Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Elucidating ultrafast electron dynamics at surfaces using extreme ultraviolet (XUV) reflection–absorption spectroscopy

Here we review the recent development of extreme ultraviolet reflection–absorption (XUV-RA) spectroscopy. This method combines the benefits of X-ray absorption spectroscopy, such as element, oxidation, and spin state specificity, with surface sensitivity and ultrafast time resolution, having a probe depth of only a few nm and an instrument response less than 100 fs. Using this technique we investigated the ultrafast electron dynamics at a hematite (α-Fe 2 O 3 ) surface. Surface electron trapping and small polaron formation both occur in 660 fs following photoexcitation. These kinetics are independent of surface morphology indicating that electron trapping is not mediated by defects. Instead, small polaron formation is proposed as the likely driving force for surface electron trapping. We also show that in Fe 2 O 3 , Co 3 O 4 , and NiO, band gap excitation promotes electron transfer from O 2p valence band states to metal 3d conduction band states. In addition to detecting the photoexcited electron at the metal M 2,3 -edge, the valence band hole is directly observed as transient signal at the O L 1 -edge. The size of the resulting charge transfer exciton is on the order of a single metal–oxygen bond length. Spectral shifts at the O L 1 -edge correlate with metal–oxygen bond covalency, confirming the relationship between valence band hybridization and the overpotential for water oxidation. Furthermore, these examples demonstrate the unique ability to measure ultrafast electron dynamics with element and chemical state resolution using XUV-RA spectroscopy. Accordingly, this method is poised to play an important role to reveal chemical details of previously unseen surface electron dynamics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An automated fast neutron computed tomography instrument with on-line focusing for non-destructive evaluation

A fast neutron tomography imaging instrument has been designed, built, and tested at The Ohio State University 500 kW Research Reactor on a fast neutron beamline with a peak neutron flux ≈5.4 × 107 n·cm−2·s−1 at 1.6 MeV median neutron energy. The instrument and beamline are also configurable for thermal neutron imaging. The imaging apparatus is composed of a lens coupled, water-cooled Electron Multiplying Charge Coupled Device camera, a front-surface mirror, and a high light yield plastic Polyvinyl toluene scintillator. The instrument sits on a mobile cart. A total of 5 motion-control stages are built into the system for XYZ and rotational degrees of freedom for sample positioning; the fifth stage fine tunes the focal distance between the camera and the scintillator to achieve on-line focusing. A Python code with a user-friendly graphical user interface controls the fully automated image acquisition, not requiring user interaction, yet facilitating tracking of the image acquisition. A complete fast neutron computed tomography dataset with 360 projections requires less than 3 h, with 30 s per projection. On-line focusing is accomplished with a commercial, off-the-shelf, dielectrically actuated liquid lens. Finally, tomographic reconstructions are visualized using the Livermore Tomography Tools software package. The effective pixel size (width and height) is ≈0.1058 mm, yielding a minimum voxel size of 0.1058 × 0.1058 × 0.1058 mm3, and produces a spatial resolution of 231 μm when calculated from knife-edge measurements.

Bisbee, M. G. (ORCID:0000000313466697)↗

Temperature, Humidity, Wind and Pressure Sensors (THWAPS) Handbook

The temperature, humidity, wind, and pressure system (THWAPS) provide surface reference values of these measurements for balloon-borne sounding system (SONDE) launches. The THWAPS is located adjacent to the SONDE launch site at the Southern Great Plains (SGP) Central Facility. The THWAPS system is a combination of calibration-quality instruments intended to provide accurate measurements of meteorological conditions near the surface. Although the primary use of the system is to provide accurate surface reference values of temperature, pressure, relative humidity (RH), and wind velocity for comparison with radiosonde readings, the system includes a data logger to record time series of the measured variables.

54 ENVIRONMENTAL SCIENCES↗

Probing equilibrium of molecular and deprotonated water on TiO 2 (110)

Significance Understanding how water binds and dissociates on surfaces has broad implications in a vast range of physical and chemical processes. The relative stability of molecularly and dissociatively bound water has been debated for decades on many oxide surfaces, but it has never been successfully measured. Our study describes unique instrumentation, direct measurements, and a state-of-the-art computation and theory approach that yield a detailed kinetic and dynamic description of water deprotonation equilibrium on TiO 2 (110), a prototypical surface commonly used in mechanistic studies of photocatalytic water splitting. This unique study demonstrates that the molecularly bound water on TiO 2 (110) is preferred over the surface-bound hydroxyls by only 0.035 eV.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental Characterization of Photoemission from Plasmonic Nanogroove Arrays

