Search NASA⌕ Search

SEARCH · Search NASA

Results for “table detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

HR 7578 - A K dwarf double-lined spectroscopic binary with peculiar abundances

The number of double-lined K and M dwarf binaries which is currently known is quite small, only a dozen or less of each type. The HR 7578 system was classified as dK5 on the Mount Wilson system and as K2 V on the MK ystem. A summary of radial-velocity measurements including the observatory and weight of each observation is given in a table. The star with the stronger lines has been called component A. The final orbital element solution with all observations appropriately weighted was computed with a differential corrections computer program described by Barker et al. (1967). The program had been modified for the double-lined case. Of particular interest are the very large eccentricity of the system and the large minimum masses for each component. These large minimum masses suggest that eclipses may be detectable despite the relatively long period and small radii of the stars.

Fekel, F. C., Jr.↗

Y-12 Groundwater Protection Program Groundwater And Surface Water Sampling And Analysis Plan For Calendar Year 2012

This plan provides a description of the groundwater and surface water quality monitoring activities planned for calendar year (CY) 2012 at the U.S. Department of Energy (DOE) Y-12 National Security Complex (Y-12) that will be managed by the Y-12 Groundwater Protection Program (GWPP). Groundwater and surface water monitoring performed by the GWPP during CY 2012 is in accordance with the following goals: (1) to protect the worker, the public, and the environment; (2) to maintain surveillance of existing and potential groundwater contamination sources; (3) to provide for the early detection of groundwater contamination and determine the quality of groundwater and surface water where contaminants are most likely to migrate beyond the Oak Ridge Reservation property line; (4) to identify and characterize long-term trends in groundwater quality at Y-12; and (5) to provide data to support decisions concerning the management and protection of groundwater resources. Groundwater and surface water monitoring will be performed in three hydrogeologic regimes at Y-12: the Bear Creek Hydrogeologic Regime (Bear Creek Regime), the Upper East Fork Poplar Creek Hydrogeologic Regime (East Fork Regime), and the Chestnut Ridge Hydrogeologic Regime (Chestnut Ridge Regime). The Bear Creek and East Fork regimes are located in Bear Creek Valley and the Chestnut Ridge Regime is located south of Y-12 (Figure A.1). Additional surface water monitoring will be performed north of Pine Ridge along the boundary of the Oak Ridge Reservation. Modifications to the CY 2012 monitoring program may be necessary during implementation. Changes in programmatic requirements may alter the analytes specified for selected monitoring wells or may add or remove wells from the planned monitoring network. Each modification to the monitoring program will be approved by the Y-12 GWPP manager and documented as an addendum to this sampling and analysis plan. The following sections of this report provide details regarding the CY 2012 groundwater and surface water monitoring activities. Section 2 describes the monitoring locations in each regime and the processes used to select the sampling locations. A description of the field measurements and laboratory analytes is provided in Section 3. Sample collection methods and procedures are described in Section 4, and Section 5 lists the documents cited for more detailed operational and technical information. The narrative sections of the report reference several appendices. Figures (maps and diagrams) and tables (excluding a data summary table presented in Section 4) are in Appendix A and Appendix B, respectively. Groundwater Monitoring Schedules (when issued throughout CY 2012) will be inserted in Appendix C, and addenda to this plan (if issued) will be inserted in Appendix D. Laboratory requirements (bottle lists, holding times, etc.) are provided in Appendix E, and an approved Waste Management Plan is provided in Appendix F.

