Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Beyond Nanopore Sequencing in Space: Identifying the Unknown

Astronaut Kate Rubins sequenced DNA on the International Space Station (ISS) for the first time in August 2016 (Figure 1A). A 2D sequencing library containing an equal mixture of lambda bacteriophage, Escherichia coli, and Mus musculus was prepared on the ground with a SQK_MAP006 kit and sent to the ISS frozen and loaded into R7.3 flow cells. After a total of 9 on-orbit sequencing runs over 6 months, it was determined that there was no decrease in sequencing performance on-orbit compared to ground controls (1). A total of ~280,000 and ~130,000 reads generated on-orbit and on the ground, respectively, identified 90% of reads that were attributed to 30% lambda bacteriophage, 30% Escherichia coli, and 30% M. musculus (Figure 1B). Extensive bioinformatics analysis determined comparable 2D and 1D read accuracies between flight and ground runs (Figure 1C), and data collected from the ISS were able to construct directed assemblies of E.coli and lambda genomes at 100% and M. musculus mitochondrial genome at 96.7%. These findings validate sequencing as a viable option for potential on-orbit applications such as environmental microbial monitoring and disease diagnosis. Current microbial monitoring of the ISS applies culture-based techniques that provide colony forming unit (CFU) data for air, water, and surface samples. The identity of the cultured microorganisms in unknown until sample return and ground-based analysis, a process that can take up to 60 days. For sequencing to benefit ISS applications, spaceflight-compatible sample preparation techniques are required. Subsequent to the testing of the MinION on-orbit, a sample-to-sequence method was developed using miniPCR™ and basic pipetting, which was only recently proven to be effective in microgravity. The work presented here details the in- flight sample preparation process and the first application of DNA sequencing on the ISS to identify unknown ISS-derived microorganisms.

Stahl, Sarah E.↗

Uncertainty Estimates for Fitting Zernike Polynomials to Discrete Data

Zernike polynomials are a widely used metric in modern optical analysis. They conveniently represent surfaces as a series of weighted terms corresponding to various optical aberrations. Ideally, each term is independent of others in the series, but Zernike polynomials lose this property when working with sets of discrete data. This gives rise to uncertainty in each polynomial’s actual contribution and affects metrology and simulation estimates of their relative weights. Several factors influencing these estimates are the number and arrangement of sample locations, the method for calculating the weights, and the total number of Zernike terms used in the calculation. Discussed is the uncertainty associated with linear regression using random sampling. Other topics reviewed are complex Zernike polynomials and vector spaces of functions.

Zernike Polynomials↗

Analysis of Mars Analogue Soil Samples Using Solid-Phase Microextraction, Organic Solvent Extraction and Gas Chromatography/Mass Spectrometry

Polycyclic aromatic hydrocarbons (PAHs) are robust and abundant molecules in extraterrestrial environments. They are found ubiquitously in the interstellar medium and have been identified in extracts of meteorites collected on Earth. PAHs are important target molecules for planetary exploration missions that investigate the organic inventory of planets, moons and small bodies. This study is part of an interdisciplinary preparation phase to search for organic molecules and life on Mars. We have investigated PAH compounds in desert soils to determine their composition, distribution and stability. Soil samples (Mars analogue soils) were collected at desert areas of Utah in the vicinity of the Mars Desert Research Station (MDRS), in the Arequipa region in Peru and from the Jutland region of Denmark. The aim of this study was to optimize the solid-phase microextraction (SPME) method for fast screening and determination of PAHs in soil samples. This method minimizes sample handling and preserves the chemical integrity of the sample. Complementary liquid extraction was used to obtain information on five- and six-ring PAH compounds. The measured concentrations of PAHs are, in general, very low, ranging from 1 to 60 ng g(sup -1). The texture of soils is mostly sandy loam with few samples being 100% silt. Collected soils are moderately basic with pH values of 8-9 except for the Salten Skov soil, which is slightly acidic. Although the diverse and variable microbial populations of the samples at the sample sites might have affected the levels and variety of PAHs detected, SPME appears to be a rapid, viable field sampling technique with implications for use on planetary missions.

