Search NASA⌕ Search

SEARCH · Search NASA

Results for “variable flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

A numerical investigation of the finite element method in compressible primitive variable Navier-Stokes flow

The results of a comprehensive numerical investigation of the basic capabilities of the finite element method (FEM) for numerical solution of compressible flow problems governed by the two-dimensional and axis-symmetric Navier-Stokes equations in primitive variables are presented. The strong and weak points of the method as a tool for computational fluid dynamics are considered. The relation of the linear element finite element method to finite difference methods (FDM) is explored. The calculation of free shear layer and separated flows over aircraft boattail afterbodies with plume simulators indicate the strongest assets of the method are its capabilities for reliable and accurate calculation employing variable grids which readily approximate complex geometry and capably adapt to the presence of diverse regions of large solution gradients without the necessity of domain transformation.

Cook, C. H.↗

Acoustic shocks in a variable area duct containing near sonic flows

Acoustic shock waves in a variable area duct which contains near sonic flows are considered. The problem is modeled after an aeroengine inlet. Area variation of a duct and high Mach number mean the flow reduces acoustical energy yielding substantial noise reduction. One possible reason for this is acoustic shock. The use of an explicit accurate numerical method which captures shocks is described. Comparison of the results are made with an existing asymptotic theory for Mach numbers close to unity. When shock occurs reduction of sound pressure levels are shown by example.

Hariharan, S. I.↗

Acoustic shocks in a variable area duct containing near sonic flows

Acoustic shock waves in a variable area duct which contains near sonic flows are considered. The problem is modeled after an aeroengine inlet. Area variation of a duct and high Mach number mean the flow reduces acoustical energy yielding substantial noise reduction. One possible reason for this is acoustic shock. The use of an explicit accurate numerical method which captures shocks is described. Comparison of the results are made with an existing asymptotic theory for Mach numbers close to unity. When shock occurs reduction of sound pressure levels are shown by example.

Hariharan, S. I.↗

Spontaneous formation of knots in relativistic flows - A model for variability in compact synchrotron sources

A model is proposed in which regions of enhanced synchrotron emission are formed via radiative thermal instabilities in relativistic flows. A perturbed volume in which the magnetic field is enhanced by a few tens of a percent relative to the steady value collapses due to the increased cooling rate and consequent loss in pressure. The collapse further increases the magnetic field, leading to even shorter radiative lifetimes. The instability progresses in this way until either the external electron pressure is balanced by the perturbed magnetic pressure or the overall expansion of the flow becomes important. A fluid-dynamical treatment of the instability is performed, and the results are shown to apply to flux variations and formation of knots in the relativistic flows which are thought to occur in quasars and active galactic nuclei. The knots possess the same kinematic properties as the collimated flow and can thus be responsible for the apparent superluminal motions observed in compact radio sources.

Marscher, A. P.↗

Scale-dependent spatial variabilities of hydrological exchange flows and transit time in a large regulated river

Hydrological exchange flows (HEF) across the river-aquifer interface and the associated residence time of river water in the aquifer have important implications for contaminant plume migration and biogeochemical processes in the river corridor. HEFs and residence time are influenced by both subsurface physical features and hydrologic forcing related to the transport process, which can exhibit complex spatial and temporal variations. In this study, we used a massively parallel subsurface flow model and a particle-tracking model to study the influences of different control factors on spatial variability of HEFs and residence time distributions (RTD) in the Hanford Reach of the Columbia River in Washington State. A total number of 100M particles were randomly injected in time and space and then tracked in a model domain that covers a 51-km 2 area (15.1M model cells). We used hourly river stages and groundwater levels to drive the model to provide dynamic velocity fields for the particle tracking in the simulation period that was longer than 2 years. The groundwater flow simulation and particle-tracking results provide the first comprehensive assessment of the spatial distribution of HEFs and residence time in large complex river corridors. Overall, our results show that the aquifer hydrogeological structure has the strongest correlation with the extent and magnitude of exchange flux. The residence time exhibits complex patterns that are impacted by all the river geomorphologic, hydrodynamic, and hydrogeologic factors and are strongly correlated with the downwelling ratio of exchange flux. The new insights gained through this study can be used to support the development of reduced-order models of HEFs and RTDs for large complex river systems.

54 ENVIRONMENTAL SCIENCES↗

Lagrangian simulations of unstable gravity-driven flow of fluids with variable density in randomly heterogeneous porous media

A new Lagrangian particle model based on smoothed particle hydrodynamics (SPH) was developed and used to simulate Darcy scale flow and transport in porous media. The proposed numerical method has excellent conservation properties and treats advection exactly. The method was used in stochastic analysis of miscible density driven fluid flows. It was found that heterogeneity significantly increases dispersion and slows development of Rayleigh-Taylor instability. The presented numerical examples illustrate the advantages of Lagrangian methods for stochastic transport simulations.

