Search NASA⌕ Search

SEARCH · Search NASA

Results for “Analytical detection method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

An Experimental Method to Measure Gaseous Diffusivity in Tight and Partially Saturated Porous Media via Continuously Monitored Mass Spectrometry

Detection of radioxenon and radioargon produced by underground nuclear explosions is one of the primary methods by which the Comprehensive Nuclear-Test–Ban Treaty (CTBT) monitors for nuclear activities. However, transport of these noble gases to the surface via barometric pumping is a complex process relying on advective and diffusive processes in a fractured porous medium to bring detectable levels to the surface. To better understand this process, experimental measurements of noble gas and chemical surrogate diffusivity in relevant lithologies are necessary. However, measurement of noble gas diffusivity in tight or partially saturated porous media is challenging due to the transparent nature of noble gases, the lengthy diffusion times, and difficulty maintaining consistent water saturation. Here, the quasi-steady-state Ney–Armistead method is modified to accommodate continuous gas sampling via effusive flow to a mass spectrometer. An analytical solution accounting for the cumulative sampling losses and induced advective flow is then derived. Experimental results appear in good agreement with the proposed theory, suggesting the presence of retained groundwater reduces the effective diffusivity of the gas tracers by 10–1000 times. Finally, by using a mass spectrometer, the method described herein is applicable to a broad range of gas species and porous media.

47 OTHER INSTRUMENTATION↗

Assessment of Impurities in Neptunium Metal Using Double-Focusing SF-ICP-MS

In the transmutation process, minor actinides such as neptunium, americium and curium obtained from spent nuclear fuel are incorporated into new fuel that can be placed into a fast reactor, where these elements fission into products with shorter half-lives which reduces the health and safety hazards. In order to better understand the all the involved processes, fundamental physical properties of actinides should be investigated, and for that reason, high-purity materials need to be produced. One of the main challenges in characterizing these materials is the lack of pure metal available for study, and lack of analytical methods to determine the purity. Trans-uranic elements are challenging to study because of the need to be handled in specialized facilities, safeguards concerns and they are not easily purchased and/or produced. High-purity Np metal is being produced at the Materials and Fuels Complex (MFC) of Idaho National Laboratory (INL), in a process of direct oxide reduction developed by Squires and Lessing, with a target purity of 99.999%. The goal of this research is to develop methods to determine the impurities in the Np metal, with detection limits low enough to achieve this purity level. In this work, we have used several ICP-MS and ICP OES techniques, but the focus was the method development using a recently acquired Double-Focusing Sector Field Inductively Coupled Plasma Mass Spectrometer (SF-ICP-MS). To produce the Np metal, approximately 20 g of the neptunium oxide powder was calcined at 800 oC for 6 h in a magnesium oxide crucible, which is placed inside a stainless steel crucible, that goes into the Hot Uniaxial Press (HUP) furnace insert. After the calcining step, the Np oxide was mixed with approximately 9 g of calcium metal and 100 g of ultra-dry calcium chloride. The HUP furnace was heated in a ramp rate of 50 oC min -1 up to 1000 oC. When the reaction mixture reached 850 oC, a tantalum stirrer was activated at 100 rpm. After the tantalum stirrer was removed and the mixture cooled overnight, the MgO crucible was opened with a hammer and chisel to retrieve the Np metal button at the bottom of the reaction mixture. Prior to the dissolution process, the surface contaminants of the sample were removed. The Np button was washed in 10 mL of ultra-pure water for 1 min, with a faint reaction observed on the surface, indicating the presence of Ca metal. The water-washed sample was placed in a tube with 2 M HCl for only 3 s, as a vigorous reaction in the button surface was observed. The leachates were saved for further analysis. The sample was then rinsed with ultra-pure water and air-dried prior to dissolution. The cleaned sample was placed in a PTFE beaker and 25 mL of 6 M HCl and 150 µL of 24 M HF were added. After 10 minutes of reaction, the beaker was placed on a hot plate for 1 h and 30 min, followed by the addition of 1 mL of 16 M HNO3 and allowed to react for a further 1 h and 20 min. The sample was removed from heat and 10 mL of HNO3 16 M was added to react with the HCl. The beaker was covered and left for overnight reaction, producing a solution with approximately 20 mL of final volume. A Quadrupole Inductively Coupled Plasma Mass Spectrometer (Q-ICP-MS, Perkin Elmer ELAN DRC II Q-ICP-MS) was used to obtain qualitative mass spectra for the dissolution blank, each of the leachates and the dissolved sample. In the water leachate spectrum mainly Ca and Mg were observed, while the acid wash had a similar peak pattern to the one observed for the Np metal sample, indicating that the process not only removed surface contamination, but also reacted with the sample itself. In the Np material spectrum, Ta and actinides were identified as candidates for major contaminants, as the most intense peaks corresponded to the mass-to-charge ratios of these elements. Minor contaminants included Al, Au, Ca, Cr, Fe, I, Na, Nb, Pb, Sn, Ti, Tl, V, Y. The presence of impurities in the material could have originated from several sources, such as the materials used for the casting process, the use of impure NpO2 or contamination of reagents and materials used for the analysis. Some of the isotopes listed as potential contaminants are susceptible to spectral interferences, so Double-Focusing SF-ICP-MS (Nu Instruments Attom ES HR-ICP-MS) was used for the quantitative analysis. For each isotope determined, several items were evaluated: raw signal of a blank solution, sensitivity and determination coefficient of calibration curves, possibility of interferences and comparison of results obtained for at least two resolving powers (RP): 300 and 4000. The evaluation of the signal in a blank solution can indicate if a spectral interference from the plasma gas and/or the solvent was successfully resolved (commonly observed for 52Cr+/40Ar12C+, for example). It is important to highlight that a signal reduction is expected when a higher RP is used, as the ion beam transmission is decreased by the use of narrower slits

