Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectrographs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Spectrophotometry of Pluto from 3500 to 7350 A

Spectra of Pluto have been obtained on six nights during February 1979 by the use of the Cassegrain Digicon spectrograph on the 2.1-m Struve reflector and the IDS spectrograph on the 2.7-m reflector of McDonald Observatory. These spectra, with nominal resolution of 6-7 A, have been reduced to relative fluxes. Relative albedos were then calculated using the solar irradiances of Arvesen et al. (1969). The spectra taken in the blue show no indication of the upturn in albedo at wavelengths less than 3800 A previously reported by Fix, et al. (1970). The lack of a UV upturn cannot be interpreted in terms of a Rayleigh scattering atmosphere unless the albedo of the underlying surface is known. From the lack of methane absorption at the wavelength of the 6190- or 7270-A methane bands, an upper limit of 1-3 m-am of gaseous CH4 is derived. The albedo curve has a constant slope between 3500 and 7300 A. The only other solar system body which has this feature is an S-type asteroid.

Barker, E. S.↗

Measurements of mass flow in the transition region and inner corona

A solar rocket experiment launched on June 5, 1979 is described which provides high spectral resolution line profiles across the solar disk. The instrument consists of a small telescope with moderate spatial resolution and a spectrograph with stability and high spectroscopic resolution (about 0.028 A at 600 A). The detector system uses a microchannel plate array to provide 1,024 simultaneous measurements spanning approximately 30 A of the solar spectrum. The spectrograph uses a 3600 l/mm grating, and the spectral range 609-634 A is recorded in second order overlapping 1218-1268 A in first order. The position of the emission lines is determined by a center-of-mass routine and velocity shifts are evident. The qualitative results are in general agreement with the results of Cushman and Rense (1976).

Rottman, G. J.↗

State-of-the-art Space Telescope Digicon performance data

The Digicon has been chosen as the detector for the High Resolution Spectrograph and the Faint Object Spectrograph of the Space Telescope. Both tubes are 512 channel, parallel-output devices and feature CsTe photocathodes on MgF2 faceplates. Using a computer-assisted test facility, the tubes have been characterized with respect to diode array performance, photocathode response (1100-9000 A), and imaging capability. Data are presented on diode dark current and capacitance distributions, pulse height resolution, photocathode quantum efficiency, uniformity and blemishes, dark count rate, distortion, resolution, and crosstalk.

Ginaven, R. O.↗

The aluminum I autoionization doublet in the quiet solar spectrum

Observations are presented of the Al I autoionization doublet 1932 A and 1936 A in the quiet solar spectrum, obtained from the NRL slit spectrograph aboard Skylab and from the University of Hawaii Echelle Rocket Spectrograph. The observed profiles are compared with theoretical spectra computed for the Harvard Smithsonian Reference Atmosphere and the Vernazza, Avrett and Loeser (1976) solar models. It is found that nonlocal thermodynamic equilibrium effects are important in the line-formation problem and the synthetic spectra are in good agreeement with the data.

Heasley, J. N.↗

The Space Telescope

The Space Telescope, still under construction, is discussed in light of the constraints imposed on ground-based telescopes. The history of the Space Telescope is traced from its conceptual origin to its actual construction, and design considerations used to determine the Space Telescope construction are described. The optical system of the telescope will have an aperture of 2.4 m, a focal ratio of 24, and a front of primary to focus of 1.5 m. The fine guidance system will use astigmatic images at the edge of the field of view to provide the guidance signal for maintaining stability to 0.007 arcseconds. The guidestars are required for 85% of random fields located at the galactic poles, and the system sensitivity must meet performance specifications for stars brighter than 13.5 magnitude. The scientific instruments - the wide field camera, the faint object camera, the faint object spectrograph, the high resolution spectrograph, the high speed photometer, and the fine guidance sensors - are discussed in detail. Finally, the operations system, including schedule contraints and the Science Institute, is presented.

Odell, C. R.↗

Spectroscopic observations of comets

Development of a spectrograph using a microchannel plate intensifier for observing faint comets is described. The spectrograph is capable of obtaining useful spectra of objects as faint as M(2) = 18. The increased guiding efficiency achieved by the optical coupling of the ISIT vidicon of the 154 cm telescope has resulted in a better signal to noise ratio. The ability to take a direct image of the comet aids in the interpretation of the spatial profile of the emissions. Spectra of comets Schwassmann-Wachmann 1, Bradfield, Encke, Tuttle, and Stephen-Oterma are discussed.

Source record↗

Ultraviolet spectroscopy of comets using sounding rockets, IUE and Spacelab

Information was obtained from the IUE observations as a result of the high spatial resolution capability of the IUE spectrographs and the ability to observe the comet over an extended range of heliocentric distance. The IUE spectrographs also have a high dispersion capability which so far has been used to obtain high resolution spectra of the OH and CS bands.

Feldman, P. D.↗

High-resolution ultraviolet solar observations from sounding rockets and Spacelab

High spatial (about 1 arcsec) and temporal (20 sec) resolution UV solar spectroscopy has been carried out by the Naval Research Laboratory from sounding rockets since 1975. The High Resolution Telescope and Spectrograph payload, consisting of a 300 mm diameter x 4500 mm focal length Cassegrain telescope and the tandem Woodsworth spectrograph, was used to make the observations. Using this instrument, a multitude of highly energetic phenomena can be observed in the chromosphere, transition zone, and corona. High-resolution photographs of the UV continuum at 1600 A, used to study the fine structure and evolution of the temperature minimum layer, show that because of its strong spatial and temporal intensity fluctuations, the 1600 A continuum emission comes from not only the temperature minimum, but a variety of temperature regimes. Similar spatial and temporal behavior is seen in lower chromospheric lines of Si I. Typical line profiles of the C IV 1550 A line illustrate the fine structure and dynamics of the transition zone; the mass and energy flux balance in this zone is also determined.

