Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerator Magnets”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Medium grain niobium SRF cavity production technology for science frontiers and accelerator applications

Herein we present the cost-effective production of superconducting radio frequency (SRF) cavities made of medium grain (MG) niobium (Nb) discs directly sliced from forged and annealed billet. This production method provides clean surface conditions and reliable mechanical characteristics with sub-millimeter average grain size resulting in stable SRF cavity production. We propose to apply this material to particle accelerator in the science and industrial applications. The science applications require high field gradients(≥ 30 MV/m) particularly in pulsed mode. The industrial applications require high $Q_0$ values with moderate gradients (~ 20 MV/m) in CW mode operation. This paper describes the MG Nb disc production recently demonstrated and discusses future prospects for application in advanced particle accelerators in the science and industrial applications.

47 OTHER INSTRUMENTATION↗

Flux Creep in a Bi-2212 Rutherford Cable for Particle Accelerator Applications

Bi-2212 superconducting cables are being considered for use in the high field magnets needed for the next generation of particle accelerators. Magnetization in these cables and the decay of that magnetization lead to field error and field-error drift, respectively, which need to be compensated. To study this, a segment of the winding pack was extracted from a racetrack coil made from Bi-2212 Rutherford cable. Using a Hall probe measurement technique, we measured the response of the cable's magnetization and its magnetization decay to changes in the applied magnetic field. The effect of adjustments to the cycling of the magnetic field was studied, intended to simulate the preinjection cycles of an accelerator magnet. Three M vs. H loops were constructed by sweeping the magnetic field applied to the sample from 0 to 2.5 T, then to a preinjection field 'x' (where x = 0, 0.25, 0.75 T), and finally up to 1 T. The applied field was then held at 1 T for 1500 s, and the magnetization decay was measured. Finally, the decay was found to vary from 8% to 14% after 1500 s, depending on the preinjection field cycle.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electron acceleration in three-dimensional magnetic reconnection with a guide field

Kinetic simulations of 3D collisionless magnetic reconnection with a guide field show a dramatic enhancement of energetic electron production when compared with 2D systems. In the 2D systems, electrons are trapped in magnetic islands that limit their energy gain, whereas in the 3D systems the filamentation of the current layer leads to a stochastic magnetic field that enables the electrons to access volume-filling acceleration regions. The dominant accelerator of the most energetic electrons is a Fermi-like mechanism associated with reflection of charged particles from contracting field lines.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-416: Experimental Evaluation of a Commercial GPU-Based Monte Carlo Dose Calculation Algorithm

Purpose: A new commercial GPU-based Monte Carlo dose calculation algorithm (GPUMCD) developed by the vendor Elekta™ to be used in the Monaco Treatment Planning System (TPS) is capable of modeling dose for both a standard linear accelerator and for an Elekta MRI-Linear accelerator (modeling magnetic field effects). We are evaluating this algorithm in two parts: commissioning the algorithm for an Elekta Agility linear accelerator (the focus of this work) and evaluating the algorithm’s ability to model magnetic field effects for an MRI-linear accelerator. Methods: A beam model was developed in the Monaco TPS (v.5.09.06) using the commissioned beam data for a 6MV Agility linac. A heterogeneous phantom representing tumor-in-lung, lung, bone-in-tissue, and prosthetic was designed/built. Dose calculations in Monaco were done using the current clinical algorithm (XVMC) and the new GPUMCD algorithm (1 mm3 voxel size, 0.5% statistical uncertainty) and in the Pinnacle TPS using the collapsed cone convolution (CCC) algorithm. These were compared with the measured doses using an ionization chamber (A1SL) and Gafchromic EBT3 films for 2×2 cm{sup 2}, 5×5 cm{sup 2}, and 10×10 cm{sup 2} field sizes. Results: The calculated central axis percentage depth doses (PDDs) in homogeneous solid water were within 2% compared to measurements for XVMC and GPUMCD. For tumor-in-lung and lung phantoms, doses calculated by all of the algorithms were within the experimental uncertainty of the measurements (±2% in the homogeneous phantom and ±3% for the tumor-in-lung or lung phantoms), except for 2×2 cm{sup 2} field size where only the CCC algorithm differs from film by 5% in the lung region. The analysis for bone-in-tissue and the prosthetic phantoms are ongoing. Conclusion: The new GPUMCD algorithm calculated dose comparable to both the XVMC algorithm and to measurements in both a homogeneous solid water medium and the heterogeneous phantom representing lung or tumor-in-lung for 2×2 cm{sup 2}-10×10 cm{sup 2} field sizes. Funding support was obtained from Elekta.

