Search NASA⌕ Search

SEARCH · Search NASA

Results for “tomography problems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Comparison of radiograph-based texture analysis and bone mineral density with three-dimensional microarchitecture of trabecular bone

Purpose: Hip fracture is a serious health problem and textural methods are being developed to assess bone quality. The authors aimed to perform textural analysis at femur on high-resolution digital radiographs compared to three-dimensional (3D) microarchitecture comparatively to bone mineral density. Methods: Sixteen cadaveric femurs were imaged with an x-ray device using a C-MOS sensor. One 17 mm square region of interest (ROI) was selected in the femoral head (FH) and one in the great trochanter (GT). Two-dimensional (2D) textural features from the co-occurrence matrices were extracted. Site-matched measurements of bone mineral density were performed. Inside each ROI, a 16 mm diameter core was extracted. Apparent density (D{sub app}) and bone volume proportion (BV/TV{sub Arch}) were measured from a defatted bone core using Archimedes' principle. Microcomputed tomography images of the entire length of the core were obtained (Skyscan 1072) at 19.8 {mu}m of resolution and usual 3D morphometric parameters were computed on the binary volume after calibration from BV/TV{sub Arch}. Then, bone surface/bone volume, trabecular thickness, trabecular separation, and trabecular number were obtained by direct methods without model assumption and the structure model index was calculated. Results: In univariate analysis, the correlation coefficients between 2D textural features and 3D morphological parameters reached 0.83 at the FH and 0.79 at the GT. In multivariate canonical correlation analysis, coefficients of the first component reached 0.95 at the FH and 0.88 at the GT. Conclusions: Digital radiographs, widely available and economically viable, are an alternative method for evaluating bone microarchitectural structure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Earthquake Locations

The location of an earthquake is a classic inverse problem. Arrival times of various seismic phases are combined with the location of the instrument to form the data vector. The inverse operator is applied in an iterative manor until the solution converges and the resultant solution is the hypocentral location of the earthquake in space and time. In this presentation, I will present how seismologists obtain local earthquake hypocenters. I will present how the generalized inverse operator is built using the simple distance = rate x time equation and how the inverse operator is used in an iterative manor to converge on the hypocenter of the earthquake. Once an earthquake location is determined, seismologists can then use the location to infer other information about the medium through which the waves traveled. One possible application of the earthquake locations is a branch of seismology known as tomography. In tomography, source and station locations are used to compute the travel times of seismic phases and these phases are then inverted to obtain a velocity model of the medium. Seismic tomography can be applied in both 2-D and 3-D settings and in this presentation, I will present examples from both. The first example comes from a technique known as ambient noise tomography. Rayleigh waves are obtained by cross correlating the background noise between two stations. Because we know the interstation distance between the two stations and the arrival times of the Rayleigh waves, we can use tomography to build a group velocity map of the study region. I will present results from a study of the Eastern Tennessee Seismic Zone using the EarthScope’s Transportable Array together with different seismic networks in the region, figure 1. The second example uses P and S-waves from 412 earthquakes which occurred during the 1994 Draney Peak swarm to calculate a 3-D velocity model of the area. Preliminary results show a strong velocity contrast at a depth of about 4 km where the majority of the earthquakes occur, figure 2.

58 GEOSCIENCES↗

Dynamic in-situ imaging of methane hydrate formation and self-preservation in porous media

Here we present the results of dynamic in-situ 3D X-ray imaging of methane hydrates microstructure during methane hydrate formation and dissociation in sand samples. Short scanning times and high resolution provided by synchrotron X-rays allowed for better understanding of water movement and different types of gas-hydrate formation. Complementing previous observations, we conclude that the process of gas-hydrate formation is accompanied by the water movements caused by cryogenic water suction that happens in sequences of short fast movements with longer equilibrium states in between (when the water is immobile). Based on the 3D microstructure we identified two distinct types of gas-hydrate formation: (i) into the gas pockets and (ii) inside water volumes. For both mechanisms we do not see problems in gas or water supply to support the gas-hydrate formation. The rate of dissociation in the self-preservation mode (pressure drop at negative temperatures) appears to be different for these two types of gas hydrates. This means that the history of the gas-hydrate formation may influence its behaviour at the dissociation stage (e.g. gas-hydrate production).

