Search NASA⌕ Search

SEARCH · Search NASA

Results for “time resolution data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

A new high-speed solar radio spectrograph for meter and decameter wavelengths

The design and characteristics of a high resolution, digital solar spectrograph are discussed. The spectrometer operates in the 10 to 80 MHz range. The primary considerations in the design of the spectrograph were: (1) optimun sensitivity, (2) wide dynamic range, (3) flexibility in time and frequency resolution, and (4) modern data handling techniques with a simple computer interface.

Mosier, S. R.↗

Policy issues and data communications for NASA earth observation missions until 1985

The series of LANDSAT sensors with the highest potential data rates of the missions were examined. An examination of LANDSAT imagery uses shows that relatively few require transmission of the full resolution data on a repetitive quasi real time basis. Accuracy of global crop size forecasting can possibly be improved through information derived from LANDSAT imagery. A current forecasting experiment uses the imagery for crop area estimation only, yield being derived from other data sources.

Corte, A. B.↗

Unprecented syntonization and syncronization accuracy via simultaneous viewing with GPS receivers: Construction characteristics of an NBS/GPS receiver

The National Bureau of Standards/Global Positioning System (NBS/GPS) receiver is discussed. It is designed around the concept of obtaining high accuracy, low cost time and frequency comparisons between remote frequency standards and clocks with the intent to aid international time and frequency coordination. Preliminary tests of this comparison technique between Boulder, CO and Washington, D.C indicate the ability to do accurate time transfer to better that 10 ns, and frequency measurements to better than 1 part in 10 to the 14th power. The hardware and software of the receiver is detailed. The receiver is fully automatic with a built-in 0.1 ns resolution time interval counter. A microprocessor does data processing. Satellite signal stabilities are routinely at the 5 ns level for 15 s averages, and the internal receiver stabilities are at the 1 ns level.

Davis, D. D.↗

Intercomparison of satellite ozone profile measurements

Ozone profile data are intercompared with those from the LIMS and SBUV flown on Nimbus 7, SAGE flown on Atmospheric Explorer Mission 2, and the Ultraviolet and Infrared Spectrometers flown on the SME. Ozone data were derived from the measurements with independently derived processing algorithms. The data cover different time periods and have different spatial and temporal resolutions. The similarities and differences between the individual data sets are determined with effort focused on directly comparing the spacecraft data sets in the form of individual profiles, zonal mean profiles and global analyses. Comparisons with ground data from balloons and Umkehr stations are made.

Fleig, A. J.↗

MECA Workshop on Atmospheric H2O Observations of Earth and Mars. Physical Processes, Measurements and Interpretations

The workshop was held to discuss a variety of questions related to the detection and cycling of atmospheric water. Among the questions addressed were: what factors govern the storage and exchange of water between planetary surfaces and atmospheres; what instruments are best suited for the measurement and mapping of atmospheric water; do regolith sources and sinks of water have uniquely identifiable column abundance signatures; what degree of time and spatial resolution in column abundance data is necessary to determine dynamic behavior. Of special importance is the question, does the understanding of how atmospheric water is cycled on Earth provide any insights for the interpretation of Mars atmospheric data.

Clifford, Stephen M.↗

Analysis of diurnal variation of SCu layer using 2 days of CLASS soundings on San Nicolas Island

Sixty-nine soundings were taken at San Nicolas Island during the FIRE marine stratocumulus experiment. The archived thermodynamic data at 5mb vertical resolution were reduced to 25mb vertical resolution by averaging. Ceilometer data showed the time variation of cloud-base. A subset of 20 soundings taken during a 2 day period of light winds were analyzed. The soundings are grouped into 6 hr. averages (with 5 soundings in each category) to examine the diurnal variation of the thermodynamic structure. Consistent with the solar heating during the daytime, cloud-base rises during the daytime hours and the cloud layer thins. The subcloud layer also becomes more stable, suggesting some uncoupling of the cloud layer from the surface.

