Search NASA⌕ Search

SEARCH · Search NASA

Results for “water availability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24

Effects of forest structural and compositional change on forest microclimates across a gradient of disturbance severity

Forest structural diversity and community composition are key in regulating forest microclimates. When disturbance affects structural diversity or composition, forest microclimates may be altered due to changes in soil temperature, soil water content, and light availability. It is unclear however which structural or compositional components, when changed or to what extent, result in microclimatic change. To address this question, we used data from a large scale, manipulative stem-girdling experiment in northern, lower Michigan—the Forest Resilience and Threshold Experiment (FoRTE). FoRTE follows a factorial design with multiple levels of disturbance severity (0, 45, 65, 85%) based on targeted reductions in gross leaf area index via stem-girdling induced mortality. These disturbance severity treatments are applied in two ways: either as top-down (largest trees are killed) or bottom-up (small to medium trees killed) treatments. We examined how multiple components of structural diversity and community composition changed as a product of disturbance severity and type, and then tested for resulting effects on forest microclimates (light availability, soil temperature, and soil water), using a multivariate, Random Forest framework. We found that measures of community composition (species richness, species evenness, and Shannon-Wiener Diversity Index) and stand structure (basal area, standard deviation of DBH, tree size diversity) declined more following disturbance than did measures of canopy cover, heterogeneity, arrangement, or height. However, when changes in each variable from pre- to post-disturbance, measured as log change, were employed in a multivariate, Random Forest regression framework, structural diversity measures of heterogeneity (rugosity, top rugosity), cover (canopy cover), and arrangement (porosity) were the most influential variables, but with differences among bottom-up and top-down treatments We found that the death of large trees from disturbance impacts soil temperature, water, and light environments more substantially and uniformly across disturbance gradients than does the death of smaller trees. Furthermore, our results have implications for both statistical and process-based modeling of forest disturbance.

54 ENVIRONMENTAL SCIENCES↗

Vegetation water sources in California's Sierra Nevada (USA) are young and change over time, a multi-isotope ( δ 18 O, δ 2 H, 3 H) tracer approach.

Sierra Nevada forests transpire a significant amount of California's water resources, sparking interest in applying forest management to improve California's water supply. Determining the source water of evapotranspiration enables forest managers to make informed decisions. To this end, a significant interest in critical zone science is to develop new methods to work across time scales to predict subsurface water storage and use. Here, forest vegetation accessed young water and switched sources depending on availability, suggesting that forest drought vulnerability may depend on the range of water sources available (rain, snowmelt and deeply stored water). This finding also suggests that changes in transpiration rates may have immediate effects on water sources in close proximity to vegetation, and delayed effects on storage and runoff. New δ 18 O, δ 2 H and 3 H data were used to track precipitation, runoff, evapotranspiration and storage through the critical zone seasonally, including seasons where evapotranspiration and snowmelt were in phase (winter snowmelt) and out of phase (seasonally dry summer). The main source of this headwater catchment's runoff is derived from its meadow saturated zone water, which was dominated by snowmelt. Water that originated as snowmelt contributed to transpiration, unless other sources, such as recent rain, became available. In cases where xylem δ 18 O and δ 2 H signatures matched those of deeper saturated zone water, 3 H data showed that xylem water was distinctly younger than the deep saturated zone water. During 2016, which experienced relatively normal snowpack in winter and seasonally dry summer conditions, mean summer saturated zone water and vegetation water were similar in δ 18 O, –12.4 ± 0.04 ‰ and – 12.5 ± 0.3 ‰, respectively, but were distinctly different in 3 H, 5.5 ± 0.2 pCi/L and 13.7 ± 1.1 pCi/L, respectively. While δ 18 O shows that vegetation and meadow saturated zone water have similar origins, 3 H shows they have dissimilar ages.

