Search NASA⌕ Search

SEARCH · Search NASA

Results for “BAFFLE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Crack Growth Rate and Fracture Toughness Tests on Irradiated Ex-Plant Materials

The performance of structural materials is critical for the safe and economic operation of light water reactors. Exposed to neutron irradiation during service, the reactor core internal materials can undergo significant microstructural and microchemical changes, leading to irradiation hardening and embrittlement. To ensure the structural integrity and functionality of nuclear reactor components during long-term operation, material degradation and damage mechanisms must be understood and managed adequately. In this work, irradiated materials harvested from the decommissioned Zorita reactor were studied for their cracking susceptibility and fracture resistance as a function of irradiation dose up to 47 displacement per atom (dpa). The material is a Type 304 stainless steel sectioned from the baffle plates of this pressurized water reactor with 38 years of service. Crack growth rate and fracture toughness J-resistance (J-R) curve tests were performed in low-corrosion-potential environments at ~315°C. All samples behaved similarly under cyclic loading, and no deteriorated corrosion-fatigue behavior was observed in the test environments. Under constant stress intensity factors, most samples did not show elevated crack growth rates, suggesting an adequate stress corrosion cracking resistance in the test environments. However, an unstable cracking behavior was observed in a 47-dpa sample, resulting in significantly higher crack growth rates than expected at high stress intensity factors. Crack instability was also observed in a 0.06-dpa sample but did not lead to a sustained high crack growth rate. The impact of neutron irradiation was more evident in the fracture toughness J-R curve tests. As the dose increased, the J-R curve declined considerably and became very shallow at high doses. A fully intergranular fracture morphology was also observed among the high-dose samples ruptured in an air atmosphere at room temperature. This brittle fracture mode in the absence of high temperature water environment confirmed a high degree of embrittlement of this material resulting from its service exposure to neutron irradiation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Irradiated Microstructure of Zorita Materials

Reactor baffle plate materials were harvested from the decommissioned Zorita nuclear power reactor after 38 years of service and were characterized with transmission electron microscope. The samples were Type 304 stainless steels and had been irradiated to 0.05, 16.9, ad 48.6 dpa. Faulted dislocation loops, voids, and irradiation-induced precipitates were observed in this material. While dislocation loops were the dominant irradiation defects for all samples, small voids and precipitates were also observed at 16.9 and 48.6 dpa, but not at 0.05 dpa. The size of dislocation loops increased with irradiation dose and saturated below 16.9 dpa. The loop density continued to increase between 16.9 and 48.6 dpa. For voids, both the density and mean size were small, and the volume swelling was negligibly small even at 48.6 dpa. In addition, carbides or G-phase precipitates were detected at 16.9 and 48.6 dpa, and a complex dose dependence was observed. A range of irradiation hardening was estimated at each dose, and the resulting yield strengths were consistent with the previous tensile results measured from the Halden and BOR-60 specimens.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optimization of Concurrent Deployments of the Juvenile Salmon Acoustic Telemetry System and Other Hydroacoustic Equipment at John Day Dam

The purpose of this report is to document the results of the acoustic optimization study conducted at John Day Dam during January and February 2008. The goal of the study was to optimize performance of the Juvenile Salmon Acoustic Telemetry System (JSATS) by determining deployment and data acquisition methods to minimize electrical and acoustic interference from various other acoustic sampling devices. Thereby, this would allow concurrent sampling by active and passive acoustic methods during the formal evaluations of the prototype surface flow outlets at the dam during spring and summer outmigration seasons for juvenile salmonids. The objectives for the optimization study at John Day Dam were to: 1. Design and test prototypes and provide a total needs list of pipes and trolleys to deploy JSATS hydrophones on the forebay face of the powerhouse and spillway. 2. Assess the effect on mean percentage decoded of JSATS transmissions from tags arrayed in the forebay and detected on the hydrophones by comparing: turbine unit OFF vs. ON; spill bay OPEN vs. CLOSED; dual frequency identification sonar (DIDSON) and acoustic Doppler current profiler (ADCP) both OFF vs. ON at a spill bay; and, fixed-aspect hydroacoustic system OFF vs. ON at a turbine unit and a spill bay. 3. Determine the relationship between fixed-aspect hydroacoustic transmit level and mean percentage of JSATS transmissions decoded. The general approach was to use hydrophones to listen for transmissions from JSATS tags deployed in vertical arrays in a series perpendicular to the face of the dam. We used acoustic telemetry equipment manufactured by Technologic and Sonic Concepts. In addition, we assessed old and new JSATS signal detectors and decoders and two different types of hydrophone baffling. The optimization study consisted of a suite of off/on tests. The primary response variable was mean percentage of tag transmissions decoded. We found that there was no appreciable adverse effect on mean percentage decoded for JSATS transmitters from: turbine operations; spillway operations; DIDSON/ADCP acoustic energy; and PAS hydroacoustic systems at transmit level of -12 dB, although there was a significant impact at all higher transmit levels (-11 to -6 dB). The main conclusion from this optimization study is that valid JSATS telemetry data can be collected simultaneously with a DIDSON/ADCP and a PAS hydroacoustic system at transmit level -12 dB. Multiple evaluation tools should be considered to increase the robustness and thoroughness of future fish passage evaluations at John Day and other dams.