60 APPLIED LIFE SCIENCES↗

BOBr Processed Breaking Wave Data, Agate Beach, OR

This data was recorded by the BOBr (Buoy to Observe Breaking) off the coast of Newport, OR at Agate Beach in the surf zone. The data was recorded by a 9dof inertial measurement unit and consists of a timestamp, quaternion orientation, acceleration vector, rotation vector, and magnetic vector. The acceleration, rotation, and magnetic vectors have all been corrected back to a North East Down reference frame.

16 TIDAL AND WAVE POWER↗

MULTIPASS MUON RLA RETURN ARCS BASED ON LINEAR COMBINED-FUNCTION MAGNETS

Recirculating Linear Accelerators (RLA) are an efficient way of accelerating short-lived muons to the multi-GeV energies required for Neutrino Factories and TeV energies required for Muon Colliders. In this paper we present a design of a two-pass RLA return arc based on linear combined function magnets, in which both charge muons with momenta different by a factor of two are transported through the same string of magnets. The arc is composed of 60{sup o}-bending symmetric super cells allowing for a simple arc geometry closing. By adjusting the dipole and quadrupole components of the combined-function magnets, each super cell is designed to be achromatic and to have zero initial and final periodic orbit offsets for both muon momenta. Such a design provides a greater compactness than, for instance, an FFAG lattice with its regular alternating bends and is expected to possess a large dynamic aperture characteristic of linear-field lattices.

43 PARTICLE ACCELERATORS↗

Field Measurement Results of the 15 T Nb 3 Sn Dipole Demonstrator MDPCT1b

A 15 T Nb 3 Sn dipole with cos-theta-type coils was developed to demonstrate a possible magnet design for a post-LHC proton-proton Collider. The magnet has 4-layer coils with 60-mm aperture, and has graded current density between the inner and outer layers to maximize performance. The coils are constrained by vertically-split, thick iron laminations, connected by aluminum Iclamps, and a thick stainless-steel skin. The magnet was previously tested at the Vertical Magnet Test Facility (VMTF) at Fermilab with reduced pre-load, and achieved record 14.1 T fields at maximum current. Now the magnet has been reassembled with full pre-load and has been cryogenically retested at VMTF. We report here on the magnetic measurements results of these tests, including field strength, geometrical harmonics, coil magnetization, and iron saturation characteristics of the demonstrator.

43 PARTICLE ACCELERATORS↗

Simulations of ion acceleration at non-relativistic shocks. I. Acceleration efficiency

We use two-dimensional and three-dimensional hybrid (kinetic ions-fluid electrons) simulations to investigate particle acceleration and magnetic field amplification at non-relativistic astrophysical shocks. We show that diffusive shock acceleration operates for quasi-parallel configurations (i.e., when the background magnetic field is almost aligned with the shock normal) and, for large sonic and Alfvénic Mach numbers, produces universal power-law spectra ∝p {sup –4}, where p is the particle momentum. The maximum energy of accelerated ions increases with time, and it is only limited by finite box size and run time. Acceleration is mainly efficient for parallel and quasi-parallel strong shocks, where 10%-20% of the bulk kinetic energy can be converted to energetic particles and becomes ineffective for quasi-perpendicular shocks. Also, the generation of magnetic turbulence correlates with efficient ion acceleration and vanishes for quasi-perpendicular configurations. At very oblique shocks, ions can be accelerated via shock drift acceleration, but they only gain a factor of a few in momentum and their maximum energy does not increase with time. These findings are consistent with the degree of polarization and the morphology of the radio and X-ray synchrotron emission observed, for instance, in the remnant of SN 1006. We also discuss the transition from thermal to non-thermal particles in the ion spectrum (supra-thermal region) and we identify two dynamical signatures peculiar of efficient particle acceleration, namely, the formation of an upstream precursor and the alteration of standard shock jump conditions.

