Search NASA⌕ Search

SEARCH · Search NASA

Results for “structure imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Laser-induced electron diffraction of the ultrafast umbrella motion in ammonia

Visualizing molecular transformations in real-time requires a structural retrieval method with Ångström spatial and femtosecond temporal atomic resolution. Imaging of hydrogen-containing molecules additionally requires an imaging method sensitive to the atomic positions of hydrogen nuclei, with most methods possessing relatively low sensitivity to hydrogen scattering. Laser-induced electron diffraction (LIED) is a table-top technique that can image ultrafast structural changes of gas-phase polyatomic molecules with sub-Ångström and femtosecond spatiotemporal resolution together with relatively high sensitivity to hydrogen scattering. Here, we image the umbrella motion of an isolated ammonia molecule (NH3) following its strong-field ionization. Upon ionization of a neutral ammonia molecule, the ammonia cation (NH3+) undergoes an ultrafast geometrical transformation from a pyramidal (ΦHNH=107°) to planar (ΦHNH=120°) structure in approximately 8 femtoseconds. Using LIED, we retrieve a near-planar (ΦHNH=117 ± 5°) field-dressed NH3+ molecular structure 7.8−9.8 femtoseconds after ionization. Our measured field-dressed NH3+ structure is in excellent agreement with our calculated equilibrium field-dressed structure using quantum chemical ab initio calculations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Imaging of sub-wavelength structures radiating coherently near microspheres

Using a two-dimensional model, we show that the optical images of a sub-wavelength object depend strongly on the excitation of its electromagnetic modes. There exist modes that enable the resolution of the object features smaller than the classical diffraction limit, in particular, due to the destructive interference. We propose to use such modes for super-resolution of resonant structures such as coupled cavities, metal dimers, or bowties. A dielectric microsphere in contact with the object forms its magnified image in a wide range of the virtual image plane positions. It is also suggested that the resonances may significantly affect the resolution quantification in recent experimental studies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sources of and Remedies for Removing Unwanted Reflections in Millimeter Wave Images of Complex SOFI-Covered Structures

In the recent years, continuous-wave (CW) near-field and lens-focused millimeter wave imaging systems have been effectively. used to demonstrate their utility for producing high-resolution images of metallic structures covered with spray on foam insulation (SOFI) such as the space shuttle external tank. These systems have produced images with a spatial resolution of approximately 2 mm at a frequency of 150 GHz, and can easily interrogate thin as well as thick SOFI (> 9") enabling detection and evaluation of flaws such as voids, disbands, delaminations and corrosion. These systems are relatively simple, inexpensive, easy-to-use, require little to no signal processing of the raw data, on-site friendly, real-time and small. However, for some specific structures a certain interference pattern may be superimposed on the produced images. Generally, this occurs when the SOFI surface is at a relatively significant angle with respect to the surface of the substrate (or other sub-structures) on which it is sprayed. Consequently, the reflection from the surface of the SOFI and that from the substrate (or sub-structure) coherently combine into an interference pattern as the SOFI surface is scanned. There are methods by which the influence of this unwanted interference can be reduced, such as the incorporation of an incidence angle and the proper use of signal polarization. This paper presents the basics of this problem and describes the use of the methods for reducing this unwanted influence through several specific examples. A discussion on how the use of a swept-frequency or pulsed method may also alleviate this problem is also presented.

Khakovsky, S.↗

High-Energy Coherent X-Ray Dffraction Microscopy of Polycrystal Grains: First Steps Towards a Multi-Scale Approach