13 HYDRO ENERGY↗

Reducing the Flow Maldistribution in Heat Exchangers through a Novel Polymer Manifold: Numerical Evaluation

The maldistribution of working fluid is one of the issues in heat exchangers that causes a reduction in performance of not only the heat exchanger but also the entire HVAC system. One of the methods to reduce such maldistribution is to improve manifold design to evenly distribute the flow. In the present work, an advanced maldistribution reduction manifold, which was based on a preliminary maldistribution reduction manifold, was designed to further improve the flow distribution in the heat exchanger. In the design, spiral baffles are used to create vortices in the tubes to regulate the flow in each tube. The design also keeps the tubes away from the manifold inlet to avoid direct flow from the inlet. Due to the complexity, the design of the advanced maldistribution reduction manifold is for AM only, which cannot be fabricated by traditional manufacturing. To evaluate the design, a computational fluid dynamic model is developed to study flow distribution in heat exchanger manifolds. The simulation results reveal that the relative standard deviation of the tubes in the advanced maldistribution reduction design is half of the preliminary maldistribution reduction design and about 1/20 of the reference design.

42 ENGINEERING↗

Machine Learning-Driven Quantification of CO2 Plume Dynamics at Illinois Basin Decatur Project Sites Using Microseismic Data

This study utilizes machine learning to quantify CO2 plume extents by analyzing microseismic data from the Illinois Basin Decatur Project (IBDP). Leveraging a unique dataset of well logs, microseismic records, and CO2 injection metrics, this work aims to predict the temporal evolution of subsurface CO2 saturation plumes. The findings illustrate that machine learning can predict plume dynamics, revealing vertical clustering of microseismic events over distinct time periods within certain proximities to the injection well, consistent with an invasion percolation model. The buoyant CO2 plume partially trapped within sandstone intervals periodically breaches localized barriers or baffles, which act as leaky seals and impede vertical migration until buoyancy overcomes gravity and capillary forces, leading to breakthroughs along vertical zones of weakness. Between different unsupervised clustering techniques, K-Means and DBSCAN were applied and analyzed in detail, where K-means outperformed DBSCAN in this specific study by indicating the combination of the highest Silhouette Score and the lowest Davies–Bouldin Index. The predictive capability of machine learning models in quantifying CO2 saturation plume extension is significant for real-time monitoring and management of CO2 sequestration sites. The models exhibit high accuracy, validated against physical models and injection data from the IBDP, reinforcing the viability of CO2 geological sequestration as a climate change mitigation strategy and enhancing advanced tools for safe management of these operations.

Iyegbekedo, Ikponmwosa↗

Measurement of the Absolute Crab Flux with NuSTAR

We present results from a Nuclear Spectroscopic Telescope Array (NuSTAR) observation of the Crab made at a large off-axis angle of 1.°5. At these angles, X-rays do not pass through the optics and instead illuminate the detectors directly, due to incomplete baffling. Due to the simplicity of the instrument response in this configuration and the good absolute calibration of the detectors, we are able to measure the absolute intrinsic flux of the Crab to better than 4%. We find the spectral parameters of the power law to be Γ=2.106±0.006, N=9.71±0.16, in agreement with the values measured 42 years ago by Toor and Seward. This suggests that the observed variability of the Crab is not part of a long-term trend, but instead results from fluctuations around a steady mean. The NuSTAR observation also enabled improved measurement of the detector absorption parameters without the added complications of the mirror response.

