Search NASA⌕ Search

SEARCH · Search NASA

Results for “spectrometry optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

It's a Trap! A Review of MOMA and Other Ion Traps in Space or Under Development

Since the Viking Program, quadrupole mass spectrometer (QMS) instruments have been used to explore a wide survey of planetary targets in our solar system, including (from the inner to outer reaches): Venus (Pioneer); our moon (LADEE); Mars (Viking, Phoenix, and Mars Science Laboratory); and, Saturns largest moon Titan (Cassini-Huygens). More recently, however, ion trap mass spectrometer (ITMS) instruments have found a niche as smaller, versatile alternatives to traditional quadrupole mass analyzers, capable of in situ characterization of planetary environments and the search for organic matter. For example, whereas typical QMS systems are limited to a mass range up to 500 Da and normally require multiple RF frequencies and pressures of less than 10(exp -6) mbar for optimal operation, ITMS instruments commonly reach upwards of 1000 Da or more on a single RF frequency, and function in higher pressure environments up to 10(exp -3) mbar.

ion trap↗

Effect of chlorination on the TlBr band edges for improved room temperature radiation detectors: Effect of chlorination on the TlBr band edges for radiation detectors

Thallium bromide (TlBr) crystals subjected to hydrochloric acid (HCl) chemical treatments have been shown to advantageously affect device performance and longevity in TlBr-based room temperature radiation detectors, yet the exact mechanisms of the improvements remain poorly understood. Here in this paper, we investigate the influence of several HCl chemical treatments on device-grade TlBr and describe the changes in the composition and electronic structure of the surface. Composition analysis and depth profiles obtained from secondary ion mass spectrometry (SIMS) identify the extent to which each HCl etch condition affects the detector surface region and forms of a graded TlBr/TlBr 1-x CL x surface heterojunction. Using a combination of X-ray photoemission spectroscopy (XPS) and hybrid density functional calculations, we are able to determine the valence band offsets, band gaps, and conduction band offsets as a function of Cl content over the entire composition range of TIBr 1-x C1 X . This study establishes a strong correlation between device process conditions, surface chemistry, and electronic structure with the goal of further optimizing the long-term stability and radiation response of TlBr-based detectors.

36 MATERIALS SCIENCE↗

Installation protocol for charge transfer dissociation mass spectrometry on ion trapping mass spectrometers

Abstract Rationale Charge transfer dissociation (CTD) is a novel fragmentation technique that demonstrates enhanced structural characterization for a wide variety of molecules compared to standard fragmentation techniques like collision‐induced dissociation (CID). Alternative fragmentation techniques, such as electron transfer dissociation, electron capture dissociation, and ultraviolet photodissociation, also overcome many of the shortfalls of CID, but none of them are a silver bullet that can adequately characterize a wide variety of structures and charge states of target compounds. Given the diversity of structural classes and their occasional obstinance towards certain activation techniques, alternative fragmentation techniques are required that rely on novel or alternative modes of activation. Methods Herein, we present a step‐by‐step protocol for the installation of CTD on a quadrupole ion trap mass spectrometer and best practices for optimizing the signal‐to‐noise ratio and acquisition times for CTD mass spectra. Results In addition to two CTD installations in the Jackson laboratory, CTD has also been installed, and is currently in operation, on two 3D ion trap mass spectrometers in France: one in the laboratory of Dr. David Ropartz and Dr. Hélène Rogneaux at INRAE in Nantes, and the other in the laboratory of Dr. Jean‐Yves Salpin at Université d'Évry Val‐d'Essonne, part of the Paris‐Saclay University system. Conclusions Here, we provide a visual protocol to help others accomplish the instrument modification.

