Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensitivity methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Rapid characterization of microscopic two-level systems using Landau-Zener transitions in a superconducting qubit

We demonstrate a fast method to detect microscopic two-level systems in a superconducting phase qubit. By monitoring the population leak after sweeping the qubit bias flux, we are able to measure the two-level systems that are coupled with the qubit. Compared with the traditional method that detects two-level systems by energy spectroscopy, our method is faster and more sensitive. This method supplies a useful tool to investigate two-level systems in solid-state qubits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reliability enhancement of Navier-Stokes codes through convergence enhancement

Reduction of total computing time required by an iterative algorithm for solving Navier-Stokes equations is an important aspect of making the existing and future analysis codes more cost effective. Several attempts have been made to accelerate the convergence of an explicit Runge-Kutta time-stepping algorithm. These acceleration methods are based on local time stepping, implicit residual smoothing, enthalpy damping, and multigrid techniques. Also, an extrapolation procedure based on the power method and the Minimal Residual Method (MRM) were applied to the Jameson's multigrid algorithm. The MRM uses same values of optimal weights for the corrections to every equation in a system and has not been shown to accelerate the scheme without multigriding. Our Distributed Minimal Residual (DMR) method based on our General Nonlinear Minimal Residual (GNLMR) method allows each component of the solution vector in a system of equations to have its own convergence speed. The DMR method was found capable of reducing the computation time by 10-75 percent depending on the test case and grid used. Recently, we have developed and tested a new method termed Sensitivity Based DMR or SBMR method that is easier to implement in different codes and is even more robust and computationally efficient than our DMR method.

Choi, K.-Y.↗

Preliminary Design of Low-Thrust Interplanetary Missions

For interplanetary missions, highly efficient electric propulsion systems can be used to increase the mass delivered to the destination and/or reduce the trip time over typical chemical propulsion systems. This technology is being demonstrated on the Deep Space 1 mission - part of NASA's New Millennium Program validating technologies which can lower the cost and risk and enhance the performance of future missions. With the successful demonstration on Deep Space 1, future missions can consider electric propulsion as a viable propulsion option. Electric propulsion systems, while highly efficient, produce only a small amount of thrust. As a result, the engines operate during a significant fraction of the trajectory. This characteristic makes it much more difficult to find optimal trajectories. The methods for optimizing low-thrust trajectories are typically categorized as either indirect, or direct. Indirect methods are based on calculus of variations, resulting in a two-point boundary value problem that is solved by satisfying terminal constraints and targeting conditions. These methods are subject to extreme sensitivity to the initial guess of the variables - some of which are not physically intuitive. Adding a gravity assist to the trajectory compounds the sensitivity. Direct methods parameterize the problem and use nonlinear programming techniques to optimize an objective function by adjusting a set of variables. A variety of methods of this type have been examined with varying results. These methods are subject to the limitations of the nonlinear programming techniques. In this paper we present a direct method intended to be used primarily for preliminary design of low-thrust interplanetary trajectories, including those with multiple gravity assists. Preliminary design implies a willingness to accept limited accuracy to achieve an efficient algorithm that executes quickly.

Sims, Jon A.↗

Sensitivity and Calibration of Non-Destructive Evaluation Method That Uses Neural-Net Processing of Characteristic Fringe Patterns

This paper answers some performance and calibration questions about a non-destructive-evaluation (NDE) procedure that uses artificial neural networks to detect structural damage or other changes from sub-sampled characteristic patterns. The method shows increasing sensitivity as the number of sub-samples increases from 108 to 6912. The sensitivity of this robust NDE method is not affected by noisy excitations of the first vibration mode. A calibration procedure is proposed and demonstrated where the output of a trained net can be correlated with the outputs of the point sensors used for vibration testing. The calibration procedure is based on controlled changes of fastener torques. A heterodyne interferometer is used as a displacement sensor for a demonstration of the challenges to be handled in using standard point sensors for calibration.

Decker, Arthur J.↗

Design sensitivity analysis of rotorcraft airframe structures for vibration reduction

Optimization of rotorcraft structures for vibration reduction was studied. The objective of this study is to develop practical computational procedures for structural optimization of airframes subject to steady-state vibration response constraints. One of the key elements of any such computational procedure is design sensitivity analysis. A method for design sensitivity analysis of airframes under vibration response constraints is presented. The mathematical formulation of the method and its implementation as a new solution sequence in MSC/NASTRAN are described. The results of the application of the method to a simple finite element stick model of the AH-1G helicopter airframe are presented and discussed. Selection of design variables that are most likely to bring about changes in the response at specified locations in the airframe is based on consideration of forced response strain energy. Sensitivity coefficients are determined for the selected design variable set. Constraints on the natural frequencies are also included in addition to the constraints on the steady-state response. Sensitivity coefficients for these constraints are determined. Results of the analysis and insights gained in applying the method to the airframe model are discussed. The general nature of future work to be conducted is described.

