Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample minimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Geant4 simulation for a study of a possible use of carbon ions pencil beam for the treatment of ocular melanomas with the active scanning system at CNAO Centre

The aim of this work is to validate the Geant4 application reproducing the CNAO (National Centre for Oncological Hadrontherapy) beamline and to study of a possible use of carbon ion pencil beams for the treatment of ocular melanomas at the CNAO Centre. The promising aspect of carbon ions radiotherapy for the treatment of this disease lies in its superior relative radiobiological effectiveness (RBE). The Monte Carlo Geant4 toolkit is used to simulate the complete CNAO extraction beamline, with the active and passive components along it. A human eye modeled detector, including a realistic target tumor volume, is used as target. Cross check with previous studies at CNAO using protons allows comparisons on possible benefits on using such a technique with respect to proton beams. Before the eye-detector irradiation a validation of the Geant4 simulation with CNAO experimental data is carried out with both carbon ions and protons. Important beam parameters such as the transverse FWHM and scanned radiation field 's uniformity are tested within the simulation and compared with experimental measurements at CNAO Centre. The physical processes involved in secondary particles generation by carbon ions and protons in the eye-detector are reproduced to take into account the additional dose to the primary beam given to irradiated eye's tissues. A study of beam shaping is carried out to produce a uniform 3D dose distribution (shaped on the tumor) by the use of a spread out Bragg peak. The eye-detector is then irradiated through a two dimensional transverse beam scan at different depths. In the use case the eye-detector is rotated of an angle of 40 deg. in the vertical direction, in order to mis-align the tumor from healthy tissues in front of it. The treatment uniformity on the tumor in the eye-detector is tested. For a more quantitative description of the deposited dose in the eye-detector and for the evaluation of the ratio between the dose deposited in the tumor and the other eye components, proton and carbon DVHs (Dose Volume Histograms) are compared. A high statistics simulated sample is used to minimize statistical errors. In the simulation a new particle generation method is developed in order to reproduce the experimental treatment plan by importing the DICOM RT-PLAN file, which contains all the information on the irradiation geometries and sequences (treatment plan parameters). Conclusions Even further validations must be done, the good results so far obtained by this work point out and confirm the possibility of using carbon ions delivered with active scanning beams to treat the ocular melanoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Weighted greedy-optimal design of computer experiments for kernel-based and Gaussian process model emulation and calibration

This article is concerned with the approximation of high-dimensional functions by kernel-based methods. Motivated by uncertainty quantification, which often necessitates the construction of approximations that are accurate with respect to a probability density function of random variables, we aim at minimizing the approximation error with respect to a weighted $L^p$-norm. We present a greedy procedure for designing computer experiments based upon a weighted modification of the pivoted Cholesky factorization. The method successively generates nested samples with the goal of minimizing error in regions of high probability. Numerical experiments validate that this new importance sampling strategy is superior to other sampling approaches, especially when used with non-product probability density functions. We also show how to use the proposed algorithm to efficiently generate surrogates for inferring unknown model parameters from data.

97 MATHEMATICS AND COMPUTING↗

Biofilm monitoring coupon system and method of use

An apparatus and method is disclosed for biofilm monitoring of a water distribution system which includes the mounting of at least one fitting in a wall port of a manifold in the water distribution system with a passage through the fitting in communication. The insertion of a biofilm sampling member is through the fitting with planar sampling surfaces of different surface treatment provided on linearly arrayed sample coupons of the sampling member disposed in the flow stream in edge-on parallel relation to the direction of the flow stream of the manifold under fluid-tight sealed conditions. The sampling member is adapted to be aseptically removed from or inserted in the fitting and manifold under a positive pressure condition and the fitting passage sealed immediately thereafter by appropriate closure means so as to preclude contamination of the water distribution system through the fitting. The apparatus includes means for clamping the sampling member and for establishing electrical continuity between the sampling surfaces and the system for minimizing electropotential effects. The apparatus may also include a plurality of fittings and sampling members mounted on the manifold to permit extraction of the sampling members in a timed sequence throughout the monitoring period.

Sauer, Richard L.↗

Thermal Design, Analysis, and Testing of the Quench Module Insert Bread Board

The science requirements for materials processing is to provide the desired PI requirements of thermal gradient, solid/liquid interface front velocity for a given processing temperature desired by the PI. Processing is performed by translating the furnace with the sample in a stationary position to minimize any disturbances to the solid/liquid interface front during steady state processing. Typical sample materials for this metals and alloys furnace are lead-tin alloys, lead-antimony alloys, and aluminum alloys. Samples must be safe to process and therefore typically are contained with hermetically sealed cartridge tubes (gas tight) with inner ceramic liners (liquid tight) to prevent contamination and/or reaction of the sample material with the cartridge tube.

