Search NASA⌕ Search

SEARCH · Search NASA

Results for “space radiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Statistical Properties of Undulator Radiation

Two experiments were carried out to study the statistical properties of undulator radiation in the Integrable Optics Test Accelerator (IOTA) storage ring at Fermilab. The first experiment studied the turn-to-turn fluctuations in the power of the radiation generated by an electron bunch. The magnitude of these fluctuations depends on the 6D phase-space distribution of the electron bunch. In IOTA, we demonstrated that this effect can be used to measure some electron bunch parameters, small transverse emittances in particular. In the second experiment, a single electron was stored in the ring, emitting a photon only once per several hundred turns. In this regime, any classical interference-related collective effects were eliminated, and the quantum fluctuations could be studied in detail to search for possible deviations from the expected Poissonian photon statistics. In addition, the photocount arrival times were used to track the longitudinal motion of a single electron and to compare it with simulations. This allowed us to determine several dynamical parameters of the storage ring such as the rf cavity phase jitter and the dependence of the synchrotron motion period on amplitude.

43 PARTICLE ACCELERATORS↗

Kilonova Detection

The first observation of gravitational waves (GW) from a binary neutron star collision, known as GW170817, was detected by Laser Interferometer Gravitational-Wave Observatory (LIGO) and Virgo GW observatories. This event marked a profound discovery of the kilonova, which occurs when two neutron stars collide, resulting in an energetically explosive release of gamma-ray bursts (GRBs) and emitting bright electromagnetic radiation. This project focuses on assessing how well kilonovae will be detected in the Legacy Survey of Space and Time (LSST) at the Vera C. Rubin Observatory. By using Kasen models with varying ejecta mass, ejecta velocity, and lanthanide fraction, we analyze these 329 models and create kilonova light curves to assess the number of visible kilonovae for each band, based on the minimum magnitude at various redshifts.

Khalid, Anna↗

Linear Time-Invariant Models of a Large Cumulus Ensemble

Abstract Methods in system identification are used to obtain linear time-invariant state-space models that describe how horizontal averages of temperature and humidity of a large cumulus ensemble evolve with time under small forcing. The cumulus ensemble studied here is simulated with cloud-system-resolving models in radiative–convective equilibrium. The identified models extend steady-state linear response functions used in past studies and provide accurate descriptions of the transfer function, the noise model, and the behavior of cumulus convection when coupled with two-dimensional gravity waves. A novel procedure is developed to convert the state-space models into an interpretable form, which is used to elucidate and quantify memory in cumulus convection. The linear problem studied here serves as a useful reference point for more general efforts to obtain data-driven and interpretable parameterizations of cumulus convection.

Meteorology & Atmospheric Sciences↗

High Performance Pd/4H-SiC Epitaxial Schottky Barrier Radiation Detectors for Harsh Environment Applications

Although many refractory metals have been investigated as the choice of contact metal in 4H-SiC devices, palladium (Pd) as a Schottky barrier contact for 4H-SiC radiation detectors for harsh environment applications has not been investigated adequately. Pd is a refractory metal with high material weight-to-thickness ratio and a work function as high as nickel, one of the conventional metal contacts for high performing 4H-SiC Schottky barrier detectors (SBDs). In this article, Pd/4H-SiC epitaxial SBDs have been demonstrated for the first time as a superior self-biased (0 V applied bias) radiation detector when compared to benchmark Ni/4H-SiC SBDs. The Pd/4H-SiC SBD radiation detectors showed a very high energy resolution of 1.9% and 0.49% under self- and optimized bias, respectively, for 5486 keV alpha particles. The SBDs demonstrated a built-in voltage (V bi ) of 2.03 V and a hole diffusion length (L d ) of 30.8 µm. Such high V bi and L d led to an excellent charge collection efficiency of 76% in the self-biased mode. Capacitance mode deep level transient spectroscopy (DLTS) results revealed that the “lifetime-killer” Z 1/2 trap centers were present in the 4H-SiC epilayer. Another deep level trap was located at 1.09 eV below the conduction band minimum and resembles the EH5 trap with a concentration of 1.98 × 10 11 cm –3 and capture cross-section 1.7 × 10 –17 cm –2 ; however, the detector performance was found to be limited by charge trapping in the Z 1/2 center. The results presented in this article revealed the unexplored potential of a wide bandgap semiconductor, SiC, as high-efficiency self-biased radiation detectors. Such high performance self-biased radiation detectors are poised to address the longstanding problem of designing self-powered sensor devices for harsh environment applications e.g., advanced nuclear reactors and deep space missions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Monte Carlo Laplace Transform Estimator for Radiation Transport

This work formulates and implements a Laplace transform estimator in a simple Monte Carlo radiation transport code. The estimator maps flux-based quantities of interest, like reaction rates, from a desired phase-space dimension to the complex Laplace domain. This on-the-fly Monte Carlo integration technique enables the spectral analysis of arbitrary nuclear systems via the Laplace transform. A simple code tests the estimator in neutron slowing-down problems across various infinite media, and the results compare well with Ganapol’s uninverted analytical solution of the neutron slowing-down equation.