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of small island characteristics using high resolution ECE and CER at DIII-D

Abstract The measurements using the high resolution electron cyclotron emission radiometry and the charge exchange and recombination spectroscopy are processed using analytic formulas to allow for the detection of islands as small as 1.9 cm. In contrast to large, saturated magnetic islands which are relatively well understood to be governed by the loss of bootstrap current inside the island, small islands are less well understood due to the difficulty of their accurate measurement in tokamaks. Here, ‘small’ islands are islands comparable in size to the ion banana width, which can be as small as 0.8 cm at DIII-D. The new measurement methods allow for the detection of small island widths when the predicted increase of mode frequency to match the Doppler shifted ion diamagnetic frequency is observed. Therefore, for the first time, the mode frequency increase can be unambiguously associated to the acceleration of the magnetic island propagation. Such association allows for a further development and validation of the much-debated theory of ion polarization currents, which is thought to govern the small island growth.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High efficiency active environmental sampling of chemical traces

A method of sample collection includes collecting an analyte from a sampling surface using a rapidly curable liquid gel comprising one or more metal particles; co-aggregating the one or more metal particles from the rapidly curable liquid gel and the analyte from the sampling surface; and rapidly curing the rapidly curable liquid gel. The composition and sample preparation conditions may facilitate improved collection efficiency of analytes during environmental and forensic evidence sampling. In addition, the composition and sample preparation conditions may facilitate enhanced detection and identification of the analyte using e.g., Surface Enhanced Raman Spectrometry (SERS).

Junghans, Ann↗

GC/MS Method Development for Separating Lunar Volatile Ice Simulant Headspace Gases