Metal photocathodes are an important source of high-brightness electron beams, ubiquitous in the operation of both large-scale accelerators and table-top microscopes. When the surface of a metal is nanoengineered with patterns on the order of the optical wavelength, it can lead to the excitation and confinement of surface-plasmon-polariton waves that drive nonlinear photoemission. In this work, we aim to evaluate gold plasmonic nanogrooves as a concept for producing bright electron beams for accelerators via nonlinear photoemission. Here, we do this by first comparing their optical properties to numerical calculations from first principles to confirm our ability to fabricate these nanoscale structures. Their nonlinear photoemission yield is found by measuring emitted photocurrent as the intensity of their driving laser is varied. Finally, the mean transverse energy of this electron source is found using the solenoid-scan technique. Our data demonstrate the ability of these cathodes to provide a tenfold enhancement in the efficiency of photoemission over flat metals driven with a linear process. We find that these cathodes are robust and capable of reaching sustained average currents over 100 nA at optical intensities larger than 2 GW cm –2 with no degradation of performance. The emittance of the generated beam is found to be highly asymmetric, a fact we can explain with calculations involving the also asymmetric roughness of the patterned surface. These results demonstrate the use of nanoengineered surfaces as enhanced photocathodes, providing a robust air-stable source of high-average-current electron beams hopefully with great potential for industrial and scientific applications.

47 OTHER INSTRUMENTATION↗

Conceptual Design for SuperCDMS SNOLAB

Beyond the present dark matter direct detection experiment at the Soudan underground laboratory, the SuperCDMS Collaboration is engaged in R and D activities for a 100-kg scale germanium dark matter experiment nominally sited at SNOLAB (2070 m overburden of rock). The expected sensitivity after 3 years of running is 3 x 10{sup -46} cm{sup 2} for the spin-independent cross section, an order of magnitude improvement over present exclusion limits for WIMP masses {approx}80 GeV/c{sup 2}. At this depth, and appropriate design of shielding and cryostat, neutron backgrounds will be negligible. The baseline design is an expanded version of CDMS II with Ge substrates (100 x 33 mm discs) instrumented with the iZIP phonon sensor layout to achieve the electron surface-event rejection power required.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Land-surface studies with a directional neutron detector.

Direct measurements of cosmic-ray neutron intensity were recorded with a neutron scatter camera developed at SNL. The instrument used in this work is a prototype originally designed for nuclear non-proliferation work, but in this project it was used to characterize the response of ambient neutrons in the 0.5-10 MeV range to water located on or above the land surface. Ambient neutron intensity near the land surface responds strongly to the presence of water, suggesting the possibility of an indirect method for monitoring soil water content, snow water equivalent depth, or canopy intercepted water. For environmental measurements the major advantage of measuring neutrons with the scatter camera is the limited (60{sup o}) field of view that can be obtained, which allows observations to be conducted at a previously unattainable spatial scales. This work is intended to provide new measurements of directional fluxes which can be used in the design of new instruments for passively and noninvasively observing land-surface water. Through measurements and neutron transport modeling we have demonstrated that such a technique is feasible.

54 ENVIRONMENTAL SCIENCES↗

Note: A single-chamber tool for plasma activation and surface functionalization in microfabrication

We present a simple apparatus for improved surface modification of polydimethylsiloxane (PDMS) microfluidic devices. A single treatment chamber for plasma activation and chemical/physical vapor deposition steps minimizes the time-dependent degradation of surface activation that is inherent in multi-chamber techniques. Contamination and deposition irregularities are also minimized by conducting plasma activation and treatment phases in the same vacuum environment. An inductively coupled plasma driver allows for interchangeable treatment chambers. Atomic force microscopy confirms that silane deposition on PDMS gives much better surface quality than standard deposition methods, which yield a higher local roughness and pronounced irregularities in the surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Role of chemical production and depositional losses on formaldehyde in the Community Regional Atmospheric Chemistry Multiphase Mechanism (CRACMM)

Abstract. Formaldehyde (HCHO) is an important air pollutant with direct cancer risk and ozone-forming potential. HCHO sources are complex because HCHO is both directly emitted and produced from oxidation of most gas-phase reactive organic carbon. We update the secondary production of HCHO in the Community Regional Atmospheric Chemistry Multiphase Mechanism (CRACMM) in the Community Multiscale Air Quality (CMAQ) model. Production of HCHO from isoprene and monoterpenes is increased, correcting an underestimate in the current version. Simulated June–August surface HCHO during peak photochemical production (11:00–15:00 LT, local time) increased by 0.6 ppb (32 %) over the southeastern USA and by 0.2 ppb (13 %) over the contiguous USA. The increased HCHO compares more favorably with satellite-based observations from the TROPOspheric Monitoring Instrument (TROPOMI) and from aircraft-based observations. Evaluation against hourly surface observations indicates a missing nighttime sink that can be improved by increased nighttime deposition, which reduces June–August nocturnal (20:00–04:00 LT) surface HCHO by 1.1 ppb (36 %) over the southeastern USA and 0.5 ppb (29 %) over the contiguous USA. The ability of CRACMM to capture peak levels of HCHO at midday is improved, particularly at sites in the northeastern USA, while peak levels at sites in the southeastern USA are improved, although still lower than observed. Using established risk assessment methods, lifetime exposure of the population in the contiguous USA (∼ 320 million) to ambient HCHO levels predicted here may result in 6200 lifetime cancer cases, with 40 % from controllable anthropogenic emissions of nitrogen oxides and reactive organic compounds. Chemistry updates will be available in CRACMM version 2 (CRACMM2) in CMAQv5.5.

