Search NASA⌕ Search

SEARCH · Search NASA

Results for “software based”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Comparison of Hybrid K-Edge Densitometer (HKED) Performance Operating with the Canberra Lynx MCA and the Canberra ICB-NIM Electronics

From the 1991 until 2008 the Canberra Hybrid K-Edge Densitometer systems were provided with ICB-NIM (Integrated Control Bus – Nuclear Instrument Module) acquisition electronics. Newer electronics modules, such as the Lynx, were not supported under the VMS based operating system. The LYNX module was provided as the standard acquisition electronics following the release of the Windows based CHKED software. This report compares the electronics dead-time, gain shifts, detector resolution and measurement performance of the HKED system operated with the two types of acquisition modules. The comparison was performed using measurements obtained with the ORNL HKED system. The original intent of this study was to take advantage of both the timing and energy outputs from the HPGE detector to acquire data with both sets of electronics in parallel. Although this approach has been applied successfully with other systems, in this case we found the timing output produced a significant amount of noise such that a comparison between the electronics would be invalid. So the comparative measurements were performed sequentially. The ICB-NIM data was acquired over the course of 12 months with 255 measurements while the LYNX data was acquired over a period of 10 months with 75 measurements. To simplify the comparison, all data used in this study was acquired using the Canberra CHKED (V1.0) software package. The performance analysis was based primarily on the peak locations, peak widths and concentration values reported by the CHKED software. The raw spectra from the XRF measurements were also examined to extract additional 109Cd peak location and width data for the hybrid measurements (the standard hybrid report template does not report these values).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Discovering methylated DNA motifs in bacterial nanopore sequencing data with MIJAMP

Abstract Bacterial DNA methylation is involved in diverse cellular functions, including modulation of gene expression, DNA repair, and restriction–modification systems for defense against viruses and other foreign DNA. Restriction systems hinder efforts to engineer organisms to produce fuels and chemicals from waste and renewable feedstocks by degrading DNA during transformation. Methylome analysis allows identification of motifs within a bacterial chromosome that may be targeted by native restriction enzymes. Further expression of the corresponding methyltransferases in Escherichia coli allows plasmid DNA to be protected from restriction in the target organism, thereby drastically enhancing transformation efficiency. Nanopore sequencing can detect methylated bases, but software is needed to transform modified base coordinates into methylated motifs. Here, we develop MIJAMP (MIJAMP Is Just A MethylBED Parser), a software package that was developed to discover methylated motifs from the output of ONT’s Modkit or other data in the methylBED format. MIJAMP employs a human-driven refinement strategy that empirically validates all motifs against genome-wide methylation data, thus eliminating incorrect motifs. MIJAMP also reports methylation data on specific, user-defined motifs. Using MIJAMP, we determined the methylated motifs both in a control strain (wild-type E. coli) and in Synecococcus sp. strain PCC7002, laying the foundation for improved transformation in this organism. MIJAMP is available at https://code.ornl.gov/alexander-public/mijamp/. One Sentence Summary: Here we describe software written to discover DNA methylation motifs from nanopore sequencing data.

59 BASIC BIOLOGICAL SCIENCES↗

An elastography method based on the scanning contact resonance of a piezoelectric cantilever

Purpose: Most tissues may become significantly stiffer than their normal states when there are lesions inside. The tissue's modulus can then act as an identification parameter for clinic diagnosis of tumors or fibrosis, which leads to elastography. This study introduces a novel elastography method that can be used for modulus imaging of superficial organs. Methods: This method is based on the scanning contact-resonance of a unimorph piezoelectric cantilever. The cantilever vibrates in its bending mode with the tip pressed tightly on the sample. The contact resonance frequency of the cantilever-sample system is tracked at each scanning point, from which the sample's modulus can be derived based on a beam dynamic model and a contact mechanics model. Scanning is performed by a three-dimensional motorized stage and the whole system is controlled by a homemade software program based on LabVIEW. Results: Testing onin vitro beef tissues indicates that the fat and the muscle can be easily distinguished using this system, and the accuracy of the modulus measurement can be comparable with that of nanoindentation. Imaging on homemade gelatin phantoms shows that the depth information of the abnormalities can be qualitatively obtained by varying the pressing force. The detection limit of this elastography method is specially examined both experimentally and numerically. Results show that it can detect the typical lesions in superficial organs with the depth of several centimeters. The lateral resolution of this elastography method/system is better than 0.5 mm, and could be further enhanced by using more scanning points. Conclusions: The proposed elastography system can be regarded as a sensitive palpation robot, which may be very promising in early diagnosis of tumors in superficial organs such as breast and thyroid.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automatic Commercial Permit Sets