Various investigators propose the lunar surface contains widely distributed volatiles, especially water- like species, i.e. OH and H2O. Surface volatiles are theorized to exist as a hydrated regolith layer, concentrated in extremely cold polar permanently shadowed regions (PSR), and/or solar wind implantation reservoirs in lunar glasses. The proposed sources of lunar surface volatiles range from cometary impacts, solar wind, or a supply present during moon formation. Future Artemis missions aim to collect and return the samples containing volatiles collected near lunar polar craters or PSRs. We, as advanced curation scientists, are responsible for developing techniques and methodologies for preserving returned sample integrity as much as possible. Pristine volatile-bearing samples are invaluable to the scientific community seeking to unravel the history of the solar system. Realistically, a sample will experience alteration during collection, transportation back to earth, and storage. The Planetary Exploration and Astromaterials Research Lab (PEARL) seeks to understand temperature and pressure effects on high-fidelity volatile-containing regolith simulants, the foundation for the future of cold curation. This abstract outlines the separation, identification, and quantification of headspace gases over volatile ice feed stock material using gas chromatography/mass spectrometry (GC/MS). Preliminary objectives concentrated on sample handling, reproducibility, and understanding the elution characteristics for each analyte. Initial GC/MS method development experiments utilized diluted static headspace sample preparation. Diluted samples were used because sampling headspace gases directly from a vial containing liquid analyte resulted in overloading of the column and detector. Overloading is evident based on chromatogram peak shapes and instrument contamination, or carry over, between experiments. A mixture of three alcohols were used for a majority of the sample handling and reproducibility studies. Reproducibility was tested via multiple users, calibration curves, and check standards. Stock solutions of condensed lunar volatile analytes included methanol, ammonia in methanol, hydrogen sulfide in water, and an equal volume mixture of methanol, ethanol, and isopropanol. Current samples use room air as the headspace sample matrix, however future experiments will incorporate an inert purge gas, such as argon or nitrogen. Three mL of each analyte solution were capped in separate 20 mL crimp top GC vials. Dilutions were carried out by removing an aliquot of headspace gases with a calibrated 1 mL gastight syringe and immediately transferring to a 20 mL capped crimp top vial. The GC/MS is a Thermo Fisher Trace 1310/ISQ 7000 with a TriPlus RSH autosampler and split/splitless injector module. The experiments outlined in this abstract use the following hardware: a 2.5 mL gastight headspace syringe tool, 1 mm ID x 78.5 mm length ultra-inert straight injection liner, and a TG-BondQ 30 m × 0.32 mm × 10 μm column. Various parameters, such as hardware selection and the temperature, pressure, and split ratio set points, continue to evolve as the overall experiment is refined. Diluted headspace chromatograms were collected for the individual stock solutions. Retention times, peak shapes, and mass spectra were evaluated and added to the data processing method for each molecule of interest. Figure 1 shows the total ion chromatograms for the three major lunar volatile simulant stock solutions: methanol, 7 N ammonia in methanol, and 0.4% hydrogen sulfide in water. Tailing peak shapes for ammonia (2.98 min rt) and water (4.06 min rt) indicate the molecules are not properly eluting from the selected column with the current separation method. Additionally, hydrogen sulfide and ammonia have overlapping peak windows, which could impact quantification. Ongoing experiments aim to address the peak shape and overlapping via the separation method and hardware selection. Sample preparation reproducibility experiments used stock solution containing equal volumes of a non- interactive mixture of methanol, ethanol, and isopropanol. Mass spectrum ion traces were used to identify and quantify all three alcohols. Peaks were automatically detected, identified, and integrated through the mass spectra detection and processing parameters. Calibration response curves and check standards were used to evaluate the validity of the sample preparation procedure. Figure 2 shows the methanol chromatogram peak area versus total headspace dilution volume transferred from the alcohol mixture vial. The calibration response curves and check standards validate sample preparation procedure. Continuing data analysis efforts are working towards correlating the peak area and instrument response factor to the headspace analyte concentration and condensed phase composition. Static headspace gas chromatography theory relies on Dalton’s law, Raoult’s law, Henry’s Law, and the Kolb and Ettre equation to associate peak area to the analyte composition in a non-ideal solution. Equation 1 is a simplified expression derived from the aforementioned theories. Future experiments involve liquid injections of the individual stock solutions, liquid and headspace analysis of various stock solution combinations, and the addition of regolith simulants to the mixtures. Temperature is another variable expected to affect reaction rates and will be explored.