Brueckner, G. E.↗

Collecting Light From Point Images

Light from sources at varying positions brought to fixed opening. In telescope field divided into 10 strips, 10 pairs of optical fibers moved laterally and longitudinally to any required position in their assigned strips. Fixed ends of fibers arrayed in line at spectrograph entrance slit. Concept developed to enhance efficiency of spectrographs on astronomical telescopes.

Goss, W. C.↗

Space Telescope - Eye on the universe

The NASA Space Telescope, which is to be put into orbit by the Space Shuttle in 1985, is described with attention to the design characteristics and fabrication processes of its optics and the five scientific instruments that will be mounted at the focal plane, behind the primary mirror. The primary mirror is fabricated from Ultra Low Expansion Glass, weighed 907 kg as a blank and took three and a half years to grind and polish to a deviation of no more than 0.000025 mm from the ideal surface. The instruments carried are the Wide Field Planetary Camera, which employs CCD detectors, the Faint Object Camera, the Faint Object Spectrograph, for use at visible and UV wavelengths, the UV High Resolution Spectrograph for 1100-2300 A wavelengths, and the High Speed Photometer for the study of time-dependent brightness fluctuations.

Davies, J. K.↗

Multiple object fiber optic spectroscopy

The Steward Observatory of the University of Arizona employs short optical fiber lengths to bring light from galaxy images at the 2.3 m telescope's focus to a line along a spectrograph slit, thereby obtaining simultaneous spectra of many objects of the field of view. After describing this instrument, attention is given to the development of an improved version through which efficiency gains will be obtained by remotely positioning the fibers under computer control and by correctly matching fiber outputs to the spectrograph optics. A CCD will replace the presently employed image tube and photographic plate detector system, in order to permit sky subtraction, yield increased dynamic range, and provide more accurate wavelength calibration due to the detector's fixed format.

Hill, J. M.↗

Astronomical application of IR CID technology

A portable microcomputer data system was developed to test a 2 x 64-element Si:Bi charge injection device (CID) infrared detector array on the Lick Observatory Shane telescope. An existing 0.5 m spectrograph was used for the tests after modification, and a spectral resolution of 1000 was achieved. Slow device response, due to the low background conditions in the spectrograph were shown. Astronomical data were later obtained, and a device read noise on the order of a few hundred electrons was achieved. The signal to noise ratios of the resulting spectra were about a factor of five lower than what could have been achieved with discrete photoconductive detectors. It is concluded that the CID array is competitive for applications in backgrounds lower than those used in the tests.

Rank, D. M.↗

NASA-Texas Planetary Program

Astronomical observations performed at the McDonald Observatory were summarized. Various spectra obtained from Jupiter, Uranus, Saturn, Neptune, Pluto, Titan, Iapetus, and sundry asteroids were described briefly. Spectra taken of various comets using an IDS (Intensified Dissector Scanner) spectrograph on a 2.7 m telescope were reviewed. The Octicon, a linear array of eight 1872-element Reticon arrays that was installed in the 2.7 m coude spectrograph at the observatory, was described. The 2.7 m coude scanner, 2.7 m coude CCD (charge coupled device), and 2.7 m radial velocity spectrometer were mentioned.

Smith, H. J.↗

Instrumentation studies for FUSE-Columbus

Telescope and spectrograph design for the Columbus ultraviolet astronomy satellite are described. A 1m mirror two-piece glancing incidence telescope design is suggested. A classical Rowland spectrograph is potentially the only design with efficiencies great enough to deliver the 100 sqcm net collecting area specified from a manageable telescope.

Osantowski, J. F.↗

Ultraviolet high-resolution spectroscopy from the Space Telescope

The High Resolution Spectrograph is one of five scientific instruments which will be part of the Space Telescope observatory. The spectrograph was designed to take advantage of the imaging and pointing capabilities of the telescope to obtain ultraviolet spectra with spectral resolution comparable to large, ground-based coudeinstruments. Some of the results of the ground-based testing program will be described, along with applications of these properties to future science programs.

Ebbets, D. C.↗

A spectroscopic method for calibration of solar extreme ultraviolet instrumentation

A method of calibrating solar extreme ultraviolet spectrographs in space using coronal emission lines of known relative intensity is presented and demonstrated. This approach is useful for recalibrating orbiting instruments that may be subject to degradation during extended periods of operation. The calibration results are insensitive to the physical distribution of emitting plasma in any likely solar coronal source. It is suggested that this technique may be useful for calibration of spectrographs used in the study of laboratory plasmas.

Neupert, W. M.↗

The kinematics and structure of N63A and associated H II regions

Shull (1983) and Shull et al. (1982) discussed very high resolution spectrographic observations of bright knots in the filaments of the Cygnus Loop, IC 443, Puppis A, and Vela X supernova remnants (SNRs). Information on the small-scale thermal, turbulent, and bulk radial motions of the gas in these galactic remnants was obtained on the basis of an analysis of the spectral-line profiles. An analysis by Shull (1983) of N49, located in the Large Magellanic Cloud (LMC) is concerned with the large-scale structural and kinematic properties of N49 as it evolves in a cloudy interstellar medium (ISM). The present investigation represents the companion analysis of N63A, which is also a Type II SNR in the LMC. Echelle spectrograph observations indicate, for the first time, the large-scale kinematic and structural properties of the N63A system. They show clearly that the SNR, like N49, is evolving in a clumpy ISM.

Shull, P., Jr.↗