Search NASA⌕ Search

SEARCH · Search NASA

Results for “shape approximation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Diverse Long-term Variability of Five Candidate High-mass X-Ray Binaries from Swift Burst Alert Telescope Observations

We present an investigation of long-term modulation in the X-ray light curves of five little-studied candidate high-mass X-ray binaries using the Swift Burst Alert Telescope. IGR J14488-5942 and AX J1700.2-4220 show strong modulation at periods of 49.6 and 44 days, respectively, which are interpreted as orbital periods of Be star systems. For IGR J14488-5942, observations with the Swift X-ray Telescope show a hint of pulsations at 33.4 s. For AX J1700.2-4220, 54 s pulsations were previously found with XMM-Newton . Swift J1816.7-1613 exhibits complicated behavior. The strongest peak in the power spectrum is at a period near 150 days, but this conflicts with a determination of a period of 118.5 days by La Parola et al. AX J1820.5-1434 has been proposed to exhibit modulation near 54 days, but the extended BAT observations suggest modulation at slightly longer than double this at approximately 111 days. There appears to be a long-term change in the shape of the modulation near 111 days, which may explain the apparent discrepancy. The X-ray pulsar XTE J1906+090, which was previously proposed to be a Be star system with an orbital period of ∼30 days from pulse timing, shows peaks in the power spectrum at 81 and 173 days. The origins of these periods are unclear, although they might be the orbital period and a superorbital period respectively. For all five sources, the long-term variability, together with the combination of orbital and proposed pulse periods, suggests that the sources contain Be star mass donors.

79 ASTRONOMY AND ASTROPHYSICS↗

Microscopic description of large-amplitude shape-mixing dynamics with local QRPA inertial functions

We introduce a microscopic approach to derive all the inertial functions in the five-dimensional quadrupole collective Hamiltonian. Local normal modes are evaluated on the constrained mean field in the quasiparticle random-phase approximation in order to derive the inertial functions. The collective Hamiltonians for neutron-rich Mg isotopes are determined with use of this approach, and the shape coexistence/mixing around the N = 20 region is analyzed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Intrinsic dosimetry of glass containers: A potential interrogation tool for nuclear forensics and waste management

Intrinsic dosimetry is the method of measuring total absorbed dose received by the walls of a container holding radioactive material. By considering the total absorbed dose received by a container in tandem with the physical characteristics of the radioactive material housed within that container, this method has the potential to provide law enforcement officials or waste management personnel with enhanced pathway information regarding the history of the container and its radioactive contents. We report the latest in a series of experiments designed to validate and demonstrate this newly developed tool. Thermoluminescence (TL) dosimetry was used to measure dose effects on the raw stock material of borosilicate container glass with time up to 60 days after gamma ray, x-ray, beta particle or ultraviolet irradiations at doses from 0.15 to 20 Gy. Two peaks were identified in the TL glow curve when irradiated with 60Co, a relatively unstable peak around 120°C and a more stable peak around 225°C. Signal strength of both peaks decayed with time. The minimum measurable dose using this technique was measured to be 0.15 Gy, which is roughly equivalent to a 24 hr irradiation at 1 cm from a 50 ng source of 60Co. After fading, this dose would still be observable approximately 1 year post-irradiation. Similar doses with beta particles and x-rays produced TL glow curves of lower intensity. The TL glow curves were separated into five peaks centered at approximately 120, 160, 225, 300, and 340°C. Differences in TL glow curve shape and intensity were observed for the glasses from different geographical origins. These differences can be explained by changes in the intensities of the five peaks. EPR results showed production of BOHC and E’ silica centers.

