Search NASA⌕ Search

SEARCH · Search NASA

Results for “Atomic measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Precise Q value determinations for forbidden and low energy $\beta $-decays using Penning trap mass spectrometry

Nuclear β-decay provides a laboratory for investigating weak decays occurring inside the nuclear medium. This provides information on the resulting subtle nuclear and atomic effects, and on the underlying interaction and the properties of the particles that are involved, particularly of the neutrino. The Q value of the decay corresponds to the energy equivalent of the mass difference between parent and daughter atoms, and can be precisely and accurately measured using Penning trap mass spectrometry. In this paper we discuss Penning trap Q value measurements for forbidden β-decays of long-lived primordial nuclides, and for a subset of β-unstable nuclides that could potentially undergo a very low energy decay to an excited state in the daughter nucleus. Here we discuss applications of these measurements to tests of systematics in detectors that perform precise β-spectrum measurements, as inputs for theoretical shape factor, electron branching ratio and half-life calculations, and to identify nuclides that could serve as new candidates in direct neutrino mass determination experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Measurement of the Eta Meson Radiative Decay Width via the Primakoff Effect

The ? meson is an interesting tool to study fundamental symmetries in Quantum Chromodynamics (QCD). In particular, its radiative decay width, ? p? Ñ ??q, is an important quantity that can be predicted in the framework of Chiral Perturbation Theory. A precision measurement of this quantity would provide critical inputs to understanding the mixing of the ? and ?1 mesons and extracting constants with wide-ranging applications in low-energy QCD. This decay width has been measured in the past using two different experimental techniques. The more popular technique utilized e`e´ collisions to produce ? mesons through electromagnetic interactions. Today, the Particle Data Group (PDG) averages the results of five such experiments to obtain their currently-accepted value of the decay width as: 0.515?0.018 keV. However the first measurement of this quantity was obtained from a fixed-target experiment that measured the cross section for photoproduction of ? mesons on a nuclear target via the Primakoff effect. Their result of 0.324?0.046 keV shows strong tension with the average of the collider measurements, motivating a new, high precision measurement using the Primakoff method. For this purpose, the PrimEx-eta experiment was conducted in Hall D of the Thomas Jefferson National Accelerator Facility (Jefferson Lab or JLab). The data is currently being analyzed to measure the differential cross section for the photoproduction of ? mesons on a liquid, 4He target. Preliminary results obtained from the analysis of the first phase of the PrimEx-eta experiment show reasonable agreement with the currently-accepted PDG value of the radiative decay width. However, as will be discussed, there are many challenges to this precision measurement which must be studied before any results can be finalized and compared with previous measurements. In parallel to the ? decay width measurement, the PrimEx-eta experiment measured the total cross section for the fundamental, Quantum Electrodynamics (QED) process of Compton scattering from the atomic electrons inside the target. The results obtained from this measurement are in strong agreement with the next-to-leading order QED calculations, and the total combined uncertainties are below 3% for incident photon energies between 7-10 GeV. In addition to providing the first precision measurement of the total Compton scattering cross section within this beam energy range, this measurement verifies the capability of the PrimEx-eta experimental setup to perform absolute cross section measurements at forward angles, and serves as a reference process for the calibration of systematic uncertainties.

Smith, Andrew↗

High-precision mass measurement of 103 Sn restores smoothness of the mass surface

As a step towards the ultimate goal of a high-precision mass measurement of doubly magic 100 Sn, the mass of 103 Sn was measured at the Low Energy Beam and Ion Trap (LEBIT) located at the Facility for Rare Isotope Beams (FRIB). Utilizing the time-of-flight ion cyclotron resonance technique, a mass uncertainty of 3.7 keV was achieved, an improvement by more than an order of magnitude compared to a recent measurement performed in 2023 at the Cooler Storage Ring (CSRe) in Lanzhou. Although the LEBIT and CSRe mass measurements of 103 Sn are in agreement, they diverge from the experimental mass value reported in the 2016 version of the Atomic Mass Evaluation (AME2016), which was derived from the measured 𝑄 𝛽 + value and the mass of 103 In. In AME2020, this indirectly measured 103 Sn mass was classified as a “seriously irregular mass” and replaced with an extrapolated value, which aligns with the most recent measured values from CSRe and LEBIT. As such, the smoothness of the mass surface is confidently reestablished for 103 Sn. Here, LEBIT's mass measurement of 103 Sn enabled a significant reduction in the mass uncertainties of five parent isotopes which are now dominated by uncertainties in their respective 𝑄 values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New method for level-lifetime measurements with thick scintillators

