Search NASA⌕ Search

SEARCH · Search NASA

Results for “small lasers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Downhole Elemental Analysis with LIBS

In this paper we discuss a novel instrument, currently under development at Honeybee Robotics with SBIR funding from NASA. The device is designed to characterize elemental composition as a function of depth in non-terrestrial geological formations. The instrument consists of a miniaturized laser-induced breakdown spectrometer (LIBS) analyzer integrated in a 2" diameter drill string. While the drill provides subsurface access, the LIBS analyzer provides information on the elemental composition of the borehole wall. This instrument has a variety of space applications ranging from exploration of the Moon for which it was originally designed, to Mars, as well as a variety of terrestrial applications. Subsurface analysis is usually performed by sample acquisition through a drill or excavator, followed by sample preparation and subsequent sample presentation to an instrument or suite of instruments. An alternative approach consisting in bringing a miniaturized version of the instrument to the sample has many advantages over the traditional methodology, as it allows faster response, reduced probability of cross-contamination and a simplification in the sampling mechanisms. LIBS functions by focusing a high energy laser on a material inducing a plasma consisting of a small fraction of the material under analysis. Optical emission from the plasma, analyzed by a spectrometer, can be used to determine elemental composition. A triangulation sensor located in the sensor head determines the distance of the sensor from the borehole wall. An actuator modifies the position of the sensor accordingly, in order to compensate for changes due to the profile of the borehole walls. This is necessary because LIBS measurements are negatively affected by changes in the relative position of the focus of the laser with respect to the position of the sample (commonly referred to as the "lens to sample distance"). Profiling the borehole is done by adjusting the position of the sensor with a vertical stage; a second actuator at the top of the downhole probe allows radial scanning of the borehole. Analysis of iron and titanium in lunar simulant with LIBS was performed in air using the method of standard addition. The results for lunar simulant NU-LHT-2M show a value for the concentration of iron ranging between 2.29% and 3.05% depending on the atomic line selected. The accepted value for the sample analyzed is 2.83%, showing the capability for the system in development to provide qualitative and semi-quantitative analysis in real-time.

Moreschini, Paolo↗

Thermal compensator for closed-cycle helium refrigerator

The wave length of an infrared, semiconductor laser diode having an output frequency that is dependent on the diode temperature is maintained substantially constant by maintaining the diode temperature constant. The diode is carried by a cold tip of a closed cycle helium refrigerator. The refrigerator has a tendency to cause the temperature of the cold tip to oscillate. A heater diode and a sensor diode are placed on a thermal heat sink that is the only highly conductive thermal path between the laser diode and the cold tip. The heat sink has a small volume and low thermal capacitance so that the sensing diode is at substantially the same temperature as the heater diode and substantially no thermal lag exists between them. The sensor diode is connected in a negative feedback circuit with the heater diode so that the tendency of the laser diode to thermally oscillate is virtually eliminated.

Jennings, D. E.↗

A comparative study of multimodal data fusion strategies for planetary spectroscopy

Integrating heterogeneous data sources can improve scientific inference when different modalities capture complementary information, but doing so is challenging in high-dimensional, small-sample settings. In spectroscopy for planetary exploration, Laser-Induced Breakdown Spectroscopy (LIBS), Raman Spectroscopy (Raman), Visible Infrared Spectroscopy (VISIR), and Mid-Infrared Spectroscopy (MIR) each examine different aspects of composition and mineralogy, raising fundamental questions about when and how data fusion improves predictive performance. Using a Mars-relevant set of geologic standards with measurements from all four modalities, we present a rigorous systematic evaluation of four data fusion strategies: low-level (data) fusion, mid-level (feature) fusion, high-level (decision) fusion, and residual-boosting (sequential) fusion. We assess performance in predicting oxide composition via nested cross-validation and corrected significance testing to evaluate whether data fusion improves upon single-modality baselines. We show that data fusion does not uniformly improve accuracy, and that observed gains are modest, oxide-dependent, and sensitive to modality and model structure. To move beyond aggregate accuracy metrics, we use model coefficients, permutation importance, and residual gain analysis to examine how the fusion models weight individual modalities and to identify patterns of apparent complementarity or redundancy. Though focused on spectroscopy for planetary exploration, our framework for data fusion evaluation and interpretation extends to other scientific domains with heterogeneous and scarce data and provides a principled approach evaluating data fusion strategies, interpreting modality contributions, and understanding tradeoffs among data fusion strategies.