47 OTHER INSTRUMENTATION↗

Development of ultralow energy (1–10 eV) ion scattering spectrometry coupled with reflection absorption infrared spectroscopy and temperature programmed desorption for the investigation of molecular solids

Extremely surface specific information, limited to the first atomic layer of molecular surfaces, is essential to understand the chemistry and physics in upper atmospheric and interstellar environments. Ultra low energy ion scattering in the 1–10 eV window with mass selected ions can reveal extremely surface specific information which when coupled with reflection absorption infrared (RAIR) and temperature programmed desorption (TPD) spectroscopies, diverse chemical and physical properties of molecular species at surfaces could be derived. These experiments have to be performed at cryogenic temperatures and at ultra high vacuum conditions without the possibility of collisions of neutrals and background deposition in view of the poor ion intensities and consequent need for longer exposure times. Here we combine a highly optimized low energy ion optical system designed for such studies coupled with RAIR and TPD and its initial characterization. Despite the ultralow collision energies and long ion path lengths employed, the ion intensities at 1 eV have been significant to collect a scattered ion spectrum of 1000 counts/s for mass selected CH{sub 2}{sup +}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrasensitive Nanoelectrospray Ionization-Mass Spectrometry using Poly(dimethylsiloxane) Microchips with Monolithically Integrated Emitters

Poly(dimethylsiloxane) (PDMS) is the most widely used substrate for microfluidic devices as it enables facile fabrication and has other distinctive properties. However, for applications involving highly sensitive nanoelectrospray ionization mass spectrometry (nanoESI-MS) detection, the use of PDMS microdevices has been hindered by the leaching of uncross-linked oligomers and other contaminants from the substrate that yields a large background of chemical noise in the mass spectra. A more general challenge is that microfluidic devices containing integrated electrospray emitters are frequently unable to operate stably in the nanoflow regime where the best sensitivity is achieved. In this report, we extracted the contaminants from PDMS substrates using a series of solvents, eliminating the background observed when untreated PDMS microchips are used for nanoESI-MS. Optimization of the integrated emitter geometry enabled stable operation at flow rates as low as 10 nL/min. Peptide concentrations of 1 nM were readily detected, representing ~170 zmol of consumed analyte, and an extrapolated detection limit of ~40 zmol; these are the lowest mass and concentration detection limits reported to date for a microchip having an integrated electrospray emitter.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Defining the Antitumor Mechanism of Action of a Clinical-stage Compound as a Selective Degrader of the Nuclear Pore Complex

Cancer cells are acutely dependent on nuclear transport due to elevated transcriptional activity, suggesting an unrealized opportunity for selective therapeutic inhibition of the nuclear pore complex (NPC). Through large-scale phenotypic profiling of cancer cell lines, genome-scale functional genomic modifier screens, and mass spectrometry–based proteomics, we discovered that the clinical drug PRLX-93936 is a molecular glue that binds and reprograms the TRIM21 ubiquitin ligase to degrade the NPC. Upon compound-induced TRIM21 recruitment, the nuclear pore is ubiquitylated and degraded, resulting in the loss of short-lived cytoplasmic mRNA transcripts and the induction of cancer cell apoptosis. Direct compound binding to TRIM21 was confirmed via surface plasmon resonance and X-ray crystallography, whereas compound-induced TRIM21–nucleoporin complex formation was demonstrated through multiple orthogonal approaches in cells and in vitro. Phenotype-guided optimization yielded compounds with 10-fold greater potency and drug-like properties, along with robust pharmacokinetics and efficacy against pancreatic cancer xenografts and patient-derived organoids.

Yuan, Linjie [Stanford School of Medicine, CA (Uni↗

New Cluster Secondary Ions for Quantitative Analysis of the Concentration of Boron Atoms in Diamond by Time-of-Flight Secondary-Ion Mass Spectrometry

A new approach to quantitative analysis of the concentration of boron atoms in diamond using secondary- ion mass spectrometers with time-of-flight mass analyzers is proposed. Along with the known boron-containing lines (B, BC, BC{sub 2}), many lines related to cluster secondary ions BC{sub N} have been found in the mass spectrum; their intensity increases by one or two orders of magnitude when Bi{sub 3} probe ions are used. Lines BC{sub 4}, BC{sub 6}, BC{sub 2}, and BC{sub 8} have the highest intensity (in the descending order); when they are summed, the sensitivity increases by an order of magnitude in comparison with the known mode of detecting BC{sub 2}. The parameters of the boron δ-layer in single-crystal diamond films grown under optimal conditions have been measured to be unprecedented: the δ-layer width is about 2 nm, and the concentration is 6.4 × 10{sup 20} cm{sup –3} (the boron concentrations for doped and undoped diamonds differ by four orders of magnitude).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

