Long term temporal variations of the hard X-ray flux from the Centaurus region

The X-ray telescope aboard the third Orbiting Solar Observatory (OSO-3) observed the Centaurus region daily from 1967 October to 1968 February, and also for five days in 1968 June. A stable minimum flux of 0.33 + or - 0.03 photons (sq cm sec)/1 between 7.7 and 38 keV from a source around l = 305 deg is derived. Several single days show enhanced fluxes, and two extensive flaring episodes, one with a soft and the other a very hard spectrum, lasting at least ten days.

Schwartz, D. A.↗

Constraining Anisotropic Lorentz Violation via the Spectral-lag Transition of GRB 160625B

Violations of Lorentz invariance can lead to an energy-dependent vacuum dispersion of light, which results in arrival-time differences of photons with different energies arising from a given transient source. In this work, direction-dependent dispersion constraints are obtained on nonbirefringent Lorentz-violating effects using the observed spectral lags of the gamma-ray burst GRB 160625B. This burst has unusually large high-energy photon statistics, so we can obtain constraints from the true spectral time lags of bunches of high-energy photons rather than from the rough time lag of a single highest-energy photon. Also, GRB 160625B is the only burst to date having a well-defined transition from positive lags to negative lags, providing a unique opportunity to distinguish Lorentz-violating effects from any source-intrinsic time lag in the emission of photons of different energy bands. Our results place comparatively robust two-sided constraints on a variety of isotropic and anisotropic coefficients for Lorentz violation, including the first bounds on Lorentz-violating effects from operators of mass dimension 10 in the photon sector.

79 ASTRONOMY AND ASTROPHYSICS↗

An equivalent circuit model and power calculations for the APS SPX crab cavities

An equivalent parallel resistor-inductor-capacitor (RLC) circuit with beam loading for a polarized TM110 dipole-mode cavity is developed and minimum radio-frequency (rf) generator requirements are calculated for the Advanced Photon Source (APS) short-pulse x-ray (SPX) superconducting rf (SRF) crab cavities. A beam-loaded circuit model for polarized TM110 mode crab cavities was derived. The single-cavity minimum steady-state required generator power has been determined for the APS SPX crab cavities for a storage ring current of 200mA DC current as a function of external Q for various vertical offsets including beam tilt and uncontrollable detuning. Calculations to aid machine protection considerations were given.

43 PARTICLE ACCELERATORS↗

Using Rose’s metal alloy as a pinhole collimator material in preclinical small-animal imaging: A Monte Carlo evaluation

Purpose: Pinhole collimation is the most common method of high-resolution preclinical single photon emission computed tomography imaging. The collimators are usually constructed from dense materials with high atomic numbers, such as gold and platinum, which are expensive and not always flexible in the fabrication step. In this work, the authors have investigated the properties of a fusible alloy called Rose’s metal and its potential in pinhole preclinical imaging. When compared to current standard pinhole materials such as gold and platinum, Rose’s metal has a lower density and a relatively low effective atomic number. However, it is inexpensive, has a low melting point, and does not contract when solidifying. Once cast, the piece can be machined with high precision. The aim of this study was to evaluate the imaging properties for Rose’s metal and compare them with those of standard materials. Methods: After validating their Monte Carlo code by comparing its results with published data and the results from analytical calculations, they investigated different pinhole geometries by varying the collimator material, acceptance angle, aperture diameter, and photon incident angle. The penetration-to-scatter and penetration-to-total component ratios, sensitivity, and the spatial resolution were determined for gold, tungsten, and Rose’s metal for two radionuclides, {sup 99}Tc{sup m} and {sup 125}I. Results: The Rose’s metal pinhole-imaging simulations show higher penetration/total and scatter/total ratios. For example, the penetration/total is 50% for gold and 75% for Rose’s metal when simulating {sup 99}Tc{sup m} with a 0.3 mm aperture diameter and a 60° acceptance angle. However, the degradation in spatial resolution remained below 10% relative to the spatial resolution for gold for acceptance angles below 40° and aperture diameters larger than 0.5 mm. Conclusions: Extra penetration and scatter associated with Rose’s metal contribute to degradation in the spatial resolution, but this degradation is not always substantial. The most important factor besides the collimator material was the acceptance angle. This should be kept to a minimum to prevent unnecessary scatter and penetration. For {sup 125}I, the difference in spatial resolution between gold and Rose’s metal is very small, 2.2% in the worst-case scenario. Based on these results, the authors conclude that Rose’s metal is an alternative to standard materials not only for low-energy photon imaging but also for medium-energy applications that require low-cost, flexible pinhole configurations and designs, and that can tolerate a degraded spatial resolution.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-I-06: A Dose Calculation Algorithm for KV Diagnostic Imaging Beams by Empirical Modeling