79 ASTRONOMY AND ASTROPHYSICS↗

Fabrication and Test of a 3.7 m Long Support Structure for the LARP Nb3Sn Quadrupole Magnet LQS01

The 3.7 m long quadrupole magnet LQS01 represents a major step of the US LHC Accelerator Research Program (LARP) towards the development of long Nb{sub 3}Sn accelerator quadrupole magnets for a LHC Luminosity upgrade. The magnet support structure is a scale up of the 1 m long Technology Quadrupole TQS design with some modifications suggested by TQS model test results. It includes an aluminum shell pre-tensioned over iron yokes using pressurized bladders and locking keys (bladder and key technology). The axial support is provided by two stainless steel end plates compressed against the coil ends by four stainless steel rods. The structure, instrumented with strain gauges, has been fabricated and assembled around four aluminum 'dummy coils' to determine pre-load homogeneity and mechanical characteristics during cool-down. After presenting the main magnetic and mechanical parameters of LQS01, we report in this paper on the design, assembly, and test of the support structure, with a comparison between strain gauges data and 3D finite element model results.

43 PARTICLE ACCELERATORS↗

Influence of Ti and Ta doping on the irreversible strain limit of ternary Nb3Sn superconducting wires made by the restacked-rod process

Nb{sub 3}Sn superconducting wires made by the restacked-rod process (RRP{reg_sign}) were found to have a dramatically improved resilience to axial tensile strain when alloyed with Ti as compared to Ta. Whereas Ta-alloyed Nb{sub 3}Sn in RRP wires showed permanent damage to its current-carrying capacity (I{sub c}) when tensioned beyond an intrinsic strain as small as 0.04%, Ti-doped Nb{sub 3}Sn in RRP strands exhibits a remarkable reversibility up to a tensile strain of about 0.25%, conceivably making Ti-doped RRP wires more suitable for the high field magnets used in particle accelerators and nuclear magnetic resonance applications where mechanical forces are intense. A strain cycling experiment at room temperature caused a significant drop of I{sub c} in Ta-alloyed wires, but induced an increase of I{sub c} in the case of Ti-doped strands. Whereas either Ti or Ta doping yield a similar enhancement of the upper critical field of Nb{sub 3}Sn, the much improved mechanical behavior of Ti-alloyed wires possibly makes Ti a better choice over Ta, at least for the RRP wire processing technique.

43 PARTICLE ACCELERATORS↗

PARTICLE ACCELERATION BY COLLISIONLESS SHOCKS CONTAINING LARGE-SCALE MAGNETIC-FIELD VARIATIONS

Diffusive shock acceleration at collisionless shocks is thought to be the source of many of the energetic particles observed in space. Large-scale spatial variations of the magnetic field have been shown to be important in understanding observations. The effects are complex, so here we consider a simple, illustrative model. Here we solve numerically the Parker transport equation for a shock in the presence of large-scale sinusoidal magnetic-field variations. We demonstrate that the familiar planar-shock results can be significantly altered as a consequence of large-scale, meandering magnetic lines of force. Because the perpendicular diffusion coefficient {kappa}{sub perpendicular} is generally much smaller than the parallel diffusion coefficient {kappa}{sub ||}, the energetic charged particles are trapped and preferentially accelerated along the shock front in the regions where the connection points of magnetic field lines intersecting the shock surface converge, and thus create the 'hot spots' of the accelerated particles. For the regions where the connection points separate from each other, the acceleration to high energies will be suppressed. Further, the particles diffuse away from the 'hot spot' regions and modify the spectra of downstream particle distribution. These features are qualitatively similar to the recent Voyager observations in the Heliosheath. These results are potentially important for particle acceleration at shocks propagating in turbulent magnetized plasmas as well as those which contain large-scale nonplanar structures. Examples include anomalous cosmic rays accelerated by the solar wind termination shock, energetic particles observed in propagating heliospheric shocks, galactic cosmic rays accelerated by supernova blast waves, etc.

79 ASTRONOMY AND ASTROPHYSICS↗