54 ENVIRONMENTAL SCIENCES↗

Robot Acting on Moving Bodies (RAMBO): Interaction with tumbling objects

Interaction with tumbling objects will become more common as human activities in space expand. Attempting to interact with a large complex object translating and rotating in space, a human operator using only his visual and mental capacities may not be able to estimate the object motion, plan actions or control those actions. A robot system (RAMBO) equipped with a camera, which, given a sequence of simple tasks, can perform these tasks on a tumbling object, is being developed. RAMBO is given a complete geometric model of the object. A low level vision module extracts and groups characteristic features in images of the object. The positions of the object are determined in a sequence of images, and a motion estimate of the object is obtained. This motion estimate is used to plan trajectories of the robot tool to relative locations rearby the object sufficient for achieving the tasks. More specifically, low level vision uses parallel algorithms for image enhancement by symmetric nearest neighbor filtering, edge detection by local gradient operators, and corner extraction by sector filtering. The object pose estimation is a Hough transform method accumulating position hypotheses obtained by matching triples of image features (corners) to triples of model features. To maximize computing speed, the estimate of the position in space of a triple of features is obtained by decomposing its perspective view into a product of rotations and a scaled orthographic projection. This allows use of 2-D lookup tables at each stage of the decomposition. The position hypotheses for each possible match of model feature triples and image feature triples are calculated in parallel. Trajectory planning combines heuristic and dynamic programming techniques. Then trajectories are created using dynamic interpolations between initial and goal trajectories. All the parallel algorithms run on a Connection Machine CM-2 with 16K processors.

Davis, Larry S.↗

An overview of the Galileo Optical Experiment (GOPEX)

Uplink optical communication to a deep-space vehicle was demonstrated. In the Galileo Optical Experiment (GOPEX), optical transmissions were beamed to the Galileo spacecraft by Earth-based transmitters at the Table Mountain Facility (TMF), California, and Starfire Optical Range (SOR), New Mexico. The demonstration took place over an eight-day period (9 Dec. through 16 Dec. 1992) as Galileo receded from Earth on its way to Jupiter, and covered ranges from 1-6 million km. At 6 million km (15 times the Earth-Moon distance), the laser beam transmitted from TMF eight days after Earth flyby covered the longest known range for transmission and detection.

Wilson, K. E.↗

Ten Years of Cloud Optical and Microphysical Retrievals from MODIS

The MODIS cloud optical properties algorithm (MOD06/MYD06 for Terra and Aqua MODIS, respectively) has undergone extensive improvements and enhancements since the launch of Terra. These changes have included: improvements in the cloud thermodynamic phase algorithm; substantial changes in the ice cloud light scattering look up tables (LUTs); a clear-sky restoral algorithm for flagging heavy aerosol and sunglint; greatly improved spectral surface albedo maps, including the spectral albedo of snow by ecosystem; inclusion of pixel-level uncertainty estimates for cloud optical thickness, effective radius, and water path derived for three error sources that includes the sensitivity of the retrievals to solar and viewing geometries. To improve overall retrieval quality, we have also implemented cloud edge removal and partly cloudy detection (using MOD35 cloud mask 250m tests), added a supplementary cloud optical thickness and effective radius algorithm over snow and sea ice surfaces and over the ocean, which enables comparison with the "standard" 2.1 11m effective radius retrieval, and added a multi-layer cloud detection algorithm. We will discuss the status of the MOD06 algorithm and show examples of pixellevel (Level-2) cloud retrievals for selected data granules, as well as gridded (Level-3) statistics, notably monthly means and histograms (lD and 2D, with the latter giving correlations between cloud optical thickness and effective radius, and other cloud product pairs).

Platnick, Steven↗

Deep Learning Emulation of Atmospheric Correction for Geostationary Sensors

New generation geostationary satellites make reflectance observations available at a continental scale with unprecedented spatiotemporal resolution and spectral range. Generating Earth monitoring products from these observations requires retrieval of the basic parameter, surface reflectance (SR), by atmospheric correction (AC). Algorithms for atmospheric correction, including Multi-Angle Implementation of Atmospheric Correction (MAIAC), are adapted for each sensor and are too computationally complex to be run in real time, relying instead on look-up tables with precomputed values. Machine learning methods, including convolutional neural networks, have demonstrated performance in learning complex, nonlinear mappings and extracting insight from high-dimensional remote sensing data. In this work, we present a deep learning emulator of MAIAC to retrieve both SR and cloud products. Using this adaptation of deep learning-based emulation to remote sensing, we demonstrate stable SR retrieval over a variety of land covers and viewing conditions and accurate cloud detection. Further, a comparison of computation time suggests emulation as a compelling alternative for expensive physical simulation, especially for applications benefited by near-real time data, such as agricultural management and disaster response.