Cecilia L. Amick↗

Quadrupole and multi-collector ICP-MS analysis of 226 Ra in brain from a radium dial painter

We report two ICP-MS methods were developed to measure the radiotoxic isotope 226 Ra in brain tissues from a radium dial painter worker. The first method was a direct analysis of acid digested samples using quadrupole ICP-MS. The instrumental LOD of 226 Ra was 0.1 ng kg -1 . Polyatomic interferences at m/z 226 were investigated and Pb was identified from a polyatomic interferent in an in-house sample prepared from bovine brain, with a 226/208 formation ratio of 4 × 10 -8 . The quadrupole ICP-MS method was also used to measure levels of beryllium, strontium, and uranium. A second method was developed that included cation-exchange chromatography to separate 226 Ra followed by analysis with sector field MC-ICP-MS. The instrumental LOD for the cation exchange method with MC-ICP-MS detection was 0.5 pg kg -1 (19 mBq kg -1 ). The measured concentrations of 226 Ra in different brain regions ranged from 0.09–0.72 ng kg -1 (3.3–27 Bq kg -1 ) and radium was non-uniformly distributed in the brain.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Isomer-specific spectroscopy of aromatics and their resonance-stabilized radical intermediates

There are many circumstances in which complex gas-phase reaction mixtures must be interrogated and understood, including combustion, plasmas, atmospheres, and molecular clouds. Spectroscopic tools are essential to selective detection and characterization of the widening array of precursors and the reactive intermediates they generate. This research program has focused on the development and implementation of sensitive spectroscopic detection schemes that are isomer-specific and even conformation-specific. In particular, we used an array of laser-based and broadband microwave methods to carry out isomer-specific and conformation-specific spectroscopy on large flexible molecules and reactive intermediates formed by photolysis, pyrolysis, combustion, or electron-driven chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tackling the Challenges in Scene Graph Generation With Local-to-Global Interactions

In this work, we seek new insights into the underlying challenges of the scene graph generation (SGG) task. Quantitative and qualitative analysis of the visual genome (VG) dataset implies: 1) ambiguity: even if interobject relationship contains the same object (or predicate), they may not be visually or semantically similar; 2) asymmetry: despite the nature of the relationship that embodied the direction, it was not well addressed in previous studies; and 3) higher-order contexts: leveraging the identities of certain graph elements can help generate accurate scene graphs. Motivated by the analysis, we design a novel SGG framework, Local-to-global interaction networks (LOGINs). Locally, interactions extract the essence between three instances of subject, object, and background, while baking direction awareness into the network by explicitly constraining the input order of subject and object. Globally, interactions encode the contexts between every graph component (i.e., nodes and edges). Finally, Attract and Repel loss is utilized to fine-tune the distribution of predicate embeddings. By design, our framework enables predicting the scene graph in a bottom-up manner, leveraging the possible complementariness. To quantify how much LOGIN is aware of relational direction, a new diagnostic task called Bidirectional Relationship Classification (BRC) is also proposed. Overall, experimental results demonstrate that LOGIN can successfully distinguish relational direction than existing methods (in BRC task), while showing state-of-the-art results on the VG benchmark (in SGG task).

97 MATHEMATICS AND COMPUTING↗

Visible absorbance spectra: A basis for in situ and passive remote sensing of phytoplankton concentration and community composition

The concentration and composition of phytoplankton populations are measured by an optical method which can be used either in situ or remotely. This method is based upon the in vivo light absorption characteristics of phytoplankton. To provide a data base for testing assumptions relative to the proposed method, visible absorbance spectra of pure cultures of 20 marine phytoplankton were obtained under laboratory conditions. Descriptive and analytical statistics were computed for the absorbance spectra and were used to make comparisons between members of major taxonomic groups and between groups. Spectral variation between the members of the major taxonomic groups was observed to be considerably less than the spectral variation between these groups. In several cases the differences between the mean absorbance spectra of major taxonomic groups are significant enough to be detected with passive remote sensing techniques.