97 MATHEMATICS AND COMPUTING↗

Dosimetric and biological impact of activity extravasation of radiopharmaceuticals in PET imaging

The increasing use of nuclear medicine and PET imaging has intensified scrutiny of radiotracer extravasation. To our knowledge, this topic is understudied but holds great potential for enhancing our understanding of extravasation in clinical PET imaging. This work aims to (1) quantify the absorbed doses from radiotracer extravasation in PET imaging, both locally at the site of extravasation and with the extravasation location as a source of exposure to bodily organs and (2) assess the biological ramifications within the injection site at the cellular level. A radiation dosimetry simulation was performed using a whole-body 4D Extended Cardiac-Torso (XCAT) phantom embedded in the GATE Monte Carlo platform. A 10-mCi dose of 18 F-FDG was chosen to simulate a typical clinical PET scan scenario, with 10% of the activity extravasated in the antecubital fossa of the right arm of the phantom. The extravasation volume was modeled as a 5.5 mL rectangle in the hypodermal layer of skin. Absorbed dose contributions were calculated for the first two half-lives, assuming biological clearance thereafter. Dose calculations were performed as absorbed doses at the organ and skin levels. Energy deposition was simulated both at the local extravasation site and in multiple organs of interest and converted to absorbed doses based on their respective masses. Each simulation was repeated ten times to estimate Monte Carlo uncertainties. Biological impacts on cells within the extravasated volume were evaluated by randomizing cells and exposing them to a uniform radiation source of 18 F and 68 Ga. Particle types, their energies, and direction cosines were recorded in phase space files using a separate Geant4 simulation to characterize their entry into the nucleus of the cellular volume. Subsequently, the phase space files were imported into the TOPAS-nBio simulation to assess the extent of DNA damage, including double-strand breaks (DSBs) and single-strand breaks (SSBs). Organ-level dosimetric estimations are presented for 18 F and 68 Ga radionuclides in various organs of interest. With 10% extravasation, the hypodermal layer of the skin received the highest absorbed dose of 1.32 ± 0.01 Gy for 18 F and 0.99 ± 0.01 Gy for 68 Ga. The epidermal and dermal layers received absorbed doses of 0.07 ± 0.01 Gy and 0.13 ± 0.01 Gy for 18 F, and 0.14 ± 0.01 Gy and 0.29 ± 0.01 Gy for 68 Ga, respectively. In the extravasated volume, 18 F caused an average absorbed dose per nucleus of 0.17 ± 0.01 Gy, estimated to result in 10.58 ± 0.50 DSBs and 268.11 ± 12.43 SSBs per nucleus. For 68 Ga, the absorbed dose per nucleus was 0.11 ± 0.01 Gy, leading to an estimated 6.49 ± 0.34 DSBs and 161.24 ± 8.12 SSBs per nucleus. Absorbed doses in other organs were on the order of micro-gray (µGy). The likelihood of epidermal erythema resulting from extravasation during PET imaging is low, as the simulated absorbed doses to the epidermis remain below the thresholds that trigger such effects. Moreover, the organ-level absorbed doses were found to be clinically insignificant across various simulated organs. The minimal DNA damage at the extravasation site suggests that long-term harm, such as radiation-induced carcinogenesis, is highly unlikely.