Environmental Molecular Sciences Laboratory↗

SU-F-R-51: Radiomics in CT Perfusion Maps of Head and Neck Cancer

Purpose: The aim of this study was to test the predictive value of radiomics features of CT perfusion (CTP) for tumor control, based on a preselection of radiomics features in a robustness study. Methods: 11 patients with head and neck cancer (HNC) and 11 patients with lung cancer were included in the robustness study to preselect stable radiomics parameters. Data from 36 HNC patients treated with definitive radiochemotherapy (median follow-up 30 months) was used to build a predictive model based on these parameters. All patients underwent pre-treatment CTP. 315 texture parameters were computed for three perfusion maps: blood volume, blood flow and mean transit time. The variability of texture parameters was tested with respect to non-standardizable perfusion computation factors (noise level and artery contouring) using intraclass correlation coefficients (ICC). The parameter with the highest ICC in the correlated group of parameters (inter-parameter Spearman correlations) was tested for its predictive value. The final model to predict tumor control was built using multivariate Cox regression analysis with backward selection of the variables. For comparison, a predictive model based on tumor volume was created. Results: Ten parameters were found to be stable in both HNC and lung cancer regarding potentially non-standardizable factors after the correction for inter-parameter correlations. In the multivariate backward selection of the variables, blood flow entropy showed a highly significant impact on tumor control (p=0.03) with concordance index (CI) of 0.76. Blood flow entropy was significantly lower in the patient group with controlled tumors at 18 months (p<0.1). The new model showed a higher concordance index compared to the tumor volume model (CI=0.68). Conclusion: The preselection of variables in the robustness study allowed building a predictive radiomics-based model of tumor control in HNC despite a small patient cohort. This model was found to be superior to the volume-based model. The project was supported by the KFSP Tumor Oxygenation of the University of Zurich, by a grant of the Center for Clinical Research, University and University Hospital Zurich and by a research grant from Merck (Schweiz) AG.

60 APPLIED LIFE SCIENCES↗

Permeation Resistance of Chlorinated Polyethylene Against Hydrazine Fuels

The permeation resistance of chlorinated polyethylene (CPE) used in chemical protective clothing against the aerospace fuels hydrazine, monomethylhydrazine (MMH), and uns-dimethylhydrazine (UDMH) was determined by measuring breakthrough times and time-averaged vapor transmission rates using an ASTM F 739 permeation cell. Two exposure scenarios were simulated: a 2 hour (h) fuel vapor exposure, and a liquid fuel "splash" followed by a 2 h vapor exposure. To simulate internal suit pressure during operation, a positive differential pressure of 0.3 in. water (75 Pa) on the collection side of the permeation apparatus was used. Breakthrough was observed after exposure to liquid MMH, and to vapor and liquid UDMH. No breakthrough was observed after exposure to vapor and liquid hydrazine, or vapor MMH. A model was then used to calculate propellant concentrations inside a totally encapsulating chemical protective suit based on the ASTM permeation data obtained in the present study. Concentrations were calculated under conditions of fixed vapor transmission rate, variable breathing air flow rate, and variable splash exposure area. Calculations showed that the maximum allowable permeation rates of hydrazine fuels through CPE were of the order of 0.05 to 0.08 ng sq cm/min for encapsulating suits with low breathing air flow rates (of the order of 5 scfm or 140 L/min). Above these permeation rates, the 10 parts per billion (ppb) threshold limit value time - weighted average could be exceeded for chemical protective suits having a CPE torso. To evaluate suit performance at ppb level concentrations, use of a sensitive analytical method such as cation exchange high performance liquid chromatography with amperometric detection was found to be essential.

Waller, J. M.↗

Sensitive Procedures for Determining the Permeation Resistance of Chlorinated Polyethylene Against Liquid Propellants

The permeation resistance of chlorinated polyethylene (CPE) used in totally encapsulating chemical protective suits against the aerospace fuels hydrazine, monomethylhydrazine, and uns-dimethylhydrazine was determined by measuring the breakthrough time (BT) and time-averaged vapor transmission rate (VTR) using procedures consistent with ASTM F 739 and ASTM F 1383. Two exposure scenarios were simulated: a 2 hour (h) fuel vapor exposure, and a liquid fuel "splash" followed by a 2 h vapor exposure. To simulate internal suit pressure during operation, a positive differential pressure of 0.3 in. water (75 Pa) on the collection side of the permeation apparatus was used. Using the available data, a model was developed to estimate propellant concentrations inside an air-line fed, totally encapsulating chemical protective suit. Concentrations were calculated under simulated conditions of fixed vapor transmission rate, variable breathing air flow rate, and variable splash exposure area. Calculations showed that the maximum allowable permeation rates of hydrazine fuels through CPE were of the order of 0.05 to 0.08 ng/sq cm min for encapsulating suits with low breathing air flow rates (of the order of 5 scfm or 140 L min-1). Above these permeation rates, the 10 parts-per-billion (ppb) threshold limit value time-weighted average could be exceeded. To evaluate suit performance at 10 ppb threshold-limiting value/time-weighted average level concentrations, use of a sensitive analytical method such as cation exchange high performance liquid chromatography with amperometric detection was found to be essential. The analytical detection limit determines the lowest measurable VTR, which in turn governed the lowest per meant concentration that could be calculated inside the totally encapsulating chemical protective suit.

