Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerator Magnets”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

SU-F-J-50: Study On the Magnetic Field Effect On the Exradin W1 Plastic Scintillation Detector

Purpose: To study the response of the Exradin W1 plastic scintillator detector to a 6 MV photon field in the presence of a strong magnetic field (B). Methods: An Exradin W1 scintillator detector coupled to a SuperMax two-channel electrometer, both manufactured by Standard Imaging, Inc., was first calibrated in a Co-60 beam. The Cerenkov Light Ratio (CLR) was obtained following the procedure recommended by the manufacturer. Subtracting signal in channel 2 multiplied by CLR from the signal in channel 1 should lead to a Cerenkov-free signal. The W1 scintillator was placed in a plastic phantom inside a dipole electromagnet (GMW Associates) that could produce a strong B field, and irradiated using a 6 MV beam from an Elekta Versa HD LINAC. Signals from both channels of the W1 scintillator were acquired as a function of B (0 - 1.5 T). Results: The signals from both channels increased as a function of the B field strength. At 1.5 T, channel 1 increased by 11% compared to the baseline (B=0 T), while channel 2 increased by 22%. Applying the recommended Cerenkov correction led to a 2% difference between dose measurement with and without a magnetic field. The values between B=0.3 T and B=1.5 T remained constant. Conclusion: Signals from the Exradin W1 plastic scintillation detector increased as the B field increased. This increase mainly comes from a change in the amount of Cerenkov light coupled within the optical fiber. Removing the Cerenkov component following the procedure recommended by the manufacturer showed to be an effective way to measure dose accurately in strong magnetic fields. The cause for the residual 2% difference is currently under investigation. We acknowledge research support from Elekta AB.

60 APPLIED LIFE SCIENCES↗

Development of a bunched beam electron cooler for the Jefferson Lab electron-ion collider

Jefferson Lab is in the process of designing an electron-ion collider with unprecedented luminosity at a 65 GeV center-of-mass energy. This luminosity relies on ion cooling in both the booster and the storage ring of the accelerator complex. The cooling in the booster will use a conventional DC cooler similar to the one at COSY. The high-energy storage ring, operating at a momentum of up to 100 GeV/nucleon, requires novel use of bunched-beam cooling. We will present a new design for a Circulator Cooler Ring for bunched-beam electron cooling. This requires the generation and transport of very high-charge magnetized bunches, acceleration of the bunches in an energy recovery linac, and transfer of these bunches to a circulating ring that passes the bunches 11 times through the proton or ion beam inside cooling solenoids. This design requires the suppression of the effects of space charge and coherent synchrotron radiation using shielding and RF compensation.

Benson, Stephen V.↗

Magnetic design of the commutational magnet and quadrupoles for PERLE accelerator

PERLE (Powerful Energy Recovery LINAC for Experiment) is a high-power Energy Recovery LINAC (ERL) facility with 20 mA beam current and beam energy from 250 MeV to 500 MeV featuring three passes through two cryomodules. It is a hub for validation of the ERL technology development towards future energy and intensity frontier machines. Design challenges of PERLE and its beam parameters make it a test-bed to validate multi-turn high current ERL operation for the LHeC. It will be the first ERL for some pioneering experiment of the eN interaction with radioactive nuclei. In this work, design and optimization of the commutational magnet (B-com) used to spread/combine the three beams and one series of the quadrupole magnet is discussed. It gives the design parameters including: yoke geometry, pole profile, and material, and calculation of the excitation current needed to drive the magnet, the coil parameters and the number of turns. The B-com magnet is optimized for a 30° bending angle with magnetic field of 0.88 T along the magnet length and a harmonic content of 0.036%. The quadrupole magnet is designed for a gradient field of 34.15 T/m and experiences saturation above this value. Further studies to avoid saturation and achieve the maximum gradient of 44.1 T/m required by the beam dynamics is undergoing.

