Search NASA⌕ Search

SEARCH · Search NASA

Results for “CALIBRATION STANDARDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25

Monitoring forest land from high altitude and from space

Forest inventory, forest stress, and standardization and calibration studies are presented. These include microscale photointerpretation of forest and nonforest land classes, multiseasonal film densities for automated forest and nonforest land classification, trend and spread of bark beetle infestations from 1968 through 1971, aerial photography for determining optimum levels of stand density to reduce such infestations, use of airborne spectrometers and multispectral scanners for previsual detection of Ponderosa pine trees under stress from insects and diseases, establishment of an earth resources technology satellite test site in the Black Hills and the identification of natural resolution targets, detection of root disease impact on forest stands by sequential orbital and suborbital multispectral photography, and calibration of color aerial photography.

Source record↗

Piston manometer as an absolute standard for vacuum-gauge calibration.

Determination of total pressure in a calibration volume by measuring the force on a thin circular disk, of accurately-known area, that is freely suspended in a hole in the container wall, so that the disk is substantially flush with the wall. The disk almost fills the hole, so that there is a narrow annular gap. A continuous flow of calibrating gas, injected into the container in order to maintain a desired pressure, passes through the annular gap to a diffusion pump. The ratio of pressures on the two faces of the disk is on the order of 100:1, so that downstream pressure need be known only nominally in order to deduce the upstream pressure. Force on the disk is measured by a balance that is calibrated in situ with dead weights. In one arrangement, pressures in the range from 10 to 500 microtorr were measured with an estimated probable error of (1 microtorr + 1%).

Warshawsky, I.↗

Piston manometer as an absolute standard for vacuum-gauge calibration.

Determination of the total pressure in a calibration volume by measuring the force on a thin circular disk, of accurately known area, that is freely suspended in a hole in the container wall, so that the disk is substantially flush with the wall. The disk almost fills the hole, so that there is a narrow annular gap. A continuous flow of calibrating gas, injected into the container in order to maintain a desired pressure, passes through the annular gap to a diffusion pump. The ratio of pressures on the two faces of the disk is of the order of 100:1, so that downstream pressure need be known only nominally in order to deduce the upstream surface. Force on the disk is measured by a balance that is calibrated in situ with dead weights. In one arrangement, pressures in the range from 10 to 500 microtorr were measured with an estimated probable error of (1 microtorr + 1%).

Warshawsky, I.↗

Piston manometer as an absolute standard for vacuum-gage calibration in the range 2 to 500 millitorr

A thin disk is suspended, with very small annular clearance, in a cylindrical opening in the base plate of a calibration chamber. A continuous flow of calibration gas passes through the chamber and annular opening to a downstream high vacuum pump. The ratio of pressures on the two faces of the disk is very large, so that the upstream pressure is substantially equal to net force on the disk divided by disk area. This force is measured with a dynamometer that is calibrated in place with dead weights. A probable error of + or - (0.2 millitorr plus 0.2 percent) is attainable when downstream pressure is known to 10 percent.

Warshawsky, I.↗

In situ transfer standard for ultrahigh vacuum gage calibration

A compact insitu calibration assembly, for ultrahigh vacuum gauges is described. The system depends on the repeatable generation of a specific gas pressure by the dissociation of a solid solution chemical compound when subjected to a given temperature. A precise temperature measurement is related to the pressure generated within the vacuum by the properties of the solid solution compound. this accurately establishes the gas pressure which in turn is used to calibrate a vacuum gauge. Also included is a metering orifice used in the calibration system and which is made movable to facilitate the degassing bakeout required in ultrahigh vacuum devices.

