Search NASA⌕ Search

SEARCH · Search NASA

Results for “separability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Novel Separation of Actinides

The separation of actinides and other elements of interest for nuclear forensics and threat reduction is currently performed using decades-old chemistries and ion-exchange columns. We propose to determine the technical feasibility of a novel method for separating actinide ions in solution. This method is based upon isotachophoresis (ITP), which has been applied in the purification of pharmaceuticals and other biochemical applications. This technique has the potential to separate inorganic ions more effectively than existing methods, which is key to analyzing very small samples. We will perform a quantitative assessment of the effectiveness of specific isotachophoretic approaches including predicting the physical and chemical properties, such as ion mobility, of inorganic ions under specific solvent conditions using a combination of ab initio calculations and semi-empirical methods. We expect to obtain a thorough understanding of the analytical systems parameters under which ITP is most effective for the separation of inorganic samples, including the influence of the double layer surrounding actinide ions, the Debye length for different ions and ion complexes, and Debye-Hueckel limits. Inorganic separations are key to nuclear forensics for countering terrorism and nuclear proliferation. If found to be feasible and potentially superior to currently used separation approaches, ITP could provide the conceptual basis for an improved means to separate samples of nuclear explosion debris for nuclear forensic analysis, in support of the Laboratory's missions in homeland and national security.

42 ENGINEERING↗

Separation of CO 2 from Flue Gas and Potential for Geologic Sequestration

The objectives of this study were to review various methods reported in the literature for the separation and geologic sequestration of carbon dioxide and evaluate the potential of TVA fossil fuel-burning plant locations for onsite geologic sequestration of CO 2 from stack emissions. Several conventional and nonconventional technologies for the separation of CO 2 from flue gas, including absorption, adsorption, cryogenic distillation, membranes, hydrate formation and dissociation, and ammonia carbonation, have been reviewed in terms of separation mechanisms, flow diagrams, and costs. Most of the technologies that have been reviewed are still at the research and development stage. Critical information needed to assess and compare these technologies is still lacking. In addition, information on some of the technologies that have been tested at a pilot or industrial scale has not been fully disclosed in the open literature. Because of this lack of data, it is difficult to make a critical assessment of each of the separation technologies. Based on limited information, it was concluded that the most promising methods are membrane separation and the Mitsubishi process for chemical absorption. Both processes involve separating CO 2 at high temperature, minimizing the cost for cooling prior to separation. Physical and chemical geologic formations of CO 2 were also reviewed. It was concluded that due to the geologic time scale of CO 2 sequestration periods, relatively safe conditions, general proximity to CO 2 sources, and extensive knowledge of underground conditions, sequestration of CO 2 in underground aquifers and coal beds is a very promising method of mitigating greenhouse gas emissions. The cost is predicted to be relatively low and the suitable sites are numerous for this application, with many of these sites located close to the plants.