Here, we present proof-of-concept imaging measurements of a polycrystalline material that integrate the elements of conventional high-energy x-ray diffraction microscopy with coherent diffraction-imaging techniques, and that can enable in situ strain-sensitive imaging of lattice structure in ensembles of deeply embedded crystals over five decades of length scale upon full realization. We demonstrate that the combination of these two characterization methods enables a more complete picture of the crystal-lattice strain than either method is capable of providing individually. Such complementary imaging capabilities are critical to addressing questions in a variety of research areas such as materials science and engineering, chemistry, and solid-state physics. Towards this eventual goal, the following key aspects are demonstrated: (1) high-energy Bragg coherent diffraction imaging (HE BCDI) of submicron-scale crystallites at 52 keV at current third-generation synchrotron light sources, (2) HE BCDI performed in conjunction with far-field high-energy diffraction microscopy (FF HEDM) on the grains of a polycrystalline sample in a smoothly integrated manner, and (3) the orientation information of an ensemble of grains obtained via FF HEDM used to perform complementary HE BCDI on multiple Bragg reflections of a single targeted grain. The imaged structures are seen to be 477 ± 50 nm or smaller in size, with an estimated strain resolution of 2.5 x 10 -4 . These steps lay the foundation for integration of HE BCDI, which typically provides a spatial resolution tens of nanometers, into a broad suite of well-established HEDM methods, extending HEDM beyond the few-micrometer resolution bound and into the nanoscale, and positioning the approach to take full advantage of the orders-of-magnitude improvement of x-ray coherence expected at fourth-generation light sources presently being built and commissioned worldwide.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Necessary Experimental Conditions for Single-Shot Diffraction Imaging of DNA-Based Structures with X-ray Free-Electron Lasers

It has been proposed that the radiation damage to biological particles and soft condensed matter can be overcome by ultrafast and ultraintense X-ray free-electron lasers (FELs) with short pulse durations. The successful demonstration of the “diffraction-before-destruction” concept has made single-shot diffraction imaging a promising tool to achieve high resolutions under the native states of samples. However, the resolution is still limited because of the low signal-to-noise ratio, especially for biological specimens such as cells, viruses, and macromolecular particles. Here, we present a demonstration single-shot diffraction imaging experiment of DNA-based structures at SPring-8 Angstrom Compact Free Electron Laser (SACLA), Japan. Through quantitative analysis of the reconstructed images, the scattering abilities of gold and DNA were demonstrated. Suggestions for extracting valid DNA signals from noisy diffraction patterns were also explained and outlined. To sketch out the necessary experimental conditions for the 3D imaging of DNA origami or DNA macromolecular particles, we carried out numerical simulations with practical detector noise and experimental geometry using the Linac Coherent Light Source (LCLS) at the SLAC National Accelerator Laboratory, USA. In conclusion, the simulated results demonstrate that it is possible to capture images of DNA-based structures at high resolutions with the technique development of current and next-generation X-ray FEL facilities.

59 BASIC BIOLOGICAL SCIENCES↗

VERY LARGE TELESCOPE/NACO POLARIMETRIC DIFFERENTIAL IMAGING OF HD100546-DISK STRUCTURE AND DUST GRAIN PROPERTIES BETWEEN 10 AND 140 AU

We present polarimetric differential imaging (PDI) data of the circumstellar disk around the Herbig Ae/Be star HD100546 obtained with Very Large Telescope/NACO. We resolve the disk in polarized light in the H and K{sub s} filter between {approx}0.''1 and 1.''4 (i.e., {approx}10-140 AU). The innermost disk regions are directly imaged for the first time and the mean apparent disk inclination and position angle are derived. The surface brightness along the disk major axis drops off roughly with S(r){proportional_to}r {sup -3} but has a maximum around 0.''15 suggesting a marginal detection of the main disk inner rim at {approx}15 AU. We find a significant brightness asymmetry along the disk minor axis in both filters with the far side of the disk appearing brighter than the near side. This enhanced backward scattering and a low total polarization degree of the scattered disk flux of 14{sup +19}{sub -8}% suggest that the dust grains on the disk surface are larger than typical interstellar medium grains. Empirical scattering functions reveal the backward scattering peak at the largest scattering angles and a second maximum for the smallest scattering angles. This indicates a second dust grain population preferably forward scattering and smaller in size. It shows that, relatively, in the inner disk regions (40-50 AU) a higher fraction of larger grains is found compared to the outer disk regions (100-110 AU). Finally, our images reveal distinct substructures between 25 and 35 AU physical separation from the star and we discuss the possible origin for the two features in the context of ongoing planet formation.

