Search NASA⌕ Search

SEARCH · Search NASA

Results for “visual indicators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Fluorescent Applications to Crystallization

By covalently modifying a subpopulation, less than or equal to 1%, of a macromolecule with a fluorescent probe, the labeled material will add to a growing crystal as a microheterogeneous growth unit. Labeling procedures can be readily incorporated into the final stages of purification, and tests with model proteins have shown that labeling u to 5 percent of the protein molecules does not affect the X-ray data quality obtained . The presence of the trace fluorescent label gives a number of advantages. Since the label is covalently attached to the protein molecules, it "tracks" the protein s response to the crystallization conditions. The covalently attached probe will concentrate in the crystal relative to the solution, and under fluorescent illumination crystals show up as bright objects against a darker background. Non-protein structures, such as salt crystals, do not show up under fluorescent illumination. Crystals have the highest protein concentration and are readily observed against less bright precipitated phases, which under white light illumination may obscure the crystals. Automated image analysis to find crystals should be greatly facilitated, without having to first define crystallization drop boundaries as the protein or protein structures is all that shows up. Fluorescence intensity is a faster search parameter, whether visually or by automated methods, than looking for crystalline features. Preliminary tests, using model proteins, indicates that we can use high fluorescence intensity regions, in the absence of clear crystalline features or "hits", as a means for determining potential lead conditions. A working hypothesis is that more rapid amorphous precipitation kinetics may overwhelm and trap more slowly formed ordered assemblies, which subsequently show up as regions of brighter fluorescence intensity. Experiments are now being carried out to test this approach using a wider range, of proteins. The trace fluorescently labeled crystals will also emit with sufficient intensity to aid in the automation of crystal alignment using relatively low cost optics, further increasing throughput at synchrotrons.

Pusey, Marc L.↗

Behavioral indicators of pilot workload

Using a technique that requires a subject to consult an imagined or remembered spatial array while performing a visual task, a reliable reduction in the number of directed eye movements that are available for the acquisition of visual information is shown.

Galanter, E.↗

Behavioral indicators of pilot workload

Using a technique that requires a subject to consult an imagined or remembered spatial array while performing a visual task, a reliable reduction in the number of directed eye movements that are available for the acquisition of visual information is shown.

Galanter, E.↗

Liquid crystals for high-altitude in-flight boundary layer flow visualization

A novel method for visualization of laminar to turbulent boundary layer transition in flight is presented, in which liquid crystal coatings are used to indicate the transition by a change of color (in response to the changes in the wall shear and the temperature). The liquid crystals applied to the wing surfaces were either cholesteric crystals formulated to be active between temperatures of 30 and 100 F or a sample of chiral nematic liquid crystals formulated to be active between -18 and -22 F. Liquid crystal coatings were shown to provide visualization data at flight altitudes and temperatures at which data could not be obtained previously. Flight evaluations were successfully conducted on a T-34C and a Learjet research aircraft at Mach numbers of up to 0.8 and altitudes of up to 50,000 ft. The time response during oscillating sideslip tests was very rapid. In wind tunnel tests, a hysteresislike behavior was observed in the liquid crystal coatings, possibly because of the lower dynamic pressures in wind tunnels as compared to flight.

Gall, P. D.↗

Low thrust chemical rocket technology

An on-going technology program to improve the performance of low thrust chemical rockets for spacecraft on-board propulsion applications is reviewed. Improved performance and lifetime is sought by the development of new predictive tools to understand the combustion and flow physics, introduction of high temperature materials and improved component designs to optimize performance, and use of higher performance propellants. Improved predictive technology is sought through the comparison of both local and global predictions with experimental data. Predictions are based on both the RPLUS Navier-Stokes code with finite rate kinetics and the JANNAF methodology. Data were obtained with laser-based diagnostics along with global performance measurements. Results indicate that the modeling of the injector and the combustion process needs improvement in these codes and flow visualization with a technique such as 2-D laser induced fluorescence (LIF) would aid in resolving issues of flow symmetry and shear layer combustion processes. High temperature material fabrication processes are under development and small rockets are being designed, fabricated, and tested using these new materials. Rhenium coated with iridium for oxidation protection was produced by the Chemical Vapor Deposition (CVD) process and enabled an 800 K increase in rocket operating temperature. Performance gains with this material in rockets using Earth storable propellants (nitrogen tetroxide and monomethylhydrazine or hydrazine) were obtained through component redesign to eliminate fuel film cooling and its associated combustion inefficiency while managing head end thermal soakback. Material interdiffusion and oxidation characteristics indicated that the requisite lifetimes of tens of hours were available for thruster applications. Rockets were designed, fabricated, and tested with thrusts of 22, 62, 440 and 550 N. Performance improvements of 10 to 20 seconds specific impulse were demonstrated. Higher performance propellants were evaluated: Space storable propellants, including liquid oxygen (LOX) as the oxidizer with nitrogen hydrides or hydrocarbon as fuels. Specifically, a LOX/hydrazine engine was designed, fabricated, and shown to have a 95 pct theoretical c-star which translates into a projected vacuum specific impulse of 345 seconds at an area ratio of 204:1. Further performance improvment can be obtained by the use of LOX/hydrogen propellants, especially for manned spacecraft applications, and specific designs must be developed and advanced through flight qualification.