58 GEOSCIENCES↗

Development of CSG-based radiation shielding module for ARCHER: preliminary results for photons - Paper 126

ARCHER is a parallel Monte Carlo radiation transport code being developed for various hardware platforms including multi-core CPUs, the emerging Nvidia graphics processing units (GPUs) and Intel Xeon Phi coprocessors. Previous studies have demonstrated the accuracy and speed for CT imaging and radiotherapy dosimetry applications. Radiation shielding applications, however, require ARCHER to be more flexible in defining and handling geometries, in addition to the voxel phantom geometries that are commonly used in medical physics calculations. In this paper, we present the development of a general geometry module used for radiation protection and shielding problems in ARCHER. The methods of geometry design and particle transport for the GPUs are introduced. Preliminary results comparing against the MCNP code for cases involving Cs-137 0.662 MeV gammas are reported. The radiation shielding design module of ARCHER has been developed, which supports general geometry setups in the CSG format. The code was implemented using CUDA on Nvidia GPUs, and the performance was benchmarked against the MCNP code for a simple radiation shielding problem. Results showed that ARCHER worked properly and achieved impressive speedup due to highly parallel computing nature of the Nvidia GPUs compared to the MCNP code running on multi-core CPUs. Further optimization of the geometry module will be carried out using advanced geometry structures and variance reduction techniques to improve the precision and performance of ARCHER. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

A Voxel-Based Approach to Explore Local Dose Differences Associated With Radiation-Induced Lung Damage

Purpose: To apply a voxel-based (VB) approach aimed at exploring local dose differences associated with late radiation-induced lung damage (RILD). Methods and Materials: An interinstitutional database of 98 patients who were Hodgkin lymphoma (HL) survivors treated with postchemotherapy supradiaphragmatic radiation therapy was analyzed in the study. Eighteen patients experienced late RILD, classified according to the Radiation Therapy Oncology Group scoring system. Each patient's computed tomographic (CT) scan was normalized to a single reference case anatomy (common coordinate system, CCS) through a log-diffeomorphic approach. The obtained deformation fields were used to map the dose of each patient into the CCS. The coregistration robustness and the dose mapping accuracy were evaluated by geometric and dose scores. Two different statistical mapping schemes for nonparametric multiple permutation inference on dose maps were applied, and the corresponding P<.05 significance lung subregions were generated. A receiver operating characteristic (ROC)-based test was performed on the mean dose extracted from each subregion. Results: The coregistration process resulted in a geometrically robust and accurate dose warping. A significantly higher dose was consistently delivered to RILD patients in voxel clusters near the peripheral medial-basal portion of the lungs. The area under the ROC curves (AUC) from the mean dose of the voxel clusters was higher than the corresponding AUC derived from the total lung mean dose. Conclusions: We implemented a framework including a robust registration process and a VB approach accounting for the multiple comparison problem in dose-response modeling, and applied it to a cohort of HL survivors to explore a local dose–RILD relationship in the lungs. Patients with RILD received a significantly greater dose in parenchymal regions where low doses (∼6 Gy) were delivered. Interestingly, the relation between differences in the high-dose range and RILD seems to lack a clear spatial signature.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiscale evolution of charmed particles in a nuclear medium

Parton energy-momentum exchange with the quark gluon plasma (QGP) is a multiscale problem. In this work, we calculate the interaction of charm quarks with the QGP within the higher twist formalism at high virtuality and high energy using the Modular All Twist Transverse-scattering Elastic-drag and Radiation (MATTER) model, while the low-virtuality and high-energy portion is treated via a linearized Boltzmann transport formalism. Coherence effect that reduces the medium-induced emission rate in the MATTER model is also taken into account through a virtuality-dependent qˆ, leaving the simultaneous dependence of qˆ on heavy quark mass and virtuality for future studies. The interplay between these two formalisms is studied phenomenologically and used to produce a first description of the D-meson and charged hadron nuclear modification factor R AA across multiple centralities. As a result, all calculations were carried out utilizing the Jet Energy-loss Tomography with a Statistically and Computationally Advanced Program Envelope framework.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

