A Generic Framework to Design Perturbation Signals for Parameter Estimation of Dynamic Systems: A Test Case for Inertia Estimation
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
LOS ALAMOS, New Mexico, December 16, 2008—An innovative application of a technology first used for medical imaging may enhance airport security if Los Alamos National Laboratory scientists are successful.
A test procedure to evaluate the performance and health of field installations of grid-connected battery energy storage systems (BESS) is described. Performance and health metrics captured in the procedures are: round-trip efficiency, standby losses, response time/accuracy, and useable energy/state of charge at different discharge/charge rates over the system's lifetime. The procedures are divided into reference performance tests, which require the system to be put in a test mode and are to be conducted in intervals, and real-time monitoring tests, which collect data during normal operation without interruption. The procedures can be applied on a wide array of BESS with little modification and can thus support BESS operators in the management of BESS field installations with minimal interruption and expenditure. Simulated results based on a detailed system simulation of a prototype system are provided as guideline.
The Jefferson Lab LLRF 3.0 system is being developed to replace legacy LLRF systems in the CEBAF accelerator. The new design builds upon 25 years of design and operational RF control experience, and our recent collaboration in the design of the LCLSII LLRF system. The new cavity control algorithm is a fully functional phase and amplitude locked Self Exciting Loop (SEL). This paper discusses the progress of the LLRF 3.0 hardware design, FPGA firmware development, User Datagram Protocol (UDP) operation, and recent LLRF 3.0 system tests on the CEBAF Booster cryomodule in the Upgrade Injector Test Facility (UITF).
The two photocathode test systems were modified, baked and recommissioned. The first system was dedicated to ion studies and the second to electron stimulated recovery (ESR) work. The demonstration system for the electron beam rejuvenation was set up, tested and demonstrated to one of the SSRL team (Dr. Kirby) during a site visit. The requisite subsystems were transferred to SSRL, installed and photoemission studies conducted on activated surfaces following electron beam exposure. Little surface chemistry change was detected in the photoemission spectra following the ESR process. The yield mapping system for the ion (and later, the electron beam rejuvenation) studies was implemented and use made routine. Ion species and flux measurements were performed for H, He, Ne, Ar, Kr and Xe ions at energies of 0.5, 1.0 and 2.0 kV. Gas induced photoyield measurements followed each ion exposure measurement. These data permit the extraction of photoyield induced change per ion (by species) at the measured energies. Electron beam induced rejuvenation was first demonstrated in the second chamber with primary electron beam energy and dependency investigations following. A Hiden quadrupole mass spectrometer for the electron stimulated desorption (ESD) measurements was procured. The UHV test systems needed for subsequent measurements were configured, baked, commissioned and utilized for their intended purposes. Measurements characterizing the desorption products from the ESD process and secondary electron (SE) yield at the surfaces of negative electron affinity GaAs photocathodes have been performed. One US Utility Patent was granted covering the ESR process.
The authors have developed an X-band SRF testing system using a high-Q copper cavity with an interchangeable flat bottom for the testing of different materials. By measuring the Q of the cavity, the system is capable to characterize the quenching magnetic field of the superconducting samples at different power level and temperature, as well as the surface resistivity. This paper presents the most recent development of the system and testing results.
The Regional Test Centers are a group of several sites around the US for testing photovoltaic systems and components related to photovoltaic systems. The RTCs are managed by Sandia National Laboratories. The data collected by the RTCs must be transmitted to Sandia for storage, analysis, and reporting. This document describes the methods that transfer the data between remote sites and Sandia as well as data movement within Sandia’s network. The methods described are in force as of September, 2016.
Small DC-coupled battery test systems are deployed at the National Renewable Energy Laboratory to evaluate capacity fade models and report on performance parameters such as round-trip efficiency under indoor and outdoor deployment scenarios. Initial commercial battery products include LG Chem RESU lithium-ion (Li-ion) and Avalon vanadium redox flow batteries. Adapting indoor lab-scale test methods to outdoor systems has challenges, including maintaining constant temperature and fully controlling batteries through standard discharge curves. Initial measurements show the Li-ion battery systems performing within expectations, near 85% round-trip efficiency. Initial lifetime modeling and measurements indicate that battery capacity could degrade by 20%-35% over 10 years at current rates.