58 GEOSCIENCES↗

Mine Water Use, Treatment, and Reuse in the United States: A Look at Current Industry Practices and Select Case Studies

Mining provides significant economic value while often impacting local water supplies and environments because of freshwater usage and waste disposal practices. In this paper we identify current practices in mine water, including how water is used in mining, influent and effluent water quality, treatment technologies, and end uses with the goal of informing future research on implementable, reliable, and cost-effective advanced water treatment in the mining sector. This study also reviews the available literature to broadly evaluate mining in the United States and performs a techno-economic assessment on water use and disposal for three detailed case studies applicable to lithium, uranium, and copper mines. These case studies highlight specific industry examples of distinct extraction methods, geographical regions, and mined commodities. Hypothetical scenarios based on case study baselines revealed potential impacts to mine water available for beneficial reuse through the use of novel water treatment technologies and alternate water management strategies. Finally, an assessment of national level impacts resulting from the reuse of treated mine source water is presented.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An Assessment of Technical Hydropower Potential at Non-Powered Dams in the United States

Historically, dams have been constructed for a variety of purposes, such as providing a more secure and reliable water supply, mitigating impacts from variations in river flow, allowing continuous navigability, and harnessing mechanical power. A relatively small portion of dams have been designed to store or regulate flows for the purpose of generating electricity (roughly 3% of nationally inventoried dams in the US and 17% of the dams included in the World Register of Dams). The remaining population of existing non-powered dams (NPDs) presents both an opportunity to generate renewable energy and a need to modernize aging infrastructure. This report describes an assessment of more than 2,600 NPDs in the US that have a collective potential of nearly 4 GW in new power capacity. Previous national-scale assessments were aimed at evaluating the theoretical maximum power potential at existing dams in the United States. These estimates were based on the best available information at the time for water availability, hydraulic head, and representative regional capacity factors. This study revisits a subset of 3,299 dams identified in the most recent theoretical resource assessment and uses more detailed and updated hydrologic data to produce estimates of technical potential. These improvements in data enable estimates that more realistically reflect what is physically possible given simple assumptions about the existing structure and constraints on flow and head (Figure 1).

13 HYDRO ENERGY↗

Stressors Reveal Ecosystems' Hidden Characteristics

Abstract Vegetation responds dynamically to local microclimates at both short and long time scales via mechanisms ranging from physiological behaviors, such as stomatal closure, to acclimation and adaptation. These responses influence the carbon, water, and energy cycles directly and are therefore crucial to understanding and predicting Earth system responses to a changing climate. Several recent studies have demonstrated that differences in microclimate can induce structural and functional acclimations, and potentially adaptations, within the same ecosystem. Such microclimate divergence can be caused by variability in slopes, disturbance history, or even localized resource availability. Ecosystem stressors such as low soil water availability, limited photoperiod, or high vapor pressure deficit have been shown to reveal the large impact of the subtle differences within these systems such as the number of sun versus shade leaves or differences in whole‐plant water acquisition and use. These findings highlight the linkages between plant canopy structure and ecosystem function, alongside the need for comprehensive analyses of vegetation within the broader context of its environment. This commentary addresses some of the key implications of ecosystem stress responses and accompanying acclimations across three ecosystem types for ecosystem ecology, plant physiology, ecohydrology and trait‐based modeling of vegetation‐climate dynamics.

Matheny, Ashley M.↗

Pathway to Complete Energy Sector Decarbonization with Available Iridium Resources using Ultralow Loaded Water Electrolyzers

We present ultralow Ir-loaded (ULL) proton exchange membrane water electrolyzer (PEMWE) cells that can produce enough hydrogen to largely decarbonize the global natural gas, transportation, and electrical storage sectors by 2050, using only half of the annual global Ir production for PEMWE deployment. This represents a significant improvement in PEMWE's global potential, enabled by careful control of the anode catalyst layer (CL), including its mesostructure and catalyst dispersion. Using commercially relevant membranes (Nafion 117), cell materials, electrocatalysts, and fabrication techniques, we achieve at peak a 250× improvement in Ir mass activity over commercial PEMWEs. An optimal Ir loading of 0.011 mg Ir cm -2 operated at an Ir-specific power of ~100 MW kg Ir -1 at a cell potential of ~1.66 V versus RHE (85% higher heating value efficiency). Here, we further evaluate the performance limitations within the ULL regime and offer new insights and guidance in CL design relevant to the broader energy conversion field.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Prediction of the Inter-Tube Flow Mode Transitions in the Evaporators of Multi-Effect Thermal Desalination Plants