TomoTherapy MLC verification using exit detector data

Purpose: Treatment delivery verification (DV) is important in the field of intensity modulated radiation therapy (IMRT). While IMRT and image guided radiation therapy (IGRT), allow us to create more conformal plans and enables the use of tighter margins, an erroneously executed plan can have detrimental effects on the treatment outcome. The purpose of this study is to develop a DV technique to verify TomoTherapy's multileaf collimator (MLC) using the onboard mega-voltage CT detectors. Methods: The proposed DV method uses temporal changes in the MVCT detector signal to predict actual leaf open times delivered on the treatment machine. Penumbra and scattered radiation effects may produce confounding results when determining leaf open times from the raw detector data. To reduce the impact of the effects, an iterative, Richardson-Lucy (R-L) deconvolution algorithm is applied. Optical sensors installed on each MLC leaf are used to verify the accuracy of the DV technique. The robustness of the DV technique is examined by introducing different attenuation materials in the beam. Additionally, the DV technique has been used to investigate several clinical plans which failed to pass delivery quality assurance (DQA) and was successful in identifying MLC timing discrepancies as the root cause. Results: The leaf open time extracted from the exit detector showed good agreement with the optical sensors under a variety of conditions. Detector-measured leaf open times agreed with optical sensor data to within 0.2 ms, and 99% of the results agreed within 8.5 ms. These results changed little when attenuation was added in the beam. For the clinical plans failing DQA, the dose calculated from reconstructed leaf open times played an instrumental role in discovering the root-cause of the problem. Throughout the retrospective study, it is found that the reconstructed dose always agrees with measured doses to within 1%. Conclusions: The exit detectors in the TomoTherapy treatment systems can provide valuable information about MLC behavior during delivery. A technique to estimate the TomoTherapy binary MLC leaf open time from exit detector signals is described. This technique is shown to be both robust and accurate for delivery verification.

60 APPLIED LIFE SCIENCES↗

Case for an Improved Effective-Atomic Number for the Electronic Baggage Scanning Program (Rev. 1)

Z eff , a parameter representing an “effective atomic number” for a material, plays an important role in the Electronic Baggage Scanning Program (EBSP) to detect threats in dual-energy computed tomography (CT) baggage-scanning systems. We believe that Zeff, as defined and used on this program, does not provide the most accurate representation of a material's x-ray properties.. We present the case for a new method that defines an effective atomic number for compounds and mixtures, which we refer to as Z e . Unlike Z eff , Z e is tied by definition to the x-ray absorption properties of each specific material. Use of this alternative will provide a more accurate scale for calibrating LLNL-designed Micro-CT systems and vendor-built Explosives Detection Systems (EDS) against standard reference materials, and it will provide a more accurate physical characterization of the x-ray properties of materials evaluated on those systems. This document, (1) Describes the current usage of the Z eff parameter; (2) Details problems entailed in the use of the Z eff parameter; (3) Proposes a well-defined alternative—Z e ; (4) Proposes and demonstrates an algorithm for optimally associating Z e with any specified compound or mixture; (5) Discusses issues that can impact the usefulness of an effective-Z model; and (6) Recommends that, in order that the chosen effective-Z parameter not materially impact the accuracy of data produced by the EBSP program, the use of Z eff be replaced by Z e .