It is presently well understood that the operational performance limits of optics are determined by three fundamental attributes: the initiation of laser-induced damage, the growth of damage sites, and the transient (nondamaging) modification of optical parameters. The comprehensive characterization of the performance limitations of ultrafast optics requires consideration of all three fundamental attributes. Here, the vast majority of literature to date, however, has focused primarily on damage-initiation and testing systems that are largely focused on determining the damage-initiation threshold under single- and multipulse excitation. In this work, we discuss a testing apparatus that was designed to offer the capability to adequately characterize all three of these performance attributes under femtosecond, near-infrared laser irradiation. Key aspects of methodology are discussed, including high-dynamic-range energy control, variable beam size, wavelength tunability, B-integral management, and functional performance characterization to explore the true operational limits of the components. Example results for a metal-dielectric mirror demonstrate the test station’s operation.
The Surveillance and Test System (SATS) checks the functionality of ATR’s Plant Protection System (PPS). The analogue linearity test checks that the SATS analog and digital conversions are accurate to +/- 61 mVdc. This project analyzes whether this accuracy range can be increased without impacting the uncertainty analysis of the PPS system.
Glycolic acid is being evaluated as an alternate reductant in the preparation of high level waste for the Defense Waste Processing Facility (DWPF) at the Savannah River Site (SRS). During processing, the glycolic acid is not completely consumed and small quantities of the glycolate anion are carried forward to other high level waste (HLW) facilities. The impact of the glycolate anion on the corrosion of the materials of construction throughout the waste processing system has not been previously evaluated. A literature review had revealed that corrosion data in glycolate-bearing solution applicable to SRS systems were not available. Therefore, testing was recommended to evaluate the materials of construction of vessels, piping and components within DWPF and downstream facilities. The testing, conducted in non-radioactive simulants, consisted of both accelerated tests (electrochemical and hot-wall) with coupons in laboratory vessels and prototypical tests with coupons immersed in scale-up and mock-up test systems. Eight waste or process streams were identified in which the glycolate anion might impact the performance of the materials of construction. These streams were 70% glycolic acid (DWPF feed vessels and piping), SRAT/SME supernate (Chemical Processing Cell (CPC) vessels and piping), DWPF acidic recycle (DWPF condenser and recycle tanks and piping), basic concentrated recycle (HLW tanks, evaporators, and transfer lines), salt processing (ARP, MCU, and Saltstone tanks and piping), boric acid (MCU separators), and dilute waste (HLW evaporator condensate tanks and transfer line and ETF components). For each stream, high temperature limits and worst-case glycolate concentrations were identified for performing the recommended tests. Test solution chemistries were generally based on analytical results of actual waste samples taken from the various process facilities or of prototypical simulants produced in the laboratory. The materials of construction for most vessels, components and piping were not impacted with the presence of glycolic acid or the impact is not expected to affect the service life. However, the presence of the glycolate anion was found to affect corrosion susceptibility of some materials of construction in the DWPF and downstream facilities, especially at elevated temperatures. The following table summarizes the results of the electrochemical and hot wall testing and indicates expected performance in service with the glycolate anion present.