New synthetic route to Mg–Al–CO{sub 3} layered double hydroxide using magnesite

Highlights: ► The use of magnesite to prepare Mg–Al–CO{sub 3} LDH is novel. ► The result sample is systematically studied. ► Furthermore, the cost of preparing Mg–Al–CO{sub 3} LDH may be reduced through this synthetic route. ► In the synthesis process, there is no CO{sub 2} released. That is significant to environmental protection. - Abstract: A novel synthesis of Mg–Al–CO{sub 3} layered double hydroxide (LDH) through chemical precipitation and hydrothermal methods has been investigated in this paper. The advantages of this method are using magnesite as magnesium source and no CO{sub 2} released in the process of preparation. Mg–Al–CO{sub 3} LDH (ZY) prepared under the optimized condition (the molar ratio of magnesite and Al(NO{sub 3}){sub 3}·9H{sub 2}O was 2.5:1; the aging time and temperature were 16 h and 100 °C, respectively) was characterized by X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FT-IR), thermo-gravimetric and differential thermal analyser (TG–DTA) and scanning electron microscope (SEM). The crystal morphology of the prepared LDH displays platelet-like structure with a hexagonal shape, which is agreed with the LDH produced by industrial chemicals. Through elemental analysis and inductively coupled plasma-atomic emission spectrometry (ICP-AES), the chemical formula of ZY is determined as Mg{sub 0.70}Al{sub 0.30}(OH){sub 2}(CO{sub 3}){sub 0.15}·0.6H{sub 2}O.

36 MATERIALS SCIENCE↗

Oxygen redox activities governing high-voltage charging reversibility of Ni-rich layered cathodes

A schematic illustration indicative of the improved structural reversibility through stabilizing oxidized oxygen by Al doping. The chemical reactions and phase transitions at high voltages are generally considered to determine the electrochemical properties of high-voltage layered cathodes such as Ni-rich rhombohedral oxides. Even if significantly higher SOCs (states-of-charge) are utilized above the capability of transition metal redox (primarily Ni and Co), the effect of oxygen redox on Ni-rich rhombohedral oxides still looks mysterious thereby necessitating research that can clarify the relationship between redox reactions and phase transitions. Here, we performed a comprehensive and comparative study of the cationic and anionic redox reactions, as well as the structural evolution of a series of commercial Ni-rich layered oxides with and without Al doping. We combined the results from X-ray spectroscopy, operando electrochemical mass spectrometry, and neutron diffraction with electrochemical properties and thereby revealed the different oxygen redox activities associated with structural and electrochemical degradations. We reveal that Al doping suppresses the irreversible oxygen release but enhances the lattice oxygen oxidization. With this modulated oxygen redox activity, the Ni-rich layered oxides’ notorious H2–H3 structural phase transition becomes highly reversible. Our findings disentangle the different oxygen redox activities during high-voltage cycling and clarify the role of dopants in the Ni-rich layered oxides in terms of structural and electrochemical stability, shedding light on the future direction of optimizing layered cathode materials for safer high energy-density secondary batteries.

Lee, Gi-Hyeok↗

Summary of Disposable Debris Shields (DDS) Analysis for Development of Solid Debris Collection at NIF