42 ENGINEERING↗

Machine Learning for Predictive Performance Analysis in Charged Particle Beam Tools

Imaging methods driven by probes, electrons, and ions have played a dominant role in modern science and engineering. Opportunities for machine vision and AI that focus on consumer problems like driving and feature recognition, are now presenting themselves for automating aspects of the scientific processes. This proposal aims to enable and drive discovery in ultra-low energy implantation by taking advantage of faster processing, flexible control and detection methods, and architecture-agnostic workflows that will result in higher efficiency and shorter scientific development cycles. Custom microscope control, collection and analysis hardware will provide a framework for conducting novel in situ experiments revealing unprecedented insight into surface dynamics at the nanoscale. Ion implantation is a key capability for the semiconductor industry. As devices shrink, novel materials enter the manufacturing line, and quantum technologies transition to being more mainstream. Traditional implantation methods fall short in terms of energy, ion species, and positional precision. Here we demonstrate 1 keV focused ion beam Au implantation into Si and validate the results via atom probe tomography. We show the Au implant depth at 1 keV is 0.8 nm and that identical results for low energy ion implants can be achieved by either lowering the column voltage, or decelerating ions using bias – while maintaining a sub-micron beam focus. We compare our experimental results to static calculations using SRIM and dynamic calculations using binary collision approximation codes TRIDYN and IMSIL. A large discrepancy between the static and dynamic simulation is found that is due to lattice enrichment with high stopping power Au and surface sputtering. Additionally, we demonstrate how model details are particularly important to the simulation of these low-energy heavy-ion implantations. Finally, we discuss how our results pave a way to much lower implantation energies, while maintaining high spatial resolution.

47 OTHER INSTRUMENTATION↗

Evaluation of normalized metal artifact reduction (NMAR) in kVCT using MVCT prior images for radiotherapy treatment planning

Purpose: To evaluate the metal artifacts in kilovoltage computed tomography (kVCT) images that are corrected using a normalized metal artifact reduction (NMAR) method with megavoltage CT (MVCT) prior images.Methods: Tissue characterization phantoms containing bilateral steel inserts are used in all experiments. Two MVCT images, one without any metal artifact corrections and the other corrected using a modified iterative maximum likelihood polychromatic algorithm for CT (IMPACT) are translated to pseudo-kVCT images. These are then used as prior images without tissue classification in an NMAR technique for correcting the experimental kVCT image. The IMPACT method in MVCT included an additional model for the pair/triplet production process and the energy dependent response of the MVCT detectors. An experimental kVCT image, without the metal inserts and reconstructed using the filtered back projection (FBP) method, is artificially patched with the known steel inserts to get a reference image. The regular NMAR image containing the steel inserts that uses tissue classified kVCT prior and the NMAR images reconstructed using MVCT priors are compared with the reference image for metal artifact reduction. The Eclipse treatment planning system is used to calculate radiotherapy dose distributions on the corrected images and on the reference image using the Anisotropic Analytical Algorithm with 6 MV parallel opposed 5 × 10 cm{sup 2} fields passing through the bilateral steel inserts, and the results are compared. Gafchromic film is used to measure the actual dose delivered in a plane perpendicular to the beams at the isocenter.Results: The streaking and shading in the NMAR image using tissue classifications are significantly reduced. However, the structures, including metal, are deformed. Some uniform regions appear to have eroded from one side. There is a large variation of attenuation values inside the metal inserts. Similar results are seen in commercially corrected image. Use of MVCT prior images without tissue classification in NMAR significantly reduces these problems. The radiation dose calculated on the reference image is close to the dose measured using the film. Compared to the reference image, the calculated dose difference in the conventional NMAR image, the corrected images using uncorrected MVCT image, and IMPACT corrected MVCT image as priors is ∼15.5%, ∼5%, and ∼2.7%, respectively, at the isocenter.Conclusions: The deformation and erosion of the structures present in regular NMAR corrected images can be largely reduced by using MVCT priors without tissue segmentation. The attenuation value of metal being incorrect, large dose differences relative to the true value can result when using the conventional NMAR image. This difference can be significantly reduced if MVCT images are used as priors. Reduced tissue deformation, better tissue visualization, and correct information about the electron density of the tissues and metals in the artifact corrected images could help delineate the structures better, as well as calculate radiation dose more correctly, thus enhancing the quality of the radiotherapy treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Discrete beta dose kernel matrices for nuclides applied in targeted radionuclide therapy (TRT) calculated with MCNP5