DNA strand breaks↗

Disentangling observable dependence in SCET I and SCET II anomalous dimensions: angularities at two loops

The resummation of radiative corrections to collider jet observables using soft collinear effective theory is encoded in differential renormalization group equations (RGEs), with anomalous dimensions depending on the observable under consideration. This observable dependence arises from the ultraviolet (UV) singular structure of real phase space integrals in the effective field theory. We show that the observable dependence of anomalous dimensions in SCET I problems can be disentangled by introducing a suitable UV regulator in real radiation integrals. Resummation in the presence of the new regulator can be performed by solving a two-dimensional system of RGEs in the collinear and soft sectors, and resembles many features of resummation in SCET II theories by means of the rapidity renormalization group. We study the properties of SCET I with the additional regulator and explore the connection with the system of RGEs in SCET II theories, highlighting some universal patterns that can be exploited in perturbative calculations. As an application, we compute the two-loop soft and jet anomalous dimensions for a family of recoil-free angularities and give new analytic results. This allows us to study the relations between the SCET I and SCET II limits for these observables. We also discuss how the extra UV regulator can be exploited to calculate anomalous dimensions numerically, and the prospects for numerical resummation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Disentangling core and edge mechanisms of the density limit in DIII-D negative triangularity plasmas

The density limit is investigated in the DIII-D negative triangularity plasmas which lack a standard H-mode edge. We find the limit may not be a singular disruptive boundary but a multifaceted density saturation phenomenon governed by distinct core and edge transport mechanisms. Sustained, non-disruptive operation is achieved at densities up to 1.8 times the Greenwald limit ($n_\mathrm{G}$) until the termination of auxiliary heating. Systematic power scans show distinct power scalings for the core ($n_e \propto P_\mathrm{SOL}^{0.27\pm0.03}$) and edge ($n_e \propto P_\mathrm{SOL}^{0.42\pm0.04}$) density limits. The edge density saturation is triggered by the onset of a non-disruptive, high-field side radiation front and the associated cooling, which clamps the edge density below . In contrast, the core density continues to rise until it saturates, a state characterized by enhanced core turbulence. Core transport evolves from a diffusive to an intermittent, avalanche-like state, as indicated by heavy-tailed probability density functions (kurtosis ≈ 6), increased Hurst exponents, and a $1/f$-type power spectrum. These findings suggest that the density limit in the low-confinement regime is determined by a combination of edge radiative cooling and core turbulent transport. This distinction provides separate targets for control strategies aimed at extending the operational space of future fusion devices.

density limit↗

Efficient end-to-end simulation of time-dependent coherent X-ray scattering experiments

Physical optics simulations for beamlines and experiments allow users to test experiment feasibility and optimize beamline settings ahead of beam time in order to optimize valuable beam time at synchrotron light sources like NSLS-II. Further, such simulations also help to develop and test experimental data processing methods and software in advance. The Synchrotron Radiation Workshop ( SRW ) software package supports such complex simulations. We demonstrate how recent developments in SRW significantly improve the efficiency of physical optics simulations, such as end-to-end simulations of time-dependent X-ray photon correlation spectroscopy experiments with partially coherent undulator radiation (UR). The molecular dynamics simulation code LAMMPS was chosen to model the sample: a solution of silica nanoparticles in water at room temperature. Real-space distributions of nanoparticles produced by LAMMPS were imported into SRW and used to simulate scattering patterns of partially coherent hard X-ray UR from such a sample at the detector. The partially coherent UR illuminating the sample can be represented by a set of orthogonal coherent modes obtained by simulation of emission and propagation of this radiation through the coherent hard X-ray (CHX) scattering beamline followed by a coherent-mode decomposition. GPU acceleration is added for several key functions of SRW used in propagation from sample to detector, further improving the speed of the calculations. The accuracy of this simulation is benchmarked by comparison with experimental data.

36 MATERIALS SCIENCE↗

Islands and Page curves in 4d from Type IIB

Variants of the black hole information paradox are studied in Type IIB string theory setups that realize four-dimensional gravity coupled to a bath. The setups are string theory versions of doubly-holographic Karch/Randall brane worlds, with black holes coupled to non-gravitating and gravitating baths. The 10d versions are based on fully backreacted solutions for configurations of D3, D5 and NS5 branes, and admit dual descriptions as N = 4 SYM on a half space and 3d $T$$^{σ}_{ρ}$ [SU(N)] SCFTs. Island contributions to the entanglement entropy of black hole radiation systems are identified through Ryu/Takayanagi surfaces and lead to Page curves. Analogs of the critical angles found in the Karch/Randall models are identified in 10d, as critical parameters in the brane configurations and dual field theories.