Purpose: To develop accurate three-dimensional (3D) empirical dose calculation model for kV diagnostic beams for different radiographic and CT imaging techniques. Methods: Dose was modeled using photon attenuation measured using depth dose (DD), scatter radiation of the source and medium, and off-axis ratio (OAR) profiles. Measurements were performed using single-diode in water and a diode-array detector (MapCHECK2) with kV on-board imagers (OBI) integrated with Varian TrueBeam and Trilogy linacs. The dose parameters were measured for three energies: 80, 100, and 125 kVp with and without bowtie filters using field sizes 1×1–40×40 cm2 and depths 0–20 cm in water tank. Results: The measured DD decreased with depth in water because of photon attenuation, while it increased with field size due to increased scatter radiation from medium. DD curves varied with energy and filters where they increased with higher energies and beam hardening from half-fan and full-fan bowtie filters. Scatter radiation factors increased with field sizes and higher energies. The OAR was with 3% for beam profiles within the flat dose regions. The heal effect of this kV OBI system was within 6% from the central axis value at different depths. The presence of bowtie filters attenuated measured dose off-axis by as much as 80% at the edges of large beams. The model dose predictions were verified with measured doses using single point diode and ionization chamber or two-dimensional diode-array detectors inserted in solid water phantoms. Conclusion: This empirical model enables fast and accurate 3D dose calculation in water within 5% in regions with near charge-particle equilibrium conditions outside buildup region and penumbra. It considers accurately scatter radiation contribution in water which is superior to air-kerma or CTDI dose measurements used usually in dose calculation for diagnostic imaging beams. Considering heterogeneity corrections in this model will enable patient specific dose calculation.

60 APPLIED LIFE SCIENCES↗

Environmental research at the Advanced Photon Source.

Because of the importance of probing molecular-scale chemical and physical structure of environmental samples in their natural and often hydrated state, synchrotron radiation has been a powerful tool for environmental scientists for decades. Thus, the crucial role that a highly coherent and high-brightness hard X-ray source such as the Advance Photon Source (APS) can play in addressing many of the outstanding questions in molecular environmental science (MES) was recognized even before 'first light' at the facility. No single synchrotron-based technique or experimental approach can adequately address the tremendous temporal and spatial heterogeneities of the chemistry, physics, and biology of natural environmental samples. Thus, it is common at the APS that multiple X-ray techniques and experimental systems are employed to investigate environmental samples, often chosen for their ability to focus on solute species, plants, microbes, organics, interfacial species, or solids.

43 PARTICLE ACCELERATORS↗

A split-step method to include electron–electron collisions via Monte Carlo in multiple rate equation simulations

A split-step numerical method for calculating ultrafast free-electron dynamics in dielectrics is introduced. The two split steps, independently programmed in C++11 and FORTRAN 2003, are interfaced via the presented open source wrapper. The first step solves a deterministic extended multi-rate equation for the ionization, electron–phonon collisions, and single photon absorption by free-carriers. The second step is stochastic and models electron–electron collisions using Monte-Carlo techniques. This combination of deterministic and stochastic approaches is a unique and efficient method of calculating the nonlinear dynamics of 3D materials exposed to high intensity ultrashort pulses. Results from simulations solving the proposed model demonstrate how electron–electron scattering relaxes the non-equilibrium electron distribution on the femtosecond time scale.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dirhodium(II,II) Complexes as Panchromatic Single-Molecule Photocatalysts for Hydrogen Evolution