Waller, Jess M.↗

Computer Modeling VRF Heat Pumps in Commercial Buildings using EnergyPlus

Variable Refrigerant Flow (VRF) heat pumps are increasingly used in commercial buildings in the United States. Monitored energy use of field installations have shown, in some cases, savings exceeding 30% compared to conventional heating, ventilating, and air-conditioning (HVAC) systems. A simulation study was conducted to identify the installation or operational characteristics that lead to energy savings for VRF systems. The study used the Department of Energy EnergyPlus? building simulation software and four reference building models. Computer simulations were performed in eight U.S. climate zones. The baseline reference HVAC system incorporated packaged single-zone direct-expansion cooling with gas heating (PSZ-AC) or variable-air-volume systems (VAV with reheat). An alternate baseline HVAC system using a heat pump (PSZ-HP) was included for some buildings to directly compare gas and electric heating results. These baseline systems were compared to a VRF heat pump model to identify differences in energy use. VRF systems combine multiple indoor units with one or more outdoor unit(s). These systems move refrigerant between the outdoor and indoor units which eliminates the need for duct work in most cases. Since many applications install duct work in unconditioned spaces, this leads to installation differences between VRF systems and conventional HVAC systems. To characterize installation differences, a duct heat gain model was included to identify the energy impacts of installing ducts in unconditioned spaces. The configuration of variable refrigerant flow heat pumps will ultimately eliminate or significantly reduce energy use due to duct heat transfer. Fan energy is also studied to identify savings associated with non-ducted VRF terminal units. VRF systems incorporate a variable-speed compressor which may lead to operational differences compared to single-speed compression systems. To characterize operational differences, the computer model performance curves used to simulate cooling operation are also evaluated. The information in this paper is intended to provide a relative difference in system energy use and compare various installation practices that can impact performance. Comparative results of VRF versus conventional HVAC systems include energy use differences due to duct location, differences in fan energy when ducts are eliminated, and differences associated with electric versus fossil fuel type heating systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydrazine engine plume contamination mapping

Instrumentation for the measurement of plume exhaust specie deposition rates were developed and demonstrated. The instruments, two sets of quartz crystal microbalances, were designed for low temperature operation in the back flow and variable temperature operation in the core flow regions of an exhaust plume. These quartz crystal microbalances performed nominally, and measurements of exhaust specie deposition rates for 8400 number of pulses for a 0.1-lb monopropellant thruster are reported.

Chirivella, J. E.↗

An improved consistent, conservative, non-oscillatory and high order finite difference scheme for variable density low Mach number turbulent flow simulation

A consistent, conservative and truly high order finite difference scheme for low Mach number turbulent variable density flow simulation is presented. In the present scheme, the scalar transport equation is discretized with the explicit weighted compact nonlinear scheme (WCNS) while the continuity and momentum equations are discretized with a conservative centered high order finite difference scheme on a staggered grid. Bounded hybrid high order upwind interpolation is proposed for the evaluation of density on the cell faces of the staggered grid. The use of explicit WCNS along with the bounded density interpolation resolves the issue of degraded order of accuracy in the existing high order finite difference schemes where the centered finite difference scheme for mass and momentum conservation is combined with a total variation stable scheme for scalar transport. With the same difference operator used for the continuity and scalar transport equations, the present scheme is consistent naturally, and resolves the inconsistency problem reported in Trisjono et al. (J. Comp. Phys., 327, 612-628, 2016) without employing any modification to a scheme. Such improvements are demonstrated for several test cases.