20 FOSSIL-FUELED POWER PLANTS↗

Study on Electrostatic Separation of Quinoline Insolubles from Coal Tar Pitch

The feasibility of electrical separation in the removal of quinoline insoluble (QI) particles from coal tar pitch (CTP) was experimentally investigated. QI particle involvement prohibits the effective fabrication of high-quality value-added products, such as carbon fibers, from CTP. A substantial and sustainable CTP market exists around the world; therefore, a strong incentive exists to develop a viable technical approach to effectively and economically remove QI particles from CTP. The electrical separation method shows promise to achieve this technical goal (Cao et al., 2012). Even with the given setup (wire- cylinder adapted), critical issues remain to be addressed for this method to be applicable to the CTP: (1) identifying the wash oil used in the original QI separation, (2) understanding the mechanism of QI separation, (3) characterizing the deposit, and (4) identifying the QI. This study integrated a set of experimental and analysis techniques into the electrical separation tests to address the aforementioned issues. Key findings are as follows: 1. Electric current responses: • The electric current level of the CTP–wash oil solution reported by Cao et al. (2012) can be attained by using a mixture of 25% quinoline and 75% toluene for the CTPs examined in this study under the same electrical load condition. • The electric current tends to decrease during the test period because of the decreasing number of charged particles. • The reversed field corresponded to the configuration of electrostatic precipitation for positive corona discharge. The high electric field can result in dielectric breakdown and lead to an abrupt current surge. 2 Deposit response and solvent candidates: • Deposit of particles in CTP mixture can be effectively implemented in a wire-cylinder configuration as proposed and examined in this study. • Deposit depends on the solvents. Among the solvents tested, two- and three-part solvents that included quinoline and ethanol (i.e., 25% quinoline and 75% toluene; 50% quinoline and 50% toluene; and 33% wash oil, 33% BTX, and 34% ethanol) produced the highest deposit weight. • The deposit process examined in this study is derived from the charged particles. An appreciable relation exists between deposit weight and electric charge. 3. QI removal efficiency (RE): • The RE of the electrostatic separation can reach as high as 76.2% for Carbores, and 61.6% for Koppers. • The RE can be further enhanced if the field level increases from 0.16 kV/mm that was used in the current study to 0.23 kV/mm, according to the relation established between the RE and the electric field. 4. Testing of the modeling system: • The motion of particles is originally driven by the charge-based electric force in the cases tested. The solid particle separation mechanism is similar to that of QI deposition in CTP. • The mechanical movement of solid particles can be strongly affected by the gravitational and viscous forces in the electric field. 5. EDS analysis and chemical compositions: • The main chemical composition of deposit QI matches that of as-prepared CTP QI. The deposit QI is derived from the same group of the CTP QI. • In addition to carbon, the QI contains oxygen, sodium, aluminum, silicon, iron, and sulfur. The work for the near future is also discussed.

01 COAL, LIGNITE, AND PEAT↗

Using Separation-Enhanced Isotope Ratio Mass Spectrometry to Enable Increased Renewable Carbon Content in Transportation Fuels (CRADA 525)

Stable isotope ratio measurements of carbon atoms using isotope ratio mass spectrometry (IRMS) can be an effective tool for quantifying biogenic carbon in co-processed fuels, with results approaching the precision and accuracy of accelerator mass spectrometry (AMS). The lower cost of an IRMS may enable deployment to refineries, improving access and analysis turnaround times (≤2 hours), and, by extension, provide data that can allow process optimization to maximize renewable carbon in desired refinery products. This project explored the integration of chemical separation with IRMS analyses to enable highly detailed tracking of biogenic carbon into fuel product streams separated by boiling point range, chemical class, or specific compound. Forty-nine fuels and fuel components of fossil and biogenic origin, spanning gasoline and diesel boiling point ranges, were received from three refiners and were analyzed for their δ 13 C values via IRMS. Results spanned a 13 C range from ca. 10‰ to 44‰ and reflect materials derived from sustainable sources (e.g., C4 or C3 plants, animal-based pathways, syngas) or from fossil-derived fuels. Common ranges are approximately 18‰ to 9‰ and approximately 30‰ to 20‰ for C4 and C3 plants, respectively, and approximately 34‰ to 24‰ and approximately 70‰ to 33‰ for petroleum-derived fuels and methane, respectively. Fuel-like standards were developed and tested using direct-injection elemental analyzer (EA) IRMS for liquid fuels. This method was compared with the published methods, yielding statistically similar results. Four blend curve sets were produced ranging from 0% to 100% of a fuel containing biogenic carbon, focusing on 0% to 10% biogenic carbon. Linear fits were the most applicable for two of the four blend curve sets; however, two sets were found to exhibit slightly quadratic behavior, which was more pronounced in low biogenic blend samples, necessitating second-order fits. The origin of the slight quadratic behavior remains unclear; however, the discussion points to possible interpretations. CanmetENERGY thoroughly characterized a majority of the samples using one- and two-dimensional gas chromatography (GC and GC×GC, respectively) and other analyses. Selected samples were subjected to solid phase extraction (SPE) for saturate, olefin, aromatic, and polar (SOAP) analysis, and the resulting solvent-diluted fractions containing saturates and aromatics were returned to Pacific Northwest National Laboratory (PNNL), where the solvent was removed via evaporation or physical separation using GC techniques. Characterization and separations provided an understanding of saturate and aromatic content, as well as boiling point ranges for each sample and sample fraction. Samples resulting from SPE were examined using EA-IRMS and gas chromatography combustion IRMS (GC-C-IRMS) analyses. Both approaches suggest that the range in values between end-members can be increased by selecting the paraffinic or aromatic fraction of the end-member or by selecting among individual compounds resulting from GC separation of the paraffinic fractions. Considerable work remains to put these approaches into practice and statistically validate the benefit for using a fraction or individual compound over bulk analysis of a sample. However, initial results suggest that separations provide advantages for samples having blend ratios of less than 10% biogenic blendstocks. 13 C results showed statistically similar biofuel blend results to those obtained at PNNL, although additional work is needed to obtain better reproducibility. Select samples were sent to Los Alamos National Laboratory (LANL) for IRMS measurements and Beta Analytics for AMS measurements. This work suggests that IRMS and AMS yield closely comparable results and in some circumstances, IRMS could serve as a surrogate for AMS. While additional work is needed to better resolve statistical advantages for separations and better show the comparable nature of IRMS and AMS in both the biogenic carbon analysis of bulk chemical classes, initial results from this study suggest that these should be pursued in order to proliferate this approach for quantifying biogenic carbon in transportation fuels to the refinery level, thereby potentially enabling process optimization in co-processing scenarios.