Final report for Folsom Labs’ Solar Permit Generator project, which has successfully completed, resulting in the development and commercialization of a software toolkit within the cloud-based HelioScope software environment that enables solar engineers to automatically generate and manage draft documents for permit submission.

14 SOLAR ENERGY↗

Secure Software Central-The VOLTTRON Case

The SSC work arose from VOLTTRON’s PNNL campus deployment and resulted in a Threat Profile containing critical assets, prioritized threats, and controls for mitigating those threats. The Threat Profile outlines controls already in place, controls not yet in place, and recommendations for implementing controls. As a companion to the software, the Threat Profile shows due diligence in cybersecurity risk management in terms of security requirements, security recommendations, security budgeting, justification, and prioritization. This report describes the SSC offerings in general and the specific offerings applied to VOLTTRON.

97 MATHEMATICS AND COMPUTING↗

Rapidly Measuring Loop Footprints

Knowing a loop’s footprint — the unique data items it accesses — enables important locality and capacity analysis. Unfortunately, current methods for computing footprint cause integer factors of slowdown and are therefore difficult to use with realistic inputs. Current methods are slow because they are based on software tracing of load instructions and data addresses. We present an approach that combines lightweight measurements and static binary analysis. We use static analysis to reason about each load’s expected reuse. We then calculate the footprint for each loop using inference rules informed by measurements from common performance counters. We validate our method on benchmarks that vary access patterns (strided vs. unpredictable), reuse (varying and repeated accesses per element), and sparsity (all words in a cache line vs. some). For strided patterns, errors are within 1%; for unpredictable ones, errors are 5–10%. Our overheads are under 10%. A tool based on software tracing has an error of less than 1%, but either introduces at least 130× overhead or hangs.

Kilic, Ozgur O.↗

IDAC-Bio, A Software for Internal Dosimetry Based on the New ICRP Biokinetic Models and Specific Absorbed Fractions

Radiation dosimetry is central to virtually all radiation safety applications, optimization, and research. It relates to various individuals and population groups and to miscellaneous exposure situations—including planned, existing, and emergency situations. The International Commission on Radiological Protection (ICRP) has developed a new computational framework for internal dose estimations. Important components are more detailed and improved anatomical models and more realistic biokinetic models than before. The ICRP is currently producing new organ dose and effective dose coefficients for occupational intakes of radionuclides (OIR) and environmental intakes of radionuclides (EIR), which supersede the earlier dose coefficients in Publication 68 and the Publication 72 series, respectively. However, the ICRP only publishes dose coefficients for a single acute intake of a radionuclide and for an integration period of 50 years for intake by adults and to age 70 years for intakes by pre-adults. The new software, IDAC-Bio, performs committed absorbed dose and effective dose calculations for a selectable intake scenario, e.g., for a continuous intake or an intake during x hours per day and y days per week, and for any selected integration time. The software uses the primary data and models of the ICRP biokinetic models and numerically solves the biokinetic model and calculates the absorbed doses to organs and tissues in the ICRP reference human phantoms. The software calculates absorbed dose using the nuclear decay data in ICRP publication 107. IDAC-Bio is a further development and an important addition to the internal dosimetry program IDAC-Dose2.1. Here, the results generated by the software were validated against published ICRP dose coefficients. The potential of the software is illustrated by dose calculations for a nuclear power plant worker who had been exposed to varying levels of 60 Co and who had undergone repeated whole-body measurements, and for a hypothetical member of the public subject to future releases of 148 Gd from neutron spallation in tungsten at the European Spallation Source.