This project develops an innovative sustainable data evolution technology (SDET) to create open-access power grid datasets and facilitate updates to these datasets by the power grid community. The lack of open-access, realistic large-scale datasets significantly limits the ability of researchers, developers and ultimately end users to develop, benchmark and compare new methods and tools for optimizing the operation and planning of the grid, which leads to slow adoption by end users. Available open datasets include the IEEE sponsored 14-300 bus transmission test cases and distribution test feeders, the Edinburgh Power Systems Test Case Archive (39-2224 buses), and the Polish cases (2383-3375 buses) available with MATPOWER. These datasets serve certain purposes, but for power grid optimization, they are insufficient in one or more of these aspects: 1) they are too small; 2) they are incomplete in both models and scenarios for optimization purposes; and 3) they are static and are not keeping up with grid needs. The SDET technology delivers large-scale realistic datasets and data-creation tools capable of generating new datasets. We work closely with the Category-2 data repository project awarded by the same GRID DATA program. The generated datasets and data creation tools are compatible with and available through the data repository. The objective is to make this a sustained effort within and beyond the ARPA-E GRID DATA program so that the datasets can evolve over time and meet the current and future needs for power grid optimization and potentially other applications in power grid operation and planning. The novel and disruptive features of SDET differentiate itself from prior work in the following aspects: 1) SDET derives features and metrics for both transmission and distribution (T&D) systems by analyzing many public and private datasets provided by our industry partners National Rural Electric Cooperative Association (NRECA) and PJM Interconnection (PJM). 2) SDET develops data-creation tools and use these tools to generate large-scale open-access realistic datasets that comply with the metrics for both T&D systems. 3) SDET validates the created datasets using industry tools provided by our vendor partner GE Energy Solution. The data creation tools, as well as the created datasets, are integrated into the data repository (DR. POWER) funded by ARPA-E GRID DATA program in Category 2. Users can use the datasets and access these data creation tools to create and update datasets, thus datasets can evolve per user requirements and power grid development. The SDET is a novel and disruptive technology compared to current ad hoc and static dataset generation. It is expected the SDET technology will fundamentally enhance the development, assessment, and adoption of new methods and tools for power grid optimization and other applications, which in turn would significantly improve the reliability, resiliency, and efficiency of the power grid – a major ARPA-E mission objective.
Small DC-coupled battery test systems are deployed at NREL to evaluate capacity fade models and report on performance parameters such as round-trip efficiency under indoor and outdoor deployment scenarios. Initial commercial battery products include LG Chem RESU Lithium-ion and Avalon vanadium-redox flow batteries. Adapting indoor lab-scale test methods to outdoor systems has challenges, including maintaining constant temperature and fully controlling batteries through standard discharge curves. Initial measurements show the Lithium Ion battery systems performing within expectation, near 85% round-trip efficiency. Initial lifetime modeling and measurements indicate battery capacity may degrade by 20%-35% over 10 years.
Optimal mitigation planning for highly disruptive contingencies to a transmission-level power system requires optimization with dynamic power system constraints, due to the key role of dynamics in system stability to major perturbations. We formulate a generalized disjunctive program to determine optimal grid component hardening choices for protecting against major failures, with differential algebraic constraints representing system dynamics (specifically, differential equations representing generator and load behavior and algebraic equations representing instantaneous power balance over the transmission system). We optionally allow stochastic optimal pre-positioning across all considered failure scenarios, and optimal emergency control within each scenario. This novel formulation allows, for the first time, analyzing the resilience interdependencies of mitigation planning, preventive control, and emergency control. Using all three strategies in concert is particularly effective at maintaining robust power system operation under severe contingencies, as we demonstrate on the western system coordinating council 9-bus test system using synthetic multi-device outage scenarios.
An expanded plug method was developed earlier for determining the tensile properties of irradiated fuel cladding. This method tests fuel rod cladding ductility by utilizing an expandable plug to radially stretch a small ring of irradiated cladding material. The circumferential or hoop strain is determined from the measured diametrical expansion of the ring. A developed procedure is used to convert the load circumferential strain data from the ring tests into material pseudo-stress-strain curves, from which material properties of the cladding can be extracted. However, several deficiencies existed in this expanded-plug test that can impact the accuracy of test results, such as that the large axial compressive stress resulted from the expansion plug test can potentially induce the shear failure mode of the tested specimen. Moreover, highly nonuniform stress and strain distribution in the deformed clad gage section and significant compressive stresses, induced by bending deformation due to clad bulging effect, will further result in highly nonconservative estimates of the mechanical properties for both strength and ductility of the tested clad. To overcome the aforementioned deficiencies associated with the current expansion plug test, systematic studies have been conducted. By optimizing the specific geometry designs, selecting the appropriate material for the expansion plug, and adding new components into the testing system, a modified expansion plug testing protocol has been developed. A general procedure was also developed to determine the hoop stress in the tested ring specimen. A scaling factor, -factor, was used to convert the ring load Fring into hoop stress , and is written as _ = F_ring/tl , where t is the clad thickness and l is the clad length. The generated stress-strain curve agrees well with the associated tensile test data in both elastic and plastic deformation regions.