Orzechowska, G. E.↗

Annular denuder systems: Precision and applicability to stratospheric sampling

Annular denuder systems (ADS) are designed to sample both gases and particles from ambient air without cross interference. The ADS's were used to detect chemical gradients over rural forest canopies. Accurate and precise methods for the sampling and analysis of low concentrations of gaseous and particulate species over short sampling periods were developed. Typical analytical precision data for nitrate and sulfate are shown. Both sampling and analytical precision data for a 2 hour test using four collocated ADS's are presented. On this particular day, the overall precision for HNO3 was unusually poor. The overall precision for the major constituents of interest is generally about 3 to 5 percent for typical ambient concentrations. The ADS's could potentially be used to determine the concentrations of HNO3 and fine-particle nitrate in the stratosphere, and to simultaneously characterize the chemical composition of stratospheric aerosols. Assuming 50 mb pressure, a 2 hour sampling time, a 50 Lpm sampling rate, and a low blank value, an overal precision of about 15 percent should be possible for 1 ppbv of HNO3 or nitrate, which would include nitric-acid trihydrate (NAT); and pump-driven systems could accommodate more complex systems involving denuders and filter packs in sequence. Alternate coatings could possibly be developed to selectively sample species such as Cl2 and ClNO3. The ADS's might also be useful in laboratory studies of heterogeneous chemical reactions involving NAT aerosols.

Randtke, Stephen J.↗

Remote Recession Measurements of Wire-Seeded PICA Samples in an Arc-Jet Flow

Various methods for remote recession sensing of PICA have been developed and several seeding methods have been tested. The most recent method involved seeding the ablator with wires fed to the sample from the backside with a defined amount of PICA left towards the upstream front of the sample. This seed method mimics the installation of in-depth thermocouples as they are frequently used in ground testing and flight. Arc-jet tests were conducted in the NASA Langley HYMETS facility at a heat flux of 320 W/sq.cm. The emission of the post-shock layer was observed in spectral resolution from the side along an optical axis perpendicular to the arc-jet flow and from the front, looking at the sample surface from an upstream position. Various metallic seed materials with different melting points were used. In addition to the emission spectroscopy measurements, the samples were monitored during the tests through pyrometry and videography. The time resolved response of the seeded material is described and compared to earlier tests with different seeding methods. The combination of seed materials was found to be critical for the selection of emission signatures characteristic for the material recession which can be isolated in the final emission spectra.

Winter, Michael↗

Numerical operator method

Algebraic solutions of difference equations - stability of sampled-data control systems - numerical method for determining transients in electric systems excited by complex signals

ELECTRIC NETWORK↗

A methodology for small scale rural land use mapping in semi-arid developing countries using orbital imagery. Part 5: Experimental and operational techniques of mapping land use

The author has identified the following significant results. Scope of the preprocessing techniques was restricted to standard material from the EROS Data Center accompanied by some enlarging procedures and the use of the diazo process. Investigation has shown that the most appropriate sampling strategy for this study is the stratified random technique. A viable sampling procedure, together with a method for determining minimum number of sample points in order to test results of any interpretation are presented.

Vangenderen, J. L.↗

Viral coefficient and hidden mass in the galaxy groups

The purpose is the verification of the virial mass estimations for small galaxy groups. The dynamical evolution of triple and quintuple galaxies was studied by the numerical simulations. The dependence of the virial coefficient k(t) versus time was derived. Initial k(O) = O. The function k(t) has some strong oscillations from 0.02 to 0.99. Generally, these oscillations are quasiperiodical ones. Such a behavior of k(t) is caused by formation in a system of close isolated temporary double subsystems. A strong correlation between the virial coefficient and the least mutual distance in the system is observed. Such wide oscillations may add into the estimation of virial mass of the galaxy groups an uncertainty of more than one order. An additional uncertainty is introduced by the projection effect. This uncertainty for the individual estimations of the masses approach three orders. Thus any individual estimation of the virial mass is impossible for small galaxy groups. Some possibility of statistical estimation (median or average) of the total mass, including a hidden mass, is shown for the homogeneous samples. The authors propose a method for these estimations based on a comparison of the medians of dynamical parameters (a mean size in projection and a dispersion of relative radial velocities) for the simulated and observed ensembles of the galaxy groups. This method has been applied to a sample of 46 probably physical triplets of galaxies. The probable median of the hidden mass in a volume of the triplet is about 4 M, where M is the total mass of visible matter.