Abukeshek, R.↗

Magnetic design of the commutational magnet and quadrupoles for PERLE accelerator

PERLE (Powerful Energy Recovery LINAC for Experiment) is a high-power Energy Recovery LINAC (ERL) facility with 20 mA beam current and beam energy from 250 MeV to 500 MeV featuring three passes through two cryomodules. It is a hub for validation of the ERL technology development towards future energy and intensity frontier machines. Design challenges of PERLE and its beam parameters make it a test-bed to validate multi-turn high current ERL operation for the LHeC. It will be the first ERL for some pioneering experiment of the eN interaction with radioactive nuclei. In this work, design and optimization of the commutational magnet (B-com) used to spread/combine the three beams and one series of the quadrupole magnet is discussed. It gives the design parameters including: yoke geometry, pole profile, and material, and calculation of the excitation current needed to drive the magnet, the coil parameters and the number of turns. The B-com magnet is optimized for a 30° bending angle with magnetic field of 0.88 T along the magnet length and a harmonic content of 0.036%. The quadrupole magnet is designed for a gradient field of 34.15 T/m and experiences saturation above this value. Further studies to avoid saturation and achieve the maximum gradient of 44.1 T/m required by the beam dynamics is undergoing.

Abukeshek, R.↗

Kinetic Simulations of Electron Pre-energization by Magnetized Collisionless Shocks in Expanding Laboratory Plasmas

Collisionless shocks are common features in space and astrophysical systems where supersonic plasma flows interact, such as in the solar wind, the heliopause, and supernova remnants. Recent experimental capabilities and diagnostics allow detailed laboratory investigations of high-Mach-number shocks, which therefore can become a valuable way to understand shock dynamics in various astrophysical environments. Using 2D particle-in-cell simulations with a Coulomb binary collision operator, we demonstrate the mechanism for generation of energetic electrons and experimental requirements for detecting this process in the laboratory high-Mach-number collisionless shocks. We show through a parameter study that electron acceleration by magnetized collisionless shocks is feasible in laboratory experiments with laser-driven expanding plasmas.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-J-146: Experimental Validation of 6 MV Photon PDD in Parallel Magnetic Field Calculated by EGSnrc

Purpose: Integrated linac-MR systems are uniquely suited for real time tumor tracking during radiation treatment. Understanding the magnetic field dose effects and incorporating them in treatment planning is paramount for linac-MR clinical implementation. We experimentally validated the EGSnrc dose calculations in the presence of a magnetic field parallel to the radiation beam travel. Methods: Two cylindrical bore electromagnets produced a 0.21 T magnetic field parallel to the central axis of a 6 MV photon beam. A parallel plate ion chamber was used to measure the PDD in a polystyrene phantom, placed inside the bore in two setups: phantom top surface coinciding with the magnet bore center (183 cm SSD), and with the magnet bore’s top surface (170 cm SSD). We measured the field of the magnet at several points and included the exact dimensions of the coils to generate a 3D magnetic field map in a finite element model. BEAMnrc and DOSXYZnrc simulated the PDD experiments in parallel magnetic field (i.e. 3D magnetic field included) and with no magnetic field. Results: With the phantom surface at the top of the electromagnet, the surface dose increased by 10% (compared to no-magnetic field), due to electrons being focused by the smaller fringe fields of the electromagnet. With the phantom surface at the bore center, the surface dose increased by 30% since extra 13 cm of air column was in relatively higher magnetic field (>0.13T) in the magnet bore. EGSnrc Monte Carlo code correctly calculated the radiation dose with and without the magnetic field, and all points passed the 2%, 2 mm Gamma criterion when the ion chamber’s entrance window and air cavity were included in the simulated phantom. Conclusion: A parallel magnetic field increases the surface and buildup dose during irradiation. The EGSnrc package can model these magnetic field dose effects accurately. Dr. Fallone is a co-founder and CEO of MagnetTx Oncology Solutions (under discussions to license Alberta bi-planar linac MR for commercialization).