Outlaw, R. A.↗

Monitoring forest land from high altitude and from space

The significant findings are reported for remote sensing of forest lands conducted during the period October 1, 1965 to December 31, 1972. Forest inventory research included the use of aircraft and space imagery for forest and nonforest land classification, and land use classification by automated procedures, multispectral scanning, and computerized mapping. Forest stress studies involved previsual detection of ponderosa pine under stress from insects and disease, bark bettle infestations in the Black Hills, and root disease impacts on forest stands. Standardization and calibration studies were made to develop a field test of an ERTS-matched four-channel spectrometer. Calibration of focal plane shutters and mathematical modeling of film characteristic curves were also studied. Documents published as a result of all forestry studies funded by NASA for the Earth Resources Survey Program from 1965 through 1972 are listed.

Source record↗

Determination of left ventricular size and shape

Significant advances have occurred over the past 15 years in the ability to measure ventricular dimensions. Angiocardiography still remains the most reliable method for overall determination of chamber size and shape and serves as a standard for calibration or comparison for newer methods. Improvements in the use of radiographic methods over the next few years are anticipated with more extensive use of multiplane studies associated with repeated injections of improved contrast materials that produce fewer physiological effects or with substances that adhere to the endocardial surfaces. It is also anticipated that existing methods for automatically obtaining dimensional information from X rays will be continued and improved.

Sandler, H.↗

Demonstration of optical navigation measurements on Mariner 10

An experiment was performed on the Mariner 10 Venus/Mercury mission to assess the performance of the onboard television cameras and ground-based software used in the optical navigation measurement system. The elements of the system, calibration, and distortion are considered. The navigation technique requires detection of stars in the same field of view as the target body. The star detection capability is discussed with reference to required threshold, calibration factors, standard conditions, camera sensitivity, response uniformity, and the effect of image smearing. Tests conducted during the Mariner 10 encounters with Mercury demonstrated that a large bright planet can be imaged simultaneously with faint stars to provide accurate navigation data. Improvements are suggested in the system for the Mariner Jupiter/Saturn 1977 and later missions.

Stanton, R. H.↗

Automated secondary standard for liquid flowmeters

Calibration time is reduced from one hour to fifteen minutes. Accuracies of flowmeter calibrations are approximately 99.75 percent, using this standard. Standard is also used to test or set flow switches.

Hobart, H. F.↗

Rarefied gas dynamic effects on mass spectrometric studies of upper planetary atmospheres

Results are presented of measurements obtained with an open-source mass spectrometer both in earth orbit and in a laboratory molecular beam facility. The mass spectrometer/ion source combination was developed in the laboratory to be operable in either of two modes by altering ion extraction potential on ground command, i.e., as a stagnation cavity or to respond only to the incoming molecules of the unperturbed atmosphere. Results indicate that the use of this open-source configuration and dual-mode capability, allied with both standard static calibration and dynamic calibration using high-speed molecular beam techniques in the laboratory, allows collection of useful data on aeronomy of the upper atmosphere of planets and comet tails.

French, J. B.↗

Field limiter for solar radiometers

Lenses project solar image onto aperature to exclude circumsolar radiation, more precisely measuring energy captured by receiver aperatures of highly-concentrating solar thermal-energy converters. First version uses achromatic objective lens to form image of Sun at aperature ahead of radiometer cavity. Smaller second version with shorter focal length forms image magnified by another lens and thrown onto aperature. Both Versions require calibration against standard radiometer.

Berdahl, C. M.↗

Climate observing system studies: An element of the NASA Climate Research Program: Workshop report

Plans for NASA's efforts in climatology were discussed. Targets for a comprehensive observing system for the early 1990's were considered. A program to provide useful data in the near and mid-term, and a program to provide for a feasibility assessment of instruments and methods for the development of a long-term system were discussed. Climate parameters that cannot be measured from space were identified. Long-term calibration, intercomparison, standards, and ground truth were discussed.

Source record↗

Modifications to the nozzle test chamber to extend nozzle static-test capability

The nozzle test chamber was modified to provide a high-pressure-ratio nozzle static-test capability. Experiments were conducted to determine the range of the ratio of nozzle total pressure to chamber pressure and to make direct nozzle thrust measurements using a three-component strain-gage force balance. Pressure ratios from 3 to 285 were measured with several axisymmetric nozzles at a nozzle total pressure of 15 to 190 psia. Devices for measuring system mass flow were calibrated using standard axisymmetric convergent choked nozzles. System mass-flow rates up to 10 lbm/sec are measured. The measured thrust results of these nozzles are in good agreement with one-dimensional theoretical predictions for convergent nozzles.