79 ASTRONOMY AND ASTROPHYSICS↗

4D insights into lithium-ion battery sidewall rupture during thermal runaway

Thermal runaway (TR), characterized by rapid exothermic reactions, presents a serious safety risk in lithium-ion batteries (LiBs). External triggers such as high temperatures, mechanical abuse, or internal short circuits (ISCs) can initiate TR, often resulting in sidewall rupture, which may escalate to catastrophic battery pack failure. In this study, we developed and applied high-speed synchrotron imaging techniques to investigate sidewall rupture mechanisms in LiBs subjected to different triggering scenarios. Using in situ 4D tomographic imaging, we visualized the dynamic evolution of sidewall rupture with high spatial and temporal resolution. The results revealed distinct failure behaviors linked to each trigger, underscoring the complex and condition-specific nature of sidewall breach and battery failure. These insights highlight the critical importance of implementing tailored safety strategies across diverse applications. Our findings demonstrate the powerful potential of synchrotron high-speed tomography as a diagnostic tool for advanced safety testing and cell qualification.

25 ENERGY STORAGE↗

RBSP-ECT Combined Pitch Angle Resolved Electron Flux Data Product

We describe a new data product combining pitch angle resolved electron flux measurements from the Radiation Belt Storm Probes (RBSP) Energetic Particle Composition and Thermal Plasma (ECT) suite on the National Aeronautics and Space Administration’s Van Allen Probes. Here, we describe the methodology used to combine each of the data sets and produce a consistent set of pitch-angle-resolved spectra for the entire Van Allen Probes mission. Three-minute-averaged flux spectra are provided spanning energies from 15 eV up to 20 MeV. This new data product offers researchers a consistent cross calibrated data set to explore the particle dynamics of the inner magnetosphere across a wide range of energies.

79 ASTRONOMY AND ASTROPHYSICS↗

A molecular ground electronic state with an occupied 5g spinor—The superheavy (E125)F molecule

Fully relativistic calculations, primarily at the 4-component coupled-cluster singles and doubles with perturbative triples [CCSD(T)] level of theory with the Dirac–Coulomb (DC) Hamiltonian, have been carried out for the superheavy (E125)F molecule using large Gaussian basis sets. The electronic ground state is determined to have an [Og]8s 2 5g 1 6f 3 configuration on E125 with an Ω = 6 ground state and an 8p electron largely donated to F. A Mulliken population analysis indicates that the ground state is mainly ionic with a partial charge of +0.79 on E125 and a single sigma bond involving the F 2p and E125 8p spinors. The occupied g spinor is not involved in the bonding. With the largest basis set used in this work, the (0 K) dissociation energy was calculated at the DC-CCSD(T) level of theory to be 7.02 eV. Analogous calculations were also carried out for the E125 atom, both the neutral and its cation. The lowest energy electron configuration of E125 + , [Og]$8s$$^{2}_{1/2}$$5g$$^{1}_{7/2}$$6f$$^{3}_{5/2}$ with a J = 6 ground state, was found to be similar to that in (E125)F, while the neutral E125 atom has an [Og]$8s$$^{2}_{1/2}$$5g$$^{1}_{7/2}$$6f$$^{2}_{5/2}$$7d$$^{1}_{3/2}$$8p$$^{1}_{1/2}$ ground state electron configuration with a J = 17/2 ground state. The ionization energy (IE) of E125 is reported for the first time and is calculated to be 4.70 eV at the DC-CCSD(T) level of theory. Non-relativistic calculations were also carried out on the E125 atom and the (E125)F molecule. Here, the non-relativistic ground state of the E125 atom was calculated to have a 5g 5 ground state with an IE of just 3.4 eV. The net effect of relativity on (E125)F is to stabilize its bonding.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Upgrade and characterization of the fast-channels of Imaging Neutral Particle Analyzers in the DIII-D tokamak

This publication presents the characterization of the recently upgraded fast (MHz) channels of the DIII-D Imaging Neutral Particle Analyzers. The new system allows for a phase space resolution of < 10 keV and < 10 cm. The main source of noise is due to the background radiation (neutrons and gammas) present in the diagnostic lab during experiments, which can hit the photomultipliers and generate large spikes in signal. Good linear correlations (r 2 > 0.9) are found between the average rate of noise spikes in the fast channels and the average neutron rate. Additional noise is caused by the scintillation of the optical fibers used to guide the signal to the acquisition system, which is induced by neutron and gamma impacts. A correlation factor r 2 > 0.6 between the baseline noise caused by this scintillation and the signals in the neutron diagnostic was found. Possible mitigation strategies, such as the use of shielding and filters, are discussed. These allow to reduce the noise spike rate by an order of magnitude and the noise baseline by a factor 4. Despite the noise, it is shown that the upgraded fast channels provide enough signal-to-noise ratio to observe coherent fluctuations of the energetic particle population.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of the inclusive isolated-photon production cross section in pp and Pb–Pb collisions at $\mathbf {\sqrt{\textit{s}_{NN }} = 5.02}$ TeV