Level lifetimes provide key insight into the structure of atomic nuclei and serve as stringent tests of theoretical descriptions. Though several methods for determining level lifetimes exist for both reaction measurements and decay studies, here the focus is on techniques involving the direct measurement of time differences between population and subsequent depopulation of excited states. The techniques presented herein are broadly applicable across multiple timing ranges, but the approach is specifically described for the βγ timing method. A multi-step, amplitude-dependent time walk correction was employed to address the data analysis complications that arise from using thick scintillators for electron detection. Further, additional corrections for the depth of the interaction must also be performed when the parent isotope has been implanted into the detector. Techniques are presented for performing these time walk and depth of interaction corrections. Subsequently, a new Monte Carlo method utilizing measured detector responses obtained from the data, coupled with chi-square minimization, is presented for extracting excited state lifetimes ≳ 100 picoseconds. The framework of this Monte Carlo method is developed for the decay of a state in 68 Zn with a known 1.6 ps half life, which is considered prompt given the detection sensitivity of the technique, and then benchmarked using two other excited states in neutron-rich Ni isotopes with 120(34) ps and 1.05(3) ns half lives. Using this new method which takes into account the thick scintillator used, these same half lives were measured to be 135(10) ps and 1.04(24) ns, respectively. The overall good agreement demonstrates the validity of the technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-dimensional ferromagnetism and magnetotransport in van der Waals Mn-intercalated tantalum disufide

Van der Waals (vdW) ferromagnets are an important class of materials for spintronics applications. The recent discovery of atomically vdW magnets CrI 3 and Cr 2 Ge 2 Te 6 has triggered a renaissance in the area of two-dimensional (2D) magnetism. Herein we systematically studied 2H-Mn 0.28 TaS 2 single crystal, a 2D vdW ferromagnet with T c ~ 82.3K, and a large in-plane magnetic anisotropy. Mn K-edge x-ray absorption spectroscopy was measured to provide information on its electronic state and local atomic environment. The detailed magnetic isotherms measured in the vicinity of T c indicates that the spin coupling inside 2H-Mn 0.28 TaS 2 is of a 3D Heisenberg type coupled with the attractive long-range interaction between spins that decay as J(r) ≈ r –4.85 . Both resistivity ρ(T) and thermopower S(T) exhibit anomalies near T c , confirming that the hole-type transport carriers strongly interact with local moments. Furthermore, an unusual angle-dependent magnetoresistance is further observed, suggesting a possible field-induced novel magnetic structure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Adaptive Pore Opening to Form Tailored Adsorption Sites in a Cooperatively Flexible Framework Enables Record Inverse Propane/Propylene Separation

A proposed low-energy alternative to the separation of alkanes from alkenes by energy-intensive cryogenic distillation is separation by porous adsorbents. Unfortunately, most adsorbents preferentially take up the desired, high-value major component alkene, requiring frequent regeneration. Adsorbents with inverse selectivity for the minor component alkane would enable the direct production of purified, reagent-grade alkene, greatly reducing global energy consumption. However, such materials are exceedingly rare, especially for propane/propylene separation. Here, we report that through adaptive and spontaneous pore size and shape adaptation to optimize an ensemble of weak noncovalent interactions, the structurally responsive metal-organic framework CdIF-13 (sod-Cd(benzimidazolate) 2 ) exhibits inverse selectivity for propane over propylene with record-setting separation performance under industrially relevant temperature, pressure, and mixture conditions. Powder synchrotron X-ray diffraction measurements combined with first-principles calculations yield atomic-scale insight and reveal the induced fit mechanism of adsorbate-specific pore adaptation and ensemble interactions between ligands and adsorbates. Dynamic column breakthrough measurements confirm that CdIF-13 displays selectivity under mixed-component conditions of varying ratios, with a record measured selectivity factor of α ≈ 3 at 95:5 propylene:propane at 298 K and 1 bar. When sequenced with a low-cost rigid adsorbent, we demonstrated the direct purification of propylene under ambient conditions. In conclusion, this combined atomic-level structural characterization and performance testing firmly establishes how cooperatively flexible materials can be capable of unprecedented separation factors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hexamethyldisiloxane pyrolysis: probing H-atom initiation by femtosecond two-photon LIF