Breeding Shawn↗

Uncertainties in model-independent extractions of amplitudes from complete experiments

A new generation of over-complete experiments is underway, with the goal of performing a high precision extraction of pseudoscalar meson photo-production amplitudes. Such experimentally determined amplitudes can be used both as a test to validate models and as a starting point for an analytic continuation in the complex plane to search for poles. Of crucial importance for both is the level of uncertainty in the extracted multipoles. We have probed these uncertainties by analyses of pseudo-data for KLambda photoproduction, first for the set of 8 observables that have been published for the K{sup +} Lambda channel and then for pseudo-data on a complete set of 16 observables with the uncertainties expected from analyses of ongoing CLAS experiments. In fitting multipoles, we have used a combined Monte Carlo sampling of the amplitude space, with gradient minimization, and have found a shallow X{sup 2} valley pitted with a large number of local minima. This results in bands of solutions that are experimentally indistinguishable. All ongoing experiments will measure observables with limited statistics. We have found a dependence on the particular random choice of values of Gaussian distributed pseudo-data, due to the presence of multiple local minima. This results in actual uncertainties for reconstructed multipoles that are often considerable larger than those returned by gradient minimization routines such as Minuit which find a single local minimum. As intuitively expected, this additional level of uncertainty decreases as larger numbers of observables are included.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Oxidation Penetration in Nuclear Graphite

Study results are presented for seven grades of graphite where 21 cylindrical samples were oxidized to a nominal level of mass loss. Low mass loss samples exhibited ~3% oxidative mass loss, intermediate ~8%, and high ~11%. Flat sample surfaces were covered during oxidation to minimize oxidation penetration at the top and bottom of each sample. Oxidized samples had their diameters reduced stepwise in 1 mm or 2 mm increments. Residual samples were weighed, geometric dimensions were recorded, and Archimedes measurements were taken at each step. Preliminary comparative graphical analysis is presented to illustrate the resultant density gradients observed. Raw tabular data are also provided.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ion beam production with sub-milligram samples of material from an ECR source for AMS

Current accelerator mass spectrometry experiments at the Argonne Tandem Linac Accelerator System facility at Argonne National Laboratory push us to improve the ion source performance with a large number of samples and a need to minimize cross contamination. These experiments can require the creation of ion beams from as little as a few micrograms of material. These low concentration samples push the limit of our current efficiency and stability capabilities of the electron cyclotron resonance ion source. A combination of laser ablation and sputtering techniques coupled with a newly modified multi-sample changer has been used to meet this demand. We will discuss performance, stability, and consumption rates as well as planned improvements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Post-irradiation examination of UN-Mo-W fuels for space nuclear propulsion

The National Aeronautics and Space Administration's return to space nuclear propulsion stems from the need for a more efficient method of space travel. Nuclear thermal propulsion systems have been shown to be two times more efficient than chemical propulsion. NASA's Sirius program was created to fabricate and test fuels for space nuclear propulsion, specifically to determine their performance under prototypical startup conditions. The Sirius project featured 4 test capsules, Sirius-1 featured uranium nitride fuel dispersed in a matrix of tungsten and rhenium, while Sirius-2A, -2B, and -3 featured uranium nitride-molybdenum-tungsten fuel (UN-Mo-W). This study discusses the Sirius-2A and -2B irradiation experiments at the Idaho National Laboratory, specifically their performance under irradiation at the Transient Reactor Test Facility. It was found that the fuel samples overall did not exhibit significant cracking, though the Sirius-2A fuel did have one large crack on the surface of the fuel. There was minimal hydrogen absorption in the samples, though it is unknown if the absorption occurred during irradiation or during fabrication. Mechanical testing indicated that the UN fuel demonstrated ceramic behavior as expected, and the Mo/W matrix demonstrated linear elastic behavior to failure.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Remote water-monitoring system

General-purpose, water-quality sampling process detects microorganisms and integrates sampling, sample preservation, and sample analysis. System overcomes difficulties in correlation of surface measurements with remote measurements and minimizes human error in handling of samples and instrumentation.

Grana, D. C.↗

Estimating optimal sampling unit sizes for satellite surveys

This paper reports on an approach for minimizing data loads associated with satellite-acquired data, while improving the efficiency of global crop area estimates using remotely sensed, satellite-based data. Results of a sampling unit size investigation are given that include closed-form models for both nonsampling and sampling error variances. These models provide estimates of the sampling unit sizes that effect minimal costs. Earlier findings from foundational sampling unit size studies conducted by Mahalanobis, Jessen, Cochran, and others are utilized in modeling the sampling error variance as a function of sampling unit size. A conservative nonsampling error variance model is proposed that is realistic in the remote sensing environment where one is faced with numerous unknown nonsampling errors. This approach permits the sampling unit size selection in the global crop inventorying environment to be put on a more quantitative basis while conservatively guarding against expected component error variances.