Farmer, F. H.↗

Tag you're it: Application of stable isotope labeling and LC-MS to identify the precursors of specialized metabolites in plants

Untargeted liquid chromatography/mass spectrometry (LC-MS) can contribute a comprehensive and unbiased picture of the metabolic space of plants. These data can be used to quantify natural metabolite variation for genome wide association studies, to compare global metabolic responses from environmental or genetic perturbations, and to identify previously undescribed metabolites in Nature. A major limitation with untargeted metabolomics is the classification and identification of the thousands of metabolite features that can be detected in a single analytical run. Isotopic labeling improves the informational value of these datasets by categorizing metabolites as being derived from specific upstream precursors and/or to known metabolic pathways. When a 13 C-labeled precursor is fed to either a plant or tissue, the downstream metabolites produced from it have a higher m/z value than the molecules in the pre-existing pool, generating an m/z peak pair that can be specifically identified within the MS data. In this paper, we outline methods and principles to consider when supplementing untargeted MS data with isotopic labeling, including how to choose the appropriate isotopic label, grow and feed plant tissues to maximize label uptake and incorporation into derivatives, optimize LC-MS methods, and interpret the resulting labeling data. Although the focus here is on annotation of amino acid-derived metabolites using LC-MS, we anticipate that the methods are generally adaptable to other precursors, plant species, and chromatographic approaches.

59 BASIC BIOLOGICAL SCIENCES↗

A machine learning photon detection algorithm for coherent x-ray ultrafast fluctuation analysis

X-ray free electron laser experiments have brought unique capabilities and opened new directions in research, such as creating new states of matter or directly measuring atomic motion. One such area is the ability to use finely spaced sets of coherent x-ray pulses to be compared after scattering from a dynamic system at different times. This enables the study of fluctuations in many-body quantum systems at the level of the ultrafast pulse durations, but this method has been limited to a select number of examples and required complex and advanced analytical tools. By applying a new methodology to this problem, we have made qualitative advances in three separate areas that will likely also find application to new fields. As compared to the “droplet-type” models, which typically are used to estimate the photon distributions on pixelated detectors to obtain the coherent x-ray speckle patterns, our algorithm achieves an order of magnitude speedup on CPU hardware and two orders of magnitude improvement on GPU hardware. We also find that it retains accuracy in low-contrast conditions, which is the typical regime for many experiments in structural dynamics. Finally, it can predict photon distributions in high average-intensity applications, a regime which up until now has not been accessible. Our artificial intelligence-assisted algorithm will enable a wider adoption of x-ray coherence spectroscopies, by both automating previously challenging analyses and enabling new experiments that were not otherwise feasible without the developments described in this work.

47 OTHER INSTRUMENTATION↗

Development of a Universal Second-Tier Newborn Screening LC–MS/MS Method for Amino Acids, Lysophosphatidylcholines, and Organic Acids

First-tier MS-based newborn screening by flow injection analysis can have high presumptive positive rates, often due to isomeric/isobaric compounds or poor biomarker specificity. These presumptive positive samples can be analyzed by second-tier screening assays employing separations such as liquid chromatography–mass spectrometry (LC–MS/MS), which increases test specificity and drastically reduces false positive referrals. The ability to screen for multiple disorders in a single multiplexed test simplifies workflows and maximizes public health laboratories’ resources. In this study, we developed and validated a highly multiplexed second-tier method for dried blood spots using a hydrophilic interaction liquid chromatography (HILIC) column coupled to an MS/MS system. The LC–MS/MS method was capable of simultaneously detecting second-tier biomarkers for maple syrup urine disease, homocystinuria, methylmalonic acidemia, propionic acidemia, glutaric acidemia type 1, glutaric acidemia type 2, guanidinoacetate methyltransferase deficiency, short-chain acyl-CoA dehydrogenase deficiency, adrenoleukodystrophy, and Pompe disease.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Managing photon flux in a miniaturized photoionization detector