Duffy, Kate↗

Y-12 Groundwater Protection Program Groundwater And Surface Water Sampling And Analysis Plan For Calendar Year 2010

This plan provides a description of the groundwater and surface water quality monitoring activities planned for calendar year (CY) 2010 at the U.S. Department of Energy (DOE) Y-12 National Security Complex (Y-12) that will be managed by the Y-12 Groundwater Protection Program (GWPP). Groundwater and surface water monitoring performed by the GWPP during CY 2010 will be in accordance with requirements of DOE Order 540.1A and the following goals: (1) to protect the worker, the public, and the environment; (2) to maintain surveillance of existing and potential groundwater contamination sources; (3) to provide for the early detection of groundwater contamination and determine the quality of groundwater and surface water where contaminants are most likely to migrate beyond the Oak Ridge Reservation property line; (4) to identify and characterize long-term trends in groundwater quality at Y-12; and (5) to provide data to support decisions concerning the management and protection of groundwater resources. Groundwater and surface water monitoring during CY 2010 will be performed primarily in three hydrogeologic regimes at Y-12: the Bear Creek Hydrogeologic Regime (Bear Creek Regime), the Upper East Fork Poplar Creek Hydrogeologic Regime (East Fork Regime), and the Chestnut Ridge Hydrogeologic Regime (Chestnut Ridge Regime). The Bear Creek and East Fork regimes are located in Bear Creek Valley, and the Chestnut Ridge Regime is located south of Y-12 (Figure A.1). Additional surface water monitoring will be performed north of Pine Ridge, along the boundary of the Oak Ridge Reservation. Modifications to the CY 2010 monitoring program may be necessary during implementation. Changes in programmatic requirements may alter the analytes specified for selected monitoring wells or may add or remove wells from the planned monitoring network. All modifications to the monitoring program will be approved by the Y-12 GWPP manager and documented as addenda to this sampling and analysis plan. The following sections of this report provide details regarding the CY 2010 groundwater and surface water monitoring activities. Section 2 describes the monitoring locations in each regime and the processes used to select the sampling locations. A description of the field measurements and laboratory analytes is provided in Section 3. Sample collection methods and procedures are described in Section 4, and Section 5 lists the documents cited for more detailed operational and technical information. The narrative sections of the report reference several appendices. Figures (maps and diagrams) and tables (excluding data summary tables presented in the narrative sections) are in Appendix A and Appendix B, respectively. Groundwater Monitoring Schedules (when issued throughout CY 2010) will be inserted in Appendix C, and addenda to this plan (if issued) will be inserted in Appendix D. Laboratory requirements (bottle lists, holding times, etc.) are provided in Appendix E, and an approved Waste Management Plan is provided in Appendix F.

54 ENVIRONMENTAL SCIENCES↗

Computerized quantitative evaluation of mammographic accreditation phantom images

Purpose: The objective was to develop and investigate an automated scoring scheme of the American College of Radiology (ACR) mammographic accreditation phantom (RMI 156, Middleton, WI) images. Methods: The developed method consisted of background subtraction, determination of region of interest, classification of fiber and mass objects by Mahalanobis distance, detection of specks by template matching, and rule-based scoring. Fifty-one phantom images were collected from 51 facilities for this study (one facility provided one image). A medical physicist and two radiologic technologists also scored the images. The human and computerized scores were compared. Results: In terms of meeting the ACR's criteria, the accuracies of the developed method for computerized evaluation of fiber, mass, and speck were 90%, 80%, and 98%, respectively. Contingency table analysis revealed significant association between observer and computer scores for microcalcifications (p<5%) but not for masses and fibers. Conclusions: The developed method may achieve a stable assessment of visibility for test objects in mammographic accreditation phantom image in whether the phantom image meets the ACR's criteria in the evaluation test, although there is room left for improvement in the approach for fiber and mass objects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Robot acting on moving bodies (RAMBO): Preliminary results