Collection of solid debris from the National Ignition Facility (NIF) is being developed both as a diagnostic tool and as a means for measuring nuclear reaction cross sections relevant to the Stockpile Stewardship Program and nuclear astrophysics. The concept is straightforward; following a NIF shot, the debris that is produced as a result of the capsule and hohlraum explosion would be collected and subsequently extracted from the chamber. The number of nuclear activations that occurred in the capsule would then be measured through a combination of radiation detection and radiochemical processing followed by mass spectrometry. Development of the catcher is challenging due to the complex environment of the NIF target chamber. The collector surface is first exposed to a large photon flux, followed by the debris wind that is produced. The material used in the catcher must be mechanically strong in order to withstand the large amount of energy it is exposed to, as well as be chemically compatible with the form and composition of the debris. In addition, the location of the catcher is equally important. If it is positioned too close to the center of the target chamber, it will be significantly ablated, which could interfere with the ability of the debris to reach the surface and stick. If it is too far away, the fraction of the debris cloud collected will be too small to result in a statistically significant measurement. Material, geometric configuration, and location must all be tested in order to design the optimal debris collection system for NIF. One of the first ideas regarding solid debris collection at NIF was to use the disposable debris shields (DDS), which are fielded over the final optics assemblies (FOA) 7 m away from the center of the target chamber. The DDS are meant to be replaced after a certain number of shots, and if the shields could be subsequently analyzed after removal, it would serve as a mechanism for fielding a relatively large collection area through the use of a part meant to be replaced regularly. The solid angle covered by one of the shields is roughly 10 -4 of 4π. If several shields were analyzed at once, it would increase the solid angle of the collection area accordingly. The glass shields consist of ammonia hardened silica with a sol gel coating and kapton tape around the edge. The square sheets are 14-inch on each side. The original shields were 1 mm thick, but it was determined that a thicker shield (3.3 mm) was more effective in preventing debris from reaching the FOA. The Solid Radchem group received two sets of DDS as part of our evaluation of the potential use of the DDS as solid debris collectors. The first set consisted of two 3.3 mm shields, one each from the top and bottom of the chamber (the '3mm set'). The second set consisted of four 1mm shields, one from the top of the chamber and the other three from the bottom (the 'IFSA set'). For each set, the shields were cut into smaller subsamples, which were then imaged using scanning electron microscopy (SEM) followed by chemical leaching and mass spectrometry. The purpose was to evaluate both the quantity and identity of the debris that was present on the DDS surfaces, and to determine if any of the capsule debris was reaching the chamber walls. In addition, potential enhancement due to gravity in the chamber was evaluated by directly comparing shields fielded in the top and bottom of the chamber. Based on the results, the use of the DDS as debris collectors would be evaluated. The results from both sets were presented to the DDS Working Group. The slides are attached to this document. The 3mm set results are presented first, followed by the results from the IFSA set. In both cases it was determined that a small fraction of the overall debris field was collected on the DDS. This means that the debris that is formed during a NIF shot is condensing out of the plasma and depositing on surfaces closer to the target chamber center, or else it is simply falling to the bottom of the chamber. In either case, it was determined that using the DDS, or fielding a debris collector at the chamber wall, was not feasible for solid debris collection at NIF due to the small amount of debris that had been collected. In addition, since the glass shields suffered quite a bit of damage from particles impacting the surface, glass was ruled out as a collection medium.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Correlation of rocket propulsion fuel properties with chemical composition using comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry followed by partial least squares regression analysis

There is an increased need to more fully assess and control the composition of kerosene based rocket propulsion fuels, namely RP-1 and RP-2. In particular, it is crucial to be able to make better quantitative connections between the following three attributes: (a) fuel performance, (b) fuel properties (flash point, density, kinematic viscosity, net heat of combustion, hydrogen content, etc) and (c) the chemical composition of a given fuel (i.e., specific chemical compounds and compound classes present as a result of feedstock blending and processing). Indeed, recent efforts in predicting fuel performance through modeling put greater emphasis on detailed and accurate fuel properties and fuel compositional information. In this regard, advanced distillation curve (ADC) metrology provides improved data relative to classical boiling point and volatility curve techniques. Using ADC metrology, data obtained from RP-1 and RP-2 fuels provides compositional variation information that is directly relevant to predictive modeling of fuel performance. Often, in such studies, one-dimensional gas chromatography (GC) combined with mass spectrometry (MS) is typically employed to provide chemical composition information. Building on approaches using GC-MS, but to glean substantially more chemical composition information from these complex fuels, we have recently studied the use of comprehensive two dimensional gas chromatography combined with time-of-flight mass spectrometry (GC × GC - TOFMS) to provide chemical composition data that is significantly richer than that provided by GC-MS methods. In this report, by applying multivariate data analysis techniques, referred to as chemometrics, we are able to readily model (correlate) the chemical compositional information from RP-1 and RP-2 fuels provided using GC × GC - TOFMS, to the fuel property information such as that provided by the ADC method and other specification properties. We anticipate that this new chemical analysis strategy will have broad implications for the development of high fidelity composition-property models, leading to an optimized approach to fuel formulation and specification for advanced engine cycles.