09 BIOMASS FUELS↗

Cosmogenic 3 He exposure dating in mafic rocks by “Virtual mineral separation” of pyroxene

We describe a “virtual mineral separation” method for measuring the cosmogenic 3 He concentration in pyroxene in mafic rocks that consist mainly of plagioclase and pyroxene, without physically separating the minerals. This approach is significantly faster and more cost-effective than the conventional method, which requires physical separation and purification of pyroxene grains by time-consuming and labor-intensive crushing, acid cleaning, magnetic separation, HF etching, and handpicking under a microscope. The premise of the method is that helium diffusivity is much higher in plagioclase than in pyroxene, so controlled preheating of a mixed whole-rock sample can degas 3 He from plagioclase while retaining all 3 He in pyroxene. A second heating step releases all 3 He from pyroxene for measurement. To then obtain a 3 He concentration in pyroxene rather than the whole rock, we determine the pyroxene weight fraction in the sample using X-ray computed tomography (CT). A comparison of 3 He concentrations in pyroxene measured using virtual mineral separation with those measured in the same samples by physical mineral separation in previous work shows no evidence of systematic bias between the methods. Virtual mineral separation greatly simplifies the workflow for 3 He exposure-dating of mafic rocks, reduces time, effort, and cost, and permits measurements on very small samples. This enables new emerging applications of exposure dating, such as quantifying stochastic surface processes, ecosystem studies, and potential subglacial bedrock exposure dating.

Geosciences↗

Monte Carlo analysis of thermochromatography as a fast separation method for nuclear forensics

Nuclear forensic science has become increasingly important for global nuclear security, and enhancing the timeliness of forensic analysis has been established as an important objective in the field. New, faster techniques must be developed to meet this objective. Current approaches for the analysis of minor actinides, fission products, and fuel-specific materials require time-consuming chemical separation coupled with measurement through either nuclear counting or mass spectrometry. These very sensitive measurement techniques can be hindered by impurities or incomplete separation in even the most painstaking chemical separations. High-temperature gas-phase separation or thermochromatography has been used in the past for the rapid separations in the study of newly created elements and as a basis for chemical classification of that element. This work examines the potential for rapid separation of gaseous species to be applied in nuclear forensic investigations. Monte Carlo modeling has been used to evaluate the potential utility of the thermochromatographic separation method, albeit this assessment is necessarily limited due to the lack of available experimental data for validation.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Manipulating Polyimide Nanostructures via Cross linking for Membrane Gas Separation