Miniaturized photoionization detectors (PIDs) are used in conjunction with gas chromatography systems to detect volatile compounds in gases by collecting the current from the photoionized gas analytes. PIDs should be inexpensive and compatible with a wide range of analyte species. One such PID is based on the formation of a He plasma in a dielectric barrier discharge (DBD), which generates vacuum UV (VUV) photons from excited states of He to photoionize gas analytes. There are several design parameters that can be leveraged to increase the ionizing photon flux to gas analytes to increase the sensitivity of the PID. To that end, the methods to maximize the photon flux from a pulsed He plasma in a DBD-PID were investigated using a two-dimensional plasma hydrodynamics model. The ionizing photon flux originated from the resonance states of helium, He(3P) and He(2 1 P), and from the dimer excimer He 2 *. While the photon flux from the resonant states was modulated over the voltage pulse, the photon flux from He 2 * persisted long after the voltage pulse passed. Several geometrical optimizations were investigated, such as using an array of pointed electrodes. However, increasing the capacitance of the dielectric enclosing the plasma chamber had the largest effect on increasing the VUV photon fluence to gas analytes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Health Monitoring of a Rotating Disk Using a Combined Analytical-Experimental Approach

Rotating disks undergo rigorous mechanical loading conditions that make them subject to a variety of failure mechanisms leading to structural deformities and cracking. During operation, periodic loading fluctuations and other related factors cause fractures and hidden internal cracks that can only be detected via noninvasive types of health monitoring and/or nondestructive evaluation. These evaluations go further to inspect material discontinuities and other irregularities that have grown to become critical defects that can lead to failure. Hence, the objectives of this work is to conduct a collective analytical and experimental study to present a well-rounded structural assessment of a rotating disk by means of a health monitoring approach and to appraise the capabilities of an in-house rotor spin system. The analyses utilized the finite element method to analyze the disk with and without an induced crack at different loading levels, such as rotational speeds starting at 3000 up to 10 000 rpm. A parallel experiment was conducted to spin the disk at the desired speeds in an attempt to correlate the experimental findings with the analytical results. The testing involved conducting spin experiments which, covered the rotor in both damaged and undamaged (i.e., notched and unnotched) states. Damaged disks had artificially induced through-thickness flaws represented in the web region ranging from 2.54 to 5.08 cm (1 to 2 in.) in length. This study aims to identify defects that are greater than 1.27 cm (0.5 in.), applying available means of structural health monitoring and nondestructive evaluation, and documenting failure mechanisms experienced by the rotor system under typical turbine engine operating conditions.

Abdul-Aziz, Ali↗

Diol isomer revealed as a source of methyl ketene from propionic acid unimolecular decomposition

Carboxylic acids are important combustion intermediates, especially regarding the combustion of oxygenates such as ethyl esters. The purpose of this study is to discern the unimolecular decomposition pathways of one such carboxylic acid, propionic acid, using microreactor flow experiments with line-tunable photoionization mass spectrometry and infrared spectroscopy, along with high-level electronic structure calculations (CCSD(T)/cc-pV∞Z//M06-2X/cc-pVTZ level of theory) and master equation theory. Here, microreactor experiments were performed at 300–1500 K, pressures decreasing from roughly 300 Torr to vacuum pressure, and around 100 μs residence times. Primary products are methyl ketene, ketene, ethylene, and methyl radical. Theory suggests the two lowest energy bond fissions are active at these conditions and responsible for the production of ketene, methyl radical, and some ethylene. Importantly, theory revealed the significance of the isomerization of propionic acid to propene-1,1-diol, and the subsequent dehydrogenation reaction of the diol as an alternative explanation for the unimolecular formation of methyl ketene. This is predicted to be the dominant thermal decomposition pathway at lower temperatures (up to ~850 K). Line-tunable VUV photons allowed for isomer resolution of the products and showed no evidence of the diol of propionic acid surviving until detection, suggesting propene-1,1-diol decomposes either to methyl ketene and water rapidly, fragments upon ionization to a distonic ion inseparable from methyl ketene through our detection methods, or never stabilizes as propionic acid well-skips directly to methyl ketene. Infrared spectroscopy showed no evidence of the decarboxylation of propionic acid at these conditions. Updated rate constants and branching ratios for propionic acid decomposition are calculated and provided for future modeling studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In-situ Detection of Glovebox Glove Degradation Prior to Glove Failure; Effects on Safety, Waste, and Operational Costs - 20402

Glovebox glove pressure decay leak testing and analysis of the data can greatly improve glovebox safety, minimize Transuranic (TRU) glove waste, and minimize operational cost. It is well known, the weakest point of containment on a glovebox is the glove. Mitigating unplanned openings in gloves is critical to minimizing operational and safety costs in glovebox operations. Mitigating unplanned glove openings due to glove failures will be discussed in this paper. The lack of an engineered solution to determine a gloves operational life in nuclear operations, has lead to use of theoretical and manual subjective methods to determine the life and safety of a glovebox glove. Whether the glove is inspected visually prior to use, or gloves are changed regularly to theoretically avoid failure, both the operators PPE and the room are being exposed to contamination, or un-necessary amounts of TRU glove waste are being generated. Millions of dollars yearly in operational costs are spent on glove failures due to loss of production, incident analysis, regulatory audits, clean up, and paperwork. In a nuclear application, a glove failure could contaminate an operator and laboratory, shut down the operation for weeks, potentially create a regulatory audit, and potentially create a media frenzy; the damages to the organization can be astronomical. Elimination of glove failures is possible by tracking glove material degradation and setting limits to allow glove change when it becomes necessary, prior to glove failure. Analytical pressure decay leak testing allows the detection of material degradation, and in turn the ability to limit operational glove failures. A German based company called MK Versuchsanlagen, e.K., has developed an advanced Glove Integrity Testing System. The system, with its use of proprietary RFID and special software technology, is unique in its capabilities. The system is capable to perform highly accurate regular glove testing on any size glovebox line in minimal time. The system records and can analyze a tremendous amount of system data that in turn can determine, for example, a safe glove change time prior to a glove material failure. This paper will show how an advanced Glove Integrity Testing System can detect glove material degradation and help determine a safe change point prior to glove failure. Pressure decay curves of new gloves and recorded effects of accelerated aging on the glove over time will be shown. The use of this technology in nuclear facilities can greatly improve glovebox operational safety, minimize glovebox glove TRU waste, and save organizations tremendous costs in downtime, clean up, documentation, and potential regulatory review. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Observability during planetary approach navigation

The objective of the research is to develop an analytic technique to predict the relative navigation capability of different Earth-based radio navigation measurements. In particular, the problem is to determine the relative ability of geocentric range and Doppler measurements to detect the effects of the target planet gravitational attraction on the spacecraft during the planetary approach and near-encounter mission phases. A complete solution to the two-dimensional problem has been developed. Relatively simple analytic formulas are obtained for range and Doppler measurements which describe the observability content of the measurement data along the approach trajectories. An observability measure is defined which is based on the observability matrix for nonlinear systems. The results show good agreement between the analytic observability analysis and the computational batch processing method.

Bishop, Robert H.↗

Machine Learning Approaches for Nuclear Material Accounting Data from Irradiation and Reprocessing

We are currently exploring data analysis methods for their ability to strengthen the synthesis and evaluation of information generated within domestic and international safeguard regimes. Safeguard data typically includes rich heterogenous datasets amenable to advanced data analytics methods, such as machine learning. We have converted transactional data containing both numerical and categorical attributes from a domestic nuclear material control and accountability (NMC&A) system into a low-dimensional numerical structure via linear principal component analysis. This data representation allows for global structure discovery via cluster analysis, which can characterize the typical behavior of each of the primary types of transaction events. Furthermore, the structure of the top principal components captures the “typical behavior” of the data and is thus amenable to anomaly detection through statistical hypothesis testing. We explored this capability by generating erroneous permutations of the data and computing the Q-residual quantity increase associated with the information loss when these data are projected into the low-dimensional principal component analysis space representative of typical transactions.Future work will focus on identifying data transformations (e.g., graph networks) that more closely align with the inherent structure of these transactions to explain more salient information and disambiguate the underlying nuclear process—in this case, irradiation and reprocessing—from artifacts of NMC&A system transactional record keeping data.

Drescher, Adam↗