fuel↗

External Beam Radiation Therapy and Abiraterone in Men With Localized Prostate Cancer: Safety and Effect on Tissue Androgens

Purpose: Optimizing androgen suppression may provide better control of localized prostate cancer (PCa). Numerous trials have supported the benefit of combining androgen deprivation therapy with definitive radiation therapy in men with locally advanced or high-grade disease. Addition of abiraterone to luteinizing hormone-releasing hormone agonist (LHRHa) with radiation has not been reported. We examined the safety of this combination as well as its impact on androgen suppression. Methods and Materials: A prospective, phase 2 study was conducted in men with localized PCa treated with 6 months of neoadjuvant and concurrent abiraterone with LHRHa and radiation. Duration of adjuvant LHRHa was at the discretion of the treating clinician. Prostate biopsy assays were obtained prior to the start of therapy and prior to radiation. Sera and tissue androgen levels were measured by liquid chromatography-tandem mass spectrometry. Results: A total of 22 men with intermediate- (n=3) and high-risk PCa (n=19) received study therapy. Sixteen men completed the intended course of abiraterone, and 19 men completed planned radiation to 77.4 to 81 Gy. Radiation to pelvic nodes was administered in 20 men. The following grade 3 toxicities were reported: lymphopenia (14 patients), fatigue (1 patient), transaminitis (2 patients), hypertension (2 patients), and hypokalemia (1 patient). There were no grade 4 toxicities. All 21 men who complied with at least 3 months of abiraterone therapy had a preradiation prostate-specific antigen (PSA) concentration nadir of <0.3 ng/mL. Median levels of tissue androgen downstream of CYP17A were significantly suppressed after treatment with abiraterone, and upstream steroids were increased. At median follow-up of 21 months (range: 3-37 months), only 1 patient (who had discontinued abiraterone at 3 months) had biochemical relapse. Conclusions: Addition of abiraterone to LHRHa with radiation is safe and achieves effective prostatic androgen suppression. Preliminary analysis of the clinical data is also promising, with excellent PSA nadir and no relapse to date in this high-risk population.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Oxaliplatin–DNA Adducts as Predictive Biomarkers of FOLFOX Response in Colorectal Cancer: A Potential Treatment Optimization Strategy

FOLFOX is one of the most effective treatments for advanced colorectal cancer (CRC). However, cumulative oxaliplatin neurotoxicity often results in halting the therapy. Oxaliplatin functions predominantly via the formation of toxic covalent drug-DNA adducts. We hypothesize that oxaliplatin-DNA adduct levels formed in vivo in peripheral blood mononuclear cells (PBMC) are proportional to tumor shrinkage caused by FOLFOX therapy. We further hypothesize that adducts induced by sub-therapeutic "diagnostic microdoses" are proportional to those induced by therapeutic doses and are also predictive of response to FOLFOX therapy. These hypotheses were tested in CRC cell lines and a pilot clinical study. Four CRC cell lines were cultured with therapeutically relevant (100 µM) or diagnostic microdose (1 µM) concentrations of [ 14 C]oxaliplatin. The C-14 label enabled quantification of oxaliplatin-DNA adduct level with accelerator mass spectrometry (AMS). Oxaliplatin-DNA adduct formation was correlated with oxaliplatin cytotoxicity for each cell line as measured by the MTT viability assay. Six CRC patients received by IV a diagnostic microdose containing [ 14 C]oxaliplatin prior to treatment, as well as a second [ 14 C]oxaliplatin dose during FOLFOX chemotherapy, termed a "therapeutic dose." Oxaliplatin-DNA adduct levels from PBMC correlated significantly to mean tumor volume change of evaluable target lesions (5 of the 6 patients had measurable disease). Finally, oxaliplatin-DNA adduct levels were linearly proportional between microdose and therapeutically relevant concentrations in cell culture experiments and patient samples, as was plasma pharmacokinetics, indicating potential utility of diagnostic microdosing.