60 APPLIED LIFE SCIENCES↗

SU-F-J-144: Scatter and Leakage Survey of An Integrated MR-Linac System

Purpose: To assess the scatter and leakage radiation of an integrated 1.5T MRI-Linac system. Methods: A 150cc chamber (model 96020C, Inovision) was used in all the scatter and leakage measurements, after being recalibrated for MV energy by the Accredited Dosimetry Calibration Laboratory at MD Anderson. The scatter radiation was measured by placing a 25 cm stack of solid-water materials at iso-center on the patient couch to simulate patient scatter. Gantry angles were positioned at 0 degree (beam pointing downward) and 270 (beam pointing laterally). Scatter radiation was measured at selective locations inside the RF room. Beam stopper leakage was measured at the exterior panel of the gantry. The head leakage was measured at 1 meter away from the Linac head in the direction which was determined to be the area of maximum leakage by wrapped films test. All measurements were repeated with the 1.5T magnetic field turned off to study the effect of magnetic field. Results: When the magnet was on (B=1.5T), the maximum head leakage at 1 meter was 191.6mR/1000MU. The scatter radiation at 1 meter from the iso-center was 1.091R/1000MU when the radiation beam was pointing downward, 1.296R/1000MU when the beam pointed laterally. The beam stopper leakage was measured as 299.4 mR/1000MU at the exterior panel of the gantry. When magnet was off (B=0), the head leakage was measured as 198.6mR/1000MU. The scatter radiation at 1 meter was 1.153R/1000MU when beam pointed downward, 1.287R/1000MU when beam pointed laterally. The beam stopper leakage was measured as 309.4 mR/1000MU at the exterior panel of the gantry. Conclusion: The measurements indicate that the scatter and leakage radiation from the integrated MR-Linac system are in-line with the expected values. The beam stopper leakage is approximately 300 mR/1000MU. The leakage and scatter difference with the magnetic field ON and OFF was within 5%. The authors received a corporate sponsored grant from Elekta which is the vendor of the MR-Linac system studied in this work.

60 APPLIED LIFE SCIENCES↗

Prompt particle acceleration around moving X-point magnetic field during impulsive phase of solar flares

We present a model for high-energy solar flares to explain prompt proton and electron acceleration, which occurs around moving X-point magnetic field during the implosion phase of the current sheet. We derive the electromagnetic fields during the strong implosion phase of the current sheets, which is driven by the converging flow derived from the magnetohydrodynamic equations. It is shown that both protons and electrons can be promptly (within 1 second) accelerated to approximately 70 MeV and approximately 200 MeV, respectively. This acceleration mechanism can be applicable for the impulsive phase of the gradual gamma ray and proton flares (gradual GR/P flare), which have been called two-ribbon flares.

Sakai, Jun-Ichi↗

Magnetic quench antenna for MQXF quadrupoles

High-field MQXF-series quadrupoles are presently under development by LARP and CERN for the upcoming LHC luminosity upgrade. Quench training and protection studies on MQXF prototypes require a capability to accurately localize quenches and measure their propagation velocity in the magnet coils. The voltage tap technique commonly used for such purposes is not a convenient option for the 4.2-m-long MQXF-A prototype, nor can it be implemented in the production model. We have developed and tested a modular inductive magnetic antenna for quench localization. The base element of our quench antenna is a round-shaped printed circuit board containing two orthogonal pairs of flat coils integrated with low-noise preamplifiers. The elements are aligned axially and spaced equidistantly in 8-element sections using a supporting rod structure. The sections are installed in the warm bore of the magnet, and can be stacked together to adapt for the magnet length. We discuss the design, operational characteristics and preliminary qualification of the antenna. Lastly, axial quench localization capability with an accuracy of better than 2 cm has been validated during training test campaign of the MQXF-S1 quadrupole.