Schneider, Steven J.↗

Effect of Target Location on Dynamic Visual Acuity During Passive Horizontal Rotation

The vestibulo-ocular reflex (VOR) generates eye rotation to compensate for potential retinal slip in the specific plane of head movement. Dynamic visual acuity (DVA) has been utilized as a functional measure of the VOR. The purpose of this study was to examine changes in accuracy and reaction time when performing a DVA task with targets offset from the plane of rotation, e.g. offset vertically during horizontal rotation. Visual acuity was measured in 12 healthy subjects as they moved a hand-held joystick to indicate the orientation of a computer-generated Landolt C "as quickly and accurately as possible." Acuity thresholds were established with optotypes presented centrally on a wall-mounted LCD screen at 1.3 m distance, first without motion (static condition) and then while oscillating at 0.8 Hz (DVA, peak velocity 60 deg/s). The effect of target location was then measured during horizontal rotation with the optotypes randomly presented in one of nine different locations on the screen (offset up to 10 deg). The optotype size (logMar 0, 0.2 or 0.4, corresponding to Snellen range 20/20 to 20/50) and presentation duration (150, 300 and 450 ms) were counter-balanced across five trials, each utilizing horizontal rotation at 0.8 Hz. Dynamic acuity was reduced relative to static acuity in 7 of 12 subjects by one step size. During the random target trials, both accuracy and reaction time improved proportional to optotype size. Accuracy and reaction time also improved between 150 ms and 300 ms presentation durations. The main finding was that both accuracy and reaction time varied as a function of target location, with greater performance decrements when acquiring vertical targets. We conclude that dynamic visual acuity varies with target location, with acuity optimized for targets in the plane of motion. Both reaction time and accuracy are functionally relevant DVA parameters of VOR function.

Appelbaum, Meghan↗

Development of an Antimicrobial Susceptibility Testing Method Suitable for Performing During Space Flight

Very little is known regarding the affects of the microgravity environment of space flight upon the action of antimicrobial agents on bacterial pathogens. This study was undertaken to develop a simple method for conducting antibacterial susceptibility tests during a Space Shuttle mission. Specially prepared susceptibility test research cards (bioMerieux Vitek, Hazelwood, MO) were designed to include 6-11 serial two-fold dilutions of 14 antimicrobial agents, including penicillins, cephalosporins, a Beta-lactamase inhibitor, vancomycin, erythromycin, tetracycline, gentamicin, ciprofloxacin, and trimethoprim/sulfamethoxazole. Minimal inhibitory concentrations (MICS) of the drugs were determined by visual reading of color endpoints in the Vitek research cards made possible by incorporation of a colorimetric growth indicator (alamarBlue(Trademark), Accumed International, Westlake, OH). This study has demonstrated reproducible susceptibility results when testing isolates of Staphylococcus aurezis, Group A Streptococcus, Enterococcusfaecalis, Escherichia coli (beta-lactamase positive and negative strains), Klebsiella pneumoniae, Enterobacter cloacae, and Pseudomoiias aeruginosa. In some instances, the MICs were comparable to those determined using a standard broth microdilution method, while in some cases the unique test media and format yielded slightly different values, that were themselves reproducible. The proposed in-flight experiment will include inoculation of the Vitek cards on the ground prior to launch of the Space Shuttle, storage of inoculated cards at refrigeration temperature aboard the Space Shuttle until experiment initiation, then incubation of the cards for 18-48 h prior to visual interpretation of MICs by the mission's astronauts. Ground-based studies have shown reproducible MICs following storage of inoculated cards for 7 days at 4-8 C to accommodate the mission's time schedule and the astronauts' activities. For comparison, ground-based control (normal gravity) MIC values will be generated by simultaneous inoculation and incubation of a second set of test cards in a laboratory at the launch site. This procedure can provide a safe and compact experiment that should yield new information on the affects of microgravity on the biological activities of various classes of antibiotics.