Murthy, T. Sreekanta↗

Method for Determining the Sensitivity of a Physical Security System.

Modern systems, such as physical security systems, are often designed to involve complex interactions of technological and human elements. Evaluation of the performance of these systems often overlooks the human element. A method is proposed here to expand the concept of sensitivity—as denoted by d’—from signal detection theory (Green & Swets 1966; Macmillan & Creelman 2005), which came out of the field of psychophysics, to cover not only human threat detection but also other human functions plus the performance of technical systems in a physical security system, thereby including humans in the overall evaluation of system performance. New in this method is the idea that probabilities of hits (accurate identification of threats) and false alarms (saying “threat” when there is not one), which are used to calculate d’ of the system, can be applied to technologies and, furthermore, to different functions in the system beyond simple yes-no threat detection. At the most succinct level, the method returns a single number that represents the effectiveness of a physical security system; specifically, the balance between the handling of actual threats and the distraction of false alarms. The method can be automated, and the constituent parts revealed, such that given an interaction graph that indicates the functional associations of system elements and the individual probabilities of hits and false alarms for those elements, it will return the d’ of the entire system as well as d’ values for individual parts. The method can also return a measure of the response bias* of the system. One finding of this work is that the d’ for a physical security system can be relatively poor in spite of having excellent d’s for each of its individual functional elements.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A fast and sensitive size-exclusion chromatography method for plasma extracellular vesicle proteomic analysis

Extracellular vesicles (EVs) carry diverse biomolecules derived from their parental cells, making their components excellent biomarker candidates. However, purifying EVs is a major hurdle in biomarker discovery since current methods require large amounts of samples, are time-consuming and typically have poor reproducibility. Here we describe a simple, fast, and sensitive EV fractionation method using size exclusion chromatography (SEC) on a fast protein liquid chromatography (FPLC) system. Our method uses a Superose 6 Increase 5/150, which has a bed volume of 2.9 mL. The FPLC system and small column size enable reproducible separation of only 50 µL of human plasma in 15 min. To demonstrate the utility of our method, we used longitudinal samples from a group of individuals who underwent intense exercise. A total of 838 proteins were identified, of which, 261 were previously characterized as EV proteins, including classical markers, such as cluster of differentiation (CD)9 and CD81. Quantitative analysis showed low technical variability with correlation coefficients greater than 0.9 between replicates. The analysis captured differences in relevant EV proteins involved in response to physical activity. Our method enables fast and sensitive fractionation of plasma EVs with low variability, which will facilitate biomarker studies in large clinical cohorts.

59 BASIC BIOLOGICAL SCIENCES↗

Accelerated Sensitivity Analysis in High-Dimensional Stochastic Reaction Networks

Existing sensitivity analysis approaches are not able to handle efficiently stochastic reaction networks with a large number of parameters and species, which are typical in the modeling and simulation of complex biochemical phenomena. In this paper, a two-step strategy for parametric sensitivity analysis for such systems is proposed, exploiting advantages and synergies between two recently proposed sensitivity analysis methodologies for stochastic dynamics. The first method performs sensitivity analysis of the stochastic dynamics by means of the Fisher Information Matrix on the underlying distribution of the trajectories; the second method is a reduced-variance, finite-difference, gradient-type sensitivity approach relying on stochastic coupling techniques for variance reduction. Here in this paper we demonstrate that these two methods can be combined and deployed together by means of a new sensitivity bound which incorporates the variance of the quantity of interest as well as the Fisher Information Matrix estimated from the first method. The first step of the proposed strategy labels sensitivities using the bound and screens out the insensitive parameters in a controlled manner. In the second step of the proposed strategy, a finite-difference method is applied only for the sensitivity estimation of the (potentially) sensitive parameters that have not been screened out in the first step. Results on an epidermal growth factor network with fifty parameters and on a protein homeostasis with eighty parameters demonstrate that the proposed strategy is able to quickly discover and discard the insensitive parameters and in the remaining potentially sensitive parameters it accurately estimates the sensitivities. The new sensitivity strategy can be several times faster than current state-of-the-art approaches that test all parameters, especially in “sloppy” systems. In particular, the computational acceleration is quantified by the ratio between the total number of parameters over the number of the sensitive parameters.