The ALICE Collaboration at the CERN LHC has measured the inclusive production cross section of isolated photons at midrapidity as a function of the photon transverse momentum (p$^{γ}_{T}$), in Pb–Pb collisions in different centrality intervals, and in pp collisions, at centre-of-momentum energy per nucleon pair of $\sqrt{s_{NN}}$ = 5.02 TeV. The photon transverse momentum range is between 10–14 and 40–140 GeV/c, depending on the collision system and on the Pb–Pb centrality class. The result extends to lower p$^{γ}_{T}$ than previously published results by the ATLAS and CMS experiments at the same collision energy. The covered pseudorapidity range is |η γ | < 0.67. The isolation selection is based on a charged particle isolation momentum threshold p$^{iso, ch}_{T}$ GeV/c within a cone of radii R = 0.2 and 0.4. The nuclear modification factor is calculated and found to be consistent with unity in all centrality classes, and also consistent with the HG-PYTHIA model, which describes the event selection and geometry biases that affect the centrality determination in peripheral Pb–Pb collisions. The measurement is compared to next-to-leading order perturbative QCD calculations and to the measurements of isolated photons and Z 0 bosons from the CMS experiment, which are all found to be in agreement.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

System size and energy dependence of the mean transverse momentum fluctuations at the LHC

Event-by-event fluctuations of the event-wise mean transverse momentum, $\langle$p T $\rangle$, of charged particles produced in proton–proton (pp) collisions at $\sqrt{s}$ = 5.02 TeV, Xe–Xe collisions at $\sqrt{s_{NN}}$ = 5.44 TeV, and Pb–Pb collisions at $\sqrt{s_{NN}}$ = 5.02 TeV are studied using the ALICE detector based on the integral correlator $\langle$$\langle$Δp T Δp T $\rangle$$\rangle$. The correlator strength is found to decrease monotonically with increasing produced charged-particle multiplicity measured at midrapidity in all three systems. In Xe–Xe and Pb–Pb collisions, the multiplicity dependence of the correlator deviates significantly from a simple power-law scaling as well as from the predictions of the HIJING and AMPT models. The observed deviation from power-law scaling is expected from transverse radial flow in semicentral to central Xe–Xe and Pb–Pb collisions. In pp collisions, the correlation strength is also studied by classifying the events based on the transverse spherocity, S 0 , of the particle production at midrapidity, used as a proxy for the presence of a pronounced back-to-back jet topology. Low-spherocity (jetty) events feature a larger correlation strength than those with high spherocity (isotropic). The strength and multiplicity dependence of jetty and isotropic events are well reproduced by calculations with the PYTHIA 8 and EPOS LHC models.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

radkit v1.2

The radkit software suite (python) consists of three primary libraries: stark, trajan, and curie. The trajan library provides the tools to analyze and manipulate data from lidar and inertial measurement unit (IMU) devices as well as trajectories from algorithms such as simultaneous localization and mapping (SLAM). These components allow reading and writing standard data formats, performing rigid affine transformations, discretizing three-dimensional space, and visualizing data products. The curie library comprises a standard set of object-oriented tools for radiation data and analysis in the following modules: (1) listmode and binmode data classes with methods for manipulation, plotting, slicing and file IO; (2) radiological/nuclear source detection/identification analysis results; (3) source encounters of correlated analyses and (4) energy-dependent angular detector response functions. The stark package provides low-level tools that are leveraged by both curie and trajan. The tools are flexible for offline analysis as well as performant for real-time integrations. The radkit libraries have associated Robot Operating System packages for use in real-time and robotic systems.

Joshi, Tenzing↗

radkit base v1.6

The radkit (base) software suite (python) consists of three primary libraries: stark, trajan, and curie. The trajan library provides the tools to analyze and manipulate data from lidar and inertial measurement unit (IMU) devices, cameras, as well as trajectories from algorithms such as simultaneous localization and mapping (SLAM). These components allow reading and writing standard data formats, performing rigid affine transformations, discretizing three-dimensional space, and visualizing data products. The curie library comprises a standard set of object-oriented tools for radiation data and analysis in the following modules: (1) listmode and binmode data classes with methods for manipulation, plotting, slicing and file IO; (2) radiological/nuclear source detection/identification analysis results; (3) source encounters of correlated analyses and (4) energy-dependent angular detector response functions. The stark package provides low-level tools that are leveraged by both curie and trajan. The tools are flexible for offline analysis as well as performant for real-time integrations.

Salathe, Marco [Lawrence Berkeley National Laborat↗