Search NASA⌕ Search

SEARCH · Search NASA

Results for “techniques and instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Photonic Integrated Circuit TUned for Reconnaissance and Exploration (PICTURE)

The mid-infrared (MIR) spectral range (3-5 μm) is of particular interest for remotely sensing gaseous molecules such as H2O, CO2, CH4, N2O, CO, NH3, and other compounds. The infrared spectra of planets, moons, comets, and asteroids are rich in information, including gas composition and surface mineralogy. Significant advances in technology have emerged for ground-based telescopes, including the higher spectral resolution permitted by cross-dispersed instruments and heterodyne techniques. New technologies offer the opportunity to break this barrier, by using solid-state photonics. In the past three years, under the NASA ROSES PICASSO program, we have been developing key components for a revolutionary MIR spectrometer: Photonic Integrated Circuit TUned for Reconnaissance and Exploration (PICTURE), which is based on integrated photonics technology that offers ultra-small size, weight, and power (SWaP) with non-moving parts and low cost for future planetary missions. In this paper, we will describe our science and technology development progress leading to demonstrating the concept and functionalities of the PICTURE instrument. The photonic integrated circuit spectrometer (PICS) of the PICTURE instrument uses an integrated heterodyne detection scheme to significantly reduce SWaP and improve sensitivity. Our program goals are to advance the building blocks needed for the PICS, which include arrayed waveguide gratings (AWGs), quantum cascade lasers (QCLs) as local oscillators, and quantum cascade detectors (QCDs) as heterodyne detectors. In addition, we are leveraging a NASA SBIR program to develop the toolsets needed to fabricate MIR photonics lanterns (PL). The PL is a critical component that enables PICTURE to bring a signal from the collecting telescope to the PICS, which requires single optical mode inputs. PICTURE focuses on the CO spectral band at 4.6-4.8 μm that is of key importance to cometary science. We also continue to explore future instrument concepts that exploit the broad wavelength potential of the PICS design to perform spectroscopy spanning the full MIR and longwave IR (LWIR) bands. This will have wide applicability in planetary science, for example, to probe the strongest CO2, H2O, and CH4 transitions that are difficult (CH4) or impossible (CO2, H2O) to detect using Earth-based telescopes due to atmospheric opacity. Each integrated-photonics-spectrometer chip will feature a single heterodyne room-temperature laser with a wide wavelength tuning range, or multiple local-oscillator lasers for much broader spectral coverage. The fully developed PICTURE instrument will provide a cost-effective, high-resolution spectrometer for future space applications.

Anthony W Yu↗

Photonic Integrated Circuit TUned for Reconnaissance and Exploration (PICTURE)

The mid-infrared (MIR) spectral range (3-5 μm) is of particular interest for remotely sensing gaseous molecules such as H2O, CO2, CH4, N2O, CO, NH3, and other compounds. The infrared spectra of planets, moons, comets, and asteroids are rich in information, including gas composition and surface mineralogy. Significant advances in technology have emerged for ground-based telescopes, including the higher spectral resolution permitted by cross-dispersed instruments and heterodyne techniques. New technologies offer the opportunity to break this barrier, by using solid-state photonics. In the past three years, under the NASA ROSES PICASSO program, we have been developing key components for a revolutionary MIR spectrometer: Photonic Integrated Circuit TUned for Reconnaissance and Exploration (PICTURE), which is based on integrated photonics technology that offers ultra-small size, weight, and power (SWaP) with non-moving parts and low cost for future planetary missions. In this paper, we will describe our science and technology development progress leading to demonstrating the concept and functionalities of the PICTURE instrument. The photonic integrated circuit spectrometer (PICS) of the PICTURE instrument uses an integrated heterodyne detection scheme to significantly reduce SWaP and improve sensitivity. Our program goals are to advance the building blocks needed for the PICS, which include arrayed waveguide gratings (AWGs), quantum cascade lasers (QCLs) as local oscillators, and quantum cascade detectors (QCDs) as heterodyne detectors. In addition, we are leveraging a NASA SBIR program to develop the toolsets needed to fabricate MIR photonics lanterns (PL). The PL is a critical component that enables PICTURE to bring a signal from the collecting telescope to the PICS, which requires single optical mode inputs. PICTURE focuses on the CO spectral band at 4.6-4.8 μm that is of key importance to cometary science. We also continue to explore future instrument concepts that exploit the broad wavelength potential of the PICS design to perform spectroscopy spanning the full MIR and longwave IR (LWIR) bands. This will have wide applicability in planetary science, for example, to probe the strongest CO2, H2O, and CH4 transitions that are difficult (CH4) or impossible (CO2, H2O) to detect using Earth-based telescopes due to atmospheric opacity. Each integrated-photonics-spectrometer chip will feature a single heterodyne room-temperature laser with a wide wavelength tuning range, or multiple local-oscillator lasers for much broader spectral coverage. The fully developed PICTURE instrument will provide a cost-effective, high-resolution spectrometer for future space applications.