A robot system called RAMBO is being developed. It is equipped with a camera, which, given a sequence of simple tasks, can perform these tasks on a moving object. RAMBO is given a complete geometric model of the object. A low level vision module extracts and groups characteristic features in images of the object. The positions of the object are determined in a sequence of images, and a motion estimate of the object is obtained. This motion estimate is used to plan trajectories of the robot tool to relative locations nearby the object sufficient for achieving the tasks. More specifically, low level vision uses parallel algorithms for image enchancement by symmetric nearest neighbor filtering, edge detection by local gradient operators, and corner extraction by sector filtering. The object pose estimation is a Hough transform method accumulating position hypotheses obtained by matching triples of image features (corners) to triples of model features. To maximize computing speed, the estimate of the position in space of a triple of features is obtained by decomposing its perspective view into a product of rotations and a scaled orthographic projection. This allows the use of 2-D lookup tables at each stage of the decomposition. The position hypotheses for each possible match of model feature triples and image feature triples are calculated in parallel. Trajectory planning combines heuristic and dynamic programming techniques. Then trajectories are created using parametric cubic splines between initial and goal trajectories. All the parallel algorithms run on a Connection Machine CM-2 with 16K processors.

Davis, Larry S.↗

Are mildly active galaxies sources of electron-positron annihilation radiation?

Mildly active galaxies are examined as possible sources of 511-keV line radiation resulting from electron-positron annihilations. Observations of seven galaxies of various types are made using an HEAO-3 gamma-ray spectrometer. It is shown that none of the galaxies are detected in the 511 keV line and therefore the proposed scaling law for 511-keV line emission from the galactic nuclei is not valid. The results indicate that the scaling overestimates the 511-keV line flux by a factor of 3 or more. Possible causes of this discrepancy are considered. The expected values of and the observed 2.3-sigma upper limits to the 511-keV line flux for each source and the Galactic Center are presented in a table.

Marscher, A. P.↗

Organic synthesis in the outer Solar System: Recent laboratory simulations for Titan, the Jovian planets, Triton and comets

We tabulate the most abundant gases and their radiation yields, for two experimental pressures: 0.24 mb, more relevant to upper atmosphere excitation, and 17 mb, more relevant to tropospheric, cosmic ray excitation. The yields computed in the 0.24 mb experiment combined with measured electronic fluxes and a simple, eddy diffusion model of Titan's atmosphere predict abundances of detected molecules in agreement with those found by Voyager and for heavier products, in somewhat better agreement with observation than photochemical absolute reaction rate kinetics models. All Voyager organics are accounted for and no detectable products are found that Voyager did not detect. A striking increase of products with multiple bonds is found with decreasing pressure. Hydrocarbon abundances decline slowly with increasing carbon number. Additionally, we list preliminary estimates for the yield of the heteropolymer, which seems to be produced in a quantity comparable (in moles of C+N consumed) to the total amount of gaseous product. The production rate required to sustain Titan's haze against sedimentation also indicates yields of this order. As can be seen from the table, over 10(exp 9) years substantial amounts of these products can accumulate on the surface -- ranging from cm thickness for the (C+N equals 4) species to a meter or more for HCN and C2H2; we also expect a meter or more of tholins. Similar analyses have been or are being done for the Jovian planets and Triton. Charged particle irradiation of hydrocarbon clathrates or mixed hydrocarbon/water ices produces a range of organic products, reddening and darkening of the ices and characteristic infrared spectra. From such spectra, the predicted emission by fine particles in cometary comae well-matches the observed 3.4 micron emission spectra of Comet Halley and other recent comets. Heliocentric evolution of organic emission features in comets is predicted. Organic products of such ice irradiation may account for colors and albedos on some of the satellites in the outer solar system, especially Triton and Pluto, where solid methane is known to exist.