Jorgensen, James H.↗

Head-up transition behavior of pilots during simulated low-visibility approaches

Each of 13 commercial pilots from four airlines flew a total of 108 manual flight director approaches in a moving base simulation of a medium-sized turbojet (95,000 lb gross weight) which had a day and night Redifon external scene. Three levels of runway visual range (RVR) (1,600; 2,400; and greater than 8,000 ft), three wind-shear profiles, nine ceiling heights, and continuous and intermittent visibility after initial breakout were tested. The results indicated that: (1) mean decision time ranged from 2 to 4.6 sec for ceilings under 380 ft across the three RVR conditions; (2) mean vertical distance traveled during the visual-cue assessment period was a relatively constant proportion below the existing ceiling; (3) a significant three way interaction in mean decision time between wind shear, day-night, and ceiling RVR variables occurred; (4) mean number of head-up transitions to VFR conditions after breakout ranged from 4.6 to 13.4 and increased as a function of ceiling and severity of wind shear; the typical duration of fixation out the window was 1.5 sec; and (5) subjective pilot ratings of controllability and precision of control as well as amount of skill, attention, or effort required to make the landing were influenced significantly by the wind shear, night conditions, and low breakout ceiling conditions.

Haines, R. F.↗

Five-color photoelectric photometry of asteroid 433 Eros

Five-color (UVBGR) photoelectric light curves of Eros are presented which were obtained on nine nights during the asteroid's 1974/75 close apparition. Indications that three reversals occurred in the relative depths of the two minima between late December 1974 and late January 1975 are noted along with definite evidence of phase reddening. The maximum amplitude observed was 1.44 magnitudes, and the absolute visual magnitude at primary maximum (corrected to zero phase and to 1 AU from the earth and the sun) was about 10.8 magnitudes. Since the observations indicate that Eros has no significant rotational color variations, it is suggested that the light-curve amplitudes are due primarily to the asteroid's shape and to shadowing effects. Based on its colors relative to the sun, it is concluded that Eros appears to be an S-type asteroid.

Miner, E.↗

Multimodal Pilot Behavior in Multi-Axis Tracking Tasks with Time-Varying Motion Cueing Gains

In a large number of motion-base simulators, adaptive motion filters are utilized to maximize the use of the available motion envelope of the motion system. However, not much is known about how the time-varying characteristics of such adaptive filters affect pilots when performing manual aircraft control. This paper presents the results of a study investigating the effects of time-varying motion filter gains on pilot control behavior and performance. An experiment was performed in a motion-base simulator where participants performed a simultaneous roll and pitch tracking task, while the roll and/or pitch motion filter gains changed over time. Results indicate that performance increases over time with increasing motion gains. This increase is a result of a time-varying adaptation of pilots' equalization dynamics, characterized by increased visual and motion response gains and decreased visual lead time constants. Opposite trends are found for decreasing motion filter gains. Even though the trends in both controlled axes are found to be largely the same, effects are less significant in roll. In addition, results indicate minor cross-coupling effects between pitch and roll, where a cueing variation in one axis affects the behavior adopted in the other axis.

motion simulators↗

Energy efficient engine, high-pressure turbine cooling model technology report

Two dimensional flow visualization model tests were used to substantiate the flow stability benefits derived from the use of turning vanes in the root and tip turn flow areas. Results indicate the need for corner fillets and flow injection into the acute corner formed by the intersection of the rib and simulated airfoil suction surface in order to minimize recirculation (stagnation) of flow in that region. Three dimensional flow visualization model tests verified the actual blade coolant passage design.

Gardner, W. B.↗

Convective heating measurement by means of an infrared camera

The development of rapid and accurate wind tunnel techniques to measure convective heating distributions in complex reentry configurations is discussed. Major emphasis was put on the infrared camera technique. Its essence is the measurement of infrared emission from the surface of a wind tunnel model as a function of time. Prior calibration of the infrared camera relates the emission to the surface temperature of the model. The time history of the surface temperature can then be related to the heating rate by standard techniques. The output of the camera is an electrical signal that is tape-recorded in analog form, then digitized and processed by computer, so that automated and relatively rapid data reduction can be accomplished. In addition, the camera produces real-time visual displays of the infrared emission as pictures on an oscilloscope screen. These pictures give immediate indications of hot and cool spots on the model.