Anosova, Joanna P.↗

Thermal conduction in a composite circular cylinder: A new technique for thermal conductivity measurements of lunar core samples

The core sample is heated from the outside at a known rate and the rise in temperature at the surface of the core tube is measured. Because the temperature at the surface, increasing with time, is a function of the thermal properties of both the core tube and the sample, the thermal properties of the sample can be estimated by comparing the measured temperature with the theory, provided that the thermal properties of the core tube are known. Thus it is not necessary to extract the sample from the core tube to make the measurements. Neither is it necessary to insert a heater, or temperature sensor, into the sample within the core tube, as would be required if another method were applied. The sample remains intact after the measurements. The temperature change in the sample can be kept to a minimum as long as the thermal conductivity determination is possible with a reasonable precision. If the radiative method of heat transfer is chosen, the core tube will only be in mechanical contact with the sample holder and a sensor attached to the core tube to measure the surface temperature, thereby greatly reducing the possibility of disturbing the sample.

Horai, K.↗

Quantitating Iron in Serum Ferritin by Use of ICP-MS

A laboratory method has been devised to enable measurement of the concentration of iron bound in ferritin from small samples of blood (serum). Derived partly from a prior method that depends on large samples of blood, this method involves the use of an inductively-coupled-plasma mass spectrometer (ICP-MS). Ferritin is a complex of iron with the protein apoferritin. Heretofore, measurements of the concentration of serum ferritin (as distinguished from direct measurements of the concentration of iron in serum ferritin) have been used to assess iron stores in humans. Low levels of serum ferritin could indicate the first stage of iron depletion. High levels of serum ferritin could indicate high levels of iron (for example, in connection with hereditary hemochromatosis an iron-overload illness that is characterized by progressive organ damage and can be fatal). However, the picture is complicated: A high level of serum ferritin could also indicate stress and/or inflammation instead of (or in addition to) iron overload, and low serum iron concentration could indicate inflammation rather than iron deficiency. Only when concentrations of both serum iron and serum ferritin increase and decrease together can the patient s iron status be assessed accurately. Hence, in enabling accurate measurement of the iron content of serum ferritin, the present method can improve the diagnosis of the patient s iron status. The prior method of measuring the concentration of iron involves the use of an atomic-absorption spectrophotometer with a graphite furnace. The present method incorporates a modified version of the sample- preparation process of the prior method. First, ferritin is isolated; more specifically, it is immobilized by immunoprecipitation with rabbit antihuman polyclonal antibody bound to agarose beads. The ferritin is then separated from other iron-containing proteins and free iron by a series of centrifugation and wash steps. Next, the ferritin is digested with nitric acid to extract its iron content. Finally, a micronebulizer is used to inject the sample of the product of the digestion into the ICPMS for analysis of its iron content. The sensitivity of the ICP-MS is high enough to enable it to characterize samples smaller than those required in the prior method (samples can be 0.15 to 0.60 mL).

Smith, Scott M.↗

Methods for presentation and display of multivariate data

Methods for the presentation and display of multivariate data are discussed with emphasis placed on the multivariate analysis of variance problems and the Hotelling T(2) solution in the two-sample case. The methods utilize the concepts of stepwise discrimination analysis and the computation of partial correlation coefficients.