Skipper, T. Nash↗

dropletProbe Premium v1.201

Selects locations of interest for liquid microjunction surface sampling coupled to a subsequent analysis is done in a user friendly way. That information is then transferred to instrument control softwares. In addition, readout of a laser sensor allows for robust probe-to-surface distance measurement. Furthermore, pictures taken by the software from a camera provides feedback to judge on successful microjunction sampling.

Kertesz, Vilmos↗

Challenges and Capabilities for Inspection of Cast Stainless Steel Piping

Studies conducted at the Pacific N¬orthwest National Laboratory (PNNL) in Richland, Washington, have focused on developing and evaluating the reliability of nondestructive examination (NDE) approaches for inspecting coarse-grained, cast stainless steel reactor components. The objective of this work is to provide information to the United States Nuclear Regulatory Commission (US NRC) on the utility, effec¬tiveness and limitations of NDE techniques as related to the inservice inspec¬tion of primary system piping components in pressurized water reactors (PWRs). This paper describes results from recent assessments built upon early work with low frequency ultrasonic testing (UT) coupled with synthetic aperture focusing technique (SAFT) signal processing, and has subsequently evolved into an approach using low frequency phased array technology as applied from the outer diameter surface of the piping. In addition, eddy current examination as performed from the inner diameter surface of these piping welds is also reported. Cast stainless steel (CSS) pipe specimens were examined that contain thermal and mechanical fatigue cracks located close to the weld roots and have inside/outside surface geometrical conditions that simulate several PWR primary piping weldments and configurations. In addition, segments of vintage centrifugally cast piping were also examined to understand inherent acoustic noise and scattering due to grain structures and determine consistency of UT responses from different locations. The advanced UT methods were applied from the outside surface of these specimens using automated scanning devices and water coupling. The phased array approach was implemented with a modified instrument operating at low frequencies and composite volumetric images of the samples were generated with 500 kHz, 750 kHz, and 1.0 MHz arrays. Eddy current studies were conducted on the inner diameter surface of these piping welds using a commercially available instrument and a cross point probe design operating at a frequency of 250 kHz. Results from the laboratory studies indicate that 500 kHz phased array methods are capable of detecting flaws greater than 30% through-wall in the cast specimens. Length-sizing of flaws is possible, but no diffracted signals could be observed to support time-of-flight depth sizing. The work with eddy current examinations on the inner diameter surface indicate that, while certain cast austenitic microstructures provide excessive background noise due to permeability variations, surface-breaking flaws are quite easily detected. This work was sponsored by the U.S. Nuclear Regulatory Commission under Contract DE-AC06-76RLO 1830; NRC JCN Y6604; Mr. Wallace Norris, NRC Project Monitor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sulfur-induced structural motifs on copper and gold surfaces

The interaction of sulfur with copper and gold surfaces plays a fundamental role in important phenomena that include coarsening of surface nanostructures, and self-assembly of alkanethiols. Here, we identify and analyze unique sulfur-induced structural motifs observed on the low-index surfaces of these two metals. We seek out these structures in an effort to better understand the fundamental interactions between these metals and sulfur that lends to the stability and favorability of metal-sulfur complexes vs. chemisorbed atomic sulfur. The experimental observations presented here—made under identical conditions—together with extensive DFT analyses, allow comparisons and insights into factors that favor the existence of metal-sulfur complexes, vs. chemisorbed atomic sulfur, on metal terraces. We believe this data will be instrumental in better understanding the complex phenomena occurring between the surfaces of coinage metals and sulfur.