The growing global energy demand and climate change have prompted a shift from carbon-based fuels to sustainable energy sources. Hydrogen production by harnessing solar energy and using abundant proton sources represents an attractive approach to addressing this crisis. Single-molecule single-chromophore photocatalysts, capable of both absorbing the incident photon and catalyzing the chemical transformation, are able to circumvent energy losses present in multicomponent systems that require a photosensitizer and a catalyst, often employing additional redox relay molecules. Here, the series of complexes derived from cis-[Rh 2 (μ-DPhF) 2 (μ-bncn) 2 ] 2+ (1; DPhF = N,N′-diphenylformamidinate, bncn = benzo[c]cinnoline) discussed in this Account presents robust and air-stable single-molecule photocatalysts with panchromatic absorption from the ultraviolet spectral region to the near-infrared (NIR), with high turnover frequencies of ∼20 to 30 h –1 under red light irradiation. For comparison, other single-molecule hydrogen-evolving photocatalysts reported to date exhibit low photocatalytic efficiency, are not operable in the visible or NIR regions, and are unstable under an ambient atmosphere.

Absorption↗

HiSPoD : a program for high-speed polychromatic X-ray diffraction experiments and data analysis on polycrystalline samples

Here, a high-speed X-ray diffraction technique was recently developed at the 32-ID-B beamline of the Advanced Photon Source for studying highly dynamic, yet non-repeatable and irreversible, materials processes. In experiments, the microstructure evolution in a single material event is probed by recording a series of diffraction patterns with extremely short exposure time and high frame rate. Owing to the limited flux in a short pulse and the polychromatic nature of the incident X-rays, analysis of the diffraction data is challenging. Here, HiSPoD , a stand-alone Matlab-based software for analyzing the polychromatic X-ray diffraction data from polycrystalline samples, is described. With HiSPoD , researchers are able to perform diffraction peak indexing, extraction of one-dimensional intensity profiles by integrating a two-dimensional diffraction pattern, and, more importantly, quantitative numerical simulations to obtain precise sample structure information.

36 MATERIALS SCIENCE↗

SU-E-T-667: Radiosensitization Due to Gold Nanoparticles: A Monte Carlo Cellular Dosimetry Investigation of An Expansive Parameter Space

Purpose: To investigate dose enhancement to cellular compartments following gold nanoparticle (GNP) uptake in tissue, varying cell and tissue morphology, intra and extracellular GNP distribution, and source energy using Monte Carlo (MC) simulations. Methods: Models of single and multiple cells are developed for normal and cancerous tissues; cells (outer radii 5–10 µm) are modeled as concentric spheres comprising the nucleus (radii 2.5–7.5 µm) and cytoplasm. GNP distributions modeled include homogeneous distributions throughout the cytoplasm, variable numbers of GNP-containing endosomes within the cytoplasm, or distributed in a spherical shell about the nucleus. Gold concentrations range from 1 to 30 mg/g. Dose to nucleus and to cytoplasm for simulations including GNPs are compared to simulations without GNPs to compute Nuclear and Cytoplasm Dose Enhancement Factors (NDEF, CDEF). Photon source energies are between 20 keV and 1.25 MeV. Results: DEFs are highly sensitive to GNP intracellular distribution; for a 2.5 µm radius nucleus irradiated by a 30 keV source, NDEF varies from 1.2 for a single endosome containing all GNPs to 8.2 for GNPs distributed about the nucleus (7 mg/g). DEFs vary with cell dimensions and source energy: NDEFs vary from 2.5 (90 keV) to 8.2 (30 keV) for a 2.5 µm radius nucleus and from 1.1 (90 keV) to 1.3 (30 keV) for a 7.5 µm radius nucleus, both with GNPs in a spherical shell about the nucleus (7 mg/g). NDEF and CDEF are generally different within a single cell. For multicell models, the presence of gold within intervening tissues between source and target perturbs the fluence reaching cellular targets, resulting in DEF inhomogeneities within a population of irradiated cells. Conclusion: DEFs vary by an order of magnitude for different cell models, GNP distributions, and source energies, demonstrating the importance of detailed modelling for advancing GNP development for radiotherapy. Funding provided by the Natural Sciences and Engineering Council of Canada (NSERC), and the Canada Research Chairs Program (CRC)