60 APPLIED LIFE SCIENCES↗

A Miniature Multilevel Structures for Lossless Ion Manipulations Ion Mobility Spectrometer with Wide Mobility Range Separation Capabilities

Here, ion mobility spectrometry employing structures for lossless ion manipulations (SLIM-IMS) is an attractive gas-phase separation technique due to its ability to achieve unprecedented effective ion path lengths (>1 km) and IMS resolving powers in a small footprint. The emergence of multilevel SLIM technology, where ions are transferred between vertically stacked SLIM electrode surfaces, has subsequently allowed for ultralong single pass path lengths (>40 m) to be achieved, enabling ultrahigh resolution IMS measurements to be performed over the entire mobility range in a single experiment. The implementation of multiple SLIM levels requires very little additional space for the SLIM system, and we developed a miniature SLIM module (miniSLIM) based on multilevel SLIM technology and report the performance here. The module is 11.1 cm x 6.7 cm x 1.4 cm (L x W x H) and consists of three SLIM levels totaling 1-meter path length. Ion trajectory simulations were used to optimize the SLIM board spacings and SLIM board thicknesses of the miniSLIM IMS system. Methods of efficiently transferring ions between SLIM levels were examined and a new approach using asymmetric traveling waves (TWs) was developed and implemented in the miniSLIM. We experimentally characterized the performance of the --meter multilevel miniSLIM IMS-MS relative to a drift tube IM--MS using an Agilent tuning mixture and tetraalkylammonium cations. The 1-meter miniSLIM achieved a resolving power of up to 131 (CCS/ΔCCS), ~1.5x higher than achievable with a 78 cm path length drift tube IMS, and successfully transmitted the entire ion mobility range in a single separation. We also demonstrated the miniSLIM’s performance as a standalone IMS system (i.e., without MS), showing baseline separation between Agilent tuning mixture cations with the full mobility range observed, and a standard peptide mixture with different charge states readily differentiated. Overall the miniSLIM provides a compact alternative to high performance IMS instruments possessing similar path lengths.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrochromic performance of nanocomposite nickel oxide counter electrodes containing lithium and zirconium

Nickel oxide materials are suitable for counter electrodes in complementary electrochromic devices. The state-of-the-art nickel oxide counter electrode materials are typically prepared with multiple additives to enhance peformance. Herein, nanocomposite nickel oxide counter electrodes were fabricated via RF magnetron co-sputtering from Ni-Zr alloy and Li2O ceramic targets. The as-deposited nanocomposite counter electrodes were characterized with inductively coupled plasma mass spectrometry (ICP-MS), scanning electron microscopy (SEM), high-resolution transmission electron microscopy (HRTEM), X-ray diffraction (XRD), and X-ray absorption spectroscopy (XAS). It was found that the stoichiometry, crystal structure and electronic structure of the nickel oxide-based materials could be readily tuned by varying the Li2O sputter deposition power level. Comprehensive electrochromic evaluation demonstrated that the performance of the nickel oxide-based materials was dependent on the overall Li stoichiometry. Overall, the nanocomposite nickel oxide counter electrode containing lithium and zirconium synthesized with a Li2O deposition power of 45 W exhibited the optimal performance with an optical modulation of 71% and coloration efficiency of 30 cm2/C at 670 nm in Li-ion electrolyte.