Cross-linking has been widely utilized to modify polyimide nanostructures for membrane gas separations, such as increasing size sieving ability and diffusivity selectivity for H2/CO2 and CO2/CH4 separation, and improving resistance to plasticization derived from CO2 and heavy hydrocarbons for CO2/CH4 and C3H6/C3H8 separations. However, there is a lack of fundamental understanding of the relationship between cross linked structure and membrane gas separation properties. This chapter critically reviews the effect of cross linking on polymer physical properties (such as glass transition temperature, Tg), and current strategies adopted to cross link polyimides for membrane gas separation. The information is synthesized to elucidate the effect of cross linking on Tg and cross linking density in polyimides, which is then used to interpret the changes of gas permeability and selectivity. The benefits of cross linking in improving gas separation properties are also illustrated in Robeson’s upper bound plots for H2/CO2, CO2/CH4 and C3H6/C3H8 separation.

08 HYDROGEN↗

Co-extruded conformal battery separator and electrode

A co-extrusion print head has at least one separator inlet port, at least a first, second and third series of channels arranged to receive a separator material from the separator inlet port, at least one electrode inlet port, a fourth series of channels arranged to receive an electrode material from the electrode inlet port, a first merge portion connected to the first, second, third and fourth series of channels, the merge portion positioned to receive and merge the separator material into a separator flow and the electrode material into an electrode flow, a second merge portion connected to the first merge portion, the second merge portion positioned to receive and merge the separator flows and the electrode flows, and an outlet port connected to the second merge portion, the outlet port arranged to deposit the separator and electrode materials from the merge portion as a stack on a substrate.

25 ENERGY STORAGE↗

25 years of environmental remediation in the general separations area of the Savannah river site: lessons learned about what worked and what did not work in soil and groundwater cleanup - 15270

The Savannah River Site, which is owned and administered by the US Department of Energy, covers approximately 900 square kilometers. The General Separation Area is located in the center of the site and includes: radioactive material chemical separations facilities, radioactive waste tank farms, radioactive seepage basins, and the radioactive waste burial grounds. Radioactive wastes were disposed in the General Separation Area from the mid-1950's through the mid-1990's. Operations at the F Canyon began in 1954 and at H Canyon began in 1955. Waste water disposition to the F and H Seepage Basins began soon after operations started in the canyons. The Old Radioactive Waste Burial Ground began operations in 1952 to manage solid waste that could be radioactive from all the site operations, and ceased receiving waste in 1972. The Mixed Waste Management Facility and Low Level Radioactive Waste Disposal Facility received radioactive solid waste from 1969 until 1995. Environmental legislation enacted in the 1970's through 1990's led to changes in waste management and environmental cleanup practices. The US Congress passed the Clean Air Act in 1970 and the Clean Water Act in 1972; the Resource Conservation and Recovery Act was enacted in 1976; the Comprehensive Environmental Response Compensation, and Liability Act was enacted by Congress in 1980; and the Federal Facilities Compliance Act was signed into law in 1992. Environmental remediation at the Savannah River Site essentially began with a 1987 Settlement Agreement between the Savannah River Site and the State of South Carolina. The site manages several of the larger groundwater remedial activities under the Resource Conservation and Recovery Act for facilities recognized early on as environmental problems. All subsequent remediation projects are managed under a tri-party agreement (Department of Energy, Environmental Protection Agency, and South Carolina Department of Health and Environmental Control) through the Federal Facilities Agreement. Environmental remediation activities during the past 25 years have stabilized and capped seepage basins as well as consolidated and capped waste units and burial grounds in the General Separation Area. Groundwater activities include: pump and treat systems in the groundwater, installation of deep subsurface barrier systems to manage groundwater flow, in situ chemical treatments in the groundwater, and captured contaminated groundwater discharges at the surface for management in a forest irrigation system. Concentrations of contaminants in the aquifers beneath the General Separation Area and in surface water streams in the General Separation Area have decreased over the past 25 years. Closure of 65 waste sites and 4 Resource Conservation and Recovery Act facilities has been successfully accomplished. Environmental clean-up has progressed to the stage where most of the work involves monitoring, optimization, and maintenance of existing remedial systems. Many lessons have been learned in the process of remediating the General Separations Area. Geo-textile covers outperform low permeability clay caps, especially with respect to the amount of repairs required to upkeep the drainage layers as the caps age. Passive and enhanced natural processes to address contamination are much more cost effective than pump and treat systems. Forest irrigation can be very effective in water management situations with non-accumulative contaminants such as tritium and volatile organic contaminants. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Automation of Extraction Chromatograhic and Ion Exchange Separations for Radiochemical Analysis and Monitoring