79 ASTRONOMY AND ASTROPHYSICS↗

Fluctuation statistics in the scrape-off layer of Alcator C-Mod

We study long time series of the ion saturation current and oating potential, sampled by Langmuir probes dwelled in the outboard mid-plane scrape-off layer and embedded in the lower divertor baffle of Alcator C-Mod. A series of ohmically heated L-mode plasma discharges is investigated with line-averaged plasma density ranging from ne/nG = 0.15 to 0.42, where nG is the Greenwald density. All ion saturation current time series that are sampled in the far scrape-off layer are characterized by large-amplitude burst events. Coefficients of skewness and excess kurtosis of the time series obey a quadratic relationship and their histograms coincide partially upon proper normalization. Histograms of the ion saturation current time series are found to agree well with a prediction of a stochastic model for the particle density fluctuations in scrape-off layer plasmas. The distribution of the waiting times between successive large-amplitude burst events and of the burst amplitudes are approximately described by exponential distributions. The average waiting time and burst amplitude are found to vary weakly with the line-averaged plasma density. Conditional averaging reveals that the radial blob velocity, estimated from floating potential measurements, increases with the normalized burst amplitude in the outboard mid- plane scrape-off layer. For low density discharges, the conditionally averaged waveform of the floating potential associated with large amplitude bursts at the divertor probes has a dipolar shape. In detached divertor conditions the average waveform is random, indicating electrical disconnection of blobs from the sheaths at the divertor targets.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of passively stable, fully detached divertor plasma regimes attained in innovative long-legged divertor configurations

Numerical modeling of divertor configurations with radially or vertically extended, tightly baffled, outer divertor legs has demonstrated the existence of a passively-stable fully detached divertor regime. In the simulations, long-legged divertors provide up to an order-of- magnitude increase in peak power handling capability compared to conventional divertors. The key physics for attaining the passively stable, fully detached regime in these simulations involves the interplay of strong convective plasma transport to the divertor leg outer sidewall, confinement of neutral gas in the divertor volume, geometric effects including a secondary X-point, and atomic radiation. New analysis shows that in this regime the detachment front location is set by the balance between the power entering the divertor leg and the losses to the walls of the divertor channel. Correspondingly, the maximum power that can be accommodated by the divertor, while still staying detached, increases with the poloidal length of the leg. The detached regime access window in terms of input power, density and impurity seeding concentration varies quantitatively depending on divertor geometry and modeling assumptions most specifically, cross-field transport to the side walls.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of the Damping of Liquids in Right-Circular Cylindrical Tanks, Including the Effects of a Time-Variant Liquid Depth

An experimental investigation was conducted to determine the effects of several basic variables upon the damping of the fundamental antisymmetric mode of liquids in right-circular cylindrical tanks without baffles. The variables examined include liquid depth, efflux rate, liquid amplitude, kinematic viscosity, and tank size. The data are presented in dimensionless form and compared with available theory. For the range of variables examined, variations of efflux rate and liquid amplitude were found to have no significant effects on the liquid damping. The following theoretical relationship was found to be adequate for the prediction of the variation of damping with liquid depth, kinematic viscosity, and tank size: [for equation see full text] where v is the kinematic viscosity, R is the cylinder radius, g is the acceleration due to gravity, and h is the liquid depth. However, the constant K was experimentally found in this investigation to have the value 5.23, which is 50 percent higher than the theoretically predicted value.

TANK↗

Fine-particle filter prevents damage to vacuum pumps

A filter system for mechanical pumps is designed with a baffle assembly that rotates in a circulating oil bath which traps destructive particles. This prevents severe damage to the pump and is serviceable for long periods before it requires cleaning.

Harlamert, P., Jr.↗

Test device prevents molecular bounce-back

A test device, which consists of six pyramidal reflectors joined together, acts as a baffle to impede the free path of the molecule to the test item by interposing a slanted surface which imparts an angular vector to the molecule and bounces it back to the chamber wall.

Hardgrove, W. F.↗

Uniform reflective films deposited on large surfaces

Specially designed baffle which intercepts varying amounts of the vapor stream from an evaporant source, vacuum deposits films of uniform thickness on large substrates, using a single small area evaporation source. A mirror coated by this method will have a reflectance as high as 82 percent at 1216 angstroms with a variation of only plus/minus 2 percent over the surface.

Source record↗

A method of determining combustion gas flow

Zirconium oxide coating enables the determination of hot gas flow patterns on liquid rocket injector face and baffle surfaces to indicate modifications that will increase performance and improve combustion stability. The coating withstands combustion temperatures and due to the coarse surface and coloring of the coating, shows the hot gas patterns.

Bon Tempi, P. J.↗