Hallum, C. R.↗

Near-isothermal furnace for in situ and real time X-ray radiography solidification experiments

In this paper, we present a newly developed near-isothermal X-ray transparent furnace for in situ imaging of solidification processes in thin metallic samples. We show that the furnace is ideally suited to study equiaxed microstructure evolution and grain interaction. To observe the growth dynamics of equiaxed dendritic structures, a minimal temperature gradient across the sample is required. A uniform thermal profile inside a circular sample is achieved by positioning the sample in the center of a cylindrical furnace body surrounded by a circular heater arrangement. Performance tests with the hypo-eutectic Al-15wt.%Cu and the near-eutectic Al-33wt.%Cu alloys validate the near-isothermal character of the sample environment. Controlled cooling rates of less than 0.5 K min{sup −1} up to 10 K min{sup −1} can be achieved in a temperature range of 720 K–1220 K. Integrated in our rotatable laboratory X-ray facility, X-RISE, the furnace provides a large field of view of 10.5 mm in diameter and a high spatial resolution of ∼4 μm. With the here presented furnace, equiaxed dendrite growth models can be rigorously tested against experiments on metal alloys by, e.g., enabling dendrite growth velocities to be determined as a function of undercooling or solutal fields in front of the growing dendrite to be measured.

36 MATERIALS SCIENCE↗

Optical Properties of Nanosatellite Hardware

Over the last decade, a number of very small satellites have been launched into space. These have been called nanosatellites (generally of a weight between 1 and 10 kg) or picosatellites (weight <1 kg). This also includes CubeSats, which are based on 10-cm cube units. With the addition of the Japanese Experiment Module (JEM) Small Satellite Orbital Deployer (J-SSOD) to the International Space Station (ISS), CubeSats are easily cycled through the JEM airlock and deployed into space (fig. 1). The number of CubeSats launched since 2003 was approaching 100 at the time of publication, and the authors expect this trend in research to continue, particularly for high school and college flight experiments. Because these spacecraft are so small, there is usually no allowance for shielding or active heating or cooling of the avionics and other hardware. Parts that are usually ignored in the thermal analysis of larger spacecraft may contribute significantly to the heat load of a tiny satellite. In addition, many small satellites have commercial-off-the-shelf (COTS) components. To reduce costs, many providers of COTS components do not include the optical and physical parameters necessary for accurate thermal analysis. Marshall Space Flight Center participated in the development and analysis of the Space Missile Defense Command-Operational Nanosatellite Effect (SMDC-ONE) and the Edison Demonstration of Smallsat Networks (EDSN) nanosatellites. These optical property measurements are documented here in hopes that they may benefit future nanosatellite and picosatellite programs and aid thermal analysis to ensure project goals are met, with the understanding that material properties may vary by vendor, batch, manufacturing process, and preflight handling. Where possible, complementary data are provided from ground simulations of the space environment and flight experiments, such as the Materials on International Space Station Experiment (MISSE) series. NASA gives no recommendation, endorsement, or preference, either expressed or implied, concerning materials and vendors used. Solar absorptance was calculated from spectral reflectance measurements made from 250 to 2,800 nm with an AZ Technology Laboratory Portable Spectroreflectometer (LPSR) model 300. ASTM E-903 was the test method used under normal laboratory conditions, and ASTM E-490 was the solar spectral irradiance data used to calculate solar absorptance. Most of the samples were flat, but stray light was minimized as much as possible with either a blackbody or black cloth as sample background. The LPSR has repeatability of approximately +/-1%, where solar absorptance is given as range, that is, from actual measurements taken across the sample. Infrared emittance measurements were made with an AZ Technology TEMP 2000A infrared reflectometer. This instrument measures the total hemispheric reflectance averaged over 3-35 micrometer wavelengths. ASTM E-408 was the test method used under normal laboratory conditions. 3 Stray light was minimized as much as possible. The TEMP 2000A has repeatability of approximately +/-0.5%, where infrared emittance is given as a range, that is, from actual measurements taken across the sample.

Finckenor, M. M.↗

The crystal structure of a biogenic aragonite from the nacre of an ammonite shell

The crystal structure of a biogenic aragonite from the nacre of an ammonite shell was obtained using synchrotron high-resolution powder X-ray diffraction (HRPXRD) data and Rietveld structure refinement. The well-preserved ammonite sample is from Alberta, Canada, and is from the Cretaceous period. The aragonite structure was refined in space group Pmcn, Z = 4, and the cell parameters obtained are a = 4.96265(2), b = 7.97016(4), c = 5.74474(3) {angstrom}, and V = 227.222(2) {angstrom}{sup 3}. The chemical analyses indicate a formula of [Ca{sub 0.995}Sr{sub 0.004}Ba{sub 0.001}]{Sigma} = 1.0(CO{sub 3}). The average <Ca-O> and <C-O> distances are 2.5281(3) and 1.2871(6) {angstrom}, respectively, and the average <O-C-O> angle is 119.94(8){sup o}. The CO{sub 3} groups are non-planar. Based on crystal-structure data for biogenic and non-biogenic aragonite samples, aragonite from ammonite nacre has minimal structural distortions and is very similar to non-biogenic aragonite, in particular, a sample from Spain.