Previous experiments have led to the hypothesis that pyrolysis of silica nanoparticle precursors carried in an inert central gas jet surrounded by a laminar flame is initiated not by thermal decomposition (the measured jet temperatures are too low for pyrolysis), but by reactions with H-atoms diffusing from the surrounding flame into the jet. The current work tests this hypothesis using femtosecond two-photon laser-induced fluorescence (fs-TPLIF) to image H-atom concentrations in the same flame configuration as the previous experiments. Methane flames (ϕ = 0.83, 1.01 and 1.13) were generated using a multi-element diffusion (Hencken) burner equipped with a central tube through which the N2 jet was introduced. The fs-TPLIF line imaging showed significant concentrations of H-atoms in the nitrogen jets at heights above the burner (HAB) close to the methane flame front. The measurements indicate radial diffusion of the H atoms from the flame to the jet is significant. The H-atom concentrations in the jet increased with increasing stoichiometry of the methane flame. Additional experiments were performed with hexamethyldisiloxane entrained in the central jet flow. In each case, a diffusion flame producing silica nanoparticles was established at the boundaries between the central jet and the methane flames. The 2D H-atom images showed a transition from over-ventilated diffusion flames to under-ventilated diffusion flames with increasing equivalence ratio. Furthermore, the fs-TPLIF profiles show a significant production of H-atoms within the jet when the surrounding flame is lean. This knowledge contributes to a deeper understanding of the underlying mechanisms governing these synthesis flame systems and opens avenues for advancing silica nanoparticle synthesis techniques.

Kim, Keunsoo↗

Resonant X-ray excitation of the nuclear clock isomer 45 Sc

Resonant oscillators with stable frequencies and large quality factors help us to keep track of time with high precision. Examples range from quartz crystal oscillators in wristwatches to atomic oscillators in atomic clocks, which are, at present, our most precise time measurement devices. The search for more stable and convenient reference oscillators is continuing. Nuclear oscillators are better than atomic oscillators because of their naturally higher quality factors and higher resilience against external perturbations. One of the most promising cases is an ultra-narrow nuclear resonance transition in 45 Sc between the ground state and the 12.4-keV isomeric state with a long lifetime of 0.47 s (ref. 10 ). The scientific potential of 45 Sc was realized long ago, but applications require 45 Sc resonant excitation, which in turn requires accelerator-driven, high-brightness X-ray sources that have become available only recently. Here we report on resonant X-ray excitation of the 45 Sc isomeric state by irradiation of Sc-metal foil with 12.4-keV photon pulses from a state-of-the-art X-ray free-electron laser and subsequent detection of nuclear decay products. Simultaneously, the transition energy was determined as ${\mathrm{12,389.59}}_{+0.12\left({\rm{syst}}\right)}^{\pm 0.15\left({\rm{stat}}\right)}\,{\rm{eV}}$ with an uncertainty that is two orders of magnitude smaller than the previously known values. These advancements enable the application of this isomer in extreme metrology, nuclear clock technology, ultra-high-precision spectroscopy and similar applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Local ordering in Ge/Ge–Sn semiconductor alloy core/shell nanowires revealed by extended x-ray absorption fine structure (EXAFS)

Short-range atomic order in semiconductor alloys is a relatively unexplored topic that may promote design of new materials with unexpected properties. Here, local atomic ordering is investigated in Ge–Sn alloys, a group-IV system that is attractive for its enhanced optoelectronic properties achievable via a direct gap for Sn concentrations exceeding ≈10 at. %. The substantial misfit strain imposed on Ge–Sn thin films during growth on bulk Si or Ge substrates can induce defect formation; however, misfit strain can be accommodated by growing Ge–Sn alloy films on Ge nanowires, which effectively act as elastically compliant substrates. In this work, Ge core/Ge 1–x Sn x (x ≈ 0.1) shell nanowires were characterized with extended x-ray absorption fine structure (EXAFS) to elucidate their local atomic environment. Simultaneous fitting of high-quality EXAFS data collected at both the Ge K-edge and the Sn K-edge reveals a large (≈ 40%) deficiency of Sn in the first coordination shell around a Sn atom relative to a random alloy, thereby providing the first direct experimental evidence of significant short-range order in this semiconductor alloy system. Furthermore, comparison of path length data from the EXAFS measurements with density functional theory simulations provides alloy atomic structures consistent with this conclusion.