Compton, D. L.↗

Electron-beam flow visualization - Applications in the definition of configuration aerothermal characteristics.

Comparisons between flow visualization systems using electron-beam fluorescence, schlieren, and shadowgraph techniques illustrate the advantages associated with the electron beam. Specific applications of this method as an aid in defining the origin of erosion on a heat-transfer model are cited. Results of combined electron-beam oil-flow studies on configurations illustrate that the simultaneous definition of the external flow field and its surface flow can be obtained. Comparisons between the electron-beam oil-flow visualization method and phase-change coating heat-transfer tests on a shuttle ascent configuration indicate the complementary nature of these two testing techniques. Potential methods for improving the electron-beam technique are included.

Woods, W. C.↗

Inventory of forest and rangeland and detection of forest stress

The author has identified the following significant results. Controlled visual interpretation of one ERTS-1 scene taken at the peak of the growing season has indicated that classification to the ECOCLASS Series level is not entirely satisfactory. For five forest classes, aspen, Douglas-fir, lodgepole pine, ponderosa pine, and Spruce/fir, correct identification ranged from 60 to 70 percent. With the exception of shortgrass and wet shrubby meadow classes in the nonforest categories (81 and 100 percent correct, respectively), correct identification of the nonforest classes is so far unacceptable. The low accuracies are believed due to: (1) edge effects due to ecotones between plant community classes with apparent similar image characteristics; (2) confounding effects of amount of plant crown cover and ground surface material in the scene; and (3) variable land slope degree and aspect as it affects the image signature.

Heller, R. C.↗

Spatial frequency doubling - Retinal or central

When a wide field is sinusoidally modulated both in space and in time, the spatial frequency of the pattern will appear doubled at high rates of modulation. Kelly (1966) proposed that this illusion is due to temporal integration of the nonlinear brightness response of the visual system. The anatomical locus of this temporal integrator is uncertain, and could be subcortical. Results indicate that spatial frequency doubling follows binocular disparity detection and is thus a cortical phenomenon.

Richards, W.↗

A scheme for the uniform mapping and monitoring of earth resources and environmental complexes: An assessment of natural vegetation, environmental, and crop analogs

The author has identified the following significant results. A study was performed to develop and test a procedure for the uniform mapping and monitoring of natural ecosystems in the semi-arid and wood regions of the Sierra-Lahontan and Colorado Plateau areas, and for the estimating of rice crop production in the Northern Great Valley (Ca.) and the Louisiana Coastal Plain. ERTS-1 and high flight and low flight aerial photos were used in a visual photointerpretation scheme to identify vegetation complexes, map acreages, and evaluate crop vigor and stress. Results indicated that the vegetation analog concept is valid; that depending on the kind of vegetation and its density, analogs are interpretable at different levels in the hierarchical classification from second to the fourth level. The second level uses physiognomic growth form-structural criteria, and the fourth level uses floristic or taxonomic criteria, usually at generic level. It is recommended that analog comparisons should be made in relatively small test areas where large homogeneous examples can be found of each analog.

Poulton, C. E.↗

Validation of the Passenger Ride Quality Apparatus (PRQA) for simulation of aircraft motions for ride-quality research

The NASA passenger ride quality apparatus (PRQA), a ground based motion simulator, was compared to the total in flight simulator (TIFS). Tests were made on PRQA with varying stimuli: motions only; motions and noise; motions, noise, and visual; and motions and visual. Regression equations for the tests were obtained and subsequent t-testing of the slopes indicated that ground based simulator tests produced comfort change rates similar to actual flight data. It was recommended that PRQA be used in the ride quality program for aircraft and that it be validated for other transportation modes.

Bigler, W. B., II↗

Far-infrared properties of dust in the reflection nebula NGC 7023

Thermal emission from dust in the reflection nebula NGC 7023 has been observed at wavelengths between 40 and 400 microns. The observed far-infrared emission comes from a region approximately 4 arcmin in diameter and shows spatial structure which correlates well with the distribution of reflected visible radiation. Temperature and optical depth maps indicate that the dust which emits the far-infrared radiation is heated by UV and visual radiation from the central star (HD 200775) and that the dust density increases steeply northwest of the star. The far-infrared data are not consistent with either the spherical or uniform slab geometries used in earlier analyses of optical observations. Comparisons of the far-infrared measurements with optical and UV measurements give a value between 2000 and 5000 for the ratio of extinction efficiency in the UV to that at 125 microns. This value is compared with the results of other observational studies and with theoretical grain models.

Whitcomb, S. E.↗