97 MATHEMATICS AND COMPUTING↗

Overcoming Variability: A Reproducible Approach to SERS Detection of Nanodiamonds

Detonation nanodiamonds (DNDs) are formed at specific pressures and temperatures during explosions. Different explosives produce varied yields of DNDs within their detonation soot, with Composition B producing the highest yield. Raman spectroscopy (RS) is often used for the characterization of sp 2 - and sp 3 -hybridized carbon allotropes in carbonaceous materials because of distinct disorder and graphitic bands. Bulk diamond also gives a distinct Raman peak at 1332 cm –1 . Furthermore, as bulk diamond decreases in size to nanometer-sized species, the peak red-shifts and broadens, becoming increasingly difficult to detect with RS using visible excitations. Therefore, surface-enhanced Raman spectroscopy (SERS) was used to enhance the diamond peak of DNDs, enabling better detection and faster examination of DNDs within detonation soot. Previous literature of the SERS of DNDs delivered inconsistent results in spectral signatures and SERS substrates. Herein, refining of the methodology for the acquisition of SERS spectra of DNDs was achieved. Before any SERS experiments, the DNDs were first characterized with normal Raman (NR) and scanning electron microscopy. Two routes for SERS enhancement were evaluated: colloidal noble metal nanoparticles and evaporated silver films. Silver films produced the best signal enhancement of DNDs with the best signal-to-noise and peak enhancements observed at 20–30 nm thick silver films at 5% (∼300 μW) laser power. Consistent, reproducible SERS spectra were acquired of small aggregates of DNDs down to ∼500 nm. NR and SERS mapping analysis of DNDs before and after evaporation of silver films revealed the improvements in the detection capabilities of SERS compared with NR.

Carbon↗

Converting existing optical detectors into fast x-ray detectors

Here, the very short burn time and small size of burning plasmas created at advanced laser-fusion facilities will require high-spatial-resolution imaging diagnostics with fast time resolution. These instruments will need to function in an environment of extremely large neutron fluxes that will cause conventional diagnostics to fail because of radiation damage and induced background levels. One solution to this challenge is to perform an ultrafast conversion of the x-ray signals into the optical regime before the neutrons are able to reach the detector and then to relay image the signal out of the chamber and into a shielded bunker, protected from the effects of these neutrons. With this goal in mind, the OMEGA laser was used to demonstrate high-temporal-resolution x-ray imaging by using an x-ray snout to image an imploding backlighter capsule onto a semiconductor. The semiconductor was simultaneously probed with the existing velocity interferometry system for any surface reflector (VISAR) diagnostic, which uses an optical streak camera and provided a one-dimensional image of the phase in the semiconductor as a function of time. The phase induced in the semiconductor was linearly proportional to the x-ray emission from the backlighter capsule. This approach would then allow a sacrificial semiconductor to be attached at the end of an optical train with the VISAR and optical streak camera placed in a shielded bunker to operate in a high neutron environment and obtain time-dependent one-dimensional x-ray images or time-dependent x-ray spectra from a burning plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Boiling and cavitation caused by transient heat transfer in superfluid helium-4

Superfluid helium-4 (He II) has been widely utilized as a coolant in various scientific and engineering applications due to its superior heat transfer capability. An important parameter required in the design of many He II based cooling systems is the peak heat flux $q^*$, which refers to the threshold heat flux above which boiling spontaneously occurs in He II. Past experimental and numerical studies showed that $q^*$ increases when the heating time $t_h$ is reduced, which leads to an intuitive expectation that very high $q^*$ may be achievable at sufficiently small $t_h$. Knowledge on how $q^*$ actually behaves at small $t_h$ is important for applications such as laser ablation in He II. Furthermore we present a numerical study on the evolution of the thermodynamic state of the He II in front of a planar heater by solving the He II two-fluid equations of motion. For an applied heat flux, we determine the heating time beyond which the He II near the heater transits to the vapor phase. As such, a curve correlating $q^*$ and $t_h$ can be obtained, which nicely reproduces some relevant experimental data. Surprisingly, we find that there exists a critical peak heat flux $q^*_c$, above which boiling occurs nearly instantaneously regardless of $t_h$. We reveal that the boiling in this regime is essentially cavitation caused by the combined effects of the first-sound and the second-sound waves in He II. Based on this physical picture, an analytical model for $q^*_c$ is developed, which reproduces the simulated $q^*_c$ values at various He II bath temperatures and hydrostatic head pressures. This work represents a major progress in our understanding of transient heat transfer in He II.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Overview of the LANL Multi-Probe Radiography Project [Slides]