Radiochemical analysis, complete with the separation of radionuclides of interest from the sample matrix and from other interfering radionuclides, is often an essential step in the determination of the radiochemical composition of a nuclear sample or process stream. Although some radionuclides can be determined nondestructively by gamma spectroscopy, where the gamma rays penetrate significant distances in condensed media and the gamma ray energies are diagnostic for specific radionuclides, other radionuclides that may be of interest emit only alpha or beta particles. For these, samples must be taken for destructive analysis and radiochemical separations are required. For process monitoring purposes, the radiochemical separation and detection methods must be rapid so that the results will be timely. These results could be obtained by laboratory analysis or by radiochemical process analyzers operating on-line or at-site. In either case, there is a need for automated radiochemical analysis methods to provide speed, throughput, safety, and consistent analytical protocols. Classical methods of separation used during the development of nuclear technologies, namely manual precipitations, solvent extractions, and ion exchange, are slow and labor intensive. Fortunately, the convergence of digital instrumentation for preprogrammed fluid manipulation and the development of new separation materials for column-based isolation of radionuclides has enabled the development of automated radiochemical analysis methodology. The primary means for separating radionuclides in solution are liquid-liquid extraction and ion exchange. These processes are well known and have been reviewed in the past.1 Ion exchange is readily employed in column formats. Liquid-liquid extraction can also be implemented on column formats using solvent-impregnated resins as extraction chromatographic materials. The organic liquid extractant is immobilized in the pores of a microporous polymer material. Under suitable conditions, the analyte of interest partitions into the immobilized organic phase while other matrix speces and interferences are washed away in the mobile aqueous phase. After the wash step, retained analytes are rapidly released in one or more steps by changing the aqueous eluent, such that the analytes now partition back into the mobile phase. The development of solvent impregnated resins, their physical chemistry, technological applications for metal and radionuclide recovery, and analytical uses were described in detail in a previous chapter in this series by Cortina and Warshawsky. The extraction chromatographic approach is well suited for the isolation of radionuclides from complex sample matrixes in a rapid automated format. The development of automated radioanalytical methods is, in fact, closely coupled to the availability of such materials. In this review, we will focus on the application of radiochemical separations in automated fluidic formats for the analysis of alpha- and beta-emitting radionuclides.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Metal–Organic Frameworks for C6 Alkane Separation

The separation of alkane isomers is an important yet challenging process in the petrochemical industry. Being a crucial step to produce premium gasoline components as well as optimum ethylene feed, the current industrial separation by distillation is extremely energy intensive. Adsorptive separation based on zeolite is limited by insufficient adsorption capacity. Metal-organic frameworks (MOFs) hold enormous promise as alternative adsorbents due to their diverse structural tunability and exceptional porosity. Precise control of their pore geometry/dimensions has led to superior performance. In this minireview, we highlight the recent progresses in developing MOFs for the separation of C6 alkane isomers. Representative MOFs are reviewed based on their separation mechanisms. Emphasis is put on the material design rationale for achieving optimal separation capability. Lastly, we briefly discuss the existing challenges, possible solutions, and future directions of this important field.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Actinide Lanthanide Separation Process – ALSEP