Water is one of the most stressed resources on the planet. The limited availability of fresh water and the high cost of transportation have led to an increased interest in water desalination technologies. The two main categories of desalination techniques are membrane desalination and thermal desalination. Membrane technologies include pressure driven and electrical driven membranes. On the other hand, thermal desalination includes: multi-effect desalination (MED), multi-stage flash (MSF) desalination, and mechanical vapor compression desalination. Multi-effect desalination plants are usually made of a series of evaporators (also known as effects). In each effect, hot steam flows inside the tubes and evaporates the seawater that falls on the outside of the tubes. The vapor formed at each effect flows to the next effect and acts as the heating medium for the falling seawater. The prevailing flow mode of the falling seawater (i.e. droplet, jet, or sheet) influences heat and mass transfer as well as dry out in the evaporators of Multi-Effect Desalination (MED) plants. The objective of this paper is to predict and discuss the prevailing falling film flow modes in the evaporators of MED plants, under different operating conditions. The paper demonstrates the transitional Reynolds numbers between the main falling film modes for seawater. This closes a gap in the literature where there is a dearth of mode transition data for seawater. The effect of fluid properties and tube geometry on the transitions is discussed in details. As a result, the accuracy of the predicted transitional Reynolds numbers is evaluated via uncertainty quantification techniques.

availability↗

GCAM–GLORY v1.0: representing global reservoir water storage in a multi-sector human–Earth system model

Abstract. Reservoirs play a significant role in modifying the spatiotemporal availability of surface water to meet multi-sector human demands, despite representing a relatively small fraction of the global water budget. Yet the integrated modeling frameworks that explore the interactions among climate, land, energy, water, and socioeconomic systems at a global scale often contain limited representations of water storage dynamics that incorporate feedbacks from other systems. In this study, we implement a representation of water storage in the Global Change Analysis Model (GCAM) to enable the exploration of the future role (e.g., expansion) of reservoir water storage globally in meeting demands for, and evolving in response to interactions with, the climate, land, and energy systems. GCAM represents 235 global water basins, operates at 5-year time steps, and uses supply curves to capture economic competition among renewable water (now including reservoirs), non-renewable groundwater, and desalination. Our approach consists of developing the GLObal Reservoir Yield (GLORY) model, which uses a linear programming (LP)-based optimization algorithm and dynamically linking GLORY with GCAM. The new coupled GCAM–GLORY approach improves the representation of reservoir water storage in GCAM in several ways. First, the GLORY model identifies the cost of supplying increasing levels of water supply from reservoir storage by considering regional physical and economic factors, such as evolving monthly reservoir inflows and demands, and the leveled cost of constructing additional reservoir storage capacity. Second, by passing those costs to GCAM, GLORY enables the exploration of future regional reservoir expansion pathways and their response to climate and socioeconomic drivers. To guide the model toward reasonable reservoir expansion pathways, GLORY applies a diverse array of feasibility constraints related to protected land, population, water sources, and cropland. Finally, the GLORY–GCAM feedback loop allows evolving water demands from GCAM to inform GLORY, resulting in an updated supply curve at each time step, thus enabling GCAM to establish a more meaningful economic value of water. This study improves our understanding of the sensitivity of reservoir water supply to multiple physical and economic dimensions, such as sub-annual variations in climate conditions and human water demands, especially for basins experiencing socioeconomic droughts.

54 ENVIRONMENTAL SCIENCES↗

A simple framework to characterize land aridity based on surface energy partitioning regimes

Land aridity is often characterized by the aridity index (AI), which does not account for land surface water-energy interactions that are crucially important in determining regional climate. Such interactions can be captured by the evaporative fraction (EF, ratio of evapotranspiration to available energy) regimes. As EF is subject to energy and water limitations in humid and dry areas, respectively, EF regimes may be used to characterize land aridity to account for the influence of complex land characteristics and their impact on water availability. Here, we propose a simple framework to characterize land aridity by statistically ranking the coupling strength between EF and surface energy and water terms. The framework is demonstrated using gridded data and compared with AI over the U.S. and China. Results show that regionalization of aridity zones based on EF regimes and a two-tiered classification scheme may provide information such as surface energy and water variability complementary to the background aridity depicted by AI, with implications for extreme events.