Future radiographic facilities for the U.S. defense program will be required to provide more information as simulation codes improve in both physics’ fidelity and resolution. A possible approach is to use more types of probe beams in addition to, or instead of X-rays, generated by 20-MeV electron accelerators from a small number of directions. High power short-pulse laser systems can generate beams of protons, neutrons and electrons, as well as X-rays. The cost of these systems is falling rapidly. So, it can be imagined that deploying multiple short-pulse lasers along with other, more traditional probes, will become feasible. In this project, we are following three paths to determine if such an approach will succeed for cm-scale objects. The first is an experimental one to determine if the presence of multiple short-pulse probes cause interference with each other, especially while radiographing dynamic objects. The second leg of this project is to determine if having multiple types of probes really does give more information on composition. Finally, an overall assessment of the viability of this approach will be made. Examples from recent experiments at the Omega EP laser will be presented. The initial approach to evaluating radiographs with multiple probes using the Bayesian Inference Engine (BIE) also will be given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Opportunities in Pulsed Magnetic Fusion Energy

Fusion is a potentially transformational energy technology, which promises limitless clean energy. Yet, it requires continued scientific and technological development to realize its potential. The conditions necessary for fusion energy gain in terms of the product of plasma pressure P and confinement time $\tau$ have been known for many decades. An underappreciated fact is that pulsed magnetic fusion has demonstrated P $\tau$ performance on par with laser-driven ICF and tokamaks despite receiving only a small fraction of investment relative to those concepts. In light of this demonstrated performance, well-established scaling relations, and opportunities for further innovations, here we advocate for pulsed magnetic fusion as the most attractive path towards commercialization of fusion energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Wideband, high efficiency optical modulator requires less than 10 watts drive power

Wideband optical modulation system operates with less than 10-watts drive power. It consists of an optical modulator and transistorized driver that combines small cross-section potassium dideuterium phosphate crystals with laser beam-condensing optics. Optical modulation systems may serve importantly in future space wideband communication systems.

Becknell, W. E.↗

Optical diagnostics of gas-dynamic flows using advanced laser measurement techniques

Using laser-induced fluorescence to probe nitrogen flows seeded with small amounts of nitric oxide, simultaneous measurements of all three thermodynamic scalar quantities temperature, density, and pressure, were demonstrated in a supersonic turbulent boundary layer. Instrumental uncertainty is 1% for temperature and 2% for density and pressure, making the techniques suitable for measurements of turbulent fluctuations. This technology is currently being transferred to an experimental program designed to use these optical techniques in conjunction with traditional methods to make measurements in turbulent flowfields that were not possible before. A detailed descritpion of the research progress and pertinent results are presented.

Gross, K. P.↗

Eye-Safe Lidar

Laser infrared radar (lidar) undergoing development harmless to human eyes, consists almost entirely of solid-state components, and offers high range resolution. Operates at wavelength of about 2 micrometers. If radiation from such device strikes eye, almost completely absorbed by cornea without causing damage, even if aimed directly at eye. Continuous-wave light from laser oscillator amplified and modulated for transmission from telescope. Small portion of output of oscillator fed to single-mode fiber coupler, where mixed with return pulses. Intended for remote Doppler measurements of winds and differential-absorption measurements of concentrations of gases in atmosphere.

Byer, Robert L.↗

Design of a high-gain laser diode-array pumped Nd:YAG Alternating Precessive Slab Amplifier (APS-Amplifier)

In the design of space qualifiable laser systems for ranging and altimetry, such as NASA's Geodynamic Laser Ranging System (GLRS), the transmitter must be kept small, powerful yet efficient, and must consist of as few components as possible. A novel preamplifier design is examined which requires no external beam steering optics, yielding a compact component with simple alignment procedures. The gains achieved are comparable to multipass zigzag amplifiers using two or more sets of external optics for extra passes through the amplifying medium.