97 MATHEMATICS AND COMPUTING↗

Multiscale design of nonlinear materials using a Eulerian shape optimization scheme

Motivated by recent advances in manufacturing, the design of materials is the focal point of interest in the material research community. One of the critical challenges in this field is finding optimal material microstructure for a desired macroscopic response. This work presents a computational method for the mesoscale-level design of particulate composites for an optimal macroscale-level response. The method relies on a custom shape optimization scheme to find the extrema of a nonlinear cost function subject to a set of constraints. Three key “modules” constitute the method: multiscale modeling, sensitivity analysis, and optimization. Multiscale modeling relies on a classical homogenization method and a nonlinear NURBS-based generalized finite element scheme to efficiently and accurately compute the structural response of particulate composites using a nonconformal discretization. A three-parameter isotropic damage law is used to model microstructure-level failure. An analytical sensitivity method is developed to compute the derivatives of the cost/constraint functions with respect to the design variables that control the microstructure's geometry. The derivation uncovers subtle but essential new terms contributing to the sensitivity of finite element shape functions and their spatial derivatives. Several structural problems are solved to demonstrate the applicability, performance, and accuracy of the method for the design of particulate composites with a desired macroscopic nonlinear stress-strain response.

42 ENGINEERING↗

Shear-Sensitive Liquid Crystal Coating Method Applied Through Transparent Test Surfaces

Research conducted at NASA Ames Research Center has shown that the color-change response of a shear-sensitive liquid crystal coating (SSLCC) to aerodynamic shear depends on both the magnitude of the local shear vector and its direction relative to the observer's in-plane line of sight. In conventional applications, the surface of the SSLCC exposed to aerodynamic shear is illuminated with white light from the normal direction and observed from an oblique above-plane view angle of order 30 deg. In this top-light/top-view mode, shear vectors with components directed away from the observer cause the SSLCC to exhibit color-change responses. At any surface point, the maximum color change (measured from the no-shear red or orange color) always occurs when the local vector is aligned with, and directed away from, the observer. The magnitude of the color change at this vector-observer-aligned orientation scales directly with shear stress magnitude. Conversely, any surface point exposed to a shear vector with a component directed toward the observer exhibits a non-color-change response, always characterized by a rusty-red or brown color, independent of both shear magnitude and direction. These unique, highly directional color-change responses of SSLCCs to aerodynamic shear allow for the full-surface visualization and measurement of continuous shear stress vector distributions. The objective of the present research was to investigate application of the SSLCC method through a transparent test surface. In this new back-light/back-view mode, the exposed surface of the SSLCC would be subjected to aerodynamic shear stress while the contact surface between the SSLCC and the solid, transparent wall would be illuminated and viewed in the same geometrical arrangement as applied in conventional applications. It was unknown at the outset whether or not color-change responses would be observable from the contact surface of the SSLCC, and, if seen, how these color-change responses might relate to those observed in standard practice.

Reda, Daniel C.↗

Evaluating the energy impact potential of energy efficiency measures for retrofit applications: A case study with U.S. medium office buildings

Quantifying the energy savings of various energy efficiency measures (EEMs) for an energy retrofit project often necessitates an energy audit and detailed whole building energy modeling to evaluate the EEMs; however, this is often cost-prohibitive for small and medium buildings. In order to provide a defined guideline for projects with assumed common baseline characteristics, this paper applies a sensitivity analysis method to evaluate the impact of individual EEMs and groups these into packages to produce deep energy savings for a sample prototype medium office building across 15 climate zones in the United States. We start with one baseline model for each climate zone and nine candidate EEMs with a range of efficiency levels for each EEM. Three energy performance indicators (EPIs) are defined, which are annual electricity use intensity, annual natural gas use intensity, and annual energy cost. Then, a Standard Regression Coefficient (SRC) sensitivity analysis method is applied to determine the sensitivity of each EEM with respect to the three EPIs, and the relative sensitivity of all EEMs are calculated to evaluate their energy impacts. For the selected range of efficiency levels, the results indicate that the EEMs with higher energy impacts (i.e., higher sensitivity) in most climate zones are high-performance windows, reduced interior lighting power, and reduced interior plug and process loads. However, the sensitivity of the EEMs also vary by climate zone and EPI; for example, improved opaque envelope insulation and efficiency of cooling and heating systems are found to have a high energy impact in cold and hot climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Determination of noise equivalent reflectance for a multispectral scanner: A scanner sensitivity study

The methods used to calculate the sensitivity parameter noise equivalent reflectance of a remote-sensing scanner are explored, and the results are compared with values measured over calibrated test sites. Data were acquired on four occasions covering a span of 4 years and providing various atmospheric conditions. One of the calculated values was based on assumed atmospheric conditions, whereas two others were based on atmospheric models. Results indicate that the assumed atmospheric conditions provide useful answers adequate for many purposes. A nomograph was developed to indicate sensitivity variations due to geographic location, time of day, and season.