Anthony W. Yu↗

Self-Sealing Wet Chemistry Cell for Field Analysis

In most analytical investigations, there is a need to process complex field samples for the unique detection of analytes, especially when detecting low concentration organic molecules that may identify extraterrestrial life. Wet chemistry based instruments are the techniques of choice for most laboratory- based analysis of organic molecules due to several factors including less fragmentation of fragile biomarkers, and ability to concentrate target species resulting in much lower limits of detection. Development of an automated wet chemistry preparation system that can operate autonomously on Earth and is also designed to operate under Martian ambient conditions will demonstrate the technical feasibility of including wet chemistry on future missions. An Automated Sample Processing System (ASPS) has recently been developed that receives fines, extracts organics through solvent extraction, processes the extract by removing non-organic soluble species, and delivers sample to multiple instruments for analysis (including for non-organic soluble species). The key to this system is a sample cell that can autonomously function under field conditions. As a result, a self-sealing sample cell was developed that can autonomously hermetically seal fines and powder into a container, regardless of orientation of the apparatus. The cap is designed with a beveled edge, which allows the cap to be self-righted as the capping motor engages. Each cap consists of a C-clip lock ring below a crucible O-ring that is placed into a groove cut into the sample cap.

Beegle, Luther W.↗

Measurement of precipitation induced FUV emission and Geocoronal Lyman Alpha from the IMI mission

This final report describes the activities of the Lockheed Martin Palo Alto Research Laboratory in studying the measurement of ion and electron precipitation induced Far Ultra-Violet (FUV) emissions and Geocoronal Lyman Alpha for the NASA Inner Magnetospheric Imager (IMI) mission. this study examined promising techniques that may allow combining several FUV instruments that would separately measure proton aurora, electron aurora, and geocoronal Lyman alpha into a single instrument operated on a spinning spacecraft. The study consisted of two parts. First, the geocoronal Lyman alpha, proton aurora, and electron aurora emissions were modeled to determine instrument requirements. Second, several promising techniques were investigated to determine if they were suitable for use in an IMI-type mission. Among the techniques investigated were the Hydrogen gas cell for eliminating cold geocoronal Lyman alpha emissions, and a coded aperture spectrometer with sufficient resolution to separate Doppler shifted Lyman alpha components.

Mende, Stephen B.↗

Aeronautic instruments. Section I : general classification of instruments and problems including bibliography

This report is intended as a technical introduction to the series of reports on aeronautic instruments. It presents a discussion of those subjects which are common to all instruments. First, a general classification is given, embracing all types of instruments used in aeronautics. Finally, a classification is given of the various problems confronted by the instrument expert and investigator. In this way the following groups of problems are brought up for consideration: problems of mechanical design, human factor, manufacturing problems, supply and selection of instruments, problems concerning the technique of testing, problems of installation, problems concerning the use of instruments, problems of maintenance, and physical research problems. This enumeration of problems which are common to instruments in general serves to indicate the different points of view which should be kept in mind in approaching the study of any particular instrument.

Hersey, Mayo D↗

Dual technique magnetometer experiment for the Cassini Orbiter spacecraft

The dual technique magnetometer to fly on the Cassini Saturn Orbiter Spacecraft is described. The instrument combines two separate techniques of measuring the magnetic field in space using both fluxgate and vector helium devices. In addition, the instrument can be operated in a special scalar mode which is to be used near the planet for highly accurate determination of the interior field of the planet. As well as the planetary field, the instrument will make large contributions to the scientific measurements of the planetary magnetosphere, the highly electrically conducting region of space surrounding Saturn permeated by the Saturnian field, the interaction of Saturn and the interplanetary medium and the interaction of Titan with its space environment.