58 GEOSCIENCES↗

Microgravity ignition experiment

The purpose of this project is to develop a flight ready apparatus of the microgravity ignition experiment for the GASCan 2 program. This involved redesigning, testing, and making final modifications to the existing apparatus. The microgravity ignition experiment is intended to test the effect of microgravity on the time to ignition of a sample of alpha-cellulose paper. An infrared heat lamp is used to heat the paper sample within a sealed canister. The interior of the canister was redesigned to increase stability and minimize conductive heat transfer to the sample. This design was fabricated and tested and a heat transfer model of the paper sample was developed.

Motevalli, Vahid↗

Application of higher harmonic blade feathering for helicopter vibration reduction

Higher harmonic blade feathering for helicopter vibration reduction is considered. Recent wind tunnel tests confirmed the effectiveness of higher harmonic control in reducing articulated rotor vibratory hub loads. Several predictive analyses developed in support of the NASA program were shown to be capable of calculating single harmonic control inputs required to minimize a single 4P hub response. In addition, a multiple-input, multiple-output harmonic control predictive analysis was developed. All techniques developed thus far obtain a solution by extracting empirical transfer functions from sampled data. Algorithm data sampling and processing requirements are minimal to encourage adaptive control system application of such techniques in a flight environment.

Powers, R. W.↗

Effect of conductivity and concentration on the sample stream in the transverse axis of a continuous flow electrophoresis chamber

The resolution of continuous flow electrophoresis systems is generally measured by the spread of the sample bands in the direction of the electrophoretic migration. This paper evaluates the cross section of the sample bands in the plane perpendicular to the flow and shows that the spread in the direction perpendicular to the migration increased significantly with the applied electric field. Concentrated samples of monodisperse latex particles and vinyltoluene T-butylstyrene particles in sample buffers of different electrical conductivities were used to map the shape of the sample bands relative to the zero electric field case. As the electric field was applied, the sample band spread from an initial diameter of only one-third the chamber thickness until it approached the chamber walls where electroosmosis significantly reduced the resolution of separation. It can be shown, however, that it is possible to minimize these distortions by careful sample preparation and experiment design.

Miller, Teresa Y.↗

BY-110 Headspace Sampling Comparison Test: Volume 1

The Hanford Tank Operations Contractor, Washington River Protection Solutions, conducted comparison tests of two Hanford Waste tank vapor sampling systems to determine the relative differences in quantifying Chemicals of Potential Concern (COPC) while sampling the same waste tank. The systems are the traditional in situ, inline headspace sampling (HS) method and the recently developed slipstream sampling unit for testing respirator chemical cartridges known as the cartridge test (CT) rig. The comparison test was performed to determine if results obtained using the CT rig are similar to results obtained using the traditional HS method. Using the CT rig would provide efficiencies in headspace vapors sampling such as applying ALARA principles, minimizing worker entries to the tank farms, and eliminating the physical strain of manually lowering the headspace sampling bundles into the waste tanks. Six sampling events were conducted during January and February 2018 to collect headspace vapor samples from Hanford tank BY-110 with the two systems. Pacific Northwest National Laboratory was tasked with conducting an analysis of the analytical results to assess the comparability of the sampling methods and make recommendations on future testing or deployment of the CT method.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

BY-110 Headspace Sampling Comparison Test: Volume 2: Raw Data

The Hanford Tank Operations Contractor, Washington River Protection Solutions, conducted comparison tests of two Hanford Waste tank vapor sampling systems to determine the relative differences in quantifying Chemicals of Potential Concern (COPC) while sampling the same waste tank. The systems are the traditional in situ, inline headspace sampling (HS) method and the recently developed slipstream sampling unit for testing respirator chemical cartridges known as the cartridge test (CT) rig. The comparison test was performed to determine if results obtained using the CT rig are similar to results obtained using the traditional HS method. Using the CT rig would provide efficiencies in headspace vapors sampling such as applying ALARA principles, minimizing worker entries to the tank farms, and eliminating the physical strain of manually lowering the headspace sampling bundles into the waste tanks. Six sampling events were conducted during January and February 2018 to collect headspace vapor samples from Hanford tank BY-110 with the two systems. Pacific Northwest National Laboratory was tasked with conducting an analysis of the analytical results to assess the comparability of the sampling methods and make recommendations on future testing or deployment of the CT method.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