Sagan, C.↗

R-values

I'll try to keep this short and simple. R{sub LANL} = (beta cpm of X{sub exp} on system 'A')/ (beta cpm of {sup 99}Mo{sub exp} on system 'A')/ (beta cpm of X on system 'A', from thermal on {sup 235}U)/ (beta cpm of {sup 99}Mo on system 'A', from thermal on {sup 235}U). As I understand it, the above equation is the historical (as well as current) way of determining R-values using data from beta counting at LANL. The ratio in the denominator, a little 'r', is the 'baseline' or 'calibration' value for a specific beta detector. Over time, if the detector 'drifts' one would see a variation in this 'r' during a thermal calibration measurement. This baseline is what LANL likes to track to monitor specific detector performance - this is not relevant to LLNL where gamma detection is used for determining R-values. LANL states that uncertainty is only dependent upon the count statistics for the isotopes measured. If one tries to convert this to an atom basis, the uncertainties will increase due to the incorporation of the uncertainties in the nuclear data used to convert the cpm to atoms. LLNL switched to gamma detection methods in the 1970s thus replacing our beta counting effort. The equation below is how we have since determined R-values. The numerator ratios atom values of isotopes that are determined by measuring gamma cpm (usually? using several peaks per isotope) and then converting to particle decay in dpm using detector efficiency for each peak and the appropriate branch ratio for each gamma emission. Isotope decay is then converted to atoms using specific activity, mass or volume?, and Avogadro's number. The denominator is simply the ratio of published, cumulative fission product chain yields for isotopes produced in a thermal irradiation on 235U - values of England & Ryder are used by LLNL for the NTNF program. Uncertainties in LLNL R-values are dependent upon gamma counting statistics as well as the nuclear data for each isotope. R{sub LLNL} = (Atoms of X{sub exp})/(Atoms of {sup 99}Mo{sub exp})/(Cumulative Fission Chain Yield of X, from thermal on {sup 235}U)/(Cumulative Fission Chain Yield of {sup 99}Mo, from thermal on {sup 235}U). The next page tabulates fission chain yields and 'atoms per gram' amounts measured in a recent NTNF Thermal Calibration. The R-values in the table are calculated using the LLNL method of determining R. The measure of success is demonstrated by how close to 1.00 the R-value is when determined during a Thermal Calibration. A value of 1.00 is the desired value. In the example below, only four isotopes lie outside of 1.00 by more than 3 percent. These are the four isotopic measurements that obviously need to be improved.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

The elemental and isotopic composition of cosmic rays - Silicon to nickel

The reported observations were made with the aid of the Cosmic Ray Isotope Instrument System (CRISIS) which had been designed to detect and resolve the isotopes of cosmic ray nuclei with atomic numbers equal to or greater than 10. The CRISIS detector was flown on a balloon launched from Aberdeen, South Dakota on 1977 May 20. The period 1977 May 19-22 has been classified by Mason et al. (1979) as one of 'superquiet' solar activity, characterized by the lowest fluxes of low-energy solar particles ever observed. The obtained results are presented in a number of graphs and tables. It was found that the elemental and isotopic abundances of Si are solar-like. Elemental S is underabundant in the cosmic rays by a factor of approximately 3 relative to the solar system, but its isotopic composition resembles the solar composition with S-32 being the dominant isotope. Elemental Ar is virtually absent in the source, and the observed isotopic composition is consistent with a secondary origin. Elemental Ni has a solar-like abundance.

Young, J. S.↗

In-Situ Detection of Process-Induced Porosity During Cure of Out-of-Autoclave Composites