79 ASTRONOMY AND ASTROPHYSICS↗

Imaging X-ray observations and the temperature structure of the Cygnus Loop

Imaging X-ray observations of the northeast portion of the Cygnus Loop (NGC 6992) reveal that X-ray emission extends 5 arc min beyond the optical filaments. Comparison with Fe XIV 5303 forbidden line measurements across the emitting shell is consistent with a temperature gradient across the shell from 10 to the 6.1 K (outside) to 10 to the 6.3 K (inside). Both X-ray and Fe XIV forbidden line intensity and spatial structure can be explained by a Sedov adiabatic blast wave with a shock velocity of 290 plus or minus 15 km/s.

Tuohy, I. R.↗

Correlated 4D-STEM and EDS for the classification of fine Beta-precipitates in aluminum alloy AA 6063-T6

Tuning the properties of aluminum alloys AA 6063-T6 involves artificial aging to induce precipitate formation, particularly β’’ and β’ phases. Previous characterization challenges due to their similar appearance are addressed here by correlating 4D scanning transmission electron microscopy (4DSTEM) and energy-dispersive spectroscopy (EDS) mapping. This approach allows us to analyze the structure and composition of precipitates individually, overcoming limitations of conventional imaging and structural analysis techniques when the precipitates appear simultaneously, as is often the case. We present detailed characterizations of needle-shaped Beta precipitates, revealing distinct diffraction patterns (DPs) and compositional differences. The method's applicability extends beyond aluminum alloys, offering a promising strategy for complex composite material characterization with multimodal scanning transmission electron microscopy (STEM) techniques.

36 MATERIALS SCIENCE↗

Crosswell Imaging Technology & Advanced DSR Navigation for Horizontal Directional Drilling

The objective of Phase II is to develop and demonstrate real-time measurement-while-drilling (MWD) for guidance and navigation of drill strings during horizontal drilling operations applicable to both short and long holes. The end product of Phase II is a functional drill-string assembly outfitted with a commercial version of Drill String Radar (DSR). Project Objectives Develop and demonstrate a dual-phase methodology of in-seam drilling, imaging, and structure confirmation. This methodology, illustrated in Figure 1, includes: (1) Using RIM to image between drill holes for seam thickness estimates and in-seam structures detection. Completed, February 2005; and (2) Using DSR for real-time MWD guidance and navigation of drillstrings during horizontal drilling operations. Completed, November 2008. As of November 2008, the Phase II portion of Contract DE-FC26-04NT42085 is about 99% complete, including milestones and tasks original outlined as Phase II work. The one percent deficiency results from MSHA-related approvals which have yet to be granted (at the time of reporting). These approvals are pending and are do not negatively impact the scope of work or project objectives.

47 OTHER INSTRUMENTATION↗

A design of resonant inelastic X-ray scattering (RIXS) spectrometer for spatial- and time-resolved spectroscopy

The optical design of a Hettrick–Underwood-style soft X-ray spectrometer with Wolter type 1 mirrors is presented. The spectrometer with a nominal length of 3.1 m can achieve a high resolving power (resolving power higher than 10000) in the soft X-ray regime when a small source beam (<3 µm in the grating dispersion direction) and small pixel detector (5 µm effective pixel size) are used. Adding Wolter mirrors to the spectrometer before its dispersive elements can realize the spatial imaging capability, which finds applications in the spectroscopic studies of spatially dependent electronic structures in tandem catalysts, heterostructures, etc . In the pump–probe experiments where the pump beam perturbs the materials followed by the time-delayed probe beam to reveal the transient evolution of electronic structures, the imaging capability of the Wolter mirrors can offer the pixel-equivalent femtosecond time delay between the pump and probe beams when their wavefronts are not collinear. In combination with some special sample handing systems, such as liquid jets and droplets, the imaging capability can also be used to study the time-dependent electronic structure of chemical transformation spanning multiple time domains from microseconds to nanoseconds. The proposed Wolter mirrors can also be adopted to the existing soft X-ray spectrometers that use the Hettrick–Underwood optical scheme, expanding their capabilities in materials research.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ERTS-1 image contributes to understanding of geologic structures related to Managua earthquake, 1972

ERTS-1 imaged the western portion of Nicaragua on December 24, 1972, one day after the central part of the city of Managua was devastated by a major earthquake which measured 5.6 on the Richter scale. ERTS-1 images reveal sets of lineaments (which may reflect fault systems) along any one of which movement could have taken place. One set includes a line of active volcanoes that parallels the coast and constitutes the southwestern edge of the Nicaraguan Depression, a regional graben which cuts obliquely across the Central American isthmus. This trend is offset approximately 10km in a right lateral geometric sense just west of the city of Managua. A parallel lineament, north of Lake Managua, marks the northeast edge of the graben. A second set, extends northward to northwestward from the mouth of the Rio Grande (Viejo) north of Lake Managua and can be projected southward across the lake to Managua. It is this set along which geometric offset of the volcanic lineament appears to have taken place.