Gibbons, D. E.↗

Structural design utilizing updated, approximate sensitivity derivatives

A method to improve the computational efficiency of structural optimization algorithms is investigated. In this method, the calculations of 'exact' sensitivity derivatives of constraint functions are performed only at selected iterations during the optimization process. The sensitivity derivatives utilized within other iterations are approximate derivatives which are calculated using an inexpensive derivative update formula. Optimization results are presented for an analytic optimization problem (i.e., one having simple polynomial expressions for the objective and constraint functions) and for two structural optimization problems. The structural optimization results indicate that up to a factor of three improvement in computation time is possible when using the updated sensitivity derivatives.

Scotti, Stephen J.↗

Microdisc gel electrophoresis in sodium dodecyl sulfate of organic material from rat otoconial complexes

The gravity receptors of all vertebrates utilize a 'test mass' consisting of a complex arrangement of mineral and organic substance that lies over the sensory receptor areas. In most vertebrates, the mineral is a polymorph of calcium carbonate in the form of minute, single crystals called otoconia. An investigation is conducted to determine the number of proteins in otoconial complexes and their molecular weights. The investigation makes use of a microdisk gel electrophoresis method reported by Gainer (1971). The most important finding of the reported research is that analysis of the proteins of the organic material of the otoconial complexes is possible when sensitive microanalytical methods are employed. Further modification of the basic technique employed and the inclusion of other sensitive staining methods should mean that, in the future, protein separation by molecular weight will be possible in sample pools containing only two otoconial masses.

Ross, M. D.↗

Implementation of efficient sensitivity analysis for optimization of large structures

The paper presents the theoretical bases and implementation techniques of sensitivity analyses for efficient structural optimization of large structures, based on finite element static and dynamic analysis methods. The sensitivity analyses have been implemented in conjunction with two methods for optimization, namely, the Mathematical Programming and Optimality Criteria methods. The paper discusses the implementation of the sensitivity analysis method into our in-house software package, AutoDesign.

Umaretiya, J. R.↗

Brewster-plate spoiler - A novel method for reducing the amplitude of interference fringes that limit tunable-laser absorption sensitivities

A simple method is described for substantially reducing the amplitude of interference fringes that limit the sensitivities of tunable-laser high-resolution absorption spectrometers. A lead-salt diode laser operating in the 7-micron region is used with a single Brewster-plate spoiler to reduce the fringe amplitude by a factor of 30 and also to allow the detection of absorptances 0.001 percent in a single laser scan without subtraction techniques, without complex frequency modulation, and without distortion of the molecular line-shape signals. Application to multipass-cell spectrometers is described.

Webster, C. R.↗

An Antibody Cocktail-Based Immunoaffinity-LC-MS Method Enabled Ultra-Sensitive and Robust Quantification of Circulating Proinsulin Proteoforms and C-Peptide

Accurately measuring circulating proinsulin proteoforms is crucial for clinical investigation of diabetes, but was previously not feasible owing to limited assay specificity/sensitivity. Here, in this study, we devised a highly sensitive LC-MS-based strategy to quantify intact proinsulin, des-31,32 and des-64,65 proinsulin, and C-peptide in circulation. The method involves: (i) quantitative, robust affinity capture using an optimized antibody cocktail, eliminating the severe quantitative bias across multiple proteoforms typically introduced when using a single antibody; (ii) Lys-C digestion producing unique signature peptides for each proteoform, and (iii) trapping-nano-LC coupled with FAIMS/dCV-MS for an ultrasensitive analysis. The selective trapping/delivery ensured sensitive/selective analysis of the targets while achieving excellent analytical robustness that is critical for clinical assays, and the FAIMS/dCV substantially reduces baseline noise/interferences, further enhancing S/N. The assay achieved exceptional sensitivity, with serum LOQs of 1.7, 2.3, and 3.6 pg/mL respectively for intact-proinsulin, des-31,32 and des-64,65, representing the first assay capable of sensitively quantifying these major circulating proinsulin proteoforms. We applied this assay to 78 subjects, including autoantibody positive (n = 20) and new-onset type 1 diabetes (T1D, n = 19) with respective age/sex/BMI-matched controls, enabling the first accurate profiling of proinsulin proteoforms in clinical groups. The assay results demonstrated a clear separation of control and new-onset T1D groups that a parallel total-proinsulin ELISA assay fails to capture. Furthermore, distinct expression patterns in relative abundance ratios among proteoforms were observed across clinical groups. This assay may provide valuable insights into the β-cell functions and the onset/progression of diabetes and other associated conditions. Moreover, the strategy is broadly applicable to targeted measurement of other biomarker proteoforms.

Shen, Qingqing [University at Buffalo, NY (United ↗