Composite materials offer unique benefits in aerospace applications, including high strength-to-weight ratio, and are becoming increasingly used by industry manufacturers. Current manufacturing and processing methods can lead to defects in the composites, which are identified after fabrication using inspection methods. This study utilized a high-temperature ultrasonic inspection system to detect process-induced porosity in an out-of-autoclave (OOA) composite panel during cure. In order to perform ultrasonic scans in-situ during cure, the system needed to be able to operate at oven temperatures up to 200 °C. There are no commercially available ultrasonic scanning systems that can operate continuously at these temperatures, so an enclosure was fabricated to insulate the ultrasonic system in the curing oven. The enclosure housed a MISTRAS® motorized X-Y raster scanner and contact transducer (Olympus® X2002). The Olympus® X2002 contact transducer is a continuous high-temperature delay line transducer with a center frequency of 2.25 MHz. In order to prevent the inside of the enclosure from reaching high temperatures, a sparge pipe inside the cooling enclosure was connected to a liquid nitrogen (LN2) tank outside of the oven via insulated hoses. The cooling system was automatically controlled by a temperature controller that was programmed to open a solenoid valve along the hose at 31 ℃ and close at 28 ℃ inside the cooling enclosure. When the solenoid valve was open, LN2 would flow from the LN2 tank and vaporize prior to reaching cooling enclosure. A U-shaped sparge pipe had holes drilled along its length to uniformly introduce cold nitrogen gas into the cooling enclosure. This prevented the motors from ever reaching the maximum desired operating temperature of 38 ℃. In the bottom of the enclosure, the tool plate was placed with the composite facing the outside of the enclosure, exposing it to the temperatures of the oven. The tool plate was 63.5 mm thick borosilicate glass, which was chosen for its low ultrasonic attenuation and moderate thermal conductivity. A thin layer of ultrasonic couplant was placed on the tool plate. The transducer sent and received ultrasonic waves through the tool plate into the composite. A MISTRAS® Remote UT System performed all wave generation, analog to digital conversion, and data acquisition and processing. The transducer was connected directly to the Remote UT System via a high-temperature BNC cable (CD International, RG-316). Polyimide insulated copper wire was used to connect the scanner to a 2-axis motor drive, which was connected to the Remote UT System. The motor drive and Remote UT System were located outside the industrial oven. A diagram of the ultrasonic system is shown in Figure 1. Figure 1: Diagram of ultrasonic in-situ defect detection system. In this study, a porosity gradient was introduced into the carbon fiber reinforced polymer (CFRP) composite through a misfit of the part and caul plate. A 24-ply quasi-isotropic ([0/90, ±45]12S) composite panel was laid up using Newport® AS4C-M/NB321 out-of-autoclave (OOA) plain weave (PW) prepreg (42% resin content, 195 g/m2). The first 16 plies were 203 mm × 203 mm. Ply drops were incorporated into the panel by decreasing the length of plies 17-24. The sizes of each ply are included in Table 1. All plies were centered along their length (x-axis) creating a trapezoidal type cross-section. Table 1: Ply sizes Plies Length (mm) Width (mm) 1-16 203 203 17-18 102 203 19-20 85 203 21-22 68 203 23-24 51 203 A 15-5 stainless steel caul plate (Size: 203 × 203 × 1.2 mm) was placed on the laminate. The composite and caul plate were vacuum bagged to the tool plate. Per the product datasheet, Newport 321 can be cured between 121 °C and 149 °C, depending on service temperature, with a hold for 90-120 minutes. Based on prior thermal testing of the cooling enclosure, the desired composite temperature cycle could be attained when the air temperature of the oven was ramped to 160 °C at a rate of 1.7 °C/min with a 3 hour hold. The extended hold was not necessary to cure the composite, but did allow for additional scans at the cure temperature during preliminary testing. The composite panel was under vacuum pressure for the entire cure cycle. Under vacuum, the caul plate deformed causing high and low pressure regions. The low-pressure regions formed high porosity in the composite part. The ultrasonic data collected showed that the inspection system was able to monitor the evolution of porosity within the composite throughout the cure cycle. Fifty scans of a 203 mm × 51 mm (8 in. × 2 in.) area of the composite were completed throughout the cure cycle. The scan speed was set to 43 mm/s in the x-direction and 36 mm/s in the y-direction, with a 1.0 mm/pixel resolution in both directions. Each scan took approximately five minutes to complete. Figure 2 shows C-scan amplitude data (top view) from one scan during the cure cycle. The color map indicates the maximum amplitude (%) measured with a time gate that contains reflections from the back surface (furthest from the transducer in contact with the caul plate) of the composite. Because porosity in the composite increases the ultrasonic attenuation in the composite part, a higher amplitude (red) indicates low porosity and a lower amplitude (blue) indicates high porosity. The regions where the caul plate was applying increased pressure (center and ends of the panel) resulted in reduced porosity, whereas the ply drop regions had reduced pressure and thus had higher porosity. Figure 2: Amplitude C-scan (top view) of OOA composite from one scan during the 160 °C temperature hold. Higher amplitude (red) indicates low porosity. Lower amplitude (blue) indicates high porosity. A B-scan is a two-dimensional image plotting the ultrasonic signals from a single y-position at every x-location of the composite panel. The travel time (μs) of the ultrasonic wave (representing the through-thickness location) is plotted along the y-axis, and the ultrasonic wave signal is represented as a contour map. Based on the B-scan data, the location of the defects with respect to the composite thickness was able to be determined. The ply drop regions had high porosity near the front (tool plate) surface of the composite (Figure 3). Figure 3: B-scan (cross-section view) of OOA composite from one scan during the 160 °C temperature hold. Using the data obtained from amplitude C-scans and B-scans throughout the cure cycle, the high and low porosity regions within the composite laminate were detected and localized with high spatial resolution. This paper will discuss the evolution of porosity content in the OOA composite during cure. OOA tests aided the transition of this system to an autoclave, which is the primary method of curing aerospace-grade thermoset composites.