Coyle, D. Barry↗

Effects of beam focusing on the efficiency of planar waveguide grating couplers

Results of a theoretical and experimental study into the variation of coupling efficiency with a grating angle are presented for various beam focusing conditions for an integrated optical grating coupler. The study shows that the acceptance angle of the grating coupler can be broadened within a relatively large range and with a relatively small loss of coupling efficiency, by focusing the incident laser beam.

Li, Lifeng↗

Lidar receivers for picosecond remote sensing

The lidars of picosecond resolution are an attractive tool for remote probing of some highly dynamic objects like sea subsurface waters, small-scale turbulences in the atmosphere, etc. The picosecond lasers are suitable illuminating sources, but the main restrictions are due to the lack of proper receiving methods, combining the both high temporal and amplitude resolution, good sensitivity, short integration time, and wide dynamic range. The methods for short pulse measurements are not suitable for picosecond lidars, operating at low level, with highly dynamic signals. The streak-cameras are of high cost, lower sensitivity, and lower dynamic range (approximately 10(exp 3)). Because of the background, the single quantum regime in photomultipliers (PMT) is ineffective. The sampling of highly dynamic optical signals with resolution less than or equal to 1ns is a serious problem, limiting the application of the high speed PMT-MCP (microchannel plate) in the picosecond lidar systems. The goal of this work is to describe the use of a new photodetection technique which combines the picosecond resolution with the high amplitude resolution, dynamic range, and sensitivity.

Stoyanov, D. V.↗

Design of a high-gain laser diode-array pumped Nd:YAG alternating precessive slab amplifier (APS amplifier)

In the design of space-qualifiable laser systems for ranging and altimetry, such as NASA's Geodynamic Laser Ranging System (GLRS), the transmitter must be kept small, powerful yet efficient, and must consist of as few components as possible. A novel preamplifier design is examined which requires no external beam steering optics, yielding a compact component with simple alignment procedures. The gains achieved are comparable to multipass zigzag amplifiers using two or more sets of external optics for extra passes through the amplifying medium.

Coyle, D. B.↗

Processing and Synthesis of Pre-Biotic Chemicals in Hypervelocity Impacts

Hypervelocity impacts (HVIs) may have played a significant role in establishing the initial organic inventory for pre-biotic chemistry on the Earth and other planetary bodies. In addition to the delivery of organic compounds intact to planetary surfaces, generally at velocities below approx.20 km/s, HVIs also enable synthesis of new molecules. The cooling post-impact plasma plumes of HVIs in the interstellar medium (ISM), the protosolar nebula (PSN), and the early solar system comprise pervasive conditions for organic synthesis. Such plasma synthesis (PS) can operate over many length scales (from nm-scale dust to planets) and energy scales (from molecular rearrangement to atomization and recondensation). HVI experiments with the flexibility to probe the highest velocities and distinguish synthetic routes are a high priority to understand the relevance of PS to exobiology. We describe here recent studies of PS at small spatial scales and extremely high velocities with pulsed laser ablation (PLA). PLA can simulate the extreme plasma conditions generated in impacts of dust particles at speeds of up to 100 km/s or more. When applied to carbonaceous solids, new and pre-biotically relevant molecular species are formed with high efficiency [1,2].

Brickerhoff, W. B.↗

Zeeman Tuning Rates in the v3 Band of NO2

Zeeman spectra of the v3 fundamental (at approximately 1620 c/m) of nitrogen dioxide (14N02) have been recorded with magnetic fields of approximately 500 Gauss using a FTS (at the Kitt Peak National Observatory), as well as a tunable diode laser. At low magnetic fields the Zeeman effect is small compared to the spin-rotation interaction, and the Zeeman tuning rates are expected to be linear with magnetic field. Measured tuning rates of the Q-branch (KA = 2 - 9, N = 2 - 6) sigma transitions are compared to those expected for 2Sigma transitions in low magnetic fields, 2mu ogB/(2N+l). These measurements are required in the data analysis of an ultra-sensitive (pptv) in situ detector based on magnetic-rotation spectroscopy.

Mahon, C. H.↗