61 RADIATION PROTECTION AND DOSIMETRY↗

Agent-based forward analysis

We propose software agent-based "forward analysis" for efficient information retrieval in a network of sensing devices. In our approach, processing is pushed to the data at the edge of the network via intelligent software agents rather than pulling data to a central facility for processing. The agents are deployed with a specific query and perform varying levels of analysis of the data, communicating with each other and sending only relevant information back across the network. We demonstrate our concept in the context of face recognition using a wireless test bed comprised of PDA cell phones and laptops. We show that agent-based forward analysis can provide a significant increase in retrieval speed while decreasing bandwidth usage and information overload at the central facility. n

99 GENERAL AND MISCELLANEOUS↗

Optimizing legacy molecular dynamics software with directive-based offload

The directive-based programming models are one solution for exploiting many-core coprocessors to increase simulation rates in molecular dynamics. They offer the potential to reduce code complexity with offload models that can selectively target computations to run on the CPU, the coprocessor, or both. In our paper, we describe modifications to the LAMMPS molecular dynamics code to enable concurrent calculations on a CPU and coprocessor. We also demonstrate that standard molecular dynamics algorithms can run efficiently on both the CPU and an x86-based coprocessor using the same subroutines. As a consequence, we demonstrate that code optimizations for the coprocessor also result in speedups on the CPU; in extreme cases up to 4.7X. We provide results for LAMMAS benchmarks and for production molecular dynamics simulations using the Stampede hybrid supercomputer with both Intel (R) Xeon Phi (TM) coprocessors and NVIDIA GPUs: The optimizations presented have increased simulation rates by over 2X for organic molecules and over 7X for liquid crystals on Stampede. The optimizations are available as part of the "Intel package" supplied with LAMMPS. (C) 2015 Elsevier B.V. All rights reserved.

97 MATHEMATICS AND COMPUTING↗

Automating Embedded Analysis Capabilities and Managing Software Complexity in Multiphysics Simulation, Part I: Template-Based Generic Programming

An approach for incorporating embedded simulation and analysis capabilities in complex simulation codes through template-based generic programming is presented. This approach relies on templating and operator overloading within the C++ language to transform a given calculation into one that can compute a variety of additional quantities that are necessary for many state-of-the-art simulation and analysis algorithms. An approach for incorporating these ideas into complex simulation codes through general graph-based assembly is also presented. These ideas have been implemented within a set of packages in the Trilinos framework and are demonstrated on a simple problem from chemical engineering.

Pawlowski, Roger P.↗

DEVELOPING THE NATIONAL GEOTHERMAL DATA SYSTEM ADOPTION OF CKAN FOR DOMESTIC & INTERNATIONAL DATA DEPLOYMENT

The National Geothermal Data System (NGDS) De- sign and Testing Team is developing NGDS software currently referred to as the “NGDS Node-In-A-Box”. The software targets organizations or individuals who wish to host at least one of the following: • an online repository containing resources for the NGDS; • an online site for creating metadata to register re- sources with the NGDS • NDGS-conformant Web APIs that enable access to NGDS data (e.g., WMS, WFS, WCS); • NDGS-conformant Web APIs that support dis- covery of NGDS resources via catalog service (e.g. CSW) • a web site that supports discovery and under- standing of NGDS resources A number of different frameworks for development of this online application were reviewed. The NGDS Design and Testing Team determined to use CKAN (http://ckan.org/), because it provides the closest match between out of the box functionality and NGDS node-in-a-box requirements. To achieve the NGDS vision and goals, this software development project has been inititated to provide NGDS data consumers with a highly functional inter- face to access the system, and to ease the burden on data providers who wish to publish data in the sys- tem. It is important to note that this software package constitutes a reference implementation. The NGDS software is based on open standards, which means other server software can make resources available, and other client applications can utilize NGDS data. A number of international organizations have ex- pressed interest in the NGDS approach to data access. The CKAN node implementation can provide a sim- ple path for deploying this technology in other set- tings.