Separation of the minor actinides (Am, Cm) from the lanthanides at an industrial scale remains a significant technical challenge for closing the nuclear fuel cycle. To increase the safety of used nuclear fuel (UNF) reprocessing, as well as reduce associated costs, a novel solvent extraction process has been developed. The process allows for partitioning minor actinides, lanthanides and fission products following uranium/plutonium/neptunium removal; minimizing the number of separation steps, flowsheets, chemical consumption, and waste. This new process, Actinide Lanthanide SEParation (ALSEP), uses an organic solvent consisting of a neutral diglycolamide extractant, either N,N,N',N'-tetra(2 ethylhexyl)diglycolamide (T2EHDGA) or N,N,N',N'-tetraoctyldiglycolamide (TODGA), and an acidic extractant 2-ethylhexylphosphonic acid mono-2-ethylhexyl ester (HEH[EHP]), dissolved in an aliphatic diluent (e.g. n-dodecane). The An/Ln co-extraction is conducted from moderate-to-strong nitric acid, while the selective stripping of the minor actinides from the lanthanides is carried out using a polyaminocarboxylic acid/citrate buffered solution at pH anywhere between 3 and 4.5. The extraction and separation of the actinides from the fission products is very effective in a wide range of HNO3 concentrations and the minimum separation factors for lanthanide/Am exceed 30 for Nd/Am, reaching > 60 for Eu/Am under some conditions. The experimental results presented here demonstrate the great potential for a combined system, consisting of a neutral extractant such as T2EHDGA or TODGA, and an acidic extractant such as HEH[EHP], for separating the minor actinides from the lanthanides.

actinide separation↗

An Advanced TALSPEAK Concept for Separating Minor Actinides. Part 2. Flowsheet Test with Actinide-spiked Simulant

A solvent extraction system has been developed for separating trivalent actinides from lanthanides. This “Advanced TALSPEAK” system uses 2-ethylhexylphosphonic acid mono-2-ethylhexyl ester to extract the lanthanides into a n-dodecane-based solvent phase, while the actinides are retained in a citrate-buffered aqueous phase by complexation to N-(2-hydroxyethyl)ethylenediamine-N,N',N'-triacetic acid. Batch distribution measurements indicate that the separation of americium from the light lanthanides decreases as the pH decreases. For example, the separation factor between La and Am increases from 2.5 at pH 2.0 to 19.3 at pH 3.0. However, previous investigations indicated that the extraction rates for the heavier lanthanides decrease with increasing pH. So, a balance between these two competing effects is required. An aqueous phase in which the pH was set at 2.6 was chosen for further process development because this offered optimal separation, with a minimum separation factor of ~8.4, based on the separation between La and Am. Centrifugal contactor single-stage efficiencies were measured to characterize the performance of the system under flow conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoporous Polytetrafluoroethylene/Silica Composite Separator as a High-Performance All-Vanadium Redox Flow Battery Membrane

Driven by the motivation of searching for low-cost membrane alternatives, a novel nanoporous polytetrafluoroethylene/silica composite separator has been prepared and evaluated for its use in all-vanadium mixed-acid redox flow battery. This separator consisting of silica particles enmeshed in a polytetrafluoroethylene fibril matrix has no ion exchange capacity and is featured with unique nanoporous structures, which function as the ion transport channels in redox flow battery operation, with an average pore size of 38nm and a porosity of 48%. This separator has produced excellent electrochemical performance in the all-vanadium mixed-acid system with energy efficiency delivery comparable to Nafion membrane and superior rate capability and temperature tolerance. The separator also demonstrates an exceptional capacity retention capability over extended cycling, offering additional operational latitude towards conveniently mitigating the capacity decay that is inevitable for Nafion. Because of the inexpensive raw materials and simple preparation protocol, the separator is particularly low-cost, estimated to be at least an order of magnitude more inexpensive than Nafion. Plus the proven chemical stability due to the same backbone material as Nafion, this separator possesses a good combination of critical membrane requirements and shows great potential to promote market penetration of the all-vanadium redox flow battery by enabling significant reduction of capital and cycle costs.

all-vanadium redox flow battery↗

Membrane Separations in Biomass Processing

The development of integrated biorefineries and the greater utilization of biomass resources to reduce dependence on fossil fuel-derived products require research emphasis not just on conversion strategies but also on improving separations associated with biorefining. A significant roadblock towards developing biorefineries is the lack of effective separation techniques evidenced by the relative deficiency of literature in this area. Additionally, high conversion yields may only be realized if effective separations generate feedstock of sufficient purity – this makes research into biomass conversion strategies all the more critical. In this review, the challenges associated with biomass separations are discussed, followed by an overview of the most appropriate separation strategies for processing biomass. One of the unit operations most appealing for biorefining, membrane separations (MS), is then considered along with a review of the recent literature utilizing this technique in biomass processing.