43 PARTICLE ACCELERATORS↗

Quantitative Examination of a Large Sample of Supra-Arcade Downflows in Eruptive Solar Flares

Sunward-flowing voids above post-coronal mass ejection flare arcades were first discovered using the soft X-ray telescope aboard Yohkoh and have since been observed with TRACE (extreme ultraviolet (EUV)), SOHO/LASCO (white light), SOHO/SUMER (EUV spectra), and Hinode/XRT (soft X-rays). Supra-arcade downflow (SAD) observations suggest that they are the cross-sections of thin flux tubes retracting from a reconnection site high in the corona. Supra-arcade downflowing loops (SADLs) have also been observed under similar circumstances and are theorized to be SADs viewed from a perpendicular angle. Although previous studies have focused on dark flows because they are easier to detect and complementary spectral data analysis reveals their magnetic nature, the signal intensity of the flows actually ranges from dark to bright. This implies that newly reconnected coronal loops can contain a range of hot plasma density. Previous studies have presented detailed SAD observations for a small number of flares. In this paper, we present a substantial SADs and SADLs flare catalog. We have applied semiautomatic detection software to several of these events to detect and track individual downflows thereby providing statistically significant samples of parameters such as velocity, acceleration, area, magnetic flux, shrinkage energy, and reconnection rate. We discuss these measurements (particularly the unexpected result of the speeds being an order of magnitude slower than the assumed Alfven speed), how they were obtained, and potential impact on reconnection models.

Savage, Sabrina L.↗

SU-F-T-451: Doses to Organs-At-Risk in the Presence and Absence of a 1.5 T Magnetic Field for NSCLC Patients Undergoing SABR

Purpose: To determine whether the electron return effect (ERE) has deleterious effects on lung SABR plans optimized in the presence of an orthogonal 1.5 T magnetic field. Methods: Data from five NSCLC-SABR patients were used. The Dose was modeled with a 2.5 mm dose grid in the presence and absence of a magnetic field using the Monaco (Elekta) TPS with the Monte Carlo GPUMCD (v5.1) algorithm. For each patient, two plans were generated, one using our conventional Elekta Agility linac beam model and another using the Elekta MRI Linac (MRL) model. Both plans were generated on the average CT using similar dose constraints and a 5 mm PTV. The optimization was performed using our clinic’s planning criteria, with normalization of the targets such that their V99% was equal to 99%. The OAR DVHs were compared for each patient. Results: The DVH plots revealed that there were limited differences when optimizing plans in the presence or absence of the magnetic field. The mean of the absolute differences, between the two planning types, in the equivalent uniform doses (EUDs) for the OARs were: 0.3 Gy (range of 0.0 - 1.0 Gy) for the esophagus, 0.6 Gy (range of 0.1 – 1.9 Gy) for the heart, 0.5 Gy (range of 0.2 – 0.8 Gy) for the lungs, and 0.6 Gy (range of 0.2 – 1.5 Gy) for the spinal canal. Regarding the maximum doses to the serial organs, the mean of the differences were 3.0 Gy (esophagus) and 0.9 Gy (spinal canal). No trends in the differences were observed. Conclusion: This study has demonstrated that there were no major differences between plans optimized using a conventional linac and those optimized using an MRI linac with an orthogonal 1.5 T magnetic field. This is attributed to the consideration of the ERE in the optimization. This project was made possible with the financial support of Elekta.

60 APPLIED LIFE SCIENCES↗

TH-AB-BRA-10: The Physics of Interface Effects for Radiation Treatments in a MRI-Linac: A Monte Carlo Study