36 MATERIALS SCIENCE↗

Radiative natural supersymmetry emergent from the string landscape

In string theory with flux compactifications, anthropic selection for structure formation from a discretuum of vacuum energy values provides at present our only understanding of the tiny yet positive value of the cosmological constant. We apply similar reasoning to a toy model of the multiverse restricted to vacua with the MSSM as the low energy effective theory. Here, one expects a statistical selection favoring large soft SUSY breaking terms leading to a derived value of the weak scale in each pocket universe (with appropriate electroweak symmetry breaking) which differs from the weak scale as measured in our universe. In contrast, the SUSY preserving μ parameter is selected uniformly on a log scale as is consistent with the distribution of SM fermion masses: this favors smaller values of μ. An anthropic selection of the weak scale to within a factor of a few of our measured value — in order to produce complex nuclei as we know them (atomic principle) — provides statistical predictions for Higgs and sparticle masses in accord with LHC measurements. The statistical selection then more often leads to (radiatively-driven) natural SUSY models over the Standard Model or finely-tuned SUSY models such as mSUGRA/CMSSM, split, mini-split, spread, high scale or PeV SUSY. The predicted Higgs and superparticle spectra might be testable at HL-LHC or ILC via higgsino pair production but is certainly testable at higher energy hadron colliders with $ \sqrt{s}$ ~ 30–100 TeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Investigation of Mechanical Properties of Parts Fabricated with Gas- and Water-Atomized 304L Stainless Steel Powder in the Laser Powder Bed Fusion Process

In this report the use of gas-atomized powder as the feedstock material for the Laser Powder Bed Fusion (L-PBF) process is common in the Additive Manufacturing (AM) community. Although gas-atomization produces powder with high sphericity, its relatively expensive production cost is a downside for application in AM processes. Water atomization of powder may overcome this limitation due to its low cost relative to the gas-atomization process. In this work, gas- and water-atomized 304L stainless steel powders were morphologically characterized through Scanning Electron Microscopy (SEM). The water-atomized powder had a wider particle size distribution and exhibited less sphericity. Measuring powder flowability using the Revolution Powder Analyzer (RPA) indicated that the water-atomized powder had less flowablility than the gas-atomized powder. Through examining the mechanical properties of L-PBF fabricated parts using tensile tests, the gas-atomized powder had significantly higher yield tensile strength and elongation than the water-atomized powder, however, their ultimate tensile strengths were not significantly different.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Revealing the Latent Atomic World Through Data-Driven Microscopy

Many emerging technologies depend on the precise design of materials structure, chemistry, and defects. As devices shrink, manufacturing tolerances tighten, and performance envelopes improve, we must increasingly measure and manipulate materials at or near the single atom level. Here we describe how transmission electron microscopy (TEM) underpins our ability to see and direct the latent atomic world. We review a selection of our recent high-resolution TEM studies of the synthesis of oxide-based nanomaterials and their evolution in extreme environments. We then discuss powerful new artificial intelligence (AI) and machine learning (ML) approaches we have developed for rich, reproducible, and scalable experimentation. Furthermore, we conclude by discussing future developments that will enable new materials for breakthrough technologies.