Clark, Richard A.↗

Probing the localization of magnetic dichroism by atomic-size astigmatic and vortex electron beams

We report localization of a magnetic dichroic signal on atomic columns in electron magnetic circular dichroism (EMCD), probed by beam distorted by four-fold astigmatism and electron vortex beam. With astigmatic probe, magnetic signal to noise ratio can be enhanced by blocking the intensity from the central part of probe. However, the simulations show that for atomic resolution magnetic measurements, vortex beam is a more effective probe, with much higher magnetic signal to noise ratio. For all considered beam shapes, the optimal SNR constrains the signal detection at low collection angles of approximately 6–8 mrad. Irrespective of the material thickness, the magnetic signal remains strongly localized within the probed atomic column with vortex beam, whereas for astigmatic probes, the magnetic signal originates mostly from the nearest neighbor atomic columns. Due to excellent signal localization at probing individual atomic columns, vortex beams are predicted to be a strong candidate for studying the crystal site specific magnetic properties, magnetic properties at interfaces, or magnetism arising from individual atomic impurities.

36 MATERIALS SCIENCE↗

Ultra-high (>30%) coupling efficiency designs for demonstrating central hot-spot ignition on the National Ignition Facility using a Frustraum

A new hohlraum geometry or “Frustraum” is proposed that may enable 2–3× higher capsule absorbed x-ray energy than for nominally sized capsules in standard cylinders. The Frustraum geometry comprises two truncated conical halves (or “frusta”) joined at the waist. An associated larger waist volume above the capsule allows fielding ∼50% larger capsules than the nominal 1 mm (radius) scale. A key feature of the Frustraum is that the outer laser cones strike the Frustraum ends at a higher glancing angle (by ∼23°) compared with a cylinder and generate more specular reflection. A scenario for boosted symmetry control from the outer cones reflecting off a glancing angle hohlraum wall depends on the choice of electron flux limit in the simulations. Recent data from the National Ignition Facility using oversized aluminum shells in rugby-shaped hohlraums [Ping et al., Nat. Phys. 15, 138 (2019)] come closest to approximating a Frustraum and are consistent with a flux limit of 0.03–0.04 in matching the simulated Dante drive history, the backlit trajectory of the Al shell, neutron yield, and implosion time. Applying this simulation methodology to hot-spot ignition designs in a Frustraum shows effective symmetry control and sufficient drive (∼290 eV) to enable high yield, moderate convergence implosions. Simulations suggest that adjusting the obliquity of the Frustraum wall is a robust lever for symmetry tuning. A high adiabat (α = 4.6) ignition design with a shortened laser pulse (<7 ns) is proposed to provide further margin to potential late-time loss of symmetry control from hohlraum filling and anomalous sources of fuel preheat.

Amendt, Peter↗

Argon metastable density and temperature of a 43 GHz microplasma

Argon (1s 5 ) metastable density and translational gas temperature are experimentally measured using laser diode absorption spectroscopy within a 43 GHz microplasma. The plasma is initiated and sustained within a photonic crystal constructed from a rectangular array of alumina rods, each 1 mm in diameter. This configuration generates stable microplasma from 10 to 600 Torr using millimeter wave power from 100 to 1200 mW. The metastable density is in the order of 10 18 m –3 at low pressure. However, Ar(1s 5 ) density decreases to undetectable levels with increasing pressure and wave power. The gas temperature is extracted from the Lorentzian line shape of the absorption profile at 811.53 nm. The gas temperature increases from approximately 400 K at low pressure to 2000 K at 320 Torr (427 mbar, 4.27 × 10 4 Pa). Furthermore, these data are compared with previous results and suggest that the microplasma has a dense core of electrons that depletes the metastable density at high gas pressure and wave power.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The radial phase variation of reversed-shear and toroidicity-induced Alfvén eigenmodes in DIII-D