Purpose: To investigate and explain the interface effects for clinically relevant materials being irradiated in the presence of a 1.5 T transverse magnetic field. Methods: Interface effects were investigated using Geant4.10.1 both with (B-On) and without (B-Off) a magnetic field for an Elekta MRI-Linac. A slab of thickness 8 cm, representing inhomogeneity, was placed at a depth of 4 cm in a 20×20×20 cm water phantom. Backscattered electron fluence was calculated through a 20×20 cm plane aligned with the surface of the inhomogeneity. Inhomogeneities investigated were lung, bone, aluminum, titanium, stainless steel, and dental filling. A photon beam with field size of 2×2 cm at the isocenter and SAD of 143.5 cm was generated from a point source with energy distribution sampled from a histogram representing the true Elekta MRI-Linac photon spectrum. Results: In the B-On case, if the heterogeneity is a low Z{sub eff} material, such as lung, the backscattered electron fluence is increased considerably, i.e. by 54 %, and the corresponding dose is expected to be higher near the interface compared to the B-Off case. On the contrary, if the heterogeneity is a high Z{sub eff} material then the backscattered electron fluence is reduced in the B-On electron fluence is reduced in the B-On case. This reduction leads to a lower dose deposition at the interface compared to the B-Off case. Conclusion: The reduction in dose at the interface, in the B-On case, is directly related to the reduction in backscattered electron fluence. The reduction in backscattered electron fluence occurs due to two different reasons. First, the electron energy spectrum hitting the interface is changed for the B-On case which changes the electron scattering probability. Second, some electrons that are looping under the influence of the magnetic field are captured by the higher density side of the interface and no longer contribute to the backscattered electron stream. Funding support for this study was provided by ElektaTM.

60 APPLIED LIFE SCIENCES↗

TH-CD-BRA-04: Effect of a Strong Magnetic Field On TLDs, OSLDs, and Gafchromic Films Using An Electromagnet

Purpose: To study the effect of strong magnetic field on three types of dosimeters using an electromagnet inside a Linac vault. Materials and Methods: Three types of dosimeters, thermoluminescent Dosimeters (TLDs), optically stimulated luminescent Dosimeters (OSLDs), and EBT3 Film were used to measure radiation dose response inside an electromagnet that could produce a strong magnetic field (B>1.5 T). The dosimeters were placed inside a plastic phantom between the two poles of the magnet, at approximately 3 meters from the iso-center of an Elekta Versa HD Linac. The B field was calibrated with a Gauss meter (Model: GM-2, AlphaLab Inc). The dosimeters received ∼2 Gy with and without the presence of the 1.5 T magnetic field. The EBT3 films were scanned 24 hours before and 24 hours after irradiation. The TLD dosimeters were read 1 week after irradiation. The OSLDs were read two weeks after irradiation. The ratios of signals of dosimeters irradiated with the B field to the signals without the B field were calculated. Two experiments have been conducted so far. Results: The ratios (averaged over two experiments) of dosimeter signals with vs without B field were 0.994 for films, 0.994 for OSLDs, and 1.002 for TLDs. The statistical uncertainty was ∼3%. Conclusions: The three types of dosimeters (film, TLD, OSLD) seem not affected by the presence of a magnetic field (B=1.5 T) with the uncertainty of ∼3%. They may be suitable for QA purposes in a strong B field up to 1.5 T. More measurements will be conducted for reproducibility testing. We acknowledge research support from Elekta AB.

60 APPLIED LIFE SCIENCES↗

Design and fabrication of a 30 T superconducting solenoid using overpressure processed Bi2212 round wire

High field superconducting magnets are used in particle colliders, fusion energy devices, and spectrometers for medical imaging and advanced materials research. Magnets capable of generating fields of 20-30 T are needed by future accelerator facilities. A 20-30 T magnet will require the use of high-temperature superconductors (HTS) and therefore the challenges of high field HTS magnet development need to be addressed. Superconducting Bi 2 Sr 2 CaCu 2 O x (Bi2212) conductors fabricated by the oxide-powder-in-tube (OPIT) technique have demonstrated the capability to carry large critical current density of 10 5 A/cm 2 at 4.2 K and in magnetic fields up to 45 T. Available in round wire multi-filamentary form, Bi2212 may allow fabrication of 20-50 T superconducting magnets. Until recently the performance of Bi2212 has been limited by challenges in realizing high current densities (J c ) in long lengths. This problem now is solved by the National High Magnetic Field Lab using an overpressure (OP) processing technique, which uses external pressure to process the conductor. OP processing also helps remove the ceramic leakage that results when Bi-2212 liquid leaks out from the sheath material and reacts with insulation, coil forms, and flanges. Significant advances have also been achieved in developing novel insulation materials (TiO 2 coating) and Ag-Al sheath materials that have higher mechanical strengths than Ag-0.2wt.% Mg, developing heat treatment approaches to broadening the maximum process temperature window, and developing high-strength, mechanical reinforced Bi-2212 cables. In the Phase I work, we leveraged these new opportunities to prototype overpressure processed solenoids and test them in background fields of up to 14 T. Additionally a design of a fully superconducting 30 T solenoid was produced. This work in conjunction with the future path outlined in the Phase II proposal would provide a major step toward qualifying Bi2212 technology for use in high-field accelerator magnets. Additionally, the performance parameters match key requirements of a final muon beam cooling solenoid. This technology will also be of interest to high-field NMR manufacturers.