36 MATERIALS SCIENCE↗

Strong-coupling quantum dot microscope

Here, we report the development and fabrication of a novel cryogenic instrument, a scanning quantum dot microscope (SQDM), capable of positioning a quantum dot to within tunneling range of a sample surface. The microscope is strong-coupling in the sense that electron wavefunctions in the quantum dot can directly overlap with electron wavefunctions in the sample, in contrast to probes based on electric-field coupling. The SQDM consists of a sharp glass probe with two asymmetric electrodes leading to an aluminum quantum dot at the apex. One electrode is capacitively coupled to the quantum dot, while the other lead is connected to the dot via a tunneling junction. A charge sensing circuit constructed from a high-electron-mobility transistor is attached to the capacitance lead to measure the charge state of the dot. The last key feature of the design is a tilted-apex geometry. This design feature, in conjunction with the capacitive sensing scheme, results in a robust quantum-dot probe capable of operating within angstrom distances of the sample surface while protecting the single tunnel junction responsible for electron transport onto the quantum dot. We demonstrate that our instrument can detect single-electron tunneling events and can also be operated as a standard scanning tunneling microscope capable of nanometer-scale resolution of the surface topography.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fundamental Investigations of Nanoscale Phenomena in Beam-Assisted Nucleation, Growth and Surface Smoothing, Using in situ LEEM

The purposes for which this grant was provided were specifically (1) to construct a tandem instrument that combined a low energy electron microscope (LEEM) with an ion beam source capably of irradiating a sample during observation of the surface using LEEM; and (2) to employ the new machine to whatever degree possible to observe the evolution of clean crystal surfaces during ion beam irradiation. A principal motivation was to investigate the fundamental behavior of radiation damage under circumstances for which the damage can be observed directly in real time as it occurs. A second main motivation was to create tunable perturbations of the defect (adatom and advacancy) equilibrium on clean crystal planes and in this way explore the fundamental kinetics of surface behavior that enters into numerous phenomena of interest to DOE including surface erosion, catalysis, and the damage to crystals caused by impacts of energetic particles. The funding has been employed to successfully pursue all the original goals, and additional opportunities that developed as a result of discoveries made in this research.

36 MATERIALS SCIENCE↗

Advances in understanding the surface chemistry of lignocellulosic biomass via time‐of‐flight secondary ion mass spectrometry

Abstract Overcoming the natural recalcitrance of lignocellulosic biomass is necessary in order to efficiently convert biomass into biofuels or biomaterials and many times this requires some type of chemical pretreatment and/or biological treatment. While bulk chemical analysis is the traditional method of determining the impact a treatment has on biomass, the chemistry on the surface of the sample can differ from the bulk chemistry. Specifically, enzymes and microorganisms bind to the surface of the biomass and their efficiency could be greatly impacted by the chemistry of the surface. Therefore, it is important to study and understand the chemistry of the biomass at the surface. Time‐of‐flight secondary ion mass spectrometry (ToF‐ SIMS ) is a powerful tool that can spectrally and spatially analyze the surface chemistry of a sample. This review discusses the advances in understanding lignocellulosic biomass surface chemistry using the ToF‐ SIMS by addressing the instrument parameters, biomass sample preparation, and characteristic lignocellulosic ion fragmentation peaks along with their typical location in the plant cell wall. The use of the ToF‐ SIMS in detecting chemical changes due to chemical pretreatments, microbial treatments, and physical or genetic modifications is discussed along with possible future applications of the instrument in lignocellulosic biomass studies.

09 BIOMASS FUELS↗

Combining PCA and nonlinear fitting of peak models to re-evaluate C 1s XPS spectrum of cellulose

Cellulose is an example of a material that responds to XPS by the creation of new chemistry not present in the as-received sample. While improvements in instrumentation may be seen in general as beneficial to surface science, recent studies have shown that the consequences for some materials are detrimental. Here, in this work, these problems are illustrated through an analysis of cellulose spectra obtained during a degradation study. C 1s spectra are decomposed into two well-formed component curves that are open to chemical interpretation. In particular, a component-curve representative of pure cellulose is obtained as well as a second component curve that implies cellulose is degraded through the creation of carbon chemistry involving C—O, C$=$O and O—C$=$O. Since cellulose is a crystalline material, formed through the alignment of molecules under the influence of hydrogen bonds, the analysis and findings presented in this paper are relevant to any material analyzed by XPS whose properties are dependent on hydrogen bonds. The analysis techniques are based on an informed vectorial approach, which extracts directly from data spectral shapes that are used to monitor sample degradation via linear least squares optimization. Related mathematics of Principal Component Analysis and linear analysis are presented.

36 MATERIALS SCIENCE↗

Fundamental flow characterization for LiCl–KCl molten salt natural circulation closed loop

Molten salt flow characterization presents numerous challenges due to the hostile environments that cause corrosion and erosion of instrumentation and structural components. To support future molten salt flow characterization under natural convection conditions, a LiCl–KCl eutectic molten salt loop was designed and constructed. The primary objective of this loop is to facilitate natural convection as the principal cooling mechanism, enabling insights into the physics behind natural convection in closed loops and serving as a baseline for loop dimensional and non-dimensional analyses. Here, this study summarizes the fundamental functions employed for flow characterization and introduces a model to estimate flow rate when intrusive instrumentation is unavailable. The approach relies solely on structural surface measurements to avoid flow disturbances. Furthermore, a comprehensive thermal–hydraulic analysis is included to deepen understanding of the system’s behavior.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