The eigenfunction of an instability contains information about energy flow in the wave. Here, the amplitude and phase of electron cyclotron emission radiometer data from hundreds of DIII-D reversed shear Alfvén eigenmodes (RSAE) and toroidicity-induced Alfvén eigenmodes (TAE) are analyzed along the outboard horizontal midplane. The radial phase profile can be flat, linearly rising or falling, convex or concave; in other words, a wide variety of shapes is observed. For a particular mode, often the radial phase profile remains approximately constant as the mode evolves in time but sometimes it changes rapidly. Many TAEs and some RSAEs have phase profiles that are rather flat where the mode amplitude is largest but rise steadily by ~2π at large major radius. Rapid phase changes are observed when the frequencies of an RSAE and TAE overlap and the modes couple. The phase profile depends weakly on the fast-ion gradient that would appear in the absence of wave-induced transport. Linear and quadratic fits to the phase profiles, together with many plasma parameters, are assembled into RSAE and TAE databases. In both cases, large variability is observed. For RSAEs, the strongest phase dependencies are on electron temperature T e , RSAE mode frequency, and the density of carbon impurities. For TAEs, the strongest dependencies are on beam power and major radius of the mode. In general, the average RSAE radial phase profile is essentially flat but the TAE profile has non-zero slope and curvature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Use of Neutrino Scattering Events with Low Hadronic Recoil to Inform Neutrino Flux and Detector Energy Scale

Charged-current neutrino interactions with low hadronic recoil ("low-nu") have a cross-section that is approximately constant versus neutrino energy. These interactions have been used to measure the shape of neutrino fluxes as a function of neutrino energy at accelerator-based neutrino experiments such as CCFR, NuTeV, MINOS and MINERvA. In this paper, we demonstrate that low-nu events can be used to measure parameters of neutrino flux and detector models and that utilization of event distributions over the upstream detector face can discriminate among parameters that affect the neutrino flux model. From fitting a large sample of low-nu events obtained by exposing MINERvA to the NuMI medium-energy beam, we find that the best-fit flux parameters are within their a priori uncertainties, but the energy scale of muons reconstructed in the MINOS detector is shifted by 3.6% (or 1.8 times the a priori uncertainty on that parameter). These fit results are now used in all MINERvA cross-section measurements, and this technique can be applied by other experiments operating at MINERvA energies, such as DUNE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electromagnetic analysis of arbitrarily shaped pinched carpets

We derive the expressions for the anisotropic heterogeneous tensors of permittivity and permeability associated with two-dimensional and three-dimensional carpets of an arbitrary shape. In the former case, we map a segment onto smooth curves whereas in the latter case we map an arbitrary region of the plane onto smooth surfaces. Importantly, these carpets display no singularity of the permeability and permeability tensor components. Moreover, a reduced set of parameters leads to nonmagnetic two-dimensional carpets in p polarization (i.e., for a magnetic field orthogonal to the plane containing the carpet). Such an arbitrarily shaped carpet is shown to work over a finite bandwidth when it is approximated by a checkerboard with 190 homogeneous cells of piecewise constant anisotropic permittivity. We finally perform some finite element computations in the full vector three-dimensional case for a plane wave in normal incidence and a Gaussian beam in oblique incidence. The latter requires perfectly matched layers set in a rotated coordinate axis which exemplifies the role played by geometric transforms in computational electromagnetism.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Physics of nanoscale immiscible fluid displacement

In this work, we investigate immiscible fluid displacement at small scales where slip lengths are on the order of characteristic system sizes, whereby Cox's law is not expected to be valid. Molecular dynamics simulations show that in this limit hydrodynamic bending becomes small and interfaces remain approximately spherical. In this case the only relevant angle for describing the interface shape is the dynamic microscopic angle at the fluid-solid interface. In our simulations, this angle is found to be described well by the molecular-kinetic theory originally proposed by Blake and Haynes. In general, this implies a different functional dependence between the contact angle (and related quantities) and the flow speed (or capillary number); this is demonstrated for the case of the force on the boundary for immiscible fluid displacement in a two-dimensional channel.