43 PARTICLE ACCELERATORS↗

Status of the MQXFB Nb 3 Sn Quadrupoles for the HL-LHC

Here, the cold powering test of the first two prototypes of the MQXFB quadrupoles (MQXFBP1, now disassembled, and MQXFBP2), the Nb 3 Sn inner triplet magnets to be installed in the HL-LHC, has validated many features of the design, such as field quality and quench protection, but has found performance limitations. In fact, both magnets showed a similar phenomenology, characterized by reproducible quenches in the straight part inner layer pole turn, with absence of training and limiting the performance at 93% (MQXFBP1) and 98% (MQXFBP2) of the nominal current at 1.9 K, required for HL-LHC operation at 7 TeV. Microstructural inspections of the quenching section of the limiting coil in MQXFBP1 have identified fractured Nb 3 Sn sub-elements in strands located at one specific position of the inner layer pole turn, allowing to determine the precise origin of the performance limitation. In this paper we outline the strategy that has been defined to address the possible sources of performance limitation, namely coil manufacturing, magnet assembly and integration in the cold mass.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The 11 T dipole for HL-LHC: Status and plan

The upgrade of the Large Hadron Collider (LHC) collimation system includes additional collimators in the LHC lattice. The longitudinal space for these collimators will be created by replacing some of the LHC main dipoles with shorter but stronger dipoles compatible with the LHC lattice and main systems. The project plan comprises the construction of two cryoassemblies containing each of the two 11-T dipoles of 5.5-m length for possible installation on either side of interaction point 2 of LHC in the years 2018-2019 for ion operation, and the installation of two cryoassemblies on either side of interaction point 7 of LHC in the years 2023-2024 for proton operation. The development program conducted in conjunction between the Fermilab and CERN magnet groups is progressing well. The development activities carried out on the side of Fermilab were concluded in the middle of 2015 with the fabrication and test of a 1-m-long two-in-one model and those on the CERN side are ramping up with the construction of 2-m-long models and the preparation of the tooling for the fabrication of the first full-length prototype. The engineering design of the cryomagnet is well advanced, including the definition of the various interfaces, e.g., with the collimator, powering, protection, and vacuum systems. Several practice coils of 5.5-m length have been already fabricated. This paper describes the overall progress of the project, the final design of the cryomagnet, and the performance of the most recent models. Furthermore, the overall plan toward the fabrication of the series magnets for the two phases of the upgrade of the LHC collimation system is also presented.

43 PARTICLE ACCELERATORS↗

The Design of B1APF Dipole for the EIC

Brookhaven National Laboratory has been chosen to host the Electron-Ion Collider (EIC). Part of this is to install an additional electron ring to the existing RHIC tunnel. The electron hadron Interaction Region (IR) will host nine superconducting magnets on the forward side and six superconducting magnets on the rear side of the Interaction Point (IP). B1APF dipole is the last magnet of the near IR in the outgoing hadron direction. Further, the magnet has a physical aperture of 370 mm diameter and is 1.5 m long. This large aspect ratio makes this magnet particularly challenging. It is a collared magnet and uses a NbTi Rutherford cable with 15.1 mm X 1.9 mm. It is expected to operate at a maximum current of 13400 A at 2 K. The required integrated dipole field is 4.05 Tm. This paper discusses the current design status of the B1ApF dipole and presents the electromagnetic analysis and thermal quench propagation analysis.

43 PARTICLE ACCELERATORS↗