Southwood, D. J.↗

In-Lab Rapid Analytical Detection of Lunar Volatiles By Universal Gas Analyzer With Comparison to GC-MS System

Introduction: The curation of permanently shadowed regions (PSRs) [1] on the lunar surface is centered around studies based upon the observed volatiles from the LCROSS mission [2]. The rapid detection of important volatile gases and vapors present in planetary bodies and Astromaterials by a standalone analytical device is an area of intense research interest in our group and Planetary Exploration & Astromaterials Research Laboratory (PEARL) facility and this work is relevant to the future preparation of viable lunar simulants for testing curation efforts down the road. The groundbreaking results obtained from the LCROSS Mission [2] open the requirements for the direct detection of volatiles present in regolith materials collected from the lunar surface. The mass spectrometry of volatile chemicals is a general technique that utilizes a set of instruments that creates charged ions from a gaseous chemical species and measures the intensities vs. mass-to-charge ratio (m/z) [3]. In this context, we discuss in-lab experimental results and procedures for rapid qualitative analysis of main LCROSS volatiles (water, H2S, NH3, CO2, and CH3OH) by a Universal Gas Analyzer (UGA) instrument. Additionally, the instrument performance was evaluated by measuring the isotopic abundance ratio of atmospheric Ar-40 to Ar-36 present in room air since, argon is a relevant gas in planetary studies as it can provide an insight and reference point to isotope studies [4]. Additional, cross comparisons were attempted and made between the two instruments to develop a robust analytical technique by comparing mass spectral data for H2S headspace samples with a Trace-1310/ ISQ 7000 (ThermoFisher Scientific.) GC-MS system. Background: The benchtop UGA System is equipped with an SRS UGA 300 quadrupole mass spectrometer designed and built by Stanford Research Systems [5]. This system can be configured for several types of gaseous chemical analysis. The inlet line continuously samples gases at low flow rates (several milliliters per minute) through a capillary limiting the intake pressure making the instrument ideal for online analysis of select gases and/or room atmosphere. Moreover, in our current UGA system, a change in composition at the inlet can be detected in about 200 milliseconds and a complete spectrum is acquired (for a range of 1-100 amu) in under 45 sec with masses measured at rates up to 25 msec per point [5]. This system provides a quick upstream analytical data that we can then compare to results obtained by our GC-MS system. Sample Preparation: Small volume (2-4 mL) of analyte sample was taken in a 10 mL glass vial and sealed with a crimped cap and purged with pure Ar or N2 gas to displace air from the top. The headspace sample was scanned by the UGA instrument at analog, histogram, and pressure vs. time modes. The isotopic abundance ratio for 40Ar-to-36Ar was estimated by measuring partial pressure vs. time scans and setting the mass at 40 and 36 respectively. Results and Discussions: In this work, we have investigated the applicability of the UGA system by qualitative analysis of a series of LCROSS volatiles measured individually. Fig. 1 demonstrates a set of vertically offset spectra for the partial pressures measured as a function of mass-to-charge (m/z) ratios. The average acquisition time for each spectrum was less than a minute suggesting that the UGA system is ideal for quick analysis of geochemical volatiles. For the cross-comparison, we analyzed an H2S headspace sample by a Trace-1310/ISQ-7000 system and compared mass spectral data with previously measured UGA histogram scan data (Fig. 2). In both cases, major peak positions are the same, however, the intensities of fragment ions ([1H132S]+ and [32S]+) are higher for UGA suggesting that the fragment ionization process is stronger in UGA compared to that of GC-MS. To investigate how the integrated area under each chromatogram varies with the headspace sample volume, a set of five H2S headspace samples with increasing volumes was analyzed by the GC-MS system (Fig. 3, inset). A small volume (e.g., 200 to 1000 µL) of H2S/H2O vapor was withdrawn from a 20 mL stock sample vial containing ~5 mL of 0.4% H2S in water by a gas-tight syringe and added to another 20 mL vial filled with argon and analyzed by the GC-MS system. Finally, the UGA detector sensitivity was evaluated by calculating the atmospheric 40Ar-to-36Ar isotopic abundance ratio in room air by running a partial pressure vs. time scan with setting the atomic mass at 40, and 36. Fig. 4(a) shows a ~25 min duration “P vs. time” scan for 40Ar (plot for 36Ar is not shown). The partial pressure values (~100 points) were corrected by subtracting the corresponding background pressure value for 37Ar and utilized to calculate 40Ar-to-36Ar isotopic abundance ratios as shown by Fig. 4b. The average isotopic abundance ratio is ~306 with a 2*STDEV ~13. This abundance ratio is significantly close to the previously reported value of 298.56 [6] and the ratio obtained by our GC-MS system (303 for a UHP grade Ar sample). Conclusions: Our study strongly evidenced that the benchtop UGA system is a valuable analytical tool for the detection of major LCROSS volatiles. The rapid scanning capability, the inexpensiveness of the whole system, and impressive detection sensitivity prove its worthiness as an essential device for advanced geochemical applications. Moreover, cross comparisons with the GC-MS provide important bridges into advanced curatorial efforts into the future. References: [1] Bickel, V.T., et al. (2021) Nat Commun 12, 5607. [2] Colaprete, A., et al. (2010) Science, 330, 463-468. [3] Glavin, D. P. et al. (2012) 2012 IEEE Aerospace Conference, 1-11. [4] Willett, C. D., et al. (2022) Geochimica et Cosmochimica Acta 329, 119-134. [5] Operation Manual and Programming Reference. (2018) Universal gas Analyzers, Stanford Research Systems. [6] Lee, J. Y., et al. (2006) Geochimica et Cosmochimica Acta 70, 4507–4512. Notes: (4 figures are attached with text as shown by the attached file)