09 BIOMASS FUELS↗

Evaluation of hydrograph separation techniques with uncertain end-member composition

Hydrograph separation is one of many approaches used to analyse shifts in source water contributions to stream flow resulting from climate change in remote watersheds. Understanding these shifts is vital, as shifts in source water contributions to a stream can shape water management decisions. Because remote watersheds are often inaccessible and have poorly characterized contributing water sources, or end-members, it is critical to understand the implications of using different hydrograph separation techniques in these data-limited environments. To explore the uncertainty associated with different techniques, results from two hydrograph separation techniques, mass balance and principle component analysis, were compared using 3 years of aqueous geochemical data from the East River watershed located in the Elk Mountains of Central Colorado. Solute concentrations of the end-members were characterized by both a limited set of direct chemical measurements of different sources and detailed seasonal instream chemistry to examine the influences of uncertain end-member compositions in a data-limited environment. Annual volumetric end-member contributions to stream flow had relatively good agreement across separation techniques. Large variations in time were observed in the hydrograph separations, depending on the end-member type, and estimated flow contributions varied between the selected solutes. End-member concentrations characterized by stream chemistry showed several limitations including a reduced number of distinguishable end-members and differences in timing of flow contributions. Here the results highlight the benefits of using multiple hydrograph separation techniques by providing a ‘weight-of-evidence’ approach to environments with limited end-member concentration data.

54 ENVIRONMENTAL SCIENCES↗

In‐Process Melt Separation of PE/PET Blends for Upcycling via Twin‐Screw Extrusion. Impact of Catalyst Reagents on PET Depolymerization

Part 1 of this work focused on depolymerizing polyethylene terephthalate (PET) in twin-screw extrusion, as part of a broader project to continuously separate PET from polyolefins in the melt. This study focused on linear low-density polyethylene (LLDPE) and PET films and the use of ethylene glycol (EG), diethylene glycol (DEG), triethylene glycol (TEG), and bis(2-hydroxyethyl) terephthalate (BHET) to depolymerize the PET in the extruder to levels above 90% Mw. In part 2, the focus will shift to achieving separation of the two polymers in the twin-screw extruder, which is made possible due to a 90% reduction in the Mw of the PET, which caused a decrease of its viscosity by several orders of magnitude. Owing to the viscosity difference and pressure buildup in the die, the low-viscosity PET preferentially exited a degassing vent instead of going through the die. This is because the flow of the PET would travel through a non-pressure vent rather than through a high-pressure die. However, owing to the higher viscosity of the LLDPE, the pressure was too high to pass through such a small diameter vent hole. Supercritical CO₂ (SCCO₂) was used to assist in this extraction, but SCCO₂ negatively impacted the overall degree of separation. Through analysis of the separated materials, it was concluded that a very high separation of the two materials was achieved. TGA and FTIR confirmed that the material separated from the vent was 100% PET. The material removed from the die was composed of 90% LLDPE and 10% PET.

36 MATERIALS SCIENCE↗

Development of a variable tensioning system to reduce separation force in large scale stereolithography

Projection micro stereolithography (PµSL) is an additive manufacturing tool that offers multiple advantages, including unparalleled resolution and throughput, but the ability to print high viscosity resin for large-scale parts is limited. One of the key challenges in PµSL is to separate a newly polymerized layer from the vat floor without damaging the part. Since the separation force scales with the printing area, the risk of damaging the part increases significantly with larger-scale systems and must be addressed. In this paper, a novel roll-to-roll, variable tensioning system is proposed to reduce the separation force during printing. A mathematical model is proposed to predict the separation force for different 2D geometries, and a set of experiments is conducted on an experimental prototype to validate the model. Finally, the effects of different separation parameters including peel rate and peel angle are discussed in detail. The results show that the proposed tensioning system reduces the separation force significantly.

36 MATERIALS SCIENCE↗