36 MATERIALS SCIENCE↗

Crystallization and Phase Transformations of Aluminum (Oxy)hydroxide Polymorphs in Caustic Aqueous Solution

Gibbsite, bayerite, and boehmite are important aluminum (oxy)hydroxide minerals in nature and have been widely deployed in various industrial applications. They are also major components in caustic nuclear wastes stored at various U.S. locations. Knowledge of their crystallization and phase transformation processes contributes to understanding their occurrence and could help optimize waste treatment processes. While it has been reported that partial conversion of bayerite and gibbsite to boehmite occurs in basic solutions at elevated temperatures, systematic studies of factors affecting the phase transformation as well as the underlying reaction mechanisms are non-existent, particularly in highly alkaline solutions. We explored the effects of sodium hydroxide concentrations (0.1~3 M), reaction temperature (60~100 ?) and aluminum concentrations (0.1~1 M) on the crystallization and transformation of these aluminum (oxy)hydroxides. Detailed structural and morphological characterization by X-ray diffraction (XRD), scanning electron microscopy (SEM), and nuclear magnetic resonance (NMR) spectrometry revealed that these processes depend largely on the reaction temperature and the Al/OH- ratio. When 1 = Al/OH- = 2.5, the reactions favor formation of high crystallinity precipitates, whereas at Al/OH- ratio ? 2.5 precipitation ceases unless the Al concentration is higher than 1 M. We identified pseudoboehmite, bayerite and gibbsite as intermediate phases to bayerite, gibbsite and boehmite, respectively, all of which transform via dissolution-reprecipitation. Gibbsite transforms to boehmite in both acidic and weak caustic environments at temperatures above 80 oC. However, a ‘bar-shaped’ gibbsite morphology dominates in highly caustic environments (3 M NaOH). The findings enable a robust basis for selection of various solid phases by tuning the reaction conditions.

aluminum (oxy)hydroxide polymorphs, crystallizatio↗

Improving the Molecular Ion Signal Intensity for In Situ Liquid SIMS Analysis

In situ liquid secondary ion mass spectrometry (SIMS) enabled by system for analysis at the liquid vacuum interface (SALVI) has proven to be a promising new tool to provide molecular information at solid–liquid and liquid–vacuum interfaces. However, the initial data showed that useful signals in positive ion spectra are too weak to be meaningful in most cases. In addition, it is difficult to obtain strong negative molecular ion signals when m/z>200. These two drawbacks have been the biggest obstacle towards practical use of this new analytical approach. In this study, we report that strong and reliable positive and negative molecular signals are achievable after optimizing the SIMS experimental conditions. Four model systems, including a 1,8-diazabicycloundec-7-ene (DBU)-base switchable ionic liquid, a live Shewanella oneidensis biofilm, a hydrated mammalian epithelia cell, and an electrolyte popularly used in Li ion batteries were studied. A signal enhancement of about two orders of magnitude was obtained in comparison with non-optimized conditions. Therefore, molecular ion signal intensity has become very acceptable to use for in situ liquid SIMS to study solid–liquid and liquid–vacuum interfaces.

36 MATERIALS SCIENCE↗

Design and Validation of In-Source Atmospheric Pressure Photoionization Hydrogen/Deuterium Exchange Mass Spectrometry with Continuous Feeding of D{sub 2}O

In this study, continuous in-source hydrogen/deuterium exchange (HDX) atmospheric pressure photoionization (APPI) mass spectrometry (MS) with continuous feeding of D{sub 2}O was developed and validated. D{sub 2}O was continuously fed using a capillary line placed on the center of a metal plate positioned between the UV lamp and nebulizer. The proposed system overcomes the limitations of previously reported APPI HDX-MS approaches where deuterated solvents were premixed with sample solutions before ionization. This is particularly important for APPI because solvent composition can greatly influence ionization efficiency as well as the solubility of analytes. The experimental parameters for APPI HDX-MS with continuous feeding of D{sub 2}O were optimized, and the optimized conditions were applied for the analysis of nitrogen-, oxygen-, and sulfur-containing compounds. The developed method was also applied for the analysis of the polar fraction of a petroleum sample. Thus, the data presented in this study clearly show that the proposed HDX approach can serve as an effective analytical tool for the structural analysis of complex mixtures. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