Curation↗

Electronics Systems SRT

Guidance and control systems, communication, data acquisition, instrumentation, and electronics techniques for space application

Source record↗

The program at JPL to investigate the nuclear interaction of RTG's with scientific instruments on deep space probes

A major concern in the integration of a radioisotope thermoelectric generator (RTG) with a spacecraft designed to explore the outer planets is the effect of the emitted radiation on the normal operation of scientific instruments. The necessary techniques and tools developed to allow accurate calculation of the neutron and gamma spectrum emanating from the RTG. The specific sources of radiation were identified and quantified. Monte Carlo techniques are then employed to perform the nuclear transport calculations. The results of these studies are presented. An extensive experimental program was initiated to measure the response of a number of scientific components to the nuclear radiation.

Truscello, V.↗

ADP of multispectral scanner data for land use mapping

The advantages and disadvantages of various remote sensing instrumentation and analysis techniques are reviewed. The use of multispectral scanner data and the automatic data processing techniques are considered. A computer-aided analysis system for remote sensor data is described with emphasis on the image display, statistics processor, wavelength band selection, classification processor, and results display. Advanced techniques in using spectral and temporal data are also considered.

Hoffer, R. M.↗

SMEAT atmosphere trace contaminants.

The atmosphere trace contaminant analysis support provided for the Skylab Medical Experiments Altitude Test (SMEAT) which was conducted from July 26 through September 20, 1972, at the JSC Crew Systems Division facility is discussed. Sample acquisition techniques and analytical instrumentation methodology utilized for identification and quantification of the trace contaminants are described. Emphasis is placed on the contaminants found, their occurrence patterns, and possible sources.

Schornick, J. L.↗

Flight test of a pressurization system used to measure minor atmospheric constituents from an aircraft

A flight evaluation of an ambient air sample pressurization system was conducted at altitudes between 6 and 12 km. The system regulated the sample pressure to 10.15 + or - 0.1 N/sq n and provided sample flow to three gas analysis instruments included in the system. Ozone concentrations measured by two instruments employing different techniques varied from about 30 parts per billion by volume (ppbv) to over 350 ppbv, and the two ozone monitors agreed to within 20 ppbv. A carbon dioxide analyzer indicated modifications required for future installations.

Reck, G. M.↗

Investigations in space-related molecular biology

Improved instrumentation and preparation techniques for high resolution, high voltage cryo-electron microscopic and diffraction studies on terrestrial and extraterrestrial specimens are reported. Computer correlated ultrastructural and biochemical work on hydrated and dried cell membranes and related biological systems provided information on membrane organization, ice crystal formation and ordered water, RNA virus linked to cancer, lunar rock samples, and organometallic superconducting compounds. Apollo 11, 12, 14, and 15 specimens were analyzed

Fernandez-Moran, H.↗