Keyes, J. W.↗

Experimental verification of the thermodynamic properties for a jet-A fuel

Thermodynamic properties for a Jet-A fuel were determined by Shell Development Company in 1970 under a contract for NASA Lewis Research Center. The polynomial fit necessary to include Jet-A fuel (liquid and gaseous phases) in the library of thermodynamic properties of the NASA Lewis Chemical Equilibrium Program is calculated. To verify the thermodynamic data, the temperatures of mixtures of liquid Jet-A injected into a hot nitrogen stream were experimentally measured and compared to those calculated by the program. Iso-octane, a fuel for which the thermodynamic properties are well known, was used as a standard to calibrate the apparatus. The measured temperatures for the iso-octane/nitrogen mixtures reproduced the calculated temperatures except for a small loss due to the non-adiabatic behavior of the apparatus. The measurements for Jet-A were corrected for this heat loss and showed excellent agreement with the calculated temperatures. These experiments show that this process can be adequately described by the thermodynamic properties fitted for the Chemical Equilibrium Program.

Graciasalcedo, Carmen M.↗

Multispectral satellite observations for arid land studies

Multispectral satellite data when properly calibrated and standardized can be used synergistically for a quantitative analysis of processes and surface characteristics, and for quantifying land surface change. Relationships among multispectral satellite data (visible reflectance, surface temperature and polarization difference of microwave emission at 37 GHz frequency) have been used to develop hypotheses concerning the relative sensitivity of these data to varied land surface characteristics, which needs to be verified by field observations. Radiative transfer models have also been developed to understand these multispectral data. Interannual variations of visible reflectance and polarization difference for the period 1982-1986 over the Sahel and the Sudan zones of Africa show a lagged response with respect to the rainfall deficit during recovery from drought, which needs to be understood in terms of biophysical parameters.

Choudhury, Bhaskar J.↗

Spectral irradiance calibration in the infrared. III - The influence of CO and SiO

Efforts are described to establish a network of calibrated infrared spectra of 'standard stars' suitable for calibration of at least low-resolution infrared spectrometers using ground-based, airborne, and satellite-borne broadband sensors. Emphasis is given to the crucial 5-8 micron region in K and M giants, where the fundamental bands of CO and SiO cause substantial departures from featureless pseudocontinua. The invalidity of the blackbody assumption in the thermal infrared regime is pointed out by demonstrating the importance of these molecular features in cold giants stars in the airborne infrared regime and illustrating their influence on spectra calibrated using blackbody assumptions.

Cohen, Martin↗

Use of Spectralon as a diffuse reflectance standard for in-flight calibration of earth-orbiting sensors

Spectralon, a commercially available diffuse reflectance material made from polytetrafluoroethylene (PTFE), is being evaluated for the multiangle imaging spectroradiometer (MISR), currently under development for the Earth Observing System. Results of a series of environmental exposure tests indicate that no degradation of the optical properties was apparent following proton bombardment, and stability through UV illumination was satisfactory, provided simple cleaning and handling procedures were implemented. A buildup of several thousand volts of static charge was found to develop while simulating a rare pass through an auroral storm.

Bruegge, Carol J.↗

Apollo Metrology Program

This paper introduces the metrology requirements in the recently published Apollo Program handbook, NHB 5400.2, entitled, 'Apollo Metrology Requirements Manual.' The major elements and control practices required for a comprehensive metrology system are identified. The elements are presented to you with sufficient detail of control practices to provide the scope of a total metrology program. The Manual is for implementation by the Apollo Space Flight Centers, their testing sites and contractors. The benefits of implementing these requirements are equally applicable to any Government or industry standards and calibration laboratory operations.

Porter, W. A.↗