤ 1). Each phase diagram is validated and optimized through only three new experiments. The complexity of these compounds is beyond the reach of today’s computational methods.

36 MATERIALS SCIENCE↗