54 ENVIRONMENTAL SCIENCES↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Recent Upper Colorado River Streamflow Declines Driven by Loss of Spring Precipitation

Abstract Colorado River streamflow has decreased 19% since 2000. Spring (March‐April‐May) weather strongly influences Upper Colorado River streamflow because it controls not only water input but also when snow melts and how much energy is available for evaporation when soils are wettest. Since 2000, spring precipitation decreased by 14% on average across 26 unregulated headwater basins, but this decrease did not fully account for the reduced streamflow. In drier springs, increases in energy from reduced cloud cover, and lowered surface albedo from earlier snow disappearance, coincided with potential evapotranspiration (PET) increases of up to 10%. Combining spring precipitation decreases with PET increases accounted for 67% of the variance in post‐2000 streamflow deficits. Streamflow deficits were most substantial in lower elevation basins (<2,950 m), where snowmelt occurred earliest, and precipitation declines were largest. Refining seasonal spring precipitation forecasts is imperative for future water availability predictions in this snow‐dominated water resource region.

Geology↗

Salinity Contributions from Geothermal Waters to the Rio Grande and Shallow Aquifer System in the Transboundary Mesilla (United States)/Conejos-Médanos (Mexico) Basin

Freshwater scarcity has raised concerns about the long-term availability of the water supplies within the transboundary Mesilla (United States)/Conejos-Médanos (Mexico) Basin in Texas, New Mexico, and Chihuahua. Analysis of legacy temperature data and groundwater flux estimates indicates that the region’s known geothermal systems may contribute more than 45,000 tons of dissolved solids per year to the shallow aquifer system, with around 8500 tons of dissolved solids being delivered from localized groundwater upflow zones within those geothermal systems. If this salinity flux is steady and eventually flows into the Rio Grande, it could account for 22% of the typical average annual cumulative Rio Grande salinity that leaves the basin each year—this salinity proportion could be much greater in times of low streamflow. Regional water level mapping indicates upwelling brackish waters flow towards the Rio Grande and the southern part of the Mesilla portion of the basin with some water intercepted by wells in Las Cruces and northern Chihuahua. Upwelling waters ascend from depths greater than 1 km with focused flow along fault zones, uplifted bedrock, and/or fractured igneous intrusions. Overall, this work demonstrates the utility of using heat as a groundwater tracer to identify salinity sources and further informs stakeholders on the presence of several brackish upflow zones that could notably degrade the quality of international water supplies in this developed drought-stricken region.

Pepin, Jeff D. (ORCID:0000000274109979)↗

Prokaryotic responses to a warm temperature anomaly in northeast subarctic Pacific waters

Recent studies on marine heat waves describe water temperature anomalies causing changes in food web structure, bloom dynamics, biodiversity loss, and increased plant and animal mortality. However, little information is available on how water temperature anomalies impact prokaryotes (bacteria and archaea) inhabiting ocean waters. This is a nontrivial omission given their integral roles in driving major biogeochemical fluxes that influence ocean productivity and the climate system. Here we present a time-resolved study on the impact of a large-scale warm water surface anomaly in the northeast subarctic Pacific Ocean, colloquially known as the Blob, on prokaryotic community compositions. Multivariate statistical analyses identified significant depth- and season-dependent trends that were accentuated during the Blob. Moreover, network and indicator analyses identified shifts in specific prokaryotic assemblages from typically particle-associated before the Blob to taxa considered free-living and chemoautotrophic during the Blob, with potential implications for primary production and organic carbon conversion and export.

54 ENVIRONMENTAL SCIENCES↗

Spatiotemporal Variations of Evapotranspiration in Amazonia Using the Wavelet Phase Difference Analysis

The relationships and seasonal-to-annual variations among evapotranspiration (ET), precipitation (P), terrestrial water storage anomalies (TWSA), radiation (downward shortwave radiation, DSR), and phenology (leaf area index, LAI) are complex across the Amazon basin. Here, to analyze how ET is controlled by these influencing factors, we used wavelet phase difference (WPD) to investigate the effects of P, TWSA, DSR, and LAI on ET at different spatiotemporal scales. The Amazon-scale averaged ET has strong correlations with these factors at the annual and multi-year periodicities. The patterns of WPDs have south-north and west-east divides due to the significant variation in climatic conditions. The results demonstrate that ET is mainly affected by water and energy availability while vegetation regulates both processes. The deep soil moisture/groundwater can provide strong subsidies to ET during the meteorological dry season in the water-limited area of Amazon. The WPD can well reflect the responses of ET to the variations of P, TWSA, DSR, and LAI, and the process of vegetation sustaining ET in the dry years in the water-limited area of the Amazon.

54 ENVIRONMENTAL SCIENCES↗