97 MATHEMATICS AND COMPUTING↗

Controlling spin-orbit coupling strength of bulk transition metal dichalcogenide semiconductors

Transition metal dichalcogenide (TMD) semiconductors are attracting much attention in research regarding device physics based on their unique properties that can be utilized in spintronics and valleytronics. Although current studies concentrate on the monolayer form due to the explicitly broken inversion symmetry and the direct band gap, bulk materials also hold the capability of carrying spin and valley current. In this study, we report the methodology to continuously control the spin-orbit coupling (SOC) strength of bulk TMDs Mo 1-x W x Se 2 by changing the atomic ratio between Mo and W. The results show the size of band splitting at the K valley the measure of the coupling strength is linearly proportional to the atomic ratio of Mo and W. Here, our results thus demonstrate how to precisely tune the SOC coupling strength, and the collected information of which can serve as a reference for future applications of bulk TMDs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optically pumped gradient magnetometer

A method is provided for sensing a magnetic field in a magnetic gradiometer of the kind in which pump light and light constituting an optical carrier traverse first and second atomic vapor cells that contain host atoms and that are separated from each other by a known distance. According to such method, the host atoms are prepared in a coherent superposition of two quantum states that differ in energy by an amount that is sensitive to an ambient magnetic field. Modulation of the optical carrier in the respective cells gives rise to sidebands that interfere to generate a beat frequency indicative of the magnetic field gradient. The host atoms are prepared at least in a mode that allows measurement of ambient magnetic field components perpendicular to the axis of the pump light. In such mode, the host atoms are spin-polarized by pump light while subjected to a controlled magnetic field directed parallel to the pump beam, and then the controlled magnetic field is adiabatically extinguished.

47 OTHER INSTRUMENTATION↗

Primary $\gamma$-ray intensities and $\gamma$-strength functions from discrete two-step $\gamma$-ray cascades in radiative proton-capture experiments

Background: Reaction rates of radiative capture reactions can play a crucial role in the nucleosynthesis of heavy nuclei in explosive stellar environments. These reaction rates depend strongly on $\gamma$-ray decay widths in the reaction products, which are, for nonresonant capture reactions at high excitation energies, derived from the $\gamma$-ray strength function and the nuclear level density. Recently, the ratio method was applied to primary $\gamma$ rays observed from ($\textit{d, p}$) reactions and nuclear resonance fluorescence measurements to extract the dipole strength in atomic nuclei and to test the generalized Brink-Axel hypothesis. Purpose: The purpose of this work is to apply the ratio method to primary $\gamma$-ray intensities of the 63,65 Cu($\textit{p},\gamma$) reactions to extract $\gamma$-ray strength information on the nuclei 64,66 Zn. Here, the impact of spin distribution, total $\gamma$-ray decay widths, level densities, and width fluctuations on the application of the ratio method will be discussed. Additionally, by comparing the relative $\gamma$-ray strength at different excitation energies, conclusions on the validity of the generalized Brink-Axel hypothesis can be made. Method: The radiative proton capture reaction measurements have been performed at the HORUS $\gamma$-ray spectrometer of the University of Cologne at one excitation energy for each reaction. Primary $\gamma$-ray intensities have been determined by normalizing secondary $\gamma$-ray transitions in two-step cascades using their absolute branching ratio. The ratio method was applied to the measured primary $\gamma$-ray intensities as well as to previous measurements by Erlandsson et al. at different excitation energies. Results: The relative strength function curve for 64 Zn from our measurement shows no significant deviation from the previous measurement at a different excitation energy. The same is true for 66 Zn where both measurements were at almost the same excitation energy. Absolute $\gamma$-strength function values have been obtained by normalizing the relative curves to quasiparticle random phase approximation calculations because of the absence of experimental data in the respective energy region. Conclusion: The generalized Brink-Axel hypothesis, i.e., the independence of the strength function on the excitation energy, seems to hold in the studied energy region and nuclei. The method to obtain primary $\gamma$-ray intensities from two-step cascade spectra was shown to be a valuable and sensitive tool although its uncertainties are connected to the knowledge of the low-energy level scheme of the investigated nucleus. The scaling in the ratio method should be taken with care, because the relative strength is not a simple sum of $f_{E1}$ and $f_{M1}$ but a somewhat complex linear combination dependent on the excitation energy of the nucleus.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Interpretation of Lyman opacity measurements in JET with the ITER-like wall using a particle balance approach