Betts, Alan K.↗

Observations of x ray pulsars from the Kvant module

The Roentgen international x ray observatory on the Kvant module of the Mir space station has been successfully operating since the beginning of June 1987. Many x ray sources were observed and among them were several x ray pulsars. Four telescopes mounted on board the Kvant module cover a wide energy range with good timing resolution. Timing analysis of the Kvant module data suffers from the presence of only short continuous intervals of source observations, separated by 90 min gaps (90 min is the orbital period of the Mir space station around the Earth). The presence of 90 min gaps leads to the appearance of beat frequencies v=v sub 0 + or - n/90 min (n = 1, 2, 3). Special analysis was applied to avoid this difficulty. Results are presented of the pulsation period measurements of the x ray pulsars Her X-1, Cen X-3, SMC X-1, Vela X-1, A0535 + 26 by the instruments on board the Kvant module in 1987 to 1989. The values of the periods are reduced to the solar system barycenter and to the binary system barycenter (excluding A0535 + 26).

Gilfanov, M.↗

A wideband channel model for land mobile satellite systems

A wideband channel model for Land Mobile Satellite (LMS) services is presented which characterizes the time-varying transmission channel between a satellite and a mobile user terminal. The channel model statistic parameters are the results of fitting procedures to measured data. The data used for fitting have a time resolution of 33 ns corresponding to a bandwidth of 30 MHz. Thus, the model is capable to characterize the channel behaviour for a wide range of services e.g., voice transmission, digital audio broadcasting (DAB), and spread spectrum modulation schemes. The model is presented for different environments and scenarios. The model is derived for a quasi-mobile user with hand-held terminal being in two different environments: rural and urban. The parameters needed for the description are (a) the number of echoes, (b) the distribution of the echo power, and (c) the distribution of the echo delay. It is shown that the direct path follows a Rician distribution whereas the reflected paths are Rayleigh/lognormal distributed. The parameters are given for an elevation angle of 25 deg.

Jahn, Axel↗

An Assessment of Gigabit Ethernet Technology and Its Applications at the NASA Glenn Research Center

This paper describes Gigabit Ethernet and its role in supporting R&D programs at NASA Glenn. These programs require an advanced high-speed network capable of transporting multimedia traffic, including real-time visualization, high- resolution graphics, and scientific data. GigE is a 1 Gbps extension to 10 and 100 Mbps Ethernet. The IEEE 802.3z and 802.3ab standards define the MAC layer and 1000BASE-X and 1000BASE-T physical layer specifications for GigE. GigE switches and buffered distributors support IEEE 802.3x flow control. The paper also compares GigE with ATM in terms of quality of service, data rate, throughput, scalability, interoperability, network management, and cost of ownership.

Bakes, Catherine Murphy↗

Data center thermal management

Historical high-spatial-resolution temperature data and dynamic temperature sensor measurement data may be used to predict temperature. A first formulation may be derived based on the historical high-spatial-resolution temperature data for determining a temperature at any point in 3-dimensional space. The dynamic temperature sensor measurement data may be calibrated based on the historical high-spatial-resolution temperature data at a corresponding historical time. Sensor temperature data at a plurality of sensor locations may be predicted for a future time based on the calibrated dynamic temperature sensor measurement data. A three-dimensional temperature spatial distribution associated with the future time may be generated based on the forecasted sensor temperature data and the first formulation. The three-dimensional temperature spatial distribution associated with the future time may be projected to a two-dimensional temperature distribution, and temperature in the future time for a selected space location may be forecasted dynamically based on said two-dimensional temperature distribution.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

First GRB detections with the AGILE Minicalorimeter

The Minicalorimeter (MCAL) onboard the AGILE satellite is a 1400 cm{sup 2} scintillation detector sensitive in the energy range 0.3-200 MeV. MCAL works both as a slave of the AGILE Silicon Tracker and as an autonomous detector for transient events (BURST mode). A dedicated onboard Burst Search logic scans BURST mode data in search of count rate increase. Peculiar characteristics of the detector are the high energy spectral coverage and a timing resolution of about 2 microseconds. Even if a trigger is not issued, BURST mode data are used to build a broad band energy spectrum (scientific ratemeters) organized in 11 bands for each of the two MCAL detection planes, with a time resolution of 1 second. After the first engineering commissioning phase, following the AGILE launch on 23rd April 2007, between 22nd June and 5th November 2007 eighteen GRBs were detected offline in the scientific ratemeters data, with a detection rate of about one per week. In this paper the capabilities of the detector will be described and an overview of the first detected GRBs will be given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Resolution Neutron Cross-Section Measurements at the Oak Ridge Electron Linear Accelerator

Over the last three decades, the Oak Ridge Electron Linear Accelerator (ORELA) has produced many neutron-induced cross-section data. ORELA is the only high-power white neutron source with excellent time resolution still operating in the United States and is ideally suited for experiments to measure neutron fission, total, (n,), and capture cross sections in the energy range from 1 eV to as high as several MeV. Recent measurements have included neutron capture measurements on 39,41K, 35,37Cl, F, Mn, 58,60Ni, 53Cr, natural Cr, 48Ti, natural Ti, and 95Mo and total cross-section measurements on natural Cl, natural K, 95Mo, Mn, 53Cr, natural Cr, 48Ti, natural Ti, and 64Zn(n,). Many of these measurements were carried out to support the U.S. Nuclear Criticality Safety Program. Concerns have been raised about many of the older nuclear data evaluations important for criticality safety. For example, the time-of-flight resolution and accuracy of some of the existing data are too poor for new evaluations and thus applications. Several of these data are also important input parameters for the ongoing nuclear astrophysics program, which investigates the s-process nucleosynthesis in asymptotic giant branch stars. Here the Maxwellian-averaged neutron capture cross sections at kT = 8 and 30 keV are of importance. This paper provides an overview of the high-resolution cross-section measurement facility ORELA and describes the current measurement activities.

43 PARTICLE ACCELERATORS↗

Building a Real-Time Flood Prediction Model for Improving Early Warning Systems in Ellicott City, Maryland

As flood events in the United States grow in frequency and intensity, the use of applied remote sensing analyses is increasingly necessary for effective flood monitoring and warning systems. The NASA DEVELOP National Program partnered with the local government of Howard County, Maryland, to investigate the use of machine learning for advanced flood risk detection, and to test the feasibility of integrating this approach into the county’s flood early warning system. To strengthen the efforts of the Howard County Office of Emergency Management (OEM), the project developed a statistical model capable of hindcasting the two severe flash flood events that devastated Ellicott City and transitioned to a ‘Long Short-Term Memory’ based sequence-to-sequence deep learning model with 8-hour forecast capability. The team combined data inputs from public sources including river and precipitation gauges, NASA and NOAA Earth observations, and numerical weather model products using scripts written in the Google Colaboratory Python scripting environment. In addition to designing the deep learning architecture, the team trained and tested the model, and evaluated its performance using Nash-Sutcliffe Efficiency. The final product, the Sequentially Trained Real-time EstimAted Model (STREAM) predicts stage height for the Hudson Branch gauge in Ellicott City using data products available in near real-time, including the High-Resolution Rapid Refresh model’s accumulated precipitation forecasts supplemented by stream gauge data from the OEM and the U.S. Geological Survey. STREAM was incorporated into an online dashboard in a user-friendly interface capable of triggering the alarms that initiate emergency response protocols up to 8 hours in advance of a predicted severe flood event. The project demonstrated the potential for the integration of open data and Earth observations into a flood risk forecasting tool capable of informing near real-time decision making.

NASA DEVELOP↗

THE VELA PULSAR AND ITS LIKELY COUNTER-JET IN THE K{sub s} BAND

We report the first high spatial resolution near-infrared (near-IR) imaging of the Vela pulsar in the K{sub s} band obtained with the new adaptive optics system recently mounted on the Gemini-South telescope. For the first time, we have firmly detected the pulsar in this band with K{sub s} ≈ 21.8 mag, and have resolved in detail an extended feature barely detected previously in the immediate vicinity of the pulsar in the J{sub s}H bands. The pulsar K{sub s} flux is fully consistent with the extension of the flat optical spectrum of the pulsar toward the IR and does not confirm the strong IR flux excess in the pulsar emission suggested earlier by the low spatial resolution data. The extended feature is about two times brighter than the pulsar and is likely associated with its X-ray counter-jet. It extends ∼2'' southward of the pulsar along the X-ray counter-jet and shows knot-like structures and a red spectrum.

79 ASTRONOMY AND ASTROPHYSICS↗

Autonomous plug and play electric vehicle charging scenarios including reactive power provision: a probabilistic load flow analysis

Electric vehicle (EV) charging can have various impacts on low‐voltage distribution systems, along with increasing the uncertainty of network load levels. One method for capturing the statistical uncertainty is probabilistic load flow (PLF). A primary concern of such an approach is determining the correlation between the input variables. Since data are limited, a 1 min resolution bottom‐up time‐variant load model, capturing the changing voltage dependencies of the load, is used for modelling household electrical demand to provide pseudo‐meter data for the three‐phase PLF analysis of a residential distribution network. The correlation between the household and EV charging loads are implicitly taken into account by modelling the EV plug‐in and departure times with the corresponding occupancy model. Two autonomous plug‐and‐play charging scenarios are compared with a standard charging arrangement at both unity and 0.95 capacitive power factors. Four different PLF input correlation scenarios, varying from fully correlated to fully independent, are considered. The proposed charging scenarios and reactive power provision reduce the likelihood of system voltage violations introduced by EVs. The PLF results are verified against those from the initial time‐series analysis providing valuable insight into the uncertainty introduced by EVs and the correlation between household and EV loads.

Melhorn, Alexander C.↗

Characterization of ORNL PSD ASIC

The performance of the ORNL ASIC and its readout system was tested with pixelated organic scintillators. We use a pixelated trans-Stilbene scintillator array from Inrad Optics and a pixelated organic glass scintillator array developed at Sandia National Laboratories to characterize the energy and timing resolutions and the pulse-shape discrimination (PSD) figure-of-merit (FoM). The results are compared to previous work in which the same metrics were measured on waveforms digitized at 250 MHz with 14-bit resolution. We found that the PSD FoM at 340 keVee of the ASIC configuration compared to waveform data varied with the scintillator type. We measured a PSD FoM of 1.12 ± 0.14 with the ASIC configuration versus 1.39 ± 0.23 with waveform data using the trans-Stilbene array. We measured a PSD FoM of 0.52 ± 0.18 with the ASIC configuration versus 1.25 ± 0.19 with waveform data using the the organic glass scintillator array. The coincidence timing resolution was measured using two 6x6x6 mm 3 cubes of trans-Stilbene. It was measured to be 805 ± 9 ps with the ASIC configuration versus 300 ps on average with waveform data.

42 ENGINEERING↗

Imaging MS Methodology for More Chemical Information in Less Data Acquisition Time Utilizing a Hybrid Linear Ion Trap-Orbitrap Mass Spectrometer

A novel mass spectrometric imaging method is developed to reduce the data acquisition time and provide rich chemical information using a hybrid linear ion trap-orbitrap mass spectrometer. In this method, the linear ion trap and orbitrap are used in tandem to reduce the acquisition time by incorporating multiple linear ion trap scans during an orbitrap scan utilizing a spiral raster step plate movement. The data acquisition time was decreased by 43-49% in the current experiment compared to that of orbitrap-only scans; however, 75% or more time could be saved for higher mass resolution and with a higher repetition rate laser. Using this approach, a high spatial resolution of 10 {micro}m was maintained at ion trap imaging, while orbitrap spectra were acquired at a lower spatial resolution, 20-40 {micro}m, all with far less data acquisition time. Furthermore, various MS imaging methods were developed by interspersing MS/MS and MSn ion trap scans during orbitrap scans to provide more analytical information on the sample. This method was applied to differentiate and localize structural isomers of several flavonol glycosides from an Arabidopsis flower petal in which MS/MS, MSn, ion trap, and orbitrap images were all acquired in a single data acquisition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