Tyler B. Hudson↗

Method Development for In Situ Microbiome Profiling of the Water Recovery System’s Wastewater Tank Onboard the International Space Station

A distinctive microbial community has inhabited the International Space Station (ISS) Water Recovery System (WRS) for over 14 years and has experienced the stressors associated with the microgravity environment. The WRS generates potable water for the crew from urine distillate, humidity condensate, Sabatier product water, and the occasional off-loading of ground-supplied water (1). The reservoir for these products, the wastewater tank, does not have a means of microbial control. Current in situ microbial monitoring of the WRS is limited to quarterly culture-based assessments of the potable water product using a microbial capture device and coliform detection bag. Additional analysis of the wastewater and condensate sources are collected into Teflon bags for analysis following return to the ground. The time between sample collection and the return to Earth, as well as the lack of preservation, results in a skewed depiction of the microbiome. Routinely observed from these returned wastewater samples are high counts (105 – 106 colony forming units per mL) and two prevailing genera, Ralstonia and Cupriavidus, as well as a high abundance of unidentified organisms (Table 1). The wastewater tank likely contains a more diverse microbiome, as a higher diversity of bacteria and fungi has been noted upstream and downstream of the tank.

Sarah Stahl-Rommel↗

Historical Bolide Infrasound Dataset (1960–1972)

We present the first fully curated, publicly accessible archive of infrasonic records from ten large bolide events documented by the U.S. Air Force Technical Applications Center’s global microbarometer network between 1960 and 1972. Captured on analog strip-chart paper, these waveforms predate modern digital arrays and space-based sensors, making them a unique window on meteoroid activity in the mid-twentieth century. Prior studies drew important scientific conclusions from the records but released only limited artifacts, chiefly period–amplitude tables and unprocessed scans, leaving the underlying data inaccessible for independent study. The present release transforms those limited excerpts into a research-ready resource. By capturing ten large events in the mid-20th century, the dataset constitutes a critical reference point for assessing bolide activity before the advent of modern space-based and digital ground-based monitoring. The multi-year coverage and worldwide distribution of events provide a valuable reference for comparing past and more recent detections, facilitating assessments of long-term flux and the dynamics of acoustic wave propagation in Earth’s atmosphere. The dataset’s availability in a consolidated format ensures straightforward access to waveforms and derived measurements, supporting a wide range of scientific inquiries into bolide physics and infrasound monitoring. By preserving these historical acoustic observations, the collection maintains a significant record of mid-20th-century meteoroid entries. It thereby establishes a basis for further refinement of impact hazard evaluations, contributes to historical continuity in atmospheric observation, and enriches the study of meteoroid-generated infrasound signals on a global scale.

79 ASTRONOMY AND ASTROPHYSICS↗

Rapid, single-step most-probable-number method for enumerating fecal coliforms in effluents from sewage treatment plants

A single-step most-probable-number method for determining the number of fecal coliform bacteria present in sewage treatment plant effluents is discussed. A single growth medium based on that of Reasoner et al. (1976) and consisting of 5.0 gr. proteose peptone, 3.0 gr. yeast extract, 10.0 gr. lactose, 7.5 gr. NaCl, 0.2 gr. sodium lauryl sulfate, and 0.1 gr. sodium desoxycholate per liter is used. The pH is adjusted to 6.5, and samples are incubated at 44.5 deg C. Bacterial growth is detected either by measuring the increase with time in the electrical impedance ratio between the innoculated sample vial and an uninnoculated reference vial or by visual examination for turbidity. Results obtained by the single-step method for chlorinated and unchlorinated effluent samples are in excellent agreement with those obtained by the standard method. It is suggested that in automated treatment plants impedance ratio data could be automatically matched by computer programs with the appropriate dilution factors and most probable number tables already in the computer memory, with the corresponding result displayed as fecal coliforms per 100 ml of effluent.

Munoz, E. F.↗