02 PETROLEUM↗

Biogeochemical Processes Responsible for the Enhanced Transport of Plutonium Under transient Unsaturated Ground Water Conditions

To better understand longer-term vadose zone transport in southeastern soils, field lysimeter experiments were conducted at the Savannah River Site (SRS) near Aiken, SC, in the 1980s. Each of the three lysimeters analyzed herein contained a filter paper spiked with different Pu solutions, and they were left exposed to natural environmental conditions (including the growth of annual weed grasses) for 11 years. The resulting Pu activity measurements from each lysimeter core showed anomalous activity distributions below the source, with significant migration of Pu above the source. Such results are not explainable by adsorption phenomena alone. A transient variably saturated flow model with root water uptake was developed and coupled to a soil reactive transport model. Somewhat surprisingly, the fully transient analysis showed results nearly identical to those of a much simpler steady flow analysis performed previously. However, all phenomena studied were unable to produce the upward Pu transport observed in the data. This result suggests another transport mechanism such as Pu uptake by roots and upward transport due to transpiration. Thus, the variably saturated flow and reactive transport model was extended to include uptake and transport of Pu within the root xylem, along with computational methodology and results. In the extended model, flow velocity in the soil was driven by precipitation input along with transpiration and drainage. Water uptake by the roots determined the flow velocity in the root xylem, and this along with uptake of Pu in the transpiration stream drove advection and dispersion of the two Pu species in the xylem. During wet periods with high potential evapotranspiration, maximum flow velocities through the xylem would approached 600 cm/hr, orders of magnitude larger that flow velocities in the soil. Values for parameters and the correct conceptual viewpoint for Pu transport in plant xylem was uncertain. This motivated further experiments devoted to Pu uptake by corn roots and xylem transport. Plants were started in wet paper wrapped around each corn seed. When the tap roots were sufficiently long, the seedlings were transplanted to a soil container with the tap root extending out the container bottom. The soil container was then placed over a nutrient solution container, and the solution served as an additional medium for root growth. To conduct an uptake study, a radioactive substance, such as Pu complexed with the bacterial siderophore DFOB, was added to the nutrient solution. After a suitable elapsed time, the corn plant was sacrificed, cut into 10 cm lengths, and the activity distribution measured. Experimental results clarified the basic nature of Pu uptake and transport in corn plants, and resulting simulations suggested that each growing season Pu in the SRS lysimeters would move into the plant shoots and be deposited on the soil surface during the Fall dieback. Subsequent isotope ratio analyses showed that this did happen. OVERALL RESULTS AND CONCLUSIONS - (1) Pu transport downward from the source is controlled by advection, dispersion and adsorption, along with surface-mediated REDOX reactions. (2) Hysteresis, extreme root distribution functions, air-content dependent oxidation rate constants, and large evaporation rates from the soil surface were not able to explain the observed upward migration of Pu. (3) Small amounts of Pu uptake by plant roots and translocation in the transpiration stream creates a realistic mechanism for upward Pu migration (4) Realistic xylem cross-sectional areas imply high flow velocities under hot, wet conditions. Such flow velocities produce the correct shape for the observed activity distributions in the top 20 cm of the lysimeter soil. (5) Simulations imply that Pu should have moved into the above-ground grass tissue each year during the duration of the experiments, resulting in an activity residual accumulating on the soil surface. An isotope ratio analysis showed that the observed surface Pu residue was from the buried sources, not atmospheric fallout. (6) The plant experiments indicate a Pu-DFOB velocity in the corn xylem of at least 174 cm/hr, much higher than ionic Pu in soil. Thus, Pu complexation with chelating agents is probably what led to the observed enhanced uptake and mobility in grasses. (7) Plant experiments show that the uptake of Fe-DFOB, Pu-DFOB and the resulting distributions are very similar. This supports the hypothesis that plant and bacterial iron-seeking chemistry mistakes Pu for Fe.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Characterizing Sub-Daily Flow Regimes: Implications of Hydrologic Resolution on Ecohydrology Studies

Natural variability in flow is a primary factor controlling geomorphic and ecological processes in riverine ecosystems. Within the hydropower industry, there is growing pressure from environmental groups and natural resource managers to change reservoir releases from daily peaking to run-of-river operations on the basis of the assumption that downstream biological communities will improve under a more natural flow regime. In this paper, we discuss the importance of assessing sub-daily flows for understanding the physical and ecological dynamics within river systems. We present a variety of metrics for characterizing sub-daily flow variation and use these metrics to evaluate general trends among streams affected by peaking hydroelectric projects, run-of-river projects and streams that are largely unaffected by flow altering activities. Univariate and multivariate techniques were used to assess similarity among different stream types on the basis of these sub-daily metrics. For comparison, similar analyses were performed using analogous metrics calculated with mean daily flow values. Our results confirm that sub-daily flow metrics reveal variation among and within streams that are not captured by daily flow statistics. Using sub-daily flow statistics, we were able to quantify the degree of difference between unaltered and peaking streams and the amount of similarity between unaltered and run-of-river streams. The sub-daily statistics were largely uncorrelated with daily statistics of similar scope. Furthermore, on short temporal scales, sub-daily statistics reveal the relatively constant nature of unaltered streamreaches and the highly variable nature of hydropower-affected streams, whereas daily statistics show just the opposite over longer temporal scales.

54 ENVIRONMENTAL SCIENCES↗