Myers, R. H.↗

Planning and Execution for Front Delineation and Tracking with Multiple Underwater Vehicles

This work describes a planning architecture for a heterogeneous fleet of marine assets as well as a method for detecting and tracking ocean fronts using multiple autonomous underwater vehicles. Multiple vehicles — equally-spaced along the expected frontal boundary — complete near parallel transects orthogonal to the front. Lateral gradients are used to determine the location of the front crossing from each individual vehicle transect by detecting a change in the observed water property. Adaptive control of the vehicles ensure they remain perpendicular to the estimated frontal boundary as it evolves over time. This method was demonstrated in several experiment periods totaling weeks, in and around Monterey Bay, California in May and June of 2017. We discuss the challenges associated with the implementation of the planning system. We show the capability of this method for repeated sampling across a dynamic two-dimensional ocean front using a fleet of three types of platforms: short-range Iver AUVs, Tethys-Class Long-Range AUVs, and Seagliders. This method extends to tracking gradients of different properties using a variety of vehicles.

Chavez, Francisco P.↗

Extraction of amino acids from soils and sediments with superheated water

A method of extraction for amino acids from soils and sediments involving superheated water has been investigated. About 75-97 per cent of the amino acids contained in four soils of a soil profile from Illinois were extracted by this method. Deep penetration of water into soil aggregates and partial hydrolysis of peptide bonds during this extraction by water at high temperature are likely mechanisms responsible for the release of amino acids from samples. This extraction method does not require subsequent desalting treatments when analyses are carried out with an ion-exchange amino acid analyzer.

Cheng, C. N.↗

Trace element geochemistry and the early lunar differentiation

The results are considered of experiments in which thermal neutron activation analysis was used to measure the halogens, U, Te, Ru, Os, and Hg in lunar samples. A calorimetric method was used for P2O5. Three Apollo 17 basalts, one Apollo 11 basalt, and one Apollo 15 basalt were used for the Ru-Os study. Os and Ru were measured in seven samples of breccia 14305 in a series of experiments to check an apparent anomaly in the isotopic composition of the Hg which it contains. A lunar model for Ru-Os partition is discussed. It is suggested that Ru and Os were partitioned and fractionated in the original differentiation of the lunar surface ocean. Fractionation among near-surface materials was less than a factor of 2 according to the lithic breccia data. Fractionations among basaltic sources were very large, exceeding 100, and primarily due to Ru. A clue to Ru and Os distributions at the depths from which mare basalts were derived may be provided by the relative ages of the basalts. These are interpreted as being related to partial melting in response to temperature increases at depth with time.

Jovanovic, S.↗

Comparison of Focused and Near-Field Imaging of Spray on Foam Insulation (SOFI) at Millimeter Wave Frequencies

The Space Shuttle Columbia's catastrophic accident was due to a piece of Spray on Foam Insulation (SOFI) that broke off from the external tank and damaged the leading edge of the orbiter's left wing. Millimeter wave focused and near-field imaging methods have been suessfully used for inspecting of the SOFI samples. Comparison between these methods for the purpose of detection and evaluation of flaws in the SOFI is provided using examples of images of SOFI samples.

Kharkovsky, S.↗

Guidebook for Limited Sample Probability of Detection (LS-POD) Demonstration for Signal-Response Nondestructive Evaluation (NDE) Methods

This document provides guidance for performing limited sample probability of detection (LS-POD) demonstration testing with smaller numbers of flawed specimens than the 29 required for the Point Estimate POD method referenced in NASA Standard 5009B. This document is specifically applicable to NASA programs and projects where NASA Special NDE methods are used to inspect fracture critical human spaceflight metallic hardware when the minimum number of flawed specimens required for the Point Estimate POD method referenced in NASA Standard 5009B (2019) are not available.

Limited Sample Probability of Detection↗

Mapping Pixel Windows To Vectors For Parallel Processing

Mapping performed by matrices of transistor switches. Arrays of transistor switches devised for use in forming simultaneous connections from square subarray (window) of n x n pixels within electronic imaging device containing np x np array of pixels to linear array of n(sup2) input terminals of electronic neural network or other parallel-processing circuit. Method helps to realize potential for rapidity in parallel processing for such applications as enhancement of images and recognition of patterns. In providing simultaneous connections, overcomes timing bottleneck or older multiplexing, serial-switching, and sample-and-hold methods.

Duong, Tuan A.↗