42 ENGINEERING↗

Direct Measurement of the W Boson Width

We present a direct measurement of the width of the W boson using the shape of the transverse mass distribution of W->enu candidate events. Data from approximately 1 fb{sup -1} of integrated luminosity recorded at sq root(s)=1.96 TeV by the D0 detector at the Fermilab Tevatron pp collider are analyzed. We use the same methods and data sample that were used for our recently published W boson mass measurement, except for the modeling of the recoil, which is done with a new method based on a recoil library. Our result, 2.028+-0.072 GeV, is in agreement with the predictions of the standard model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optimization of a High Pressure Turbine Blade and Sector-Based Annular Rig Design for Supercritical CO2 Power Cycle Representative Testing

Abstract As part of the ongoing research into the design of hardware for zero emission cycles, a first-stage high-pressure turbine (HPT) blade is optimized for a 300 MWe supercritical CO2 (sCO2) power cycle using the surrogate-assisted genetic algorithm optimizer in Numeca FINE/Design three-dimensional with objectives of increasing efficiency and decreasing heat load to the blade. Supercritical CO2 property tables are constructed from NIST REFPROP data for the condensable gas simulation in FINE/Turbo. A detailed mesh sensitivity study is performed for a baseline design to identify the proper-grid refinement and efficiently allocate resources for the optimization. Seventy design variables are selected for the initial population generation. Self-organizing maps are then used to focus the design variables on the most important ones affecting the objective functions. The optimization results in approximately 3000 three-dimensional Reynolds Averaged Navier Stokes simulations of different blade shapes with increases in efficiency of up to 0.85% and decreases in heat load of 14%. Families of blade shapes are identified for experimental testing in an annular rig at the Purdue Experimental Turbine Aerothermal Laboratory. A design to adapt the annular cascade for testing optimized geometries is introduced, which features eccentric radius sectors allowing for scaled-up geometries of sCO2 optimized blade profiles to be tested at design cycle representative conditions at high Reynolds numbers in dry air. Analysis into the effects of Reynolds number, working fluid, and geometric relations are presented to prove the efficacy of the test method.

Engineering↗

Propagation of an ultrawideband electromagnetic signal in ionospheric plasma

The propagation of an ultrawideband electromagnetic signal in the ionosphere—a plasma medium with spatially nonuniform characteristics—is studied analytically in the high-frequency approximation. The effect of the plasma dielectric properties and angular divergence on the shape and frequency spectrum of the propagating signal is investigated. It is shown that the spectral energy density of the signal is preserved if collisions of ionospheric plasma electrons are neglected.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pulse-shape discrimination against low-energy Ar-39 beta decays in liquid argon with 4.5 tonne-years of DEAP-3600 data

The DEAP-3600 detector searches for the scintillation signal from dark matter particles scattering on a 3.3 tonne liquid argon target. The largest background comes from 39 Ar beta decays and is suppressed using pulse-shape discrimination (PSD). We use two types of PSD estimator: the prompt-fraction, which considers the fraction of the scintillation signal in a narrow and a wide time window around the event peak, and the log-likelihood-ratio, which compares the observed photon arrival times to a signal and a background model. We furthermore use two algorithms to determine the number of photons detected at a given time: (1) simply dividing the charge of each PMT pulse by the mean single-photoelectron charge, and (2) a likelihood analysis that considers the probability to detect a certain number of photons at a given time, based on a model for the scintillation pulse shape and for afterpulsing in the light detectors. The prompt-fraction performs approximately as well as the log-likelihood-ratio PSD algorithm if the photon detection times are not biased by detector effects. We explain this result using a model for the information carried by scintillation photons as a function of the time when they are detected.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Installation and Testing of a Jorin Visual Process Analyzer