61 RADIATION PROTECTION AND DOSIMETRY↗

LONG-TERM SPECTRAL VARIATIONS OF ULTRALUMINOUS X-RAY SOURCES IN THE INTERACTING GALAXY SYSTEMS M 51 AND NGC 4490/85

Variable ultraluminous X-ray sources (ULXs), which are considered to be black hole binaries (BHBs), are known to show state transitions similar to Galactic BHBs. However, the relation between the ULX states and the Galactic BHB states is still unclear, primarily due to the less well-understood behaviors of ULXs in contrast to the Galactic BHBs. Here, we report a statistical X-ray spectral study of 34 energy spectra from seven bright ULXs in the interacting galaxy systems M 51 and NGC 4490/85, using archive data from multiple Chandra and XMM-Newton observations spanning a few years. In order to compare them with Galactic BHB states, we applied representative spectral models of BHBs-a power-law (PL), a multi-color disk blackbody (MCD), and a slim-disk model-to all the ULX spectra. We found a hint of a bimodal structure in the luminosity distribution of the samples, suggesting that ULXs have two states that respectively have typical luminosities of (3-6)x 10{sup 39} and (1.5-3)x 10{sup 39} ergs s{sup -1}. Most spectra in the brighter state are explained by the MCD or the slim-disk model, whereas those in the fainter state are explained by the PL model. In particular, the slim-disk model successfully explains the observed spectral variations of NGC 4490/85 ULX-6 and ULX-8 by changes of the mass accretion rate to a black hole of an estimated mass of <40 M{sub sun}. From the best-fit model parameters of each state, we speculate that the brighter state in these two ULXs corresponds to the brightest state of Galactic BHBs, which is often called the 'apparently standard state'. The fainter state of the ULXs has a PL-shaped spectrum, but the photon index range is much wider than that seen in any single state of Galactic BHBs. We thus speculate that it is a state unique to ULXs. Some sources show much fainter and steeper spectra than the faint state, which we identified as yet another state.

79 ASTRONOMY AND ASTROPHYSICS↗

Nonclassical Light Sources Based on Selectively Positioned Deterministic Microlens Structures and (111) In(Ga)As Quantum Dots

The results of investigations of the optical characteristics of nonclassical light sources based on selectively positioned microlens structures and single (111) In(Ga)As quantum dots grown on a (111) BGaAs substrate are presented. The single-photon nature of the radiation is confirmed by measuring and analyzing second-order correlation functions g{sup (2)}(τ); g{sup (2)}(0) = 0.07. The fine structure of the exciton states of (111) In(Ga)As quantum dots is investigated. It is shown that, in the energy range of 1.320–1.345 eV, the splitting of exciton states is comparable to the natural width of the exciton lines, which is of interest for developing photon-pair emitters based on them.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Neutron damage and recovery studies of SiPMs

SiPM lost its performance characteristics when exposed to hig dose of neutrons. However, the distinct hallmark of SiPMs, low dark count and excellent photon-number-resolving capability, can be recovered by thermal annealing. Several SiPMs from different vendors are characterized before and after exposure of up to 1010 neutron/cm2 dosage using a 14 MeV neutron generation source. Collectively, we established that the typical orders of magnitude increase in dark current upon neutron irradiation can be lowered substantially after processing them with a thermal annealing procedure, and single-photon detection are to some extent recovered. Moreover, we found no significant difference on neutron damaged behavior when SiPMs are irradiated at room or liquid nitrogen temperatures suggesting that there is no evidence of radiation hardening when SiPMs are operated in cryogenic temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conceptual design of front ends for the advanced photon source multi-bend achromats upgrade

The proposed Advanced Photon Source (APS) upgrade from a double-bend achromats (DBA) to multi-bend achromats (MBA) lattice with ring energy change from 7 GeV to 6 GeV and beam current from 100 mA to 200 mA poses new challenges for front ends. All front ends must be upgraded to fulfill the following requirements: 1) handle the high heat load from two insertion devices in either inline or canted configuration, 2) include a clearing magnet in the front end to deflect and dump any electrons in case the electrons escape from the storage ring during swap-out injection with the safety shutters open, 3) incorporate the next generation x-ray beam position monitors (XBPMs) into the front end to meet the new stringent beam stability requirements. This paper presents the evaluation of the existing APS front ends and standardizes the insertion device (ID) front ends into two types: one for the single beam and one for the canted beams. The conceptual design of high heat load front end (HHLFE) and canted undulator front end (CUFE) for APS MBA upgrade is presented.