Carter, W. D.↗

Geologic Structures in Crater Walls on Vesta

The Framing Camera (FC) on the Dawn spacecraft has imaged most of the illuminated surface of Vesta with a resolution of apporpx. 20 m/pixel through different wavelength filters that allow for identification of lithologic units. The Visible and Infrared Mapping Spectrometer (VIR) has imaged the surface at lower spatial resolution but high spectral resolution from 0.25 to 5 micron that allows for detailed mineralogical interpretation. The FC has imaged geologic structures in the walls of fresh craters and on scarps on the margin of the Rheasilvia basin that consist of cliff-forming, competent units, either as blocks or semi-continuous layers, hundreds of m to km below the rims. Different units have different albedos, FC color ratios and VIR spectral characteristics, and different units can be juxtaposed in individual craters. We will describe different examples of these competent units and present preliminary interpretations of the structures. A common occurrence is of blocks several hundred m in size of high albedo (bright) and low albedo (dark) materials protruding from crater walls. In many examples, dark material deposits lie below coherent bright material blocks. In FC Clementine color ratios, bright material is green indicating deeper 1 m pyroxene absorption band. VIR spectra show these to have deeper and wider 1 and 2 micron pyroxene absorption bands than the average vestan surface. The associated dark material has subdued pyroxene absorption features compared to the average vestan surface. Some dark material deposits are consistent with mixtures of HED materials with carbonaceous chondrites. This would indicate that some dark material deposits in crater walls are megabreccia blocks. The same would hold for bright material blocks found above them. Thus, these are not intact crustal units. Marcia crater is atypical in that the dark material forms a semi-continuous, thin layer immediately below bright material. Bright material occurs as one or more layers. In one region, there is an apparent angular unconformity between the bright material and the dark material where bright material layers appear to be truncated against the underlying dark layer. One crater within the Rheasilvia basin contains two distinct types of bright materials outcropping on its walls, one like that found elsewhere on Vesta and the other an anomalous block ~200 m across. This material has the highest albedo; almost twice that of the vestan average. Unlike all other bright materials, this block has a subdued 1 micron pyroxene absorption band in FC color ratios. These data indicate that this block represents a distinct vestan lithology that is rarely exposed.

Mittlefehldt, David W.↗

Automated 3D cytoplasm segmentation in soft X-ray tomography

Cells’ structure is key to understanding cellular function, diagnostics, and therapy development. Soft X-ray tomography (SXT) is a unique tool to image cellular structure without fixation or labeling at high spatial resolution and throughput. Fast acquisition times increase demand for accelerated image analysis, like segmentation. Currently, segmenting cellular structures is done manually and is a major bottleneck in the SXT data analysis. This paper introduces ACSeg, an automated 3D cytoplasm segmentation model. ACSeg is generated using semi-automated labels and 3D U-Net and is trained on 43 SXT tomograms of immune T cells, rapidly converging to high-accuracy segmentation, therefore reducing time and labor. Furthermore, adding only 6 SXT tomograms of other cell types diversifies the model, showing potential for optimal experimental design. ACSeg successfully segmented unseen tomograms and is published on Biomedisa, enabling high-throughput analysis of cell volume and structure of cytoplasm in diverse cell types.