Attractive protein-protein interactions (PPI) in concentrated monoclonal antibody (mAb) solutions may lead to reversible oligomers (clusters) that impact colloidal stability and viscosity. Herein, the PPI are tuned for two mAbs via the addition of arginine (Arg), NaCl, or ZnSO 4 as characterized by the structure factor ( S eff (q)) with small angle x-ray scattering (SAXS). The SAXS data are fit with molecular dynamics simulations by placing a physically relevant short-ranged attractive interaction on selected beads in coarse-grained 12 bead models of the mAb shape. The optimized 12-bead models are then used to differentiate key microstructural properties, including center of mass radial distribution functions ( g COM (r)), coordination numbers and cluster size distributions (CSD). The addition of co-solutes results in more attractive Seff(q) relative to the no co-solute control for all systems tested, with the most attractive systems showing an upturn at low q . Only the All1 model with an attractive site in each Fab and Fc region (possessing Fab-Fab, Fab-Fc and Fc-Fc interactions) can reproduce this upturn, and the corresponding CSDs show the presence of larger clusters compared to the control. In general, for models with similar net attractions, i.e., second osmotic virial coefficients, the size of the clusters increases as the attraction is concentrated on a smaller number of evenly distributed beads. Here, the cluster size distributions from simulations are used to improve the understanding and prediction of experimental viscosities. The ability to discriminate between models with bead interactions at particular Fab and Fc bead sites from SAXS simulations, and to provide real space properties (CSD and g COM (r)), will be of interest in engineering protein sequence and formulating protein solutions for weak PPI to minimize aggregation and viscosities.
It is a challenge to generate full charge electrons from the electron sources without compromising polarization for the proposed ILC and CLIC. It is essential to advance polarized photocathodes to meet the requirements. SLAC has worldwide unique dedicated test facilities, Cathode Test System and dc-Gun Test Laboratory, to fully characterize polarized photocathodes. Recent systematic measurements on a strained-well InAlGaAs/AlGaAs cathode at the facilities show that 87% polarization and 0.3% QE are achieved. The QE can be increased to approx1.0% with atomic hydrogen cleaning. The surface charge limit at a very low current intensity and the clear dependence of the polarization on the surface charge limit are observed for the first time. Ongoing programs to develop photocathodes for the ILC and CLIC are briefly introduced.
In this paper, the challenges induced by the integration of inverter-based resources (IBRs) into existing power systems are discussed. Although the grid-forming (GFM) control has been used to enhance system performance in multiple sections of electric power systems (e.g., transmission and distribution systems, microgrids, among others), the coupling mechanism between GFM inverter and various types of other components in modern power systems should be clearly explored. Existing analyses mainly focus on qualitative investigations that verify the effectiveness of deploying GFM inverters for stability enhancement. A holistic system-level quantitative analysis is still missing to verify the detailed benefits of GFM inverters and their interactions with other generation units (e.g., synchronous generators [SGs], conventional grid-following [GFL] inverters, synchronous condensers, among others). To fill in the technical gaps, a holistic small-signal model of the entire system with both rotating generation units and IBRs is established along with the customized power flow analysis for varying steady-state operating points. Further, a quantitative method is proposed to identify the impacts of GFM inverters on system performance with an emphasis on a quantifiable stability margin and a complete modal analysis at the system level. Finally, a realistic test system is used to verify the proposed approach.