Recent measurements of the Ly β /D α ratio in the JET ITER-like wall (ILW) divertor show comparatively more pronounced Ly β reabsorption relative to previous results in JET with the carbon wall (JET-C). At the outer horizontal target ion current rollover point a Ly β reabsorption rate of 60% is measured, increasing to 80% in more pronounced detachment, implying a Ly α reabsorption rate of 90%–98%. The radially resolved Ly β /D α measurements are used to constrain Lyman opacity corrections to atomic rate coefficients using the population escape factor technique in order to capture the local changes to the excited state population structure in the high Lyman opacity regions at and outboard of the outer strike point. To check the self-consistency of the Lyman opacity measurements, a detailed spectroscopic interpretation of the outer divertor particle balance is presented, in which the impact of opacity corrections to the Ly α inverse photon efficiency coefficients is assessed. A five-fold deficit in the estimated D + source rate obtained with optically thin plasma assumptions is reconciled once the opacity corrections are factored into the Ly α photon rate to ionization rate conversion. The experiment results are reproduced in EDGE2D-EIRENE density scan simulations in which an imposed ad hoc Lyman reabsorption rate is recovered spectroscopically using synthetic measurements, and a similar shortfall in the D + source rate estimates is reconciled using Lyman opacity corrected atomic data. The model limitations prevent a more detailed self-consistent analysis of the Lyman opacity impact on divertor parameters and detachment evolution, and hence motivate renewed efforts to re-establish routine exploitation of the photon transport modelling capabilities in the EIRENE code package. Lyman opacity corrections to atomic data coefficients are necessary for spectroscopic interpretation of the JET-ILW divertor plasma, with significant influence on the divertor plasma also a likely consequence of the presence of strong Ly α reabsorption. Finally, a scan of auxiliary heating powers spanning L-mode and H-mode conditions reveals a strong correlation of the measured Ly β opacity with the outer target temperature, suggesting new possibilities for using Lyman opacity measurements in establishing detachment scalings.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-Resolution Momentum Imaging—From Stern’s Molecular Beam Method to the COLTRIMS Reaction Microscope [Book Chapter]

Multi-particle momentum imaging experiments are now capable of providing detailed information on the properties and the dynamics of quantum systems in Atomic, Molecular and Photon (AMO) physics. Historically, Otto Stern can be considered the pioneer of high-resolution momentum measurements of particles moving in a vacuum and he was the first to obtain sub-atomic unit (a.u.) momentum resolution (Schmidt-Böcking et al. in The precision limits in a single-event quantum measurement of electron momentum and position, these proceedings). A major contribution to modern experimental atomic and molecular physics was his so-called molecular beam method, which Stern developed and employed in his experiments. With this method he discovered several fundamental properties of atoms, molecules and nuclei. As corresponding particle detection techniques were lacking during his time, he was only able to observe the averaged footprints of large particle ensembles. Today it is routinely possible to measure the momenta of single particles, because of the tremendous progress in single particle detection and data acquisition electronics. A “state-of-the-art” COLTRIMS reaction microscope can measure, for example, the momenta of several particles ejected in the same quantum process in coincidence with sub-a.u. momentum resolution. Such setups can be used to visualize the dynamics of quantum reactions and image the entangled motion of electrons inside atoms and molecules. This review will briefly summarize Stern’s work and then present in longer detail the historic steps of the development of the COLTRIMS reaction microscope. Furthermore, some benchmark results are shown which initially paved the way for a broad acceptance of the COLTRIMS approach. Finally, a small selection of milestone work is presented which has been performed during the last two decades.

Jahnke, T.↗

Operando Topography and Mechanical Property Mapping of CO 2 Reduction Gas-Diffusion Electrodes Operating at High Current Densities

Electrochemical atomic force microscopy (EC-AFM) enables measurement of electrode topography and mechanical properties during electrochemical reactions. However, for aqueous-based reactions that make gas products, such as CO 2 reduction and water splitting into CO/H 2 , current densities below 1 mA cm −2 have been necessary to prevent formation of bubbles at the electrode; such bubbles can stick to the AFM probe and prevent further AFM imaging. Here, we demonstrate a novel cell design with a gas-diffusion electrode (GDE) to exhaust the gas products, thereby enabling high current density EC-AFM measurements at 1, 10, and 100 mA cm −2 that are not disturbed by bubble formation at the electrode surface. These experiments revealed a stable morphological structure of Cu catalysts deposited on GDEs during high current density operation. Systematic spatially resolved maps of deformation and adhesion showed no signs of a gas-liquid interface between catalyst particles of the GDE.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