The Jorin Visual Process Analyzer (ViPA) is an on-line instrument that uses video microscope imaging to detect and measure the physical characteristics of dispersed objects within a process stream or laboratory sample. Object analysis is performed by capturing an on-going sequence of single frames from the video feed and relaying the images in real time to a nearby control computer where the ViPA software then processes and transfigures the information from the images into meaningful process data. The ViPA captures and analyzes approximately 15 images per second and continuously records 17 material parameters including size, shape and optical density. The ViPA software uses the measured parameters to differentiate between different classes of objects including organic droplets, gas bubbles, and solid particles. Procurement of this instrument provides a unique capability to support predictive modeling and further understanding of mass transfer during solvent extraction processes. Organic droplet data collected using the ViPA can be used to develop dispersion profiles of the liquid-liquid mixing and disengagements sections for each type of process equipment. These profiles will provide insight into mixing dynamics and will guide the prevention of emulsion formation that leads to system losses. Additionally, the measurement capabilities of the ViPA will provide the input needed to create new two-phase Computational Fluid Dynamics (CFD) models that characterize both mixing and separation operations in the various types of equipment. These models can then be used to improve process efficiency by optimizing operation parameters for each proposed extraction cycle.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Access to pedestal pressure relevant to burning plasmas on the high magnetic field tokamak Alcator C-Mod

Experiments on the Alcator C-Mod tokamak have utilized reactor-relevant magnetic fields to sustain substantially higher pedestal pressure than in other devices and allow close approach to the ITER H-mode baseline target pedestal pressure of 90 kPa. The EPED model, which couples the physics of transport driven by kinetic ballooning modes and MHD instabilities arising from peeling-ballooning modes, predicts the pressure profile at the onset of edge-localized modes (ELMs), and yields to lowest order a critical-βN like behavior for the pedestal: p∝Bt×Bp ( ∝Bt^2 for fixed edge q). C-Mod routinely accesses edge plasma pressure in excess of 30 kPa, often by using a high-density (ne>3×10^20 m^-3) approach to high confinement, taking advantage of a regime known as enhanced D-alpha (EDA) H-mode. In the EDA H-mode, plasma transport regulates both the pedestal profiles and the core impurity content, thus holding the pedestal stationary at just below the peeling-ballooning stability boundary. This stationary ELM-suppressed regime has approached the maximum pedestal predicted by EPED at these densities: 60 kPa. This in turn gives rise to volume-averaged core plasma pressure in excess of 0.2MPa, a world record value for a magnetic fusion device. Another approach to achieving high pressure utilizes a pedestal limited by current-driven modes at low collisionality, in which pressure increases with density and which allows access to a higher EPED solution, termed “super-H”. C-Mod experiments at reduced density (ne<2×10^20 m^-3) and strong plasma shaping (δ>0.5) accessed this regime, producing pedestals with pressures up to 80kPa (approximately 90% of the ITER target) and temperatures of nearly 2 keV. In a number of these hot H-modes, we observe strong edge instabilities at low toroidal mode number (n=1) when pedestal pressure approaches predicted values from EPED, showing that current-driven MHD modes can serve as a limit on the pedestal in a metal-walled tokamak at high pressure and low collisionality.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First results with a microcavity plasma panel detector

A new type of gaseous micropattern particle detector based on a closed-cell microcavity plasma panel sensor is reported. The first device was fabricated with 1 x 1 x 2 mm cells. It has shown very clean signals of 0.6-2.5 V amplitude, fast rise time of approximately 2 ns and FWHM of about 2 ns with very uniform signal shapes across all pixels. From initial measurements with beta particles from a radioactive source, a maximum pixel efficiency greater than 95% is calculated, for operation of the detector over a 100 V wide span of high voltages (HV). Over this same HV range, the background rate per pixel was measured to be 3-4 orders of magnitude lower than the rate with which the cell was illuminated by the beta source. Pixel-to-pixel count rate uniformity is within 3% and stable within 3% for many days. The time resolution is 2.4 ns, and a very low cell-to-cell crosstalk has been measured between cells separated by 2 mm. (C) 2014 Elsevier B.V. All rights reserved.

Ball, Robert↗