43 PARTICLE ACCELERATORS↗

Third-order correlation function and ghost imaging of chaotic thermal light in the photon counting regime

In a near-field three-photon correlation measurement, we observed the third-order temporal and spatial correlation functions of chaotic thermal light in the single-photon counting regime. In the study, we found that the probability of jointly detecting three randomly radiated photons from a chaotic thermal source by three individual detectors is 6 times greater if the photodetection events fall in the coherence time and coherence area of the radiation field than if they do not. From the viewpoint of quantum mechanics, the observed phenomenon is the result of three-photon interference. By making use of this property, we measured the three-photon thermal light lensless ghost image of a double spot and achieved higher visibility compared with the two-photon thermal light ghost image.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Correction of complex nonlinear signal response from a pixel array detector

The pulsed free-electron laser light sources represent a new challenge to photon area detectors due to the intrinsic spontaneous X-ray photon generation process that makes single-pulse detection necessary. Intensity fluctuations up to 100% between individual pulses lead to high linearity requirements in order to distinguish small signal changes. In real detectors, signal distortions as a function of the intensity distribution on the entire detector can occur. Here a robust method to correct this nonlinear response in an area detector is presented for the case of exposures to similar signals. The method is tested for the case of diffuse scattering from liquids where relevant sub-1% signal changes appear on the same order as artifacts induced by the detector electronics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for GeV and X-Ray Flares Associated with the IceCube Track-like Neutrinos

Dozens of high-energy neutrinos have been detected by the IceCube neutrino telescope, but no clear association with any classes of astrophysical sources has been identified so far. Recently, Kadler et al. reported that a PeV cascade-like neutrino event occurred in positional and temporal coincidence with a giant gamma-ray flare of the blazar PKS B1424-418. Since IceCube track-like events have much better angular resolution, we here search for possible short-term gamma-ray flares that are associated with the IceCube track-like events with Fermi Large Area Telescope (LAT) observations. Among them, three track-like neutrino events occur within the field of view of Fermi -LAT at the time of the detection, so searching for the prompt gamma-ray emission associated with neutrinos is possible. Assuming a point source origin and a single power-law spectrum for the possible gamma-ray sources associated with neutrinos, a likelihood analysis of 0.2–100 GeV photons observed by Fermi -LAT on the timescales of ∼12 hr and one year are performed, and for the three special neutrinos, the analyses are also performed on the timescales of thousands of seconds before and after the neutrino detection. No significant GeV excesses over the background are found and upper limit fluxes at the 95% confidence level are obtained for different timescales. We also search for possible the Swift hard X-ray transient sources associated with the IceCube track-like neutrino events, but the search also yields null results. We discuss the implication of the non-detection of gamma-ray flares for the constraints on the neutrino source density.

79 ASTRONOMY AND ASTROPHYSICS↗

The megasecond Chandra X-ray visionary project observation of NGC 3115. II. Properties of point sources

We carried out an in-depth study of low-mass X-ray binaries (LMXBs) detected in the nearby lenticular galaxy NGC 3115 using the Megasecond Chandra X-ray Visionary Project observation (total exposure time 1.1 Ms). In total we found 136 candidate LMXBs in the field and 49 in globular clusters (GCs) above 2σ detection, with 0.3–8 keV luminosity L{sub X} ∼ 10{sup 36}–10{sup 39} erg s{sup −1}. Other than 13 transient candidates, the sources overall have less long-term variability at higher luminosity, at least at L{sub X}≳2×10{sup 37} erg s{sup −1}. In order to identify the nature and spectral state of our sources, we compared their collective spectral properties based on single-component models (a simple power law or a multicolor disk) with the spectral evolution seen in representative Galactic LMXBs. We found that in the L{sub X} versus photon index Γ{sub PL} and L{sub X} versus disk temperature kT{sub MCD} plots, most of our sources fall on a narrow track in which the spectral shape hardens with increasing luminosity below L{sub X}∼7×10{sup 37} erg s{sup −1}, but is relatively constant (Γ{sub PL}∼1.5 or kT{sub MCD}∼1.5 keV) above this luminosity, which is similar to the spectral evolution of Galactic neutron star (NS) LMXBs in the soft state in the Chandra bandpass. Therefore, we identified the track as the NS LMXB soft-state track and suggested sources with L{sub X}≲7×10{sup 37} erg s{sup −1} as atolls in the soft state and those with L{sub X}≳7×10{sup 37} erg s{sup −1} as Z sources. Ten other sources (five are transients) displayed significantly softer spectra and are probably black hole X-ray binaries in the thermal state. One of them (persistent) is in a metal-poor GC.