15 GEOTHERMAL ENERGY↗

CASM — A software package for first-principles based study of multicomponent crystalline solids

CASM is a software package that enables first-principles based studies of crystalline materials. It has been designed to treat coupled chemical, mechanical, vibrational, and magnetic degrees of freedom to determine ground state and finite temperature properties of crystals. The symmetry of the underlying parent crystal structure is used to enumerate perturbations of the parent crystal structure and generate derivative structures which can be input to first-principles calculations in order to explore the ground state energy landscape. CASM algorithmically constructs cluster expansions that fully couple discrete and continuous degrees of freedom, and generates highly efficient code to evaluate the cluster expansion basis functions. Widely used machine learning methods are integrated for fitting expansion coefficients to first-principle calculations. The fully parameterized cluster expansions can be combined with (kinetic) Monte Carlo methods to calculate finite temperature thermodynamic and kinetic properties. CASM Alloy Manager identifies distinct parent crystal structures in an alloy system, creating individual projects for each, and integrating the results. The integrated infrastructure facilitates the linkage between first-principles statistical mechanics predictions with higher length scale computational methods, such as phase field simulations. In conclusion, CASM projects are designed to be easy to share in repositories, to re-use, and to extend to include additional chemical species or types of degrees of freedom.

36 MATERIALS SCIENCE↗

TH-E-209-03: Development of An In-House CT Dose Monitoring and Management System Based On Open-Source Software Resources -- Pearls and Pitfalls

Radiation dose monitoring solutions have opened up new opportunities for medical physicists to be more involved in modern clinical radiology practices. In particular, with the help of comprehensive radiation dose data, data-driven protocol management and informed case follow up are now feasible. Significant challenges remain however and the problems faced by medical physicists are highly heterogeneous. Imaging systems from multiple vendors and a wide range of vintages co-exist in the same department and employ data communication protocols that are not fully standardized or implemented making harmonization complex. Many different solutions for radiation dose monitoring have been implemented by imaging facilities over the past few years. Such systems are based on commercial software, home-grown IT solutions, manual PACS data dumping, etc., and diverse pathways can be used to bring the data to impact clinical practice. The speakers will share their experiences with creating or tailoring radiation dose monitoring/management systems and procedures over the past few years, which vary significantly in design and scope. Topics to cover: (1) fluoroscopic dose monitoring and high radiation event handling from a large academic hospital; (2) dose monitoring and protocol optimization in pediatric radiology; and (3) development of a home-grown IT solution and dose data analysis framework. Learning Objectives: Describe the scope and range of radiation dose monitoring and protocol management in a modern radiology practice Review examples of data available from a variety of systems and how it managed and conveyed. Reflect on the role of the physicist in radiation dose awareness.

60 APPLIED LIFE SCIENCES↗

PyOECP: A flexible open-source software library for estimating and modeling the complex permittivity based on the open-ended coaxial probe (OECP) technique

Here, we present PyOECP, a Python-based flexible open-source software for estimating and modeling the complex permittivity obtained from the open-ended coaxial probe (OECP) technique. The transformation of the measured reflection coefficient to complex permittivity is performed based on three different methods. The software library contains the dielectric spectra of common reference liquids, which can be used to transform the reflection coefficient into the dielectric spectra. Several Python routines that are commonly employed (e.g., SciPy and NumPy) in the field of science and engineering are required only so that the users can alter the software structure depending on their needs. The modeling algorithm exploits the Markov Chain Monte Carlo method for the data regression. The discrete relaxation models can be built by a proper combination of well-known relaxation models. In addition to these models, electrode polarization, a typical measurement artifact for interpreting dielectric spectra, can be incorporated into the modeling algorithm. A continuous relaxation model, which solves the Fredholm integral equation of the first kind (a mathematically ill-posed problem), is also included. This open-source software enables users to freely adjust the physical parameters to obtain physical insight into their materials under test and will be consistently updated for more accurate measurement and interpretation of dielectric spectra in an automated manner. This work describes the theoretical and mathematical background of the software, lays out the workflow, and validates the software functionality based on both synthetic and empirical data included in the software.

97 MATHEMATICS AND COMPUTING↗