59 BASIC BIOLOGICAL SCIENCES↗

Structure recognition from high resolution images of ceramic composites

Fibers provide exceptional strength-to-weight ratio capabilities when woven into ceramic composites, transforming them into materials with exceptional resistance to high temperature, and high strength combined with improved fracture toughness. Microcracks are inevitable when the material is under strain, which can be imaged using synchrotron X-ray computed micro-tomography (mu-CT) for assessment of material mechanical toughness variation. An important part of this analysis is to recognize fibrillar features. This paper presents algorithms for detecting and quantifying composite cracks and fiber breaks from high-resolution image stacks. First, we propose recognition algorithms to identify the different structures of the composite, including matrix cracks and fibers breaks. Second, we introduce our package F3D for fast filtering of large 3D imagery, implemented in OpenCL to take advantage of graphic cards. Results show that our algorithms automatically identify micro-damage and that the GPU-based implementation introduced here takes minutes, being 17x faster than similar tools on a typical image file.

36 MATERIALS SCIENCE↗

System and method for improving ultrasound image acquisition and replication for repeatable measurements of vascular structures

High resolution B-mode ultrasound images of the common carotid artery are obtained with an ultrasound transducer using a standardized methodology. Subjects are supine with the head counter-rotated 45 degrees using a head pillow. The jugular vein and carotid artery are located and positioned in a vertical stacked orientation. The transducer is rotated 90 degrees around the centerline of the transverse image of the stacked structure to obtain a longitudinal image while maintaining the vessels in a stacked position. A computerized methodology assists operators to accurately replicate images obtained over several spaced-apart examinations. The methodology utilizes a split-screen display in which the arterial ultrasound image from an earlier examination is displayed on one side of the screen while a real-time live ultrasound image from a current examination is displayed next to the earlier image on the opposite side of the screen. By viewing both images, whether simultaneously or alternately, while manually adjusting the ultrasound transducer, an operator is able to bring into view the real-time image that best matches a selected image from the earlier ultrasound examination. Utilizing this methodology, measurement of vascular dimensions such as carotid arterial IMT and diameter, the coefficient of variation is substantially reduced to values approximating from about 1.0% to about 1.25%. All images contain anatomical landmarks for reproducing probe angulation, including visualization of the carotid bulb, stacking of the jugular vein above the carotid artery, and initial instrumentation settings, used at a baseline measurement are maintained during all follow-up examinations.

Selzer, Robert H.↗

Towards an improved LAI collection protocol via simulated field-based PAR sensing

In support of NASA’s next-generation spectrometer—the Hyperspectral Infrared Imager (HyspIRI)—we are working towards assessing sub-pixel vegetation structure from imaging spectroscopy data. Of particular interest is Leaf Area Index (LAI), which is an informative, yet notoriously challenging parameter to efficiently measure in situ. While photosynthetically-active radiation (PAR) sensors have been validated for measuring crop LAI, there is limited literature on the efficacy of PAR-based LAI measurement in the forest environment. This study (i) validates PAR-based LAI measurement in forest environments, and (ii) proposes a suitable collection protocol, which balances efficiency with measurement variation, e.g., due to sun flecks and various-sized canopy gaps. A synthetic PAR sensor model was developed in the Digital Imaging and Remote Sensing Image Generation (DIRSIG) model and used to validate LAI measurement based on first-principles and explicitly-known leaf geometry. Simulated collection parameters were adjusted to empirically identify optimal collection protocols. Furthermore, these collection protocols were then validated in the field by correlating PAR-based LAI measurement to the normalized difference vegetation index (NDVI) extracted from the “classic” Airborne Visible Infrared Imaging Spectrometer (AVIRIS-C) data (R 2 was 0.61). The results indicate that our proposed collecting protocol is suitable for measuring the LAI of sparse forest (LAI < 3–5 ( m 2 /m 2 )).

47 OTHER INSTRUMENTATION↗

High-Speed X-Ray Stereo Digital Image Correlation in a Shock Tube

X-ray stereo digital image correlation (DIC) measurements were performed at 10 kHz on the internal surface of a jointed structure in a shock tube at a shock Mach number of 1.42 and compared with optical stereo DIC measurements on the outer, visible surface of the structure. The shock tube environment introduces temperature and density gradients in the gas through which the structure was imaged, resulting in spatial and temporal index of refraction variations. These variations cause bias errors in optical DIC measurements due to beam-steering but have minimal influence on x-ray DIC measurements. These results demonstrate the utility of time-resolved x-ray DIC measurements in complicated environments where optical measurements suffer severe errors and/or are precluded by lack of optical access.

42 ENGINEERING↗