Purpose: Radiopharmaceuticals administered in targeted radionuclide therapy (TRT) rely to a great extent not only on beta-emitting nuclides but also on emitters of monoenergetic electrons. Recent advances like combined PET/CT devices, the consequential coregistration of both data, the concept of using beta couples for diagnosis and therapy, respectively, as well as the development of voxel models offer a great potential for developing TRT dose calculation systems similar to those available for external beam treatment planning. The deterministic algorithms in question for this task are based on the convolution of three-dimensional matrices, one representing the activity distribution and the other the dose point kernel. This study aims to report on three-dimensional kernel matrices for various nuclides used in TRT. Methods: The Monte Carlo code MCNP5 was used to calculate discrete dose kernels of beta particles including the contributions from their respective secondary radiation in soft tissue for the following nuclides: {sup 32}P, {sup 33}P, {sup 67}Cu, {sup 89}Sr, {sup 90}Y, {sup 103}Rh{sup m}, {sup 131}I, {sup 177}Lu, {sup 186}Re, and {sup 188}Re. For each nuclide a kernel cube of 10x10x10 mm{sup 3} was calculated, the dimensions of a voxel being 1 mm{sup 3}. Additional kernels with voxel sizes of 3x3x3 mm{sup 3} were simulated. Results: Comparison with the S-value data regarding {sup 32}P, {sup 89}Sr, {sup 90}Y, and {sup 131}I of the MIRD committee which were calculated with the EGS4 code showed a very good agreement, the secondary particle transport of {sup 90}Y being the only exception. Documented analytical kernels on the other side show deviations very close and very far to the source. Conclusions: The good accordance with the only discrete dose kernels published up to date justifies the method chosen. Together with the additional six nuclides, this report provides a considerable database for three-dimensional kernel matrices with regard to beta radionuclides applied in TRT. In contrast to analytical dose point kernels, the discrete kernels elude the problem of overestimation near the source and take energy depositions into account, which occur beyond the range of the continuous-slowing-down approximation (csda range). Recalculation of the 1x1x1 mm{sup 3} kernels to other dose kernels with varying voxel dimensions, cubic or noncubic, is shown to be easily manageable and thereby provides a resolution-independent system of dose calculation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Baylor University Campus-Wide Deep Dive

In January 2020, staff members from the Engagement and Performance Operations Center (EPOC) and the Lonestar Education And Research Network (LEARN) met with researchers and staff at Baylor University for the purpose of a Campus-Wide Deep Dive into research drivers. The goal of this meeting was to help characterize the requirements for five campus research use cases and to enable cyberinfrastructure support staff to better understand the needs of the researchers they support. Profiled scientific use cases included: - Experimental High Energy Physics (HEP) - Proton Computed Tomography (pCT) - Nutrition and Relation to Digestive Microbiome - Baylor University Core Research Facilities - Molecular Quantum-dot Cellular Automata (QCA), and Material Science of Quantum Computing - Modeling and Simulation of Low-Dimensional and Nano-Structured Materials - Computational Fluid Dynamics Material for this event included the written documentation from each of the research areas at Baylor University, documentation about the current state of technology support, and a write-up of the discussion that took place in person. The Case Studies highlighted the ongoing challenges that Baylor University has in supporting a cross-section of established and emerging research use cases. Each Case Study mentioned unique challenges which were summarized into common needs. These included: - Tradeoffs for network/software security, and usability of the resulting infrastructure. Better communication to set expectations and understand realities is required. - Computation use on campus is widespread and healthy. While no major problems were uncovered, upgrades to maintain current usage patterns and encourage growth will be required. - Storage is a critical need for enterprise use cases and research. In particular, a campus wide ‘storage architecture’ to support research use cases (e.g. instruments, data sharing) is required in the 2-5 year time window. - Instrumentation on campus is healthy and expanding. Technology must scale with this in the form of computation and storage. - Working with LEARN to upgrade network capacity (in multiples of 10G, or upgrades to 100G) will be required in the 1-3 year time frame. - Network monitoring and visibility will help to establish external science use cases. - Data sharing via portal systems is not currently a critical need, but growing in scope. EPOC can assist Baylor with options.

99 GENERAL AND MISCELLANEOUS↗

SQMS Quantum R&D in Machine Learning, Optimization and Sensing beyond Fundamental Physics Applications

This newly formed team at SQMS under the Ecosystem Thrust is looking to develop capabilities impacting societal advances outside the core domain of HEP and condensed matter physics. We explicitly leverage the experimental and algorithmic innovations developed across all groups as well as connect to broad-scope external projects of the diverse team of PIs. As the inaugural set of projects, we are studying numerically quantum machine learning models inspired by efficiently trainable echo-state and orthogonal neural networks and developing designs for related experiments to be performed on quantum processors based on SQMS SRF cQED technology and Rigetti s transmon arrays. Investigated models exploit ideas and lessons learned from multiple prior work by SQMS team members in a variety of internal and external activities [R1]. Target initial applications include noisy signal processing, potentially captured by quantum sensors or noisy QPUs, as well as simulation and classification of healthcare data. For instance, image reconstruction of the brain s electrical properties by solving the inverse Maxwell equation problem with uncertainty [R2] through a hybrid quantum-classical physics-informed architecture for time-dependent processes [R3]. The group is also investigating the application and development of novel quantum sensors based on magnetic levitation of a superconducting sphere coupled to a superconducting qubit. This coupling enables high-precision measurements of the position of the sphere, which can be used for sensitive detection of forces, enabling practical applications such as gravimetry for geophysics analysis, or accelerometry for GPS-denied navigation [R4] [R1] Rieffel, Eleanor G., Ata Akbari Asanjan, M. Sohaib Alam, Namit Anand, David E. Bernal Neira, Sophie Block, Lucas T. Brady et al. "Assessing and advancing the potential of quantum computing: A NASA case study." Future Generation Computer Systems (2024). [R2] Yu, X., Serrall s, J.E., Giannakopoulos, I.I., Liu, Z., Daniel, L., Lattanzi, R. and Zhang, Z., 2023. Pifon-ept: Mr-based electrical property tomography using physics-informed fourier networks. IEEE Journal on Multiscale and Multiphysics Computational Techniques. [R3] Wudarski, Filip, Daniel OConnor, Shaun Geaney, Ata Akbari Asanjan, Max Wilson, Elena Strbac, P. Aaron Lott, and Davide Venturelli. "Hybrid quantum-classical reservoir computing for simulating chaotic systems." arXiv preprint arXiv:2311.14105 (2023). [R4] Higgins, Gerard, Saarik Kalia, and Zhen Liu. "Maglev for dark matter: Dark-photon and axion dark matter sensing with levitated superconductors." Physical Review D 109.5 (2024): 055024.

Venturelli, Davide↗

SU-E-T-164: Characterization of Breast Deformation During Accuboost TM Treatment

Purpose: During treatment using AccuboostTM (Advanced Radiation Therapy, Tyngsboro, MA) applicators the breast is compressed between two paddles in order to immobilize it. This causes the breast tissue to expand. The purpose of this study was to analyze the nature of this deformation. Methods: CT scans of a breast phantom (Computerized Imaging Reference Systems, Norfolk, VA) were acquired at different compressions in the cranial-caudal (CC) direction. These were performed by placing the phantom between two plates whose position is controlled by a manual crank. The phantom masses were contoured in order to simulate the clips placed after surgery. For all scans the mean distance between the masses was computed. Additionally, deformable registration was performed between two scans using the Velocity software (Varian Medical Systems, Palo Alto, CA) to assess the shifts of each of these masses. Results: As the compression increases so does the average distance between the masses. The relationship between deformation and compression is not linear. Additionally, the largest displacements are in the direction of compression. The mean shift is 1.8mm. The shifts in the RT-LT direction and ANT-POST direction are 1.1 mm and 0.7 mm respectively Conclusion: When treating patients the clips shift their position as a Result of the plate compression. For CC compressions this is not a problem if they shift their position primarily in the superior-inferior direction. The problem of not being able to cover all clips (target area) can arise when they shift position on a plane perpendicular to the patient. For clips which are already near the chest wall, care should be exercised not to compress the breast in such a way as to move those clips out of the treatable area.These preliminary results show a larger shift in the RT-LT direction than the ANT-POST one. Further research will seek to either confirm or infirm this.

60 APPLIED LIFE SCIENCES↗

Elucidating the Onset of Plasticity in Sliding Contacts Using Differential Computational Orientation Tomography

Abstract Depending on the mechanical and thermal energy introduced to a dry sliding interface, the near-surface regions of the mated bodies may undergo plastic deformation. In this work, we use large-scale molecular dynamics simulations to generate “differential computational orientation tomographs” (dCOT) and thus highlight changes to the microstructure near tribological FCC alloy surfaces, allowing us to detect subtle differences in lattice orientation and small distances in grain boundary migration. The analysis approach compares computationally generated orientation tomographs with their undeformed counterparts via a simple image analysis filter. We use our visualization method to discuss the acting microstructural mechanisms in a load- and time-resolved fashion, focusing on sliding conditions that lead to twinning, partial lattice rotation, and grain boundary-dominated processes. Extracting and laterally averaging the color saturation value of the generated tomographs allows us to produce quantitative time- and depth-resolved maps that give a good overview of the progress and severity of near-surface deformation. Corresponding maps of the lateral standard deviation in the color saturation show evidence of homogenization processes occurring in the tribologically loaded microstructure, frequently leading to the formation of a well-defined separation between deformed and undeformed regions. When integrated into a computational materials engineering framework, our approach could help optimize material design for tribological and other deformation problems. Graphic Abstract .

36 MATERIALS SCIENCE↗

Four-dimensional cone beam CT reconstruction and enhancement using a temporal nonlocal means method

Purpose: Four-dimensional cone beam computed tomography (4D-CBCT) has been developed to provide respiratory phase-resolved volumetric imaging in image guided radiation therapy. Conventionally, it is reconstructed by first sorting the x-ray projections into multiple respiratory phase bins according to a breathing signal extracted either from the projection images or some external surrogates, and then reconstructing a 3D CBCT image in each phase bin independently using FDK algorithm. This method requires adequate number of projections for each phase, which can be achieved using a low gantry rotation or multiple gantry rotations. Inadequate number of projections in each phase bin results in low quality 4D-CBCT images with obvious streaking artifacts. 4D-CBCT images at different breathing phases share a lot of redundant information, because they represent the same anatomy captured at slightly different temporal points. Taking this redundancy along the temporal dimension into account can in principle facilitate the reconstruction in the situation of inadequate number of projection images. In this work, the authors propose two novel 4D-CBCT algorithms: an iterative reconstruction algorithm and an enhancement algorithm, utilizing a temporal nonlocal means (TNLM) method. Methods: The authors define a TNLM energy term for a given set of 4D-CBCT images. Minimization of this term favors those 4D-CBCT images such that any anatomical features at one spatial point at one phase can be found in a nearby spatial point at neighboring phases. 4D-CBCT reconstruction is achieved by minimizing a total energy containing a data fidelity term and the TNLM energy term. As for the image enhancement, 4D-CBCT images generated by the FDK algorithm are enhanced by minimizing the TNLM function while keeping the enhanced images close to the FDK results. A forward-backward splitting algorithm and a Gauss-Jacobi iteration method are employed to solve the problems. The algorithms implementation on GPU is designed to avoid redundant and uncoalesced memory access, in order to ensure a high computational efficiency. Our algorithms have been tested on a digital NURBS-based cardiac-torso phantom and a clinical patient case. Results: The reconstruction algorithm and the enhancement algorithm generate visually similar 4D-CBCT images, both better than the FDK results. Quantitative evaluations indicate that, compared with the FDK results, our reconstruction method improves contrast-to-noise-ratio (CNR) by a factor of 2.56-3.13 and our enhancement method increases the CNR by 2.75-3.33 times. The enhancement method also removes over 80% of the streak artifacts from the FDK results. The total computation time is 509-683 s for the reconstruction algorithm and 524-540 s for the enhancement algorithm on an NVIDIA Tesla C1060 GPU card. Conclusions: By innovatively taking the temporal redundancy among 4D-CBCT images into consideration, the proposed algorithms can produce high quality 4D-CBCT images with much less streak artifacts than the FDK results, in the situation of inadequate number of projections.

60 APPLIED LIFE SCIENCES↗

Observing crystal nucleation in four dimensions using atomic electron tomography

Nucleation plays a critical role in many physical and biological phenomena that range from crystallization, melting and evaporation to the formation of clouds and the initiation of neurodegenerative diseases. However, nucleation is a challenging process to study in experiments, especially in the early stage when several atoms or molecules start to form a new phase from a parent phase. A number of experimental and computational methods have been used to investigate nucleation processes, but experimental determination of the three-dimensional atomic structure and the dynamics of early stage nuclei has been unachievable. Here we use atomic electron tomography to study early stage nucleation in four dimensions (4D: that is, including time) at atomic resolution. Using FePt nanoparticles as a model system, we find that early stage nuclei are irregularly shaped, each has a core of one to a few atoms with the maximum order parameter, and the order parameter gradient points from the core to the boundary of the nucleus. We capture the structure and dynamics of the same nuclei undergoing growth, fluctuation, dissolution, merging and/or division, which are regulated by the order parameter distribution and its gradient. These experimental observations are corroborated by molecular dynamics simulations of heterogeneous and homogeneous nucleation in liquid–solid phase transitions of Pt. Our experimental and molecular dynamics results differ from classical nucleation theory, indicating that a theory beyond this is needed to describe early stage nucleation at the atomic scale. Looking forward, we anticipate that the reported approach will open the door to the study of many fundamental problems in materials science, nanoscience, condensed matter physics and chemistry, such as phase transition, atomic diffusion, grain boundary dynamics, interface motion, defect dynamics and surface reconstruction with 4D atomic resolution.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Synthetic modeling of soft x-ray emissivity for magnetic island analysis in LTX-β

We present a synthetic soft x-ray (SXR) forward-modeling framework that characterizes the emissivity structure of rotating magnetic islands in the Lithium Tokamak eXperiment-β across space and time. Magnetic islands associated with tearing modes produce modulations in line-integrated SXR brightness. Traditional tomographic methods struggle to resolve these structures in devices with limited sightlines, resulting in an under-determined inversion problem, or otherwise necessitate equilibrium reconstruction data, preventing their use in active control. Our approach removes this challenge by combining a fully three-dimensional ray-tracing model with a time-dependent emissivity prescription of a $m/n$ = 2/1 magnetic island. The model is validated through helical island geometry, rotation measured by magnetic diagnostics, and equilibrium constraints from PSI-Tri reconstructions. Synthetic brightness signals are generated for each photodiode sightline from a modeled emissivity profile and directly compared with experimental data from a tangential midplane SXR array. By fitting the synthetic diagnostic output to the observed brightness across time, we simultaneously infer key geometric parameters-such as island radial location, island width, and rotation frequency-without requiring full tomographic reconstruction, all with an average absolute deviation of less than 3%. This work demonstrates that forward modeling with a single tangential array can extract key island parameters in a spherical tokamak, providing a computationally efficient alternative to conventional SXR tomography and providing a pathway